1.Application of 3D-printing patient-specific instruments combined with customized locking plate in opening wedge high tibial osteotomy
Chi MA ; Ning WANG ; Yong CHEN ; Zhihan WEI ; Fengji LIU ; Chengzhe PIAO
Chinese Journal of Tissue Engineering Research 2025;29(9):1863-1869
BACKGROUND:The use of 3D-printed patient-specific instruments in opening wedge high tibial osteotomy has advantages such as shorter operative time,fewer fluoroscopic exposures,and higher correction accuracy.However,previous studies have reported issues such as significant damage to surrounding soft tissues and improper fixation of the plates. OBJECTIVE:To investigate the clinical efficacy of using 3D-printed patient-specific instruments combined with customized locking plate in opening wedge high tibial osteotomy for the treatment of knee osteoarthritis. METHODS:A total of 20 patients diagnosed with knee osteoarthritis were divided into the 3D group(n=10)and the conventional group(n=10)according to surgical methods.The 3D group underwent opening wedge high tibial osteotomy using 3D-printed patient-specific instruments combined with customized locking plate,while the conventional group underwent opening wedge high tibial osteotomy using conventional methods.The operative time,fluoroscopic exposures,incision length,pre-and postoperative hip-knee-ankle angle,medial proximal tibial angle,posterior tibial slope,the difference between the planned and actual correction angle,preoperative and 1,3,6 months postoperative knee range of motion and Lysholm score,and incidence of complications were analyzed and compared between the two groups. RESULTS AND CONCLUSION:(1)The operative time and fluoroscopic exposures were significantly shorter in the 3D group compared to the conventional group,with a statistically significant difference(P<0.001).(2)Both groups showed a significant improvement in postoperative hip-knee-ankle angle and medial proximal tibial angle compared to preoperative values,with a statistically significant difference(P<0.001),while there was no significant change in posterior tibial slope.In the 3D group,the postoperative hip-knee-ankle angle,medial proximal tibial angle,and posterior tibial slope differed from their respective preoperative planned values by(-0.22±0.72)°,(-0.20±0.73)°,and(0.23±0.37)°,but the differences were not statistically significant.The difference between the planned and actual correction angle of 3D group was significantly smaller than that of conventional group(P<0.05).(3)Both groups showed a gradual increase in knee range of motion and Lysholm scores after surgery(P<0.001).Compared to the conventional group,the 3D group had superior knee range of motion at 1 and 3 months postoperatively,as well as a higher Lysholm score at 1 month postoperatively,with statistically significant differences(P<0.05).There were no statistically significant differences in Lysholm score at 3 months and knee range of motion and Lysholm score at 6 months between the two groups(P>0.05).(4)Complications occurred in neither groups.(5)The above results indicate that both 3D-printed patient-specific instruments combined with customized locking plate and conventional methods have good clinical efficacy.However,the former has a shorter operative time,fewer fluoroscopic exposures,and faster postoperative recovery of knee joint function.Additionally,3D-printed patient-specific instruments can achieve preoperative planning accurately.
