1.Analysis of red blood cell RhAG protein, Rh D, and Rh CE antigens expression in carriers of RHAG 808A: a common variant in the Chinese population
Yalin LUO ; Mingming SUN ; Jizhi WEN ; Zhijian LIAO ; Yanli JI
Chinese Journal of Blood Transfusion 2025;38(5):660-664
Objective: To investigate the impact of RHAG
808A variant, commonly identified in the Chinese population, on RhAG protein, RhD and RhCE antigens expression through in vivo and in vitro expression analysis. Methods: A missense mutation of RHAG gene (c. 808G>A, p. Val270Ile) with high frequency was found in KMxD database. Bioinformatics analysis was performed using Polyphen-2 and Provean software. High resolution melting (HRM) method was utilized to screen for the variant carriers in the blood donors. The expression of RhAG protein, RhD and RhCE antigens on the surface of red cells of variant carriers were detected via flow cytometry. Wild-type and mutant vectors of RHAG were constructed and transfected into HEK 293T cells for in vitro expression analysis. Then, the expression of RhAG protein, RhD and RhCE antigens were analyzed by flow cytometry. Results: Polyphen-2 and Provean software suggested that the amino acid change (p. Val270Ile) of RhAG protein may be harmful or neutral respectively. Among the 999 blood donors from Guangzhou Blood Center, 4 homozygous carriers and 99 heterozygous carriers of RHAG
808A mutant allele were identified. The frequency of this allele was 5.4% (107/1 998). No significant differences in RhAG protein, RhD and RhCE antigens expression level was identified between the homozygous carriers, heterozygous carriers of RHAG
808A variant allele and the wild-type individuals. In vitro analysis for antigen expression study obtained the similar results. Conclusion: The RHAG
808A variant allele commonly identified in the Chinese population has no effect on the expression of RhAG protein, RhD and RhCE antigens, so the variant should be a population polymorphism site.
2.Food-derived bioactive peptides: health benefits, structure‒activity relationships, and translational prospects.
Hongda CHEN ; Jiabei SUN ; Haolie FANG ; Yuanyuan LIN ; Han WU ; Dongqiang LIN ; Zhijian YANG ; Quan ZHOU ; Bingxiang ZHAO ; Tianhua ZHOU ; Jianping WU ; Shanshan LI ; Xiangrui LIU
Journal of Zhejiang University. Science. B 2025;26(11):1037-1058
Food-derived bioactive peptides (FBPs), particularly those with ten or fewer amino acid residues and a molecular weight below 1300 Da, have gained increasing attention for their safe, diverse structures and specific biological activities. The development of FBP-based functional foods and potential medications depends on understanding their structure‒activity relationships (SARs), stability, and bioavailability properties. In this review, we provide an in-depth overview of the roles of FBPs in treating various diseases, including Alzheimer's disease, hypertension, type 2 diabetes mellitus, liver diseases, and inflammatory bowel diseases, based on the literature from July 2017 to Mar. 2023. Subsequently, attention is directed toward elucidating the associations between the bioactivities and structural characteristics (e.g., molecular weight and the presence of specific amino acids within sequences and compositions) of FBPs. We also discuss in silico approaches for FBP screening and their limitations. Finally, we summarize recent advancements in formulation techniques to improve the bioavailability of FBPs in the food industry, thereby contributing to healthcare applications.
Humans
;
Peptides/therapeutic use*
;
Structure-Activity Relationship
;
Functional Food
;
Diabetes Mellitus, Type 2/drug therapy*
;
Biological Availability
;
Alzheimer Disease/drug therapy*
;
Inflammatory Bowel Diseases/drug therapy*
;
Hypertension/drug therapy*
;
Liver Diseases/drug therapy*
;
Bioactive Peptides, Dietary
3.A self-controlled study on endotracheal tube cuff pressure management modes.
