1.Comparative efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation
Xinnan CHENG ; Shuai LI ; Jiaojiao BAI ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhen CHANG ; Zhigang ZHAO ; Yunfei HUANG ; Mingzhe FENG ; Liang YAN ; Hua HUI ; Lingbo KONG ; Baorong HE
Chinese Journal of Trauma 2025;41(2):148-156
Objective:To compare the clinical efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation.Methods:A retrospective cohort study was conducted to analyze the clinical data of 49 patients with fracture and dislocation of the lower cervical spine who were admitted to Honghui Hospital, Xi′an Jiaotong University School of Medicine from May 2021 to October 2022, including 38 males and 11 females, aged 29-61 years [(39.3±7.3)years]. Injury segments involved C 3 in 12 patients, C 4 in 11, C 5 in 8, C 6 in 9 and C 7 in 9. Twenty-one patients were treated with S8 navigation system (navigation group, 84 screws), and 28 with TINAVI orthopedic robot (robot group, 112 screws). The two groups were compared in terms of the total surgical duration, single screw placement time, total screw placement time, distance between the screw and the anterior cortex, incision length, intraoperative radiation dose, intraoperative blood loss and length of hospital stay. The height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and American Spinal Injury Association (ASIA) grade were assessed before surgery and at 3 days after surgery. Visual analogue scale (VAS), Japanese Orthopedic Association (JOA) score and neck dysfunction index (NDI) before surgery, at 3 days, 3 months after surgery and at the last follow-up were compared. The accuracy of screw placement, intraoperative invasion rate of adjacent facet joints and rate of postoperative complications (infection, screw loosening, etc.) were evaluated. Results:All the patients were followed up for 12-16 months [(13.6±1.9)months]. In the navigation group, the total surgical duration, distance from the screw to the anterior cortex and the intraoperative radiation dose were (236.2±30.6)minutes, (2.0±0.2)mm and (374.3±90.3)mGy respectively, which were significantly shorter or less than those in the robot group [(278.4±20.7)minutes, (10.6±2.9)mm and (448.4±77.9)mGy] ( P<0.01). The single screw placement time, total screw placement time, incision length and intraoperative blood loss were (3.5±0.4)minutes, (23.9±0.5)minutes, (9.1±2.4)cm and (422.2±30.4)ml respectively, which were significantly longer or more than those in the robot group [(2.6±0.2)minutes, (17.9±0.7)minutes, (6.6±2.6)cm and (360.3±56.3)ml] ( P<0.01). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). No significant differences were observed in the height of the intervertebral space, Cobb angle, sliding distance between the vertebral bodies and ASIA grade between the two groups ( P>0.05). At 3 days after surgery, the height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and ASIA grade in both groups were significantly improved when compared with those before surgery ( P<0.05 or 0.01). There were no significant differences in VAS, JOA scores or NDI between the two groups before surgery, at 3 days, 3 months after surgery and at the last follow-up ( P>0.05). The VAS, JOA scores and NDI in both groups were gradually improved at 3 days, 3 months and at the last follow-up after surgery when compared with those before surgery ( P<0.05). There was no significant difference in the accuracy of screw placement of levels 0 and 0+1 between the two groups ( P>0.05). No significant difference in the intraoperative invasion rate of adjacent facet joints between the two groups was found ( P>0.05). There were no serious complications such as infection or screw loosening after surgery in both groups. Conclusions:For lower cervical fracture and dislocation, although there are more advantages in total surgical duration, screw holding force and radiation control regarding the navigation system, and more outstanding performance in screw placement efficiency, incision length and intraoperative blood loss regarding the orthopedic robot, both of them can effectively rebuild the cervical structure, improve neurological function, relieve postoperative pain, improve screw placement accuracy and reduce facet joint injury and serious complications. Selection of the best auxiliary screw placement system should comprehensively consider patients′ conditions and the experience of the surgical team.
