1.Research progress of ocular surface damage in thyroid-associated ophthalmopathy
Chengyu MA ; Ying XIE ; Zhijun DONG
International Eye Science 2025;25(6):942-945
Thyroid-associated ophthalmopathy(TAO), the most common orbital disease in adults, is characterized by a rising incidence globally. TAO typically presents with clinical features such as proptosis, upper eyelid retraction, ocular motility dysfunction, and diplopia. Additionally, it significantly compromises the integrity of ocular surface structures, leading to symptoms including dryness, foreign body sensation, photophobia and epiphora, which severely impair patients' visual function and quality of life. Recent studies have increasingly highlighted the roles of ocular surface inflammation, immune dysregulation and ocular surface exposure in the pathogenesis of TAO-related ocular surface damage. These factors collectively contribute to pathological changes in ocular surface structures, such as the conjunctiva, cornea, lacrimal gland and meibomian glands. This review comprehensively summarizes the latest research progress on ocular surface structural damage in TAO patients, aiming to provide a theoretical foundation and novel insights for the early diagnosis, disease evaluation and individualized treatment of TAO.
2.Pathogenesis and treatment progress of flap ischemia-reperfusion injury
Bo HE ; Wen CHEN ; Suilu MA ; Zhijun HE ; Yuan SONG ; Jinpeng LI ; Tao LIU ; Xiaotao WEI ; Weiwei WANG ; Jing XIE
Chinese Journal of Tissue Engineering Research 2025;29(6):1230-1238
BACKGROUND:Flap transplantation technique is a commonly used surgical procedure for the treatment of severe tissue defects,but postoperative flap necrosis is easily triggered by ischemia-reperfusion injury.Therefore,it is still an important research topic to improve the survival rate of transplanted flaps. OBJECTIVE:To review the pathogenesis and latest treatment progress of flap ischemia-reperfusion injury. METHODS:CNKI,WanFang Database and PubMed database were searched for relevant literature published from 2014 to 2024.The search terms used were"flap,ischemia-reperfusion injury,inflammatory response,oxidative stress,Ca2+overload,apoptosis,mesenchymal stem cells,platelet-rich plasma,signaling pathways,shock wave,pretreatment"in Chinese and English.After elimination of irrelevant literature,poor quality and obsolete literature,77 documents were finally included for review. RESULTS AND CONCLUSION:Flap ischemia/reperfusion injury may be related to pathological factors such as inflammatory response,oxidative stress response,Ca2+overload,and apoptosis,which can cause apoptosis of vascular endothelial cells,vascular damage and microcirculation disorders in the flap,and eventually lead to flap necrosis.Studies have found that mesenchymal stem cell transplantation,platelet-rich plasma,signaling pathway modulators,shock waves,and pretreatment can alleviate flap ischemia/reperfusion injuries from different aspects and to varying degrees,and reduce the necrosis rate and necrosis area of the grafted flap.Although there are many therapeutic methods for skin flap ischemia/reperfusion injury,a unified and effective therapeutic method has not yet been developed in the clinic,and the advantages and disadvantages of various therapeutic methods have not yet been compared.Most of the studies remain in the stage of animal experiments,rarely involving clinical observations.Therefore,a lot of research is required in the future to gradually move from animal experiments to the clinic in order to better serve the clinic.