Yanxin LIU ; Yanhong GAO ; Xingli ZHAO ; Hongxia LI ; Baojun SUN ; Xiangqun FANG ; Zhijian ZHANG
Chinese Critical Care Medicine 2025;37(4):348-353
OBJECTIVE:
To explore the effects of different endotracheal tube cuff pressure management modes on cuff sealing and the pressure exerted on the tracheal wall.
METHODS:
A prospective self-controlled study was conducted. Eleven patients undergoing endotracheal intubation and mechanical ventilation with an automatic airway management system (AGs) admitted to the Second Medical Centre of the Chinese People's Liberation Army General Hospital from October 1, 2020, to April 1, 2022, were enrolled as the study subjects. Within 24 hours after the establishment of artificial airway and mechanical ventilation, four cuff pressure management modes were randomly applied to each patient for 24 hours in sequence: automatic cuff pressure management mode [modeI: the safe range of cuff pressure was set at 20-35 cmH2O (1 cmH2O≈0.098 kPa), and the CO2 pressure above the endotracheal tube cuff was automatically detected by AGs every 5 minutes to determine the cuff sealing status, and the cuff pressure was automatically adjusted], constant cuff pressure (25 cmH2O) management mode (mode II: the cuff pressure was monitored by AGs through a pressure sensor, and the cuff pressure was maintained at 25 cmH2O via a pressure pump), constant cuff pressure (30 cmH2O) management mode (mode III: the cuff pressure was monitored by AGs through a pressure sensor, and the cuff pressure was maintained at 30 cmH2O via a pressure pump), and manual cuff pressure management mode (mode IV: the cuff pressure was manually measured by nurses every 6-8 hours using a cuff pressure gauge to keep the cuff pressure at 25-30 cmH2O after inflation). The CO2 pressure above the endotracheal tube cuff (at 60-minute intervals) and the cuff pressure changes (at 50-ms intervals) were recorded to compare the differences in number of cuff leaks [no leak was defined as CO2 pressure = 0, small leak as 0 < CO2 pressure < 2 mmHg (1 mmHg≈0.133 kPa), and large leak as CO2 pressure ≥ 2 mmHg] and cuff pressure among modesI-IV.
RESULTS:
A total of 24 CO2 pressure measurements were taken per patient across the four modes, resulting in a total of 264 detections for each mode. Regarding the cuff leak, the total number of leak and large leak in modeIwas significantly lower than that in modes II-IV [total leak: 30 cases (11.36%) vs. 81 cases (30.68%), 70 cases (26.52%), 103 cases (39.02%); large leak: 15 cases (5.68%) vs. 50 cases (18.94%), 48 cases (18.18%), 66 cases (25.00%), all P < 0.05]. There was no significant difference in the number of cuff leak between modes II and III, and mode IV had the most severe cuff leak. In terms of cuff pressure, since mode IV required blocking the cuff tube from the AGs tube and the AGs cuff pressure management module did not actually work, real-time monitoring of cuff pressure was not possible. Therefore, cuff pressure changes were only analyzed in modes I-III. Each of the 11 patients underwent 24-hour cuff pressure monitoring under modes I-III, with 19 008 000 monitoring times for each mode. The cuff pressure in mode I was between that in modes II and III [cmH2O: 27.09 (26.10, 28.14) vs. 26.60 (25.92, 27.47), 31.01 (30.33, 31.88), both P < 0.01]. Moreover, the number of extreme values of cuff pressure > 50 cmH2O in mode I was significantly lower than that in modes II and III [19 900 cases (0.105%) vs. 22 297 cases (0.117%), 27 618 cases (0.145%), both P < 0.05].
CONCLUSION
Dynamically monitoring the CO2 pressure above the cuff to guide the adjustment of endotracheal tube cuff pressure can achieve better cuff sealing with a relatively lower cuff pressure load.
