1.Textual analysis of provincial policy on nursing assistant training and management in China
Aihong MING ; Xiuhong LONG ; Zhijin LIANG ; Li LI ; Fengmin LI ; Sihui LIN ; Yunfan YANG ; Zhihui WANG ; Tian FENG
Chinese Journal of Nursing 2025;60(8):960-967
Objective To analyze the deployment of policy instruments and the distribution of stakeholder engagement in provincial policies on nursing assistant training and management.Methods The relevant policy texts on nursing assistant training and management were systematically searched and collected from the official websites of provincial governments and their direct departments,CNKI,and the PKU Law Database.A two-dimensional framework of policy instruments-stakeholder was constructed,and the content analysis was used to classify,encode and quantify policy clauses.Results The study encompassed 20 provincial-level nursing assistant training and management policies,yielding a total of 359 codes.Within the policy instruments dimension,environmental,supply,and demand instruments constituted 66.30%,28.97%,and 4.74%,respectively.In terms of stakeholders,the management-side accounted for 56.55%,providers and trainers for 18.11%each,partners for 5.01%,and demand-side for 2.23%.Both management-side and trainers engaged with 3 policy instruments,providers with 2,and partners and demand-side with one each.Conclusion In the provincial nursing assistant training and management policies,there are differences in the deployment of policy instruments,and the distribution of stakeholders is uneven.Managers should pay attention to publicity guidance and platform construction,improve incentive mechanisms and training programs,and innovate cooperation models with stakeholders,as well as strengthen communication and exchange.
2.Textual analysis of provincial policy on nursing assistant training and management in China
Aihong MING ; Xiuhong LONG ; Zhijin LIANG ; Li LI ; Fengmin LI ; Sihui LIN ; Yunfan YANG ; Zhihui WANG ; Tian FENG
Chinese Journal of Nursing 2025;60(8):960-967
Objective To analyze the deployment of policy instruments and the distribution of stakeholder engagement in provincial policies on nursing assistant training and management.Methods The relevant policy texts on nursing assistant training and management were systematically searched and collected from the official websites of provincial governments and their direct departments,CNKI,and the PKU Law Database.A two-dimensional framework of policy instruments-stakeholder was constructed,and the content analysis was used to classify,encode and quantify policy clauses.Results The study encompassed 20 provincial-level nursing assistant training and management policies,yielding a total of 359 codes.Within the policy instruments dimension,environmental,supply,and demand instruments constituted 66.30%,28.97%,and 4.74%,respectively.In terms of stakeholders,the management-side accounted for 56.55%,providers and trainers for 18.11%each,partners for 5.01%,and demand-side for 2.23%.Both management-side and trainers engaged with 3 policy instruments,providers with 2,and partners and demand-side with one each.Conclusion In the provincial nursing assistant training and management policies,there are differences in the deployment of policy instruments,and the distribution of stakeholders is uneven.Managers should pay attention to publicity guidance and platform construction,improve incentive mechanisms and training programs,and innovate cooperation models with stakeholders,as well as strengthen communication and exchange.