2.Phase Change and Quantity-quality Transfer Analysis of Medicinal Materials, Decoction Pieces and Standard Decoction of Haliotidis Concha (Haliotis discus hannai)
Zhihan YANG ; Jingwei ZHOU ; Weichao WANG ; Yu HUANG ; Chuang LUO ; Lian YANG ; Chenyu ZHONG ; Hongping CHEN ; Fu WANG ; Yuan HU ; Youping LIU ; Shilin CHEN ; Lin CHEN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):206-214
ObjectiveTo explore the quantity-quality transfer process of medicinal materials, decoction pieces and standard decoction of Haliotidis Concha(Haliotis discus hannai) by analyzing the physical phase and compositional changes, so as to provide references for the effective control of its quality. MethodsA total of 20 batches of Haliotidis Concha(H. discus hannai) from different habitats were collected and prepared into corresponding calcined products and standard decoction, and the content of CaCO3 of the three samples were determined and the extract yield and transfer rate of CaCO3 were calculated. The changes in elemental composition and their relative contents were investigated by X-ray fluorescence spectrometry(XRF), X-ray diffraction(XRD) was used to study the changes in the phase compositions of the three samples and to establish their respective XRD specific chromatogram. Fourier transform infrared spectrometry(FTIR) was used to study the changes in the chemical composition and content changes of the three samples and to establish their respective FTIR specific chromatogram, while combining hierarchical cluster analysis(HCA), principal component analysis(PCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA) to find the common and differential characteristics, in order to explore the quantity-quality transfer relationship in the preparation process of standard decoction of Haliotidis Concha(H. discus hannai). ResultsThe CaCO3 contents of the 20 batches of medicinal materials, decoction pieces and standard decoction of Haliotidis Concha(H. discus hannai) were 93.87%-98.95%, 96.02%-99.97% and 38.29%-51.96%, respectively, and the extract yield of standard decoction was 1.71%-2.37%, and the CaCO3 transfer rate of decoction pieces-standard decoction was 0.68%-1.27%. XRF results showed that the elemental species and their relative contents contained in Haliotidis Concha and its calcined products had a high degree of similarity, and although there was no obvious difference in the elemental species contained in decoction pieces and standard decoction, the difference in the relative contents was obvious, which was mainly reflected in the decrease of the relative content of element Ca and the increase of the relative content of element Na. XRD results showed that Haliotidis Concha mainly contained CaCO3 of aragonite and calcite, while calcined Haliotidis Concha only contained CaCO3 of calcite, and standard decoction mainly contained CaCO3 of calcite and Na2CO3 of natrite. FTIR results showed that there were internal vibrations of O-H, C-H, C=O, HCO3- and CO32- groups in Haliotidis Concha, while O-H, HCO3- and CO32- groups existed in the calcined products and standard decoction. ConclusionThe changes of Haliotidis Concha and calcined Haliotidis Concha are mainly the increase of CaCO3 content, the transformation of CaCO3 aragonite crystal form to calcite crystal form and the absence of organic components after calcination, and the changes of calcined products and standard decoction are mainly the decrease of CaCO3 content and the increase of Na2CO3 relative content. The method established in the study is applicable to the quality control of the shellfish medicines-decoction pieces- standard decoction, which provides a new idea for the study of quality control of dispensing granules of shellfish medicines.
3.Phase Change and Quantity-quality Transfer Analysis of Medicinal Materials, Decoction Pieces and Standard Decoction of Haliotidis Concha (Haliotis discus hannai)
Zhihan YANG ; Jingwei ZHOU ; Weichao WANG ; Yu HUANG ; Chuang LUO ; Lian YANG ; Chenyu ZHONG ; Hongping CHEN ; Fu WANG ; Yuan HU ; Youping LIU ; Shilin CHEN ; Lin CHEN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):206-214