3.Experimental Evaluation of the Clinical Laboratory ELISA Assay Using A Randomization Quality Control Method for Indoor Quality Control
Zhijun GAO ; Jianjun LI ; Yin CAI ; Yana REN ; Mengchen XIE ; Lan ZHENG ; Guoping ZHOU
Journal of Modern Laboratory Medicine 2025;40(3):199-202
Objective To evaluate the application of ELISA randomized quality control,and continuously improve the laboratory testing capacity and quality assurance,in order to gradually improve the application of randomized quality control to the daily testing of ELISA.Methods Collected the quality control data of KEHUA HBsAg,compared the difference between randomized quality control data and immobilized quality control data.Group comparison of randomization quality control between rows and columns.The randomized quality control data were analyzed retrospectively and the quality control chart was established by using the randomized quality control data.Analyzed and compared the lost-control situation of randomized quality control and immobilized quality control.Results Randomized quality control S/CO value(2.831±0.343)and immobilized quality control S/CO value(2.651±0.260)in the same microplate,the difference between two was statistically significant(t=5.970,P<0.05).The differences between randomized quality control and immobilized quality control in columns 2 to 8 were statistically significant(t=2.285~5.536,all P<0.05).There were no statistically significant differences between randomized quality control and immobilized quality control in column 9 to 12(t=0.031~1.605,all P>0.05).There was no statistically significant difference in randomization quality control among all lines(F=0.858,P>0.05).The randomized quality control data was used to establish a quality control chart.Within the time range of the collected data,the randomized quality control was out of control for 6 times,all were greater than+3s,and the loss of control rate was 4.72%(6/127).Fixed position quality control lost control 9 times during the same period,all of which were greater than+3s,with a loss of control rate of 0.61%(9/1 481).Conclusion The randomized quality control has a greater possibility to reflect the factors affecting all the samples on the microporous plate.Random quality control can be used to find possible systematic errors in testing.Randomized quality control can gradually be fully applied to daily indoor quality control,but the loss of control rate and coefficient of variation may increase.
4.Clinical outcomes of small-size grafts in auxiliary liver transplantation for the treatment of portal hypertension
Hongfei JU ; Lin WEI ; Liying SUN ; Wei QU ; Zhigui ZENG ; Haiming ZHANG ; Yule TAN ; Jun WANG ; Fuxiao XIE ; Zhijun ZHU
Chinese Journal of Hepatology 2025;33(11):1050-1057
Objective:To evaluate the safety and efficacy of using small and ultra-small sized grafts for in situ auxiliary liver transplantation in the treatment of portal hypertension.Methods:A prospective single-arm cohort study was conducted. Patients who underwent liver transplantation at Beijing Friendship Hospital from December 2014 to July 2025 were included. Intraoperative portal vein pressure was routinely monitored, with the target regulation for portal vein blood flow set at<15 mmHg (1 mmHg=0.133 kPa) and follow-up continued until September 2025. The primary endpoints were the patient's status and graft survival. The secondary endpoints were small-for-size syndrome and perioperative complications. The small-for-size syndrome was graded according to the 2023 International Liver Transplantation Society consensus statement.Results:A total of 33 cases were enrolled. Among them, 22 had ultra-small size grafts, 11 had small-size grafts, 28 had living donor grafts, and five had split grafts. The graft-to-recipient weight ratio in living donor liver transplantation was 0.31%~0.79%, while in split liver transplantation it was 0.45%~1.02%. Intraoperative portal vein pressure of ≥15 mmHg was observed in 11 cases, who underwent portal vein blood flow adjustment via splenic artery ligation (2 cases), partial splenectomy (8 cases), and/or restrictive portocaval shunting (1 case), after which all patients achieved the target portal vein pressure. All cases completed at least one month of follow-up, with 28 cases following for more than one year, and the median follow-up period was 36.5 months. Early-stage postoperative small-for-size syndrome occurred in eight cases (24.2%, 8/33), all classified as grade A, with improvements following supportive treatment. Severe complications (Clavien-Dindo≥Ⅲ) occurred in three cases (9.1%, 3/33). The one-year survival rate was 92.9% (26/28). The overall survival rate at the end of follow-up was 90.9% (30/33). No patients experienced graft loss or death due to small-for-size syndrome. Graft tissue tested negative for hepatitis B core antibody and covalently closed circular DNA, and hepatitis B surface antigen seroconversion was achieved following second-stage residual liver resection and under a combined strategy of potent nucleos(t)ide analogs and hepatitis B immunoglobulin in ten cases of hepatitis B-related disease.Conclusions:With standardized portal vein blood flow monitoring and individualized portal vein blood flow adjustment, in situ auxiliary liver transplantation can safely and effectively use small and even ultra-small sized grafts, thereby significantly expanding graft sources and ensuring donor and recipient safety. These findings warrant further validation and promotion in multicenter controlled studies.