Humans
;
Intubation, Intratracheal/instrumentation*
;
Pressure
;
Prospective Studies
;
Respiration, Artificial
;
Male
;
Airway Management/methods*
;
Female
;
Middle Aged
4.Multidisciplinary expert consensus on weight management for overweight and obese children and adolescents based on healthy lifestyle
HONG Ping, MA Yuguo, TAO Fangbiao, XU Yajun, ZHANG Qian, HU Liang, WEI Gaoxia, YANG Yuexin, QIAN Junwei, HOU Xiao, ZHANG Yimin, SUN Tingting, XI Bo, DONG Xiaosheng, MA Jun, SONG Yi, WANG Haijun, HE Gang, CHEN Runsen, LIU Jingmin, HUANG Zhijian, HU Guopeng, QIAN Jinghua, BAO Ke, LI Xuemei, ZHU Dan, FENG Junpeng, SHA Mo, Chinese Association for Student Nutrition & ; Health Promotion, Key Laboratory of Sports and Physical Fitness of the Ministry of Education,〖JZ〗 Engineering Research Center of Ministry of Education for Key Core Technical Integration System and Equipment,〖JZ〗 Key Laboratory of Exercise Rehabilitation Science of the Ministry of Education
Chinese Journal of School Health 2025;46(12):1673-1680
Abstract
In recent years, the prevalence of overweight and obesity among children and adolescents has risen rapidly, posing a serious threat to their physical and mental health. To provide scientific, systematic, and standardized weight management guidance for overweight and obese children and adolescents, the study focuses on the core concept of healthy lifestyle intervention, integrates multidisciplinary expert opinions and research findings,and proposes a comprehensive multidisciplinary intervention framework covering scientific exercise intervention, precise nutrition and diet, optimized sleep management, and standardized psychological support. It calls for the establishment of a multi agent collaborative management mechanism led by the government, implemented by families, fostered by schools, initiated by individuals, optimized by communities, reinforced by healthcare, and coordinated by multiple stakeholders. Emphasizing a child and adolescent centered approach, the consensus advocates for comprehensive, multi level, and personalized guidance strategies to promote the internalization and maintenance of a healthy lifestyle. It serves as a reference and provides recommendations for the effective prevention and control of overweight and obesity, and enhancing the health level of children and adolescents.
5.Application of automatic slide-dropping instrument in bone marrow chromosomal karyotyping
Wei ZHANG ; Chenghua CUI ; Ji ZHOU ; Yanyi LYU ; Siping WANG ; Shenghua CHEN ; Huijun WANG ; Qi SUN ; Zhijian XIAO ; Chengwen LI
Chinese Journal of Medical Genetics 2024;41(7):803-806
Objective:To explore the application of an automatic slide-dropping instrument in bone marrow chromosomal karyotyping.Methods:The effects of manual and automatic dropping methods under different environmental humidity were retrospectively analyzed, and the repeatability of the automatic dropping method was analyzed.Results:No statistical difference was found between the results of automatic and manual dropping methods under the optimum ambient humidity and high humidity ( P>0.05). At low humidity, there was a statistical difference between the two methods ( P<0.05). With regard to the repeatability, the coefficient of variations of the automatic dropping method for the number of split phases, the rate of good dispersion and the rate of overlap were all lower than those of the manual dropping method. A statistical difference was also found in the number of split phases ( P<0.05) but not in the discrete excellent rate and overlapping rate between the two methods ( P>0.05). Conclusion:Better effect can be obtained by the automatic dropping instrument. It is suggested to gradually replace manual work with machine.