ObjectiveTo explore the quantity-quality transfer process of medicinal materials, decoction pieces and standard decoction of Haliotidis Concha(Haliotis discus hannai) by analyzing the physical phase and compositional changes, so as to provide references for the effective control of its quality. MethodsA total of 20 batches of Haliotidis Concha(H. discus hannai) from different habitats were collected and prepared into corresponding calcined products and standard decoction, and the content of CaCO3 of the three samples were determined and the extract yield and transfer rate of CaCO3 were calculated. The changes in elemental composition and their relative contents were investigated by X-ray fluorescence spectrometry(XRF), X-ray diffraction(XRD) was used to study the changes in the phase compositions of the three samples and to establish their respective XRD specific chromatogram. Fourier transform infrared spectrometry(FTIR) was used to study the changes in the chemical composition and content changes of the three samples and to establish their respective FTIR specific chromatogram, while combining hierarchical cluster analysis(HCA), principal component analysis(PCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA) to find the common and differential characteristics, in order to explore the quantity-quality transfer relationship in the preparation process of standard decoction of Haliotidis Concha(H. discus hannai). ResultsThe CaCO3 contents of the 20 batches of medicinal materials, decoction pieces and standard decoction of Haliotidis Concha(H. discus hannai) were 93.87%-98.95%, 96.02%-99.97% and 38.29%-51.96%, respectively, and the extract yield of standard decoction was 1.71%-2.37%, and the CaCO3 transfer rate of decoction pieces-standard decoction was 0.68%-1.27%. XRF results showed that the elemental species and their relative contents contained in Haliotidis Concha and its calcined products had a high degree of similarity, and although there was no obvious difference in the elemental species contained in decoction pieces and standard decoction, the difference in the relative contents was obvious, which was mainly reflected in the decrease of the relative content of element Ca and the increase of the relative content of element Na. XRD results showed that Haliotidis Concha mainly contained CaCO3 of aragonite and calcite, while calcined Haliotidis Concha only contained CaCO3 of calcite, and standard decoction mainly contained CaCO3 of calcite and Na2CO3 of natrite. FTIR results showed that there were internal vibrations of O-H, C-H, C=O, HCO3- and CO32- groups in Haliotidis Concha, while O-H, HCO3- and CO32- groups existed in the calcined products and standard decoction. ConclusionThe changes of Haliotidis Concha and calcined Haliotidis Concha are mainly the increase of CaCO3 content, the transformation of CaCO3 aragonite crystal form to calcite crystal form and the absence of organic components after calcination, and the changes of calcined products and standard decoction are mainly the decrease of CaCO3 content and the increase of Na2CO3 relative content. The method established in the study is applicable to the quality control of the shellfish medicines-decoction pieces- standard decoction, which provides a new idea for the study of quality control of dispensing granules of shellfish medicines.
4.Effect mechanism of electroacupuncture on diabetic peripheral neuropathy in rats based on gut microbiota and metabolomics.
Shanshan AI ; Dongrui GAO ; Ziting ZHAI ; Suyong WANG ; Yawen XUE ; Zhihan LIU ; Xiao YAN
Chinese Acupuncture & Moxibustion 2025;45(7):945-956
OBJECTIVE:
To explore the effect mechanism of electroacupuncture (EA) for ameliorating diabetic peripheral neuropathy (DPN) based on the analysis of gut microbiota and metabolomics.
METHODS:
Thirty SPF-grade male SD rats were randomly divided into a normal group, a model group, and an EA group, with 10 rats in each one. Except in the normal group, the intraperitoneally injection with streptozotocin was used to induce diabetes mellitus model in the rest groups. In the EA group, acupuncture was delivered at bilateral "Zusanli" (ST36), "Sanyinjiao" (SP6), "Pishu" (BL20) and "Shenshu" (BL23), and electric stimulation was attached to "Zusanli" (ST36)-"Sanyinjiao" (SP6) and "Pishu" (BL20)-"Shenshu" (BL23), on the same side, with continuous wave and a frequency of 2 Hz, for 10 min in each intervention. The intervention measure of each group was delivered once every 2 days, 3 times a week, for 8 consecutive weeks. Body weight, random blood glucose (RBG), thermal withdrawal latency (TWL), and mechanical withdrawal threshold (MWT) before intervention, and in 4 and 8 weeks of intervention, separately, as well as sensory nerve conduction velocity (SCV) and motor nerve conduction velocity (MCV) of the sciatic nerve after intervention were measured. Metagenomic sequencing (MS) was used to analyze gut microbiota and screen for differential species. Liquid chromatography-mass spectrometry (LC-MS) was employed to detect the differential metabolites in plasma, and the metabolic pathway enrichment analysis was performed on the differential metabolites. Spearman correlation analysis was adopted to assess the relationship between gut microbiota and metabolomics.
