1.Repeatability of corneal astigmatism measured by IOL Master 700 in cataract patients
Bo YAO ; Yihui WANG ; Zhikun XIN
International Eye Science 2026;26(10):1806-1817
AIM: To investigate the repeatability of using IOL Master 700 to stratify corneal astigmatism and related biological parameters in cataract patients with different degrees of astigmatism, and evaluate its consistency with IOL Master 500.
METHODS: A cross-sectional study was conducted on preoperative cataract patientsadmitted to the hospital from February 2024 to September 2025. The patients were divided into three groups: low astigmatism group(astigmatism<0.75 D), moderate astigmatism group(0.75 D≤astigmatism≤1.50 D), and high astigmatism group(astigmatism>1.50 D). The IOL Master 700 and IOL Master 500 biometers were used by the same examiner respectively. Under the same environment, head position, and operating standards, each eye was continuously measured twice(with an interval of 3-5 min)with each instrument. Axial length(AL), anterior chamber depth(ACD), lens thickness(LT), corneal transverse diameter(WTW), flat curvature(Kf), steep curvature(Ks), mean curvature(Km), anterior corneal astigmatism(Kly), total corneal astigmatism(TK), iris-based diameter-vertical component(IBD-Ix), iris-based diameter-horizontal component(IBD-Iy)and astigmatism vectors J0 and J45 were recorded. Intraclass correlation coefficient(ICC)was used to evaluate the repeatability of IOL Master 700 measurements. Bland-Altman 95% limits of agreement(LoA)was used to evaluate the consistency of IOL Master 700 and IOL Master 500 measurements. Correlation scatter plots were used to evaluate the correlation between IOL Master 700 and IOL Master 500 measurements.
RESULTS:Totally 238 preoperative cataract patients(238 eyes)were selected as the research subjects and divided into a low astigmatism group of 88 cases, including 47 males and 41 females, with an average age of 68.14±6.25 y. The moderate astigmatism group consisted of 80 eyes, with 42 males and 38 females, with an average age of 68.13±6.98 y. The high astigmatism group consisted of 70 eyes, with 38 males and 32 females, with an average age of 69.11±6.79 y. The general information of the three groups of patients was comparable. In the low, medium, and high astigmatism groups, the ICC measured by IOL Master 700 for AL, ACD, LT, WTW, Kf, Ks, Km, Kly, TK, and IBD-Ix were all>0.90, and the ICC for IBD-Iy was>0.85. The ICC comparison of J0 and J45 patients with different degrees of astigmatism showed that the low astigmatism group was less than the moderate astigmatism group and less than the high astigmatism group. Bland Altman analysis between two devices showed that the 95% LoA width of AL, ACD, LT, WTW, Kf, Ks, Km, Kly, TK, and IBD-Ix was narrow, indicating good consistency between the two instruments. For the astigmatism vectors J0 and J45, the Bland Altman 95% LoA width between the two devices decreased with increasing astigmatism. A correlation scatter plot was drawn, which showed that the scatter points of AL, ACD, LT, WTW, Kf, Ks, Km, Kly, TK, IBD-Ix, and IBD-Iy were closely clustered on both sides of the diagonal without obvious outliers, indicating high correlation. J0 and J45 scatter points were still distributed along the diagonal, but the degree of dispersion was significantly greater than the above parameters, indicating slightly lower correlation.
CONCLUSION:IOL Master 700 exhibits goodtoexcellent repeatability in measuring parameters such as AL, ACD, LT, WTW, corneal curvature, Kly, TK, IBD-Ix,and IBD-Iy in cataract patients with different degrees of astigmatism, and shows good agreement with the IOL Master 500. However, for the astigmatism vectors J0 and J45, the repeatability of IOL Master 700 and its consistency with IOL Master 500 both decrease with decreasing astigmatism, and the difference is particularly significant in patients with low astigmatism. Therefore, astigmatism vector outcomes obtained from a single measurement should be interpreted with caution in patients with low astigmatism.
2.Recent advances in mechanisms, evaluations and treatments of in-stent stenosis following flow diverter implantation from hemodynamics perspective
Zhikun JIA ; Mengshi HUANG ; Xifeng LI ; Yanchao LIU ; Shixing SU ; Chuanzhi DUAN ; Xin ZHANG
Chinese Journal of Neuromedicine 2025;24(5):514-518
Flow diverter (FD) devices have gradually become the mainstream approach for interventional treatment of intracranial aneurysms. In-stent stenosis (ISS) is a common complication after FD implantation, which can lead to ischemic events and affect the prognosis of patients. Current studies have shown that ISS occurrence is closely related to hemodynamic changes. From the perspective of hemodynamics, this article reviews the research progress of mechanisms, evaluation methods and treatments of ISS after FD implantation, in order to provide reference for clinical practice.