3.Clinical effects of free bilateral turbocharged anterolateral thigh flaps in tandem in repairing extensive wounds in the foot and ankle
Liang YANG ; Rong ZHOU ; Jihui JU ; Zefeng NIU ; Zhongzheng LIU ; Liping GUO ; Zhijin LIU ; Qianheng JIN ; Chengwei GE ; Guiyang WANG ; Lin YANG ; Junnan CHENG
Chinese Journal of Burns 2025;41(1):61-69
Objective:To explore the clinical effects of free bilateral turbocharged anterolateral thigh flaps in tandem in repairing extensive wounds in the foot and ankle.Methods:The study was a retrospective observational study. From April 2020 to June 2023, 12 patients with extensive wounds in the foot and ankle who met the inclusion criteria were admitted to the Department of Wound Repair Surgery of Suzhou Ruihua Orthopedic Hospital, including 8 males and 4 females, aged 21 to 65 years. The wound area after debridement ranged from 27 cm×14 cm to 37 cm×20 cm. The bilateral perforator flaps pedicled with either oblique or descending branches of the lateral circumflex femoral artery were designed and harvested based on the size and shape of the wounds. The individual flap incision area ranged from 16 cm×9 cm to 34 cm×12 cm. The non-homologous perforator of the flap on the one side was turbocharged by anastomosing it with the gross muscular branch or main vessel of the oblique or descending branch of the lateral circumflex femoral artery from the flap. Subsequently, the proximal end of the oblique or descending branch of the lateral circumflex femoral artery and its accompanying vein from the flap on the one side were connected end-to-end with either the anterior tibial artery and vein, posterior tibial artery and vein, or dorsal foot artery and vein in the recipient area, the distal end of the oblique or descending branch of the lateral circumflex femoral artery and its accompanying vein from the flap on the one side were anastomosed end-to-end with a source vessel originating from flap on the other side. The wounds in the flap donor areas were sutured directly. The number and source of perforators carried by the flaps and the duration of the flap repair surgery were recorded. The survival of the flap, the occurrence of vascular crisis, and the wound healing at both donor and recipient areas were observed after surgery. The flap condition, appearance and function of the affected limb were observed during follow-up. At the last follow-up, the sensory function of the flap was assessed using the British Medical Research Council's sensory rating standard, the foot and ankle function of the affected limb was evaluated according to the American Orthopedic Foot and Ankle Society scoring standard.Results:A total 24 flaps were successfully harvested, carrying 60 perforators, including 34 perforators from the oblique branch of the lateral circumflex femoral artery, 24 perforators from the descending branch of the lateral circumflex femoral artery, one perforator from the transverse branch of the lateral circumflex femoral artery, and one perforator from the direct branch of the femoral artery. The duration of the flap repair surgery ranged from 4.2 to 9.0 hours. The flaps of 12 patients exhibited complete survival after surgery. A total of two flaps of two patients experienced venous crisis after surgery but survived through emergency exploration. One patient encountered undesirable wound healing at the donor area of flap on the one side after surgery, which healed after dressing change, debridement, and suturing. The remaining patients' donor area wounds healed. Two patients displayed impaired wound healing in the recipient area, which improved after dressing change and resection of residual sequestrum, and the wounds in the recipient area of other patients healed successfully. During the follow-up of 4-26 months, the flaps demonstrated favorable color and texture, slight edematous appearance, and partial sensory recovery, as well as good aesthetic and functional restoration of the affected limbs. At the last follow-up, the sensory function of the flap was assessed as grade S2 in 9 cases and grade S3 in 3 cases; the foot and ankle function of the affected limb was evaluated as excellent in two cases, good in 9 cases, and fair in one case.Conclusions:The bilateral turbocharged anterolateral thigh flaps have numerous sources of perforators. By implementing supercharging of non-homologous perforators within the flap, the vascular supply to the flap is turbocharged, thereby mitigating the risk of extensive flap necrosis. The flap is an effective approach for repairing extensive wounds in the foot and ankle, resulting in improved function of the affected limb after repair.