RESULTS:
After 4 and 8 weeks of intervention, when compared with the model group, the EA group showed the increase in body weight, TWL, MWT (P<0.01), and the decrease in RBG (P<0.01). Compared with the normal group, SCV and MCV, as well as Chao1 index were dropped in the model group (P<0.01), and those were elevated in the EA group when compared with those in the model group (P<0.01). The dominant bacterial phyla of each group were Firmicutes (F) and Bacteroidota (B), the ratio of them (F/B) in the model group was lower than that of the normal group (P<0.05), and F/B in the EA group was higher when compared with that in the model group (P<0.05). In comparison with the normal group, the relative abundance increased in Prevotella, Segatella, Prevotella-hominis and Segatella-copri (P<0.05); and it decreased in Ligilactobacillus, Eubacterium, Pseudoflavonifractor, Ligilactobacillus-murinus (P<0.05) in the model group. Compared with the model group, the relevant abundance of the above mentioned gut bacteria was all ameliorated in the EA group (P<0.05, P<0.01). Among the three groups, 120 differential metabolites were identified and enriched in 28 key metabolic pathways, such as glycerophospholipid and linoleic acid, of which, glycerophospholipid was the most significantly affected pathway in EA intervention. Spearman correlation analysis showed that 6 phosphatidylcholine metabolites were significantly positively correlated with Pseudoflavonifractor and were negatively with Prevotella, Segatella, Prevotella-hominis, Segatella-copri; 5 phosphatidylethanolamine metabolites were significantly negatively correlated with Pseudoflavonifractor and positively correlated with Prevotella, Segatella, Prevotella-hominis, Segatella-copri.
CONCLUSION
EA may regulate metabolic pathways such as glycerophospholipid, modulate specific gut microbiota such as Pseudoflavonifractor, Prevotella, and Segatella, and the co-expressed differential metabolites like phosphatidylcholine and phosphatidylethanolamine, thereby reducing blood glucose and protecting nerve function, so as to relieve the symptoms of DPN of rats.
Animals
;
Electroacupuncture
;
Male
;
Gastrointestinal Microbiome
;
Diabetic Neuropathies/microbiology*
;
Rats, Sprague-Dawley
;
Rats
;
Metabolomics
;
Humans
;
Acupuncture Points
5.LncRNA SNHG15 promotes proliferation, migration and invasion of lung adenocarcinoma cells by regulating COX6B1 through sponge adsorption of miR-30b-3p.
Xiuying GONG ; Shunfu HOU ; Miaomiao ZHAO ; Xiaona WANG ; Zhihan ZHANG ; Qinghua LIU ; Chonggao YIN ; Hongli LI
Journal of Southern Medical University 2025;45(7):1498-1505
OBJECTIVES:
To explore the molecular mechanism by which lncRNA SNHG15 regulates proliferation, invasion and migration of lung adenocarcinoma cells.
METHODS:
The lncRNA microarray chip dataset GSE196584 and LncBase were used to predict the lncRNAs that interact with miR-30b-3p, and their association with patient prognosis were investigated using online databases, after which lncRNA nucleolar RNA host gene 15 (SNHG15) was selected for further analysis. The subcellular localization of lncRNA SNHG15 and its expression levels in normal human lung epithelial cells and lung adenocarcinoma cell lines were detected using fluorescence in situ hybridization and qRT-PCR. In cultured A549 cells, the changes in cell proliferation, migration, and invasion following transfection with a SNHG15 knockdown plasmid (sh-SNHG15), a miR-30b-3p inhibitor, or their co-transfection were assessed with EdU, wound healing, and Transwell assays. Bioinformatics analyses were used to predict the regulatory relationship between lncRNA SNHG15 and COX6B1, and the results were verified using Western blotting and rescue experiments in A549 cells transfected with sh-SNHG15, a COX6B1-overexpressing plasmid, or both.
RESULTS:
LncRNA SNHG15 was shown to target miR-30b-3p, and the former was highly expressed in lung adenocarcinoma, and associated with a poor patient prognosis. LncRNA SNHG15 was localized in the cytoplasm and expressed at higher levels in A549 and NCI-H1299 cells than in BEAS-2B cells. In A549 cells, lncRNA SNHG15 knockdown significantly inhibited cell migration, invasion and proliferation, and these changes were reversed by miR-30b-3p inhibitor. A regulatory relationship was found between lncRNA SNHG15 and COX6B1, and their expression levels were positively correlated (r=0.128, P=0.003). MiR-30b-3p knockdown obviously decreased COX6B1 expression in A549 cells, and COX6B1 overexpression rescued the cells from the inhibitory effects of lncRNA-SNHG15 knockdown.