3.Recent advances in mechanisms, evaluations and treatments of in-stent stenosis following flow diverter implantation from hemodynamics perspective
Zhikun JIA ; Mengshi HUANG ; Xifeng LI ; Yanchao LIU ; Shixing SU ; Chuanzhi DUAN ; Xin ZHANG
Chinese Journal of Neuromedicine 2025;24(5):514-518
Flow diverter (FD) devices have gradually become the mainstream approach for interventional treatment of intracranial aneurysms. In-stent stenosis (ISS) is a common complication after FD implantation, which can lead to ischemic events and affect the prognosis of patients. Current studies have shown that ISS occurrence is closely related to hemodynamic changes. From the perspective of hemodynamics, this article reviews the research progress of mechanisms, evaluation methods and treatments of ISS after FD implantation, in order to provide reference for clinical practice.
4.Deciphering the placental abnormalities associated with somatic cell nuclear transfer at single-nucleus resolution.
Liyuan JIANG ; Xin WANG ; Leyun WANG ; Sinan MA ; Yali DING ; Chao LIU ; Siqi WANG ; Xuan SHAO ; Ying ZHANG ; Zhikun LI ; Wei LI ; Guihai FENG ; Qi ZHOU
Protein & Cell 2023;14(12):924-928
5.Vitrectomy combined with cataract surgery in treatment of proliferative diabetic retinopathy
Xuefang JIA ; Xuefeng FENG ; Zhikun XIN ; Bin XIAO
Journal of Regional Anatomy and Operative Surgery 2017;26(3):215-217
Objective To investigate the clinical effects of vitrectomy combined with cataract surgery in the treatment of proliferative diabetic retinopathy (PDR V-VI stage).Methods A total of 80 patients with proliferative diabetic retinopathy from January 2012 to January 2014 were divided into the single group and the combined group according to the surgical method.Patients of the single group were treated by vitrectomy while patients of the combined group were treated by vitrectomy combined with cataract surgery.The incidence of retinal reattachment,postoperative vision and surgical complications between the two groups were compared.Results Compared with the single group,the incidence of retinal reattachment was higher in combined group (P < 0.05).The postoperative vision improvement was better than that in single group,the difference was significant (P < 0.05).And the surgical complications in combined group was less than that in single group,the difference was significant (P < 0.05).Conclusion Vitrectomy combined with cataract surgery in the treatment of proliferative diabetic retinopathy has a better clinical effect which is safe and reliable,and it can improve the rate of retinal reattachment and reduce surgical complications.
6.Effect of surgical treatment of tricuspid valve regurgitation after valve replacement
Zhikun FU ; Zichao DONG ; Xiaowei GU ; Zhiyuan ZHANG ; Hong DU ; Wei YAO ; Xin WU
Chinese Journal of Postgraduates of Medicine 2013;(5):25-27
Objective To evaluate the outcome of surgical treatment of tricuspid valve regurgitation after valve replacement.Methods Twenty one patients with tricuspid valve insufficiency after valve replacement were performed surgical treatment.Tricuspid valve-plasty was performed in 17 patients and tricuspid valve replacement was done in 4 patients.Three patients underwent edge-to-edge tricuspid valveplasty.DeVega procedure was performed in 5 patients.Cosgrove-Edward annuloplasty ring was used in 15 patients.Four patients' valve were replaced by SJM bileallet mechanical prostheses.Results There was 3 patients dead early after operation with a mortality of 14.3%(3/21).The causes of death including multiple organ failure,cardiac arrest and low cardiac output syndrome.The rate of early postoperative complications was 33.3% (7/21),including pulmonary edema,arrhythmia,acute renal failure and low cardiac output syndrome.The patients were followed up 9-60 months.The rate of readmission was 23.8% (5/21).Two patients went to hospital again for pleural effusion,1 patient for left ventricular dysfunction and 2 patients for right ventricular dysfunction.The other patients recovered well.Conclusions Surgical therapy is effective on severe tricuspid valve regurgitation after valve replacement.Preoperative aggressive treatment of heart failure,a reasonable grasp of surgical indications and timing of surgery,strict perioperative management are the keys to guarantee patients a smooth recovery.

Result Analysis
Print
Save
E-mail