4.Clinical effects of free bilateral turbocharged anterolateral thigh flaps in tandem in repairing extensive wounds in the foot and ankle
Liang YANG ; Rong ZHOU ; Jihui JU ; Zefeng NIU ; Zhongzheng LIU ; Liping GUO ; Zhijin LIU ; Qianheng JIN ; Chengwei GE ; Guiyang WANG ; Lin YANG ; Junnan CHENG
Chinese Journal of Burns 2025;41(1):61-69
Objective:To explore the clinical effects of free bilateral turbocharged anterolateral thigh flaps in tandem in repairing extensive wounds in the foot and ankle.Methods:The study was a retrospective observational study. From April 2020 to June 2023, 12 patients with extensive wounds in the foot and ankle who met the inclusion criteria were admitted to the Department of Wound Repair Surgery of Suzhou Ruihua Orthopedic Hospital, including 8 males and 4 females, aged 21 to 65 years. The wound area after debridement ranged from 27 cm×14 cm to 37 cm×20 cm. The bilateral perforator flaps pedicled with either oblique or descending branches of the lateral circumflex femoral artery were designed and harvested based on the size and shape of the wounds. The individual flap incision area ranged from 16 cm×9 cm to 34 cm×12 cm. The non-homologous perforator of the flap on the one side was turbocharged by anastomosing it with the gross muscular branch or main vessel of the oblique or descending branch of the lateral circumflex femoral artery from the flap. Subsequently, the proximal end of the oblique or descending branch of the lateral circumflex femoral artery and its accompanying vein from the flap on the one side were connected end-to-end with either the anterior tibial artery and vein, posterior tibial artery and vein, or dorsal foot artery and vein in the recipient area, the distal end of the oblique or descending branch of the lateral circumflex femoral artery and its accompanying vein from the flap on the one side were anastomosed end-to-end with a source vessel originating from flap on the other side. The wounds in the flap donor areas were sutured directly. The number and source of perforators carried by the flaps and the duration of the flap repair surgery were recorded. The survival of the flap, the occurrence of vascular crisis, and the wound healing at both donor and recipient areas were observed after surgery. The flap condition, appearance and function of the affected limb were observed during follow-up. At the last follow-up, the sensory function of the flap was assessed using the British Medical Research Council's sensory rating standard, the foot and ankle function of the affected limb was evaluated according to the American Orthopedic Foot and Ankle Society scoring standard.Results:A total 24 flaps were successfully harvested, carrying 60 perforators, including 34 perforators from the oblique branch of the lateral circumflex femoral artery, 24 perforators from the descending branch of the lateral circumflex femoral artery, one perforator from the transverse branch of the lateral circumflex femoral artery, and one perforator from the direct branch of the femoral artery. The duration of the flap repair surgery ranged from 4.2 to 9.0 hours. The flaps of 12 patients exhibited complete survival after surgery. A total of two flaps of two patients experienced venous crisis after surgery but survived through emergency exploration. One patient encountered undesirable wound healing at the donor area of flap on the one side after surgery, which healed after dressing change, debridement, and suturing. The remaining patients' donor area wounds healed. Two patients displayed impaired wound healing in the recipient area, which improved after dressing change and resection of residual sequestrum, and the wounds in the recipient area of other patients healed successfully. During the follow-up of 4-26 months, the flaps demonstrated favorable color and texture, slight edematous appearance, and partial sensory recovery, as well as good aesthetic and functional restoration of the affected limbs. At the last follow-up, the sensory function of the flap was assessed as grade S2 in 9 cases and grade S3 in 3 cases; the foot and ankle function of the affected limb was evaluated as excellent in two cases, good in 9 cases, and fair in one case.Conclusions:The bilateral turbocharged anterolateral thigh flaps have numerous sources of perforators. By implementing supercharging of non-homologous perforators within the flap, the vascular supply to the flap is turbocharged, thereby mitigating the risk of extensive flap necrosis. The flap is an effective approach for repairing extensive wounds in the foot and ankle, resulting in improved function of the affected limb after repair.