CONCLUSIONS
LncRNA SNHG15 may compete with COX6B1 to bind miR-30b-3p through a ceRNA mechanism to affect proliferation, migration, and invasion of lung adenocarcinoma cells.
Humans
;
MicroRNAs/metabolism*
;
RNA, Long Noncoding/genetics*
;
Cell Proliferation
;
Cell Movement
;
Lung Neoplasms/genetics*
;
Adenocarcinoma of Lung
;
Neoplasm Invasiveness
;
A549 Cells
;
Adenocarcinoma/genetics*
;
Gene Expression Regulation, Neoplastic
;
Cell Line, Tumor
6.Exploring the Application Patterns of Electroacupuncture Parameters in Hypertension Mechanism Research Based on Data Mining Technology
Zhihan LI ; Cunzhi LIU ; Binyan LI ; Fang WAN ; Lu WANG
Journal of Guangzhou University of Traditional Chinese Medicine 2025;42(11):2756-2760
Objective To investigate the characteristics and patterns of electroacupuncture parameters in hypertension mechanism research using data mining technology.Methods Computerized searches were conducted in multiple databases including China National Knowledge Infrastructure(CNKI),Wanfang Academic Journal Full-text Database,VIP Chinese Sci-Tech Journal Database,China Biology Medicine disc(CBM),PubMed,and Web of Science.The search period spanned from the inception of each database to July 2024.Basic research studies on electroacupuncture treatment for hypertension were collected to establish an electroacupuncture parameter database for hypertension.Descriptive statistics and association analysis were performed on the extracted data.Results The initial search yielded 13 977 publications.After screening,112 articles were ultimately included for analysis.The analysis revealed that the top three most frequently used acupoints were Zusanli(ST36),Quchi(LI11),and Taichong(LR3).The most commonly employed stimulation parameters were:continuous wave,2 Hz frequency,1 mA or 2 mA intensity,once daily treatment,30 minutes per session,with a total treatment duration of 28 days or 14 days.Conclusion In hypertension mechanism research,electroacupuncture stimulation parameters are predominantly characterized by low-frequency and low-intensity stimulation,with a treatment duration typically of 28 days.However,these parameter characteristics are primarily applied in mechanistic studies,and their translation to clinical practice requires further investigation.
7.Clinical features of and influencing factors of obsessive-compulsive personality disorder in patients with obsessive-compulsive disorder
Wenjing JIANG ; Xuhui WANG ; Zhihan XU ; Xuedi ZHANG ; Zhongqi WANG ; Ping ZHOU ; Na LIU
Sichuan Mental Health 2024;37(4):317-322
Background Obsessive-compulsive personality disorder and obsessive-compulsive disorder(OCD)are common psychological disorders with similar clinical symptoms,but the differences between the two need further clarification.Objective To explore the clinical features of and influencing factors of obsessive-compulsive personality disorder in patients with OCD,so as to provide references for further relevant clinical diagnosis and treatment.Methods A total of 195 patients with OCD were selected as the research subjects,who received treatment at the outpatient and inpatient departments of the Affiliated Brain Hospital of Nanjing Medical University from July 2022 to December 2023 and met the diagnostic criteria for OCD in the International Classification of Diseases,tenth edition(ICD-10).Evaluation was conducted by using the Yale-Brown Obsessive Compulsive Scale(Y-BOCS),Personality Diagnostic Questionnaire-4+(PDQ-4+),Obsessive-Compulsive Inventory-Revised(OCI-R),Beck Depression Inventory(BDI),Beck Anxiety Inventory(BAI)and Sheehan Disability Scale(SDS).In accordance with the score of Obsessive-Compulsive Personality Disorder Scale in PDQ-4+,patients were divided into the OCD group with obsessive-compulsive personality disorder(n=58)and the OCD group without obsessive-compulsive personality disorder(n=137).Pearson correlation analysis and Spearman correlation analysis were adopted to examine the correlation between clinical features and the score of the Obsessive-Compulsive Personality Disorder Scale.Multiple linear regression analysis was used to explore the influencing factors of OCD patients with obsessive-compulsive personality disorder.Results Statistically significant differences were observed between OCD patients with and without obsessive-compulsive personality disorder in the age,family history of mental illness,time without treatment,hoarding and ranking dimension scores in OCI-R,OCI-R total score,score of Obsessive-Compulsive Personality Disorder Scale in PDQ-4,and BDI score(P≤0.05).OCD patients with obsessive-compulsive personality disorder in the time without treatment,OCI-R total score,hoarding and ranking dimension scores in OCI-R and BDI score are all positively correlated with the score of the Obsessive-Compulsive Personality Disorder Scale(r=0.120,0.526,0.364,0.492,0.414,P<0.05).The results of multiple linear regression analysis showed that time without treatment(β=0.132,P<0.05),hoarding dimension score(β=0.283,P<0.05)and ranking dimension score in OCI-R(β=0.418,P<0.05)were the influencing factors of OCD patients with obsessive-compulsive personality disorder.Conclusion OCD patients with obsessive-compulsive personality disorder may have longer untreated periods,more pronounced functional impairments in hoarding and sorting and more severe depressive symptoms.Untreated time,hoarding symptoms and sorting symptoms may be influencing factors for OCD patients with obsessive-compulsive personality disorder.