5.Effect of timing of minimally invasive puncture and drainage on the outcome of patients with hypertensive intracerebral hemorrhage in basal ganglia region
Yanhua WANG ; Teng XIE ; Xiaoping YU ; Zhijun HUANG ; Wen LIU
International Journal of Cerebrovascular Diseases 2025;33(2):108-112
Objective:To investigate the correlation between the timing of minimally invasive puncture drainage and the outcome of patients with hypertensive intracerebral hemorrhage (HICH) in the basal ganglia region.Methods:Patients with HICH in the basal ganglia region underwent minimally invasive puncture and drainage at Hanchuan People's Hospital from January 2019 to September 2023 were selected. According to the timing of surgery, the patients were divided into onset to surgery time ≤12-hour group and >12-hour group. According to the modified Rankin Scale score at 90 days after onset, they were divided into a good outcome group (0-2) and a poor outcome group (>2). Multivariate logistic regression analysis was used to evaluate the independent influencing factors of functional outcome. Results:A total of 150 patients were included, with 78 males (52.00%), aged 53.15±4.35 years (range, 40-75 years). Eighty-six patients (57.33%) underwent surgery within 12 hours after onset, while 64 (42.67%) underwent surgery after 12 hours; 97 patients (64.67%) had good outcome, while 53 (35.33%) had poor outcome. Univariate analysis showed that compared with the onset to surgery time ≤12-hour group, the onset to surgery time >12-hour group had a longer time from onset to admission, a larger postoperative hematoma volume, longer hospitalization time, lower postoperative hematoma clearance rate, and a higher proportion of patients with poor outcome and deaths within 90 days (all P<0.05). Compared with the good outcome group, the poor outcome group had a longer time from onset to admission, higher baseline National Institutes of Health Stroke Scale (NIHSS) scores, larger baseline and postoperative hematoma volumes, and a higher proportion of patients with onset to surgery time >12 hours. However, the postoperative hematoma clearance rate, baseline Glasgow Coma Scale (GCS) score, and the proportion of patients with baseline GCS score >8 was lower in the poor outcome group (all P<0.05). Multivariate logistic regression analysis showed that the higher baseline NIHSS score (odds ratio [ OR] 1.847, 95% confidence interval [ CI] 1.362-2.503; P=0.001) and the time from onset to surgery >12 hours (compared with ≤12 hours: OR 1.347, 95% CI 1.058-1.715; P=0.016) were the independent risk factors for poor outcome, while higher baseline GCS scores ( OR 0.723, 95% CI 0.558-0.937; P=0.006) and higher postoperative hematoma clearance rates ( OR 0.615, 95% CI 0.462-0.819; P=0.004) were the independent protective factors for good outcome. Conclusion:In patients with HICH in basal ganglia, it is ideal to perform minimally invasive puncture and drainage within 12 h after onset, and the postoperative recovery is relatively better.
6.Clinical outcomes of small-size grafts in auxiliary liver transplantation for the treatment of portal hypertension
Hongfei JU ; Lin WEI ; Liying SUN ; Wei QU ; Zhigui ZENG ; Haiming ZHANG ; Yule TAN ; Jun WANG ; Fuxiao XIE ; Zhijun ZHU
Chinese Journal of Hepatology 2025;33(11):1050-1057
Objective:To evaluate the safety and efficacy of using small and ultra-small sized grafts for in situ auxiliary liver transplantation in the treatment of portal hypertension.Methods:A prospective single-arm cohort study was conducted. Patients who underwent liver transplantation at Beijing Friendship Hospital from December 2014 to July 2025 were included. Intraoperative portal vein pressure was routinely monitored, with the target regulation for portal vein blood flow set at<15 mmHg (1 mmHg=0.133 kPa) and follow-up continued until September 2025. The primary endpoints were the patient's status and graft survival. The secondary endpoints were small-for-size syndrome and perioperative complications. The small-for-size syndrome was graded according to the 2023 International Liver Transplantation Society consensus statement.Results:A total of 33 cases were enrolled. Among them, 22 had ultra-small size grafts, 11 had small-size grafts, 28 had living donor grafts, and five had split grafts. The graft-to-recipient weight ratio in living donor liver transplantation was 0.31%~0.79%, while in split liver transplantation it was 0.45%~1.02%. Intraoperative portal vein pressure of ≥15 mmHg was observed in 11 cases, who underwent portal vein blood flow adjustment via splenic artery ligation (2 cases), partial splenectomy (8 cases), and/or restrictive portocaval shunting (1 case), after which all patients achieved the target portal vein pressure. All cases completed at least one month of follow-up, with 28 cases following for more than one year, and the median follow-up period was 36.5 months. Early-stage postoperative small-for-size syndrome occurred in eight cases (24.2%, 8/33), all classified as grade A, with improvements following supportive treatment. Severe complications (Clavien-Dindo≥Ⅲ) occurred in three cases (9.1%, 3/33). The one-year survival rate was 92.9% (26/28). The overall survival rate at the end of follow-up was 90.9% (30/33). No patients experienced graft loss or death due to small-for-size syndrome. Graft tissue tested negative for hepatitis B core antibody and covalently closed circular DNA, and hepatitis B surface antigen seroconversion was achieved following second-stage residual liver resection and under a combined strategy of potent nucleos(t)ide analogs and hepatitis B immunoglobulin in ten cases of hepatitis B-related disease.Conclusions:With standardized portal vein blood flow monitoring and individualized portal vein blood flow adjustment, in situ auxiliary liver transplantation can safely and effectively use small and even ultra-small sized grafts, thereby significantly expanding graft sources and ensuring donor and recipient safety. These findings warrant further validation and promotion in multicenter controlled studies.