5.Distribution characteristics and clinical application of perforators of anterolateral thigh flap pedicled with oblique branch of lateral circumflex femoral artery
Lin YANG ; Yang CAO ; Junnan CHENG ; Yongtao HUANG ; Zhijin LIU ; Qinfeng GAO ; Chengpeng YANG ; Fengwen SUN ; Yucheng LIU ; Jihui JU
Chinese Journal of Plastic Surgery 2023;39(5):463-471
Objective:To explore the distribution characteristics of the perforators of the oblique branch of the lateral circumflex femoral artery, and to report the clinical effect of the anterolateral thigh flap pedicled with the oblique branch in repairing the wounds of the extremities.Methods:The clinical data of the patients with anterolateral thigh flap pedicled with oblique branch of lateral circumflex femoral artery in Suzhou Ruihua Orthopaedic Hospital from December 2020 to April 2021 were analyzed retrospectively. High frequency color Doppler ultrasound was used to detect the large perforators of the oblique branch of the lateral circumflex femoral artery near the midpoint of the line between the anterior superior iliac spine and the lateral margin of the patella. With reference to the location of the perforators, according to the size and shape of the defect in the recipient area, the anterolateral thigh flap pedicled with oblique branch was designed and dissected to repair the wound. During the operation, the distance between the emitting point of the main oblique branch, the skin entry point of the perforators and the anterior superior iliac spine was measured with a steel ruler, the diameter of the perforators was measured with a microscale, and the number of perforators was counted. The survival and complications of the flap were observed and followed up after operation. In the last follow-up, the comprehensive evaluation scale was used to evaluate the repair effect: 90 to 100 points is excellent, 75 to 89 points is good, 60 to 74 points is average, and less than 60 points is poor.Results:A total of 84 patients were included, including 62 males and 22 females, aged from 14 to 82 years (mean 46.9 years), including 32 cases of hand wounds, 6 cases of forearm wounds, 3 cases of upper arm wounds, 10 cases of calves and 33 cases of foot and ankle wounds. The wound area was 6 cm × 4 cm-20 cm × 45 cm. A total of 88 flaps were removed in 84 patients (skin flaps on both thighs were removed in 4 patients). The size of the skin flap of 88 thighs was 7 cm × 5 cm-37 cm × 11 cm, of which 85 sides of 82 cases survived completely. One case of diabetes had complete necrosis 1 month after operation, and 1 case of 34 cm had necrosis of the distal end of 3 cm × 3 cm skin flap. Necrotic skin flaps were repaired with skin grafting. Four patients developed arterial crisis within 24 hours after operation, and those flaps survived after surgical exploration. All donor areas healed. During the follow-up of 6 to 9 months, the shape of the recipient area was normal in all patients, and there was no deep tissue infection such as osteomyelitis. The color and texture of all flaps were good. The sensation returned to S1-S2 after operation. The skin flap comprehensive evaluation scale was used to evaluate the repair effect. The patients’ score ranged from 73 to 94 points, with an average of 88.1 points. Including 33 excellent cases, 46 good cases and 5 average cases, the excellent and good rate was 94.0%(79/84). A total of 215 perforators were marked with 88 flaps before operation, and 208 perforators were found during the operation(the diameter of the perforators was 0.4-1.5 mm), of which 130 were sent out by oblique branches. There were perforators of the oblique branch in all flaps, with an average of 1.5 on each side, including 84(64.6%) septocutaneous perforators and 46(35.4%) musculocutaneous perforators. Most of the oblique branches originate from the lateral circumflex femoral artery, which runs in the intermuscular septum between the rectus femoris and the intermediate femoris muscle. It is divided into deep branches and superficial branches at the middle and upper 1/3 junction of the line between the anterior superior iliac spine and the lateral margin of the patella. The skin perforators of the oblique branch of the lateral circumflex femoral artery is mostly sent out from the superficial branch, and there are 118 perforators located at the midpoint and proximal end of the line between the anterior superior iliac spine and the lateral margin of the patella, accounting for 90.8% (118/130), reaching a peak at 0.4 (there are 37 perforators).Conclusion:The oblique branch of the lateral circumflex femoral artery is relatively constant, and most of the perforators are located near the midpoint of the line between the anterior superior iliac spine and the lateral margin of the patella, and the proportion of septocutaneous perforator is high. The distribution of perforator is regular, the blood supply is reliable, the application mode is flexible, and the donor site position is more concealed while the blood supply of the flap is secured.