8.Recognition of unilateral auditory neuropathy in children
Ying LI ; Zhihan LIN ; Xueyao WANG ; Yang YANG ; Xiao ZHANG ; Yi ZHOU ; Xin JIN ; Zhipeng ZHENG ; Jifeng SHI ; Xuetong WANG ; Jie BAI ; Lining GUO ; Haihong LIU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2024;59(5):447-454
Objective:This study aimed to compare the audiological characteristics between children with unilateral auditory neuropathy (UAN) and single-sided deafness (SSD) to establish a valid basis for the differential diagnosis of children with UAN.Methods:A retrospective analysis was conducted on audiological and imaging evaluations of children with UAN and SSD who were treated at Beijing Children′s Hospital of Capital Medical University between May 2015 and June 2023. There were 17 children with UAN, comprising 10 males and 7 females, with an average age of 4.7 years. Additionally, there were 43 children with SSD, consisting of 27 males and 16 females, with an average age of 6.5 years. Audiological assessments included Auditory brainstem response (ABR), Steady-state auditory evoked potential (ASSR), Behavioural audiometry, Cochlear microphonic potential (CM), Distortino-product otoacoustic emission (DPOAE), and acoustic immittance test. The results of the audiological assessment and imaging phenotypic between the two groups of children were compared and analyzed by applying SPSS 27.0 statistical software.Results:(1) The UAN group (77.8%) had a significantly higher rate of ABR wave III L than the SSD group (20.9%) ( P<0.01). The PA thresholds at 500 Hz and 1 000 Hz of children with SSD were higher than those of children with UAN, while the ASSR thresholds at 500 Hz, 1000 Hz, 2 000 Hz, and 4 000 Hz of children with SSD were significantly higher than those of children with UAN ( P<0.05). (2) The degree of hearing loss in both UAN and SSD children was predominantly complete hearing loss. The percentage of complete hearing loss was significantly higher (χ2=4.353, P=0.037) in the SSD group (93.0%, 40/43) than in the UAN group (63.6%, 7/11). However, the percentage of profound hearing loss was significantly higher in the UAN group (27.3%, 3/11) than in the SSD group (2.3%, 1/43) ( Fisher′s exact test, P=0.023). In terms of hearing curve configuration, the percentage of flat type was significantly higher in the SSD group (76.7%, 33/43) than in the UAN group (36.4%, 4/11). The proportion of the UAN group (27.3%, 3/11) was significantly higher than that in the SSD group (2.3%, 1/43) in ascending type ( P<0.05). There were no statistically significant differences in the hearing curves of the declining type and other types between the two groups ( P>0.05). (3) The proportion of imaging assessment without abnormality was significantly more common in the UAN group (81.8%) than in the SSD group (37.1%) (χ2=6.695, P=0.015). Conclusions:Compared to children with SSD, the occurrence of wave III L on the ABR test was significantly more common in children with UAN. The percentage of ascending hearing curves was significantly higher in children with UAN than in children with SSD. ASSR thresholds were significantly lower in children with UAN. The normal imaging phenotype was significantly more common in children with UAN than in children with SSD.