2.Comparative efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation
Xinnan CHENG ; Shuai LI ; Jiaojiao BAI ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhen CHANG ; Zhigang ZHAO ; Yunfei HUANG ; Mingzhe FENG ; Liang YAN ; Hua HUI ; Lingbo KONG ; Baorong HE
Chinese Journal of Trauma 2025;41(2):148-156
Objective:To compare the clinical efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation.Methods:A retrospective cohort study was conducted to analyze the clinical data of 49 patients with fracture and dislocation of the lower cervical spine who were admitted to Honghui Hospital, Xi′an Jiaotong University School of Medicine from May 2021 to October 2022, including 38 males and 11 females, aged 29-61 years [(39.3±7.3)years]. Injury segments involved C 3 in 12 patients, C 4 in 11, C 5 in 8, C 6 in 9 and C 7 in 9. Twenty-one patients were treated with S8 navigation system (navigation group, 84 screws), and 28 with TINAVI orthopedic robot (robot group, 112 screws). The two groups were compared in terms of the total surgical duration, single screw placement time, total screw placement time, distance between the screw and the anterior cortex, incision length, intraoperative radiation dose, intraoperative blood loss and length of hospital stay. The height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and American Spinal Injury Association (ASIA) grade were assessed before surgery and at 3 days after surgery. Visual analogue scale (VAS), Japanese Orthopedic Association (JOA) score and neck dysfunction index (NDI) before surgery, at 3 days, 3 months after surgery and at the last follow-up were compared. The accuracy of screw placement, intraoperative invasion rate of adjacent facet joints and rate of postoperative complications (infection, screw loosening, etc.) were evaluated. Results:All the patients were followed up for 12-16 months [(13.6±1.9)months]. In the navigation group, the total surgical duration, distance from the screw to the anterior cortex and the intraoperative radiation dose were (236.2±30.6)minutes, (2.0±0.2)mm and (374.3±90.3)mGy respectively, which were significantly shorter or less than those in the robot group [(278.4±20.7)minutes, (10.6±2.9)mm and (448.4±77.9)mGy] ( P<0.01). The single screw placement time, total screw placement time, incision length and intraoperative blood loss were (3.5±0.4)minutes, (23.9±0.5)minutes, (9.1±2.4)cm and (422.2±30.4)ml respectively, which were significantly longer or more than those in the robot group [(2.6±0.2)minutes, (17.9±0.7)minutes, (6.6±2.6)cm and (360.3±56.3)ml] ( P<0.01). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). No significant differences were observed in the height of the intervertebral space, Cobb angle, sliding distance between the vertebral bodies and ASIA grade between the two groups ( P>0.05). At 3 days after surgery, the height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and ASIA grade in both groups were significantly improved when compared with those before surgery ( P<0.05 or 0.01). There were no significant differences in VAS, JOA scores or NDI between the two groups before surgery, at 3 days, 3 months after surgery and at the last follow-up ( P>0.05). The VAS, JOA scores and NDI in both groups were gradually improved at 3 days, 3 months and at the last follow-up after surgery when compared with those before surgery ( P<0.05). There was no significant difference in the accuracy of screw placement of levels 0 and 0+1 between the two groups ( P>0.05). No significant difference in the intraoperative invasion rate of adjacent facet joints between the two groups was found ( P>0.05). There were no serious complications such as infection or screw loosening after surgery in both groups. Conclusions:For lower cervical fracture and dislocation, although there are more advantages in total surgical duration, screw holding force and radiation control regarding the navigation system, and more outstanding performance in screw placement efficiency, incision length and intraoperative blood loss regarding the orthopedic robot, both of them can effectively rebuild the cervical structure, improve neurological function, relieve postoperative pain, improve screw placement accuracy and reduce facet joint injury and serious complications. Selection of the best auxiliary screw placement system should comprehensively consider patients′ conditions and the experience of the surgical team.
3.Efficacy of O-arm combined with CT three-dimensional navigation system assisted versus manual screw placement in the treatment of lower cervical fracture and dislocation
Shuai LI ; Jinpeng DU ; Jiang WANG ; Yunfei HUANG ; Zhigang ZHAO ; Zhen CHANG ; Xuefang ZHANG ; Liang YAN ; Hua HUI ; Xiaobin YANG ; Zhongkai LIU ; Lingbo KONG ; Bolong ZHENG ; Baorong HE
Chinese Journal of Trauma 2023;39(8):712-720
Objective:To compare the clinical efficacies of O-arm combined with CT three-dimensional navigation system assisted screw placement versus manual screw placement in treating lower cervical fracture and dislocation.Methods:A retrospective cohort study was used to analyze the clinical data of 41 patients with lower cervical fracture and dislocation, who were treated in Honghui Hospital, Xi′an Jiaotong University from May 2021 to February 2022. The patients included 26 males and 15 females, aged 31.5-48.6 years [(41.5±15.0)years]. The injured segments were C 3 in 3 patients, C 4 in 12, C 5 in 13, C 6 in 10 and C 7 in 3. Nineteen patients were treated with cervical pedicle screws by O-shaped arm combined with CT three-dimensional navigation system (navigation group, 76 screws) and 22 by bare hands (traditional group, 88 screws). The total operation time, effective operation time, single nail placement time, single screw correction times, screw distance from anterior cortex, intraoperative blood loss, intraoperative fluoroscopic radiation dose, incision length and length of hospital stay were compared between the two groups, and the height of intervertebral space, Cobb angle, interbody slip distance and American Spinal injury Association (ASIA) grade were compared before operation and at 3 days after operation. Visual analogue score (VAS), Japanese Orthopedic Association (JOA) score, and neck dysfunction index (NDI) were evaluated before operation, at 3 days, 3 months after operation and at the last follow-up. Accuracy of screw placement and incidence of complications (adjacent facet joint invasion, infection, screw loosening) were detected as well. Results:All the