6.Curative effects of the superficial peroneal artery perforator flap carrying multiple perforators in repairing hand and foot wounds
Tao ZHANG ; Junnan CHENG ; Lin YANG ; Yongtao HUANG ; Qinfeng GAO ; Fengwen SUN ; Zhijin LIU ; Shengzhe LIU ; Chengpeng YANG ; Yang CAO ; Jihui JU
Chinese Journal of Burns 2023;39(3):234-240
Objective:To investigate the curative effects of the superficial peroneal artery perforator flap carrying two and more homologous perforators in repairing hand and foot wounds.Methods:A retrospective observational study was conducted. From January to September 2021, 23 patients with hand and foot wounds combined with bone or tendon exposure who met the inclusion criteria were admitted to Suzhou Ruihua Orthopaedic Hospital, including 16 males and 7 females, aged 23 to 68 years. After expansion of the wound, the wound area was 3.0 cm×2.0 cm to 11.0 cm×4.0 cm. All the wounds were repaired with the superficial peroneal artery perforator flap carrying two and more homologous perforators. The area of the resected flap was 4.0 cm×2.0 cm to 12.0 cm×5.0 cm. All the wounds in donor areas were sutured directly. During the operation, the resection of the flap, the number and caliber of carried perforators, the caliber of superficial peroneal artery, the length of vascular pedicle, and the number of accompanying veins of the superficial peroneal artery were recorded. The survival of the flap, the occurrence of complications, and the wound healing in the donor area were observed after operation. The recovery of the donor and recipient areas was followed up. At the last follow-up, the comprehensive evaluation scale was used to evaluate the curative effect of flap repair, and the sensory grading scale was used to evaluate the sensory function of the recipient area.Results:Totally 24 flaps were successfully resected in surgical operations, carrying 56 superficial peroneal artery perforators in total, with the caliber of perforators of 0.20-0.70 mm. The calibers of all perforators carried by 7 flaps were smaller than 0.40 mm. Nineteen flaps carried 2 perforators each, 3 flaps carried 3 perforators each, 1 flap carried 4 perforators, and 1 flap carried 5 perforators. During the operation, the superficial peroneal artery was resected with a caliber of 0.40-1.50 mm, the vascular pedicle was 2-6 cm in length, and each superficial peroneal artery had two accompanying veins. After operation, all the flaps survived smoothly, no vascular crisis or distal necrosis occurred, and the wounds healed well in the donor area. During the follow-up of 6 to 10 months after operation, the color, texture, and elasticity of the recipient area were good. Among them, 6 recipient areas were thinned and reshaped because of bloating. There was only linear scar and no obvious scar hyperplasia or pigmentation in the donor area, without significant change in sensory or motor function. At the last follow-up, the curative effect evaluation of flap repair was excellent in 22 flaps and good in 2 flaps, and the sensory function evaluation of the recipient area was grade S 3 in 1 area and grade S 2 in 23 areas. Conclusions:The superficial peroneal artery perforator flap with two and more homologous perforators has sufficient and reliable blood supply and is effective in repairing hand and foot wounds. It provides an ideal solution for the clinical problem in which the original operation scheme is abandoned due to the existence of only multiple slender perforators of caliber smaller than 0.40 mm, and only a single perforator in the operative field that cannot satisfy the needs of the flap blood supply and recipient area.