6.Detection and recognition of urinary VOCs marker gases for bladder cancer based on electronic nose technology
Zhijian HUANG ; Yutong HAN ; Yufan SUN ; Zhigang ZHU
International Journal of Biomedical Engineering 2024;47(2):115-122
Objective:To design an electronic nose that can detect and identify urinary volatile organic compounds (VOCs) as marker gases for bladder cancer.Methods:Isopropyl alcohol, ethylbenzene, acetic acid, and ammonia were selected as target gases, and 8 metal oxide gas sensors were used to construct sensor arrays for testing and collecting experimental data, and different characteristics were normalized. Recursive feature elimination (RFE) was used to select the best feature subset, and principal component analysis (PCA) and linear discriminant analysis (LDA) were further introduced to reduce the data dimension and facilitate visual analysis. In addition, three machine learning algorithms, including support vector machine (SVM), random forest (RF), and K-nearest neighbor (KNN), were combined to train and verify the model.Results:When the feature number was 12, the accuracy of the model classification had the best performance. The feature subset consisted of 5 differences, 5 sensitivities, and 2 integrals, and the data was reduced to 12 dimensions. Only PCA couldn’t distinguish the four gases. The LDA classification performance was significantly better than that of PCA, except that isopropyl alcohol and acetic acid had a small overlap area. LDA could distinguish ethylbenzene and ammonia from isopropyl alcohol and acetic acid; the sample points were gathered, which means the clustering performance was also better. The prediction accuracy of SVM, RF, and KNN was 0.85, 0.56, and 0.79, respectively. After model verification, the classification accuracy of PCA+SVM, LDA+RF, and LDA+KNN was 0.97, 0.94, and 0.97, respectively.Conclusions:An electronic nose was designed to detect and identify urinary VOCs marker gases for bladder cancer.
7.Research progress on automated insulin delivery system in the field of diabetes management.
Zhichao YU ; Yufan SUN ; Zhijian HUANG ; Zhanhong LI ; Jianjun LONG ; Zhigang ZHU
Journal of Biomedical Engineering 2024;41(6):1279-1285
Diabetes and its complications pose a serious threat to human life and health. It has become a public health problem of wide concern worldwide. Currently, diabetes is mainly treated with insulin injection in clinic. However, manual insulin injection still has many shortcomings. In recent years, with the deepening of research, it has been found that an automated insulin delivery system (AID), which combines a continuous glucose monitoring device with an insulin pump, can significantly improve the effectiveness of diabetes treatment and reduce the incidence of complications in patients. This paper firstly introduces the composition of the AID system and its working principle, and then details the development history and current status of the related technologies from the aspects of continuous glucose monitoring technology, insulin pumps and the development of closed-loop control algorithms, etc. Finally, this paper looks forward to the application prospect and future development of AID system in the field of diabetes treatment, providing theoretical reference for further research.
Humans
;
Insulin Infusion Systems
;
Insulin/administration & dosage*
;
Blood Glucose Self-Monitoring/instrumentation*
;
Diabetes Mellitus/drug therapy*
;
Algorithms
;
Hypoglycemic Agents/administration & dosage*
;
Blood Glucose/analysis*
;
Pancreas, Artificial
;
Automation
8.CRL3 E3 ligase regulates glutamine and cystine metabolisms.
Qiyin ZHOU ; Zhijian LI ; Yi SUN
Protein & Cell 2024;15(12):867-871
9.Use of the ETV6/RUNX1 probe to verify the performance of the fluorescence in situ hybridization probe before clinical detection
Jing XIAO ; Yingchun ZHENG ; Jiawei ZHAO ; Chenghua CUI ; Huijun WANG ; Qi SUN ; Jiao MA ; Yueshen MA ; Zhen SONG ; Zhijian XIAO ; Chengwen LI
Chinese Journal of Hematology 2024;45(1):48-53
Objective:To explore the standardized performance of a FISH probe before clinical detection.Methods:The probe sensitivity and specificity of ETV6/RUNX1 were analyzed via interphase and metaphase FISH in 20 discarded healthy bone marrow samples. The threshold system of the probe was established using an inverse beta distribution, and an interpretation standard was established. Finally, a parallel-controlled polymerase chain reaction detection study was conducted on 286 bone marrow samples from patients at our hospital. The clinical sensitivity, specificity, and diagnostic coincidence rate of ETV6/RUNX1 FISH detection were analyzed, and the diagnostic consistency of the two methods was analyzed by the kappa test.Results:The probe sensitivity and specificity of the ETV6/RUNX1 probe were 98.47% and 100%, respectively. When 50, 100, and 200 cells were counted, the typical positive signal pattern cutoffs were 5.81%, 2.95%, and 1.49%, respectively, and the atypical positive signal pattern cutoffs were 13.98%, 9.75%, and 6.26%, respectively. The clinical sensitivity of FISH was 96.1%, clinical specificity was 99.6%, diagnostic coincidence rate was 99.00%, diagnostic consistency test kappa value was 0.964, and P value was <0.001.Conclusion:For FISH probes without a national medical device registration certificate, standardized performance verification and methodology performance verification can be performed using laboratory developed test verification standards to ensure a reliable and accurate reference basis for clinical diagnosis and treatment.