7.Experimental Evaluation of the Clinical Laboratory ELISA Assay Using A Randomization Quality Control Method for Indoor Quality Control
Zhijun GAO ; Jianjun LI ; Yin CAI ; Yana REN ; Mengchen XIE ; Lan ZHENG ; Guoping ZHOU
Journal of Modern Laboratory Medicine 2025;40(3):199-202
Objective To evaluate the application of ELISA randomized quality control,and continuously improve the laboratory testing capacity and quality assurance,in order to gradually improve the application of randomized quality control to the daily testing of ELISA.Methods Collected the quality control data of KEHUA HBsAg,compared the difference between randomized quality control data and immobilized quality control data.Group comparison of randomization quality control between rows and columns.The randomized quality control data were analyzed retrospectively and the quality control chart was established by using the randomized quality control data.Analyzed and compared the lost-control situation of randomized quality control and immobilized quality control.Results Randomized quality control S/CO value(2.831±0.343)and immobilized quality control S/CO value(2.651±0.260)in the same microplate,the difference between two was statistically significant(t=5.970,P<0.05).The differences between randomized quality control and immobilized quality control in columns 2 to 8 were statistically significant(t=2.285~5.536,all P<0.05).There were no statistically significant differences between randomized quality control and immobilized quality control in column 9 to 12(t=0.031~1.605,all P>0.05).There was no statistically significant difference in randomization quality control among all lines(F=0.858,P>0.05).The randomized quality control data was used to establish a quality control chart.Within the time range of the collected data,the randomized quality control was out of control for 6 times,all were greater than+3s,and the loss of control rate was 4.72%(6/127).Fixed position quality control lost control 9 times during the same period,all of which were greater than+3s,with a loss of control rate of 0.61%(9/1 481).Conclusion The randomized quality control has a greater possibility to reflect the factors affecting all the samples on the microporous plate.Random quality control can be used to find possible systematic errors in testing.Randomized quality control can gradually be fully applied to daily indoor quality control,but the loss of control rate and coefficient of variation may increase.
8.Mechanism Evolution of Latent Toxin in Systemic Lupus Erythematosus and Syndrome Differentiation and Treatment
Yi ZHANG ; Zhijun XIE ; Lin HUANG ; Qiao WANG ; Haichang LI ; Chengping WEN
Journal of Traditional Chinese Medicine 2024;65(16):1721-1724
It is proposed that the disease mechanism evolution of systemic lupus erythematosus can be summarized into four stages: initial invasion and latency, the pathogenesis remains concealing; latent toxin accumulation, the disease gradually becomes apparent; active toxin begins damaging, the disease manifests aggressively; damage resulting to deficiency, the disease course prolonged. Based on the stages of latent toxin evolution, the syndrome differentiation and treatment of systemic lupus erythematosus can be summarized as follows: during the initial latent stage, characterized by latent dampness and heat stagnation, modified Sanren Decoction (三仁汤) should be used; in the toxin outbreak stage, marked by intense heat toxin, modified Xijiao Dihuang Decoction (犀角地黄汤) combined with modified Qingwen Baidu Decoction (清瘟败毒饮) should be used; during the toxin damage stage, which presents as latent toxin damaging zang-fu organs, modified Qinghao Biejia Decoction (青蒿鳖甲汤) should be used; in the healthy qi deficiency stage, characterized by deficiencies of qi, blood, yin, and yang, modified Xieli Shiquan Ointment (燮理十全膏) should be used.