7.Effects of bilobated superficial peroneal artery perforator flap in repairing two adjacent wounds of the fingers
Tao ZHANG ; Junnan CHENG ; Lin YANG ; Fengwen SUN ; Qinfeng GAO ; Yongtao HUANG ; Chengpeng YANG ; Yang CAO ; Zhijin LIU ; Jihui JU
Chinese Journal of Burns 2023;39(7):655-661
Objective:To investigate the therapeutic efficacy of bilobated superficial peroneal artery perforator flap in repairing two adjacent wounds of the fingers.Methods:A retrospective observational study was conducted. From January 2021 to January 2022, 15 patients with two adjacent wounds of the fingers who met the inclusion criteria were hospitalized in Suzhou Ruihua Orthopaedic Hospital, including 10 males and 5 females, aged 25 to 51 years. The area of single wound after debridement was from 2.5 cm×2.0 cm to 7.5 cm×2.5 cm. All the wounds were repaired by the bilobated superficial peroneal artery perforator flap from the lower leg. The single lobe area of bilobated flap was from 3.0 cm×2.0 cm to 8.0 cm×3.0 cm. The wounds in all the donor sites were sutured directly. During the operation, the number of resected flaps, the number and type of carried perforators were recorded, and the calibers of perforator and superficial peroneal artery and the length of vascular pedicle were measured. The survival of flap and the wound healing in the donor and recipient sites were recorded after operation. The recovery of donor and recipient sites were recorded during follow-up. At the last follow-up, the repair effect of flap was evaluated by the comprehensive evaluation scale, and the sensory function of flap was evaluated by the sensory function evaluation standard of British Medical Research Association.Results:During the operation, 15 bilobated flaps were successfully resected, carrying 36 superficial peroneal artery perforators, all of which were septocutaneous perforators with the caliber of 0.2-0.8 mm. The caliber of superficial peroneal artery was 0.4-1.1 mm and the length of vascular pedicle was 3-8 cm. After operation, all the flaps survived with no vascular crisis occurred, and the wounds in donor and recipient sites healed well. During the follow-up of 6 to 12 months, the color and texture of flaps were similar to those of normal tissue in the hand and the appearance of flap was good in 10 cases; the other 5 cases underwent the stage Ⅱ flap thinning and plastic surgery 6 months after operation due to the bloated appearance of flaps. There was only linear scar in the donor site of lower leg, with no obvious scar hyperplasia or pigmentation, and there was no obvious adverse effect on the sensation or motor function of the distal limbs in the donor area. At the last follow-up, the repair effect of flap of 15 patients was excellent in 11 cases and good in 4 cases, and the sensory function of the flap was evaluated as grade S 2 in all cases. Conclusions:The bilobated superficial peroneal artery perforator flap has high proportion of septocutaneous perforator, and the blood supply is sufficient and reliable. Using this flap to repair two adjacent wounds of the fingers causes minimal damage to the donor area, only one group of blood vessels is needed to be anastomosed to repair two wounds, the difficulty of microoperation is reduced, and good flap repair effect and sensory function can be obtained.
8.Clinical effects of anterolateral thigh flap with blood supply source of medial femoral perforator in repairing the wounds on extremities
Chengpeng YANG ; Linfeng TANG ; Zhijin LIU ; Shengzhe LIU ; Lin YANG ; Junnan CHENG ; Tao ZHANG ; Fengwen SUN ; Yongtao HUANG ; Qinfeng GAO ; Jihui JU
Chinese Journal of Burns 2023;39(9):842-848
Objective:To investigate clinical effects of anterolateral thigh flap with blood supply source of medial femoral perforator in repairing the wounds on extremities.Methods:A retrospective observational study was conducted. From October 2018 to June 2021, Suzhou Ruihua Orthopedic Hospital admitted 12 patients (11 males and 1 female, aged 24-64 years) who met the inclusion criteria, and did not have the lateral circumflex femoral artery during anterolateral thigh flap resection, or changed to medial femoral perforator as a source of blood supply due to small perforator to repair the wound with flap transplantation. The wounds were on the upper limbs in 7 cases and on the lower limbs in 5 cases. The wound area after debridement was 8.0 cm×5.0 cm-24.0 cm×6.5 cm, and the applied flap area was 9 cm×6 cm-25 cm×7 cm. During transplantation, the perforating branch or source artery of the flap was anastomosed end to end with the vascular pedicle of the recipient area. Subcutaneous beauty suture was performed on all the donor wounds. After operation, the survival of the flap and vascular crisis were observed; and the wound healing at the donor site was observed. During follow-up, the texture of the flap and complications at the donor site were observed. At the last follow-up, the effect of flap repair was evaluated by using the modified self-made comprehensive efficacy rating table.Results:After operation, all the flaps of patients survived without vascular crisis; the wounds in the donor site healed smoothly. During follow-up of 6 to 26 months, the flaps had good texture; only linear scars remained in the donor area without scar contracture, pain or other discomfort. At the last follow-up, the total score of flap repair effect of 12 patients was 75-95, with an average of 87, of which 5 cases were rated as excellent, 6 cases as good, and 1 case as fair, and the proportion of excellent and good patients was 11/12.Conclusions:The application of anterolateral thigh flap with blood supply from the medial femoral perforator to repair wounds on extremities is an alternative method for the vascular variations such as no descending branch, oblique branch, or small perforator of the lateral circumflex femoral artery during the resection of the anterolateral thigh flap. This operation has the advantages of simple operation, small trauma, and others, which effectively ensures the smooth operation.