10.Clinical characteristics and prognosis of patients with myelodysplastic syndrome with a bone marrow nucleated erythroid cell proportion of greater than or equal to 50%
Yanping ZENG ; Bing LI ; Tiejun QIN ; Zefeng XU ; Shiqian QU ; Lijuan PAN ; Qingyan GAO ; Meng JIAO ; Junying WU ; Huijun WANG ; Chengwen LI ; Yujiao JA ; Qi SUN ; Zhijian XIAO
Chinese Journal of Hematology 2024;45(7):651-659
Objective:To analyze the clinical characteristics and prognosis of patients with myelodysplastic syndrome (MDS) with a bone marrow nucleated erythroid cell proportion of greater than or equal to 50% (MDS-E) .Methods:The clinical characteristics and prognostic factors of patients with MDS-E were retrospectively analyzed by collecting the case data of 1 436 newly treated patients with MDS diagnosed in the Institute of Hematology and Blood Diseases Hospital, Chinese Academy of Medical Sciences from May 2014 to June 2023.Results:A total of 1 436 newly diagnosed patients with complete data were included in the study, of which 337 (23.5%) patients with MDS-E had a younger age of onset and lower neutrophil and platelet counts compared with those in patients with an erythroid cell proportion of less than 50% (MDS-NE) (all P<0.05). The proportion of MDS cases with ring sideroblasts (MDS-RS) was higher in the MDS-E group than in the MDS-NE group, and multi-hit TP53 mutations were more enriched in the MDS-E group than in the MDS-NE group (all P<0.05). Among patients with MDS-RS, the frequency of complex karyotypes and the TP53 mutation rate were significantly lower in the MDS-E group than in the MDS-NE group (0 vs 11.9%, P=0.048 and 2.4% vs 15.1%, P=0.053, respectively). Among patients with TP53 mutations, the frequencies of complex karyotypes and multi-hit TP53 mutations were significantly higher in the MDS-E group than in the MDS-NE group (87.5% vs 64.6%, P=0.003 and 84.0% vs 54.2%, P<0.001, respectively). Survival analysis of patients with MDS-RS found that the overall survival (OS) in the MDS-E group was better than that in the MDS-NE group [not reached vs 63 (95% CI 53.3-72.7) months, P=0.029]. Among patients with TP53 mutations and excess blasts, the OS in the MDS-E group was worse than that in the MDS-NE group [6 (95% CI 2.2-9.8) months vs 12 (95% CI 8.9-15.1) months, P=0.022]. Multivariate analysis showed that age of ≥65 years ( HR=2.47, 95% CI 1.43-4.26, P=0.001), mean corpuscular volume (MCV) of ≤100 fl ( HR=2.62, 95% CI 1.54-4.47, P<0.001), and TP53 mutation ( HR=2.31, 95% CI 1.29-4.12, P=0.005) were poor prognostic factors independent of the Revised International Prognostic Scoring System (IPSS-R) prognosis stratification in patients with MDS-E. Conclusion:Among patients with MDS-RS, MDS-E was strongly associated with a lower proportion of complex karyotypes and TP53 mutations, and the OS in the MDS-E group was longer than that in the MDS-NE group. Among patients with TP53 mutations, MDS-E was strongly associated with complex karyotypes and multi-hit TP53 mutations, and among TP53-mutated patients with excess blasts, the OS in the MDS-E group was shorter than that in the MDS-NE group. Age of ≥65 years, MCV of ≤100 fl, and TP53 mutation were independent adverse prognostic factors affecting OS in patients with MDS-E.


Result Analysis
Print
Save
E-mail