9.Current status and reflection on minimal access breast surgery
Chenlu LIU ; Yiwen LU ; Zhihan LIU ; Xinyu OU ; Shicheng SU
Chinese Journal of Surgery 2024;62(2):99-103
Minimal access breast surgery with the assistance of an endoscopy or robot has been an important advancement in surgical treatment in recent years. Compared to conventional open surgery, minimal access breast surgery only requires small incisions in concealed areas such as axillary fossa, avoiding visible scars on the surface of the breast, significantly improving the postoperative aesthetic appearance and patient satisfaction. With the rapid development of minimal access breast surgery, several institutions have established their own distinctive techniques. The concept of membrane anatomy in the breast, for example, has led to more natural-looking breast reconstruction following endoscopic procedures. The adoption of the reverse space dissection technique has greatly optimized the workflow of endoscopic breast cancer resection. Intraoperative navigation system for endoscopic breast-conserving surgery could allow precise localization of excision margins. Furthermore, the widespread use of the cold dissection technique for flap separation has reduced surgical duration and minimized flap damage. The emergence of unique techniques in the field of minimal access breast surgery promises to further advance and promote the adoption of minimal access breast surgery in China.
10.A retrospective cohort study of the postoperative prothesis-related complications of single-port endoscopic assisted versus open surgery on nipple sparing mastectomy and immediate prosthesis breast reconstruction
Jiangtao LI ; Zhihan LIU ; Chenlu LIU ; Xinyu OU ; Yiwen LU ; Shicheng SU
Chinese Journal of Surgery 2024;62(2):141-146
Objective:To examine the postoperative prosthesis-related complications, short-term surgical outcomes and patient satisfaction with breast reconstruction between patients who underwent endoscopic assisted versus conventional nipple sparing mastectomy and immediate prothesis breast reconstruction.Methods:This study was a retrospective cohort study. A retrospective analysis was performed on clinical data of 104 women with breast cancer who received nipple sparing mastectomy and immediate prothesis breast reconstruction from August 2021 to August 2022 at the Breast Tumor Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University. They were divided into two groups according to the surgical approach. A total of 53 patients, aged (43.3±9.9) years (range: 25 to 66 years), underwent endoscopic nipple sparing mastectomy (E-NSM group) and immediate prothesis breast reconstruction. The other 51 patients aged (39.9±7.8) years (range: 25 to 54 years) underwent conventional open surgery (C-NSM group). Short-term surgical outcomes including operation time, postoperative hospital stay, postoperative blood loss, and postoperative drainage volume in 2 days were recorded. Patient satisfaction with breast reconstruction was compared using the Wilcoxon rank sum test. Postoperative prothesis-related complications were investigated to determine the experience to deal with them.Results:No postoperative prosthesis-related infection, prosthesis loss, or necrosis of the nipple-areola complex occurred in the E-NSM group, while 1 patient suffered from hematoma, whose wound was skinned with resuture after disinfection. Five patients in the C-NSM group had prosthesis-related infection, 2 of them received prosthesis removal surgery combined with sufficient antimicrobial agent, another one underwent surgery for subcutaneous placement of the drain, as well as antimicrobial agent therapy, and the rest of them healed up only with antimicrobial agent therapy. All recovered well after treatment. One patient recovered from necrosis of the nipple-areola complex through periodic iodophor disinfection and dressing which ended in improvement of necrotic areas, another patient who had hematoma accepted the same treatment mentioned above and also healed. All the patients mentioned above are now in stable conditions. Patients in the E-NSM group had higher satisfaction with the cosmetic results of the breast prosthesis implant than those in the C-NSM group ( Z=-4.511, P<0.01). Conclusions:Both surgical approaches were proven to be safe and effective with a low rate of postoperative prosthesis-related complications. Patients in the E-NSM group were more satisfied with the cosmetic results of breast reconstruction than those in the C-NSM group.

Result Analysis
Print
Save
E-mail