9.Application of "ABC" three line perforator locating method for free anterolateral perforator flap of calf
Tao ZHANG ; Lin YANG ; Junnan CHENG ; Shengzhe LIU ; Zhijin LIU ; Yongtao HUANG ; Qinfeng GAO ; Fengwen SUN ; Chengpeng YANG ; Jihui JU
Chinese Journal of Microsurgery 2023;46(1):70-75
Objective:To explore the feasibility of an "ABC" three line perforator locating method in design and harvest of free anterolateral perforator flap of calf.Methods:Between March 2021 and November 2021, 42 patients with 62 wounds on hand and foot were treated in the Department of Hand Surgery, Suzhou Ruihua Orthopaedic Hospital. The "ABC" three line perforator locating method was applied to determine the location and source of perforating branch before operation and to guide the design and harvest of flap during operation in wound reconstruction. Among the 42 patients, 24 had the injury of single digit, 7 had the injuries with 2 digits, 4 with 3 digits, 1 with 4 digits, 1 of the first web, 1 in the wrist, 2 of the great toe, 1 of second toe and 1 in dorsal foot. The sizes of soft tissue defect were 1.5 cm×2.0 cm-3.0 cm×14.0 cm. The sizes of the flaps were 2.0 cm×2.5 cm-3.5 cm×15.0 cm. All donor sites were sutured directly. In the follow-up, sensations of flaps were evaluated following the sensory function evaluation standard of British Medical Research Council(BMRC), and the recovery of the donor and recipient sites was evaluated by the flap comprehensive evaluation scale. Regular follow-up were scheduled at outpatient clinic.Results:A total of 162 perforators were located before operation. There were 95 perforating branches being explored in the operation, of which 5 patients had 1 extra perforating branch than that located before surgery. Seventy-six perforating branches were found consistent with preoperative localisation, with a coincidence rate of 84.4%(76/90). Sixty-four perforating branches were found consistent with the preoperative source with an accuracy rate of 84.2%(64/76). All the 62 flaps survived without a vascular compromise. Follow-up lasted for 6-10(mean 7.1) months. The colour and texture of the flaps were excellent. The flaps were thin and wear-resistant. The sensory function of the flaps was evaluated at S 1-S 3 by BMRC. Comprehensive evaluation scale of flap was excellent in 38 patients and good in 4 patients. Conclusion:"ABC" three line perforator locating method in design of free anterolateral calf flap is a feasible and an ideal auxiliary method in surgical practice. It combines anatomical knowledge, clinical experience and Doppler ultrasound localisation as well as accurately guides the location and source prediction of perforator before surgery.