9.Xiaozhong-Zhitong mixture induces M2 polarization of mouse microglia by inhibiting TLR4/MyD88/NF-κB signaling pathway
Jing XIE ; Zhijun HE ; Tao LIU ; Xiaotao WEI ; Weiwei WANG ; Yuanyuan SONG ; Huiqing TIAN
Chinese Journal of Pathophysiology 2024;40(9):1589-1597
AIM:To investigate the effects of Xiaozhong-Zhitong mixture(XZZT)on M2 polarization and Toll-like receptor 4(TLR4)/myeloid differentiation factor 88(MyD88)/nuclear factor-κB(NF-κB)signaling pathway in mouse microglia(BV2 cells).METHODS:The BV2 cells were divided into 5 groups:blank group,model group[lipo-polysaccharide(LPS)+hypoxia],TAK-242(resatorvid,a TLR4 inhibitor)group(LPS+hypoxia+TAK-242),XZZT group(LPS+hypoxia+XZZT),and TAK-242+XZZT group(LPS+hypoxia+TAK-242+XZZT).Flow cytometry was used to detect early apoptosis and cell cycle of BV2 cells,and immunofluorescence staining was employed to detect the positive expres-sion of M1-type marker inducible nitric oxide synthase(iNOS)and M2-type marker CD206.Western blot was utilized to detect the expression of TLR4/MyD88/NF-κB signaling pathway-related proteins,including TLR4,MyD88,NF-κB p65,phosphorylated p65(p-p65),phosphorylated transforming growth factor-β-activated kinase 1(p-TAK1),and phosphory-lated IκB kinase α/β(p-IKKα/β).RT-qPCR was used to detect the mRNA expression of interleukin-1β(IL-1β),IL-10,tumor necrosis factor-α(TNF-α),TLR4,MyD88,and NF-κB p65.RESULTS:Compared with model group,the rate of early apoptosis was significantly decreased in XZZT group(P<0.01),the percentage of cells arrested in the S phase was significantly increased(P<0.01),and the protein levels of TLR4,MyD88,NF-κB p65,p-IKKα/β,p-p65,and p-TAK1 were significantly decreased(P<0.05 or P<0.01).Additionally,IL-1β,TNF-α,TLR4,MyD88 and NF-κB p65 mRNA expression levels were significantly decreased(P<0.05 or P<0.01),while IL-10 mRNA expression was significantly in-creased(P<0.05).Compared with TAK-242 group,the average percentage of iNOS positive area was significantly de-creased,while CD206 was significantly increased in TAK-242+XZZT group(P<0.01).CONCLUSION:The XZZT has the effect of inducing M2 polarization of mouse microglia,and the mechanism may be linked to the inhibition of TLR4/MyD88/NF-κB signaling pathway.
10.Research progress of optical coherence tomography biomarkers in macular edema secondary to retinal vein occlusion
Yang LI ; Ying XIE ; Zhijun DONG
International Eye Science 2024;24(6):912-916
Retinal vein occlusion(RVO)is the second most common cause of vision loss due to retinal vascular disease. Macular edema(ME)is a common complication of RVO and a major cause of central vision impairment. Optical coherence tomography(OCT)is a high-resolution imaging technique that can provide detailed cross-sectional images of the retina and choroid. OCT biomarkers play an important role in the early and accurate diagnosis of RVO-ME, prediction of disease progression, and assessment of visual prognosis. This article provides an overview of various OCT biomarkers for RVO-ME, including retinal thickness, disorganization of retinal inner layers, hyper-reflectivity of retinal inner layer, the integrity of external limiting membrane and ellipsoid zone, the third highest reflectance band of the fovea, hyperreflective dots, paracentral acute middle maculopathy, prominent middle limiting membrane sign, serous retinal detachment height, macular volume and choroidal thickness. These biomarkers serve as objective indicators for evaluating the severity of RVO-ME, guiding treatment decisions, and predicting visual outcomes.

Result Analysis
Print
Save
E-mail