10.Distribution characteristics and clinical application of perforators of anterolateral thigh flap pedicled with oblique branch of lateral circumflex femoral artery
Lin YANG ; Yang CAO ; Junnan CHENG ; Yongtao HUANG ; Zhijin LIU ; Qinfeng GAO ; Chengpeng YANG ; Fengwen SUN ; Yucheng LIU ; Jihui JU
Chinese Journal of Plastic Surgery 2023;39(5):463-471
Objective:To explore the distribution characteristics of the perforators of the oblique branch of the lateral circumflex femoral artery, and to report the clinical effect of the anterolateral thigh flap pedicled with the oblique branch in repairing the wounds of the extremities.Methods:The clinical data of the patients with anterolateral thigh flap pedicled with oblique branch of lateral circumflex femoral artery in Suzhou Ruihua Orthopaedic Hospital from December 2020 to April 2021 were analyzed retrospectively. High frequency color Doppler ultrasound was used to detect the large perforators of the oblique branch of the lateral circumflex femoral artery near the midpoint of the line between the anterior superior iliac spine and the lateral margin of the patella. With reference to the location of the perforators, according to the size and shape of the defect in the recipient area, the anterolateral thigh flap pedicled with oblique branch was designed and dissected to repair the wound. During the operation, the distance between the emitting point of the main oblique branch, the skin entry point of the perforators and the anterior superior iliac spine was measured with a steel ruler, the diameter of the perforators was measured with a microscale, and the number of perforators was counted. The survival and complications of the flap were observed and followed up after operation. In the last follow-up, the comprehensive evaluation scale was used to evaluate the repair effect: 90 to 100 points is excellent, 75 to 89 points is good, 60 to 74 points is average, and less than 60 points is poor.Results:A total of 84 patients were included, including 62 males and 22 females, aged from 14 to 82 years (mean 46.9 years), including 32 cases of hand wounds, 6 cases of forearm wounds, 3 cases of upper arm wounds, 10 cases of calves and 33 cases of foot and ankle wounds. The wound area was 6 cm × 4 cm-20 cm × 45 cm. A total of 88 flaps were removed in 84 patients (skin flaps on both thighs were removed in 4 patients). The size of the skin flap of 88 thighs was 7 cm × 5 cm-37 cm × 11 cm, of which 85 sides of 82 cases survived completely. One case of diabetes had complete necrosis 1 month after operation, and 1 case of 34 cm had necrosis of the distal end of 3 cm × 3 cm skin flap. Necrotic skin flaps were repaired with skin grafting. Four patients developed arterial crisis within 24 hours after operation, and those flaps survived after surgical exploration. All donor areas healed. During the follow-up of 6 to 9 months, the shape of the recipient area was normal in all patients, and there was no deep tissue infection such as osteomyelitis. The color and texture of all flaps were good. The sensation returned to S1-S2 after operation. The skin flap comprehensive evaluation scale was used to evaluate the repair effect. The patients’ score ranged from 73 to 94 points, with an average of 88.1 points. Including 33 excellent cases, 46 good cases and 5 average cases, the excellent and good rate was 94.0%(79/84). A total of 215 perforators were marked with 88 flaps before operation, and 208 perforators were found during the operation(the diameter of the perforators was 0.4-1.5 mm), of which 130 were sent out by oblique branches. There were perforators of the oblique branch in all flaps, with an average of 1.5 on each side, including 84(64.6%) septocutaneous perforators and 46(35.4%) musculocutaneous perforators. Most of the oblique branches originate from the lateral circumflex femoral artery, which runs in the intermuscular septum between the rectus femoris and the intermediate femoris muscle. It is divided into deep branches and superficial branches at the middle and upper 1/3 junction of the line between the anterior superior iliac spine and the lateral margin of the patella. The skin perforators of the oblique branch of the lateral circumflex femoral artery is mostly sent out from the superficial branch, and there are 118 perforators located at the midpoint and proximal end of the line between the anterior superior iliac spine and the lateral margin of the patella, accounting for 90.8% (118/130), reaching a peak at 0.4 (there are 37 perforators).Conclusion:The oblique branch of the lateral circumflex femoral artery is relatively constant, and most of the perforators are located near the midpoint of the line between the anterior superior iliac spine and the lateral margin of the patella, and the proportion of septocutaneous perforator is high. The distribution of perforator is regular, the blood supply is reliable, the application mode is flexible, and the donor site position is more concealed while the blood supply of the flap is secured.

Result Analysis
Print
Save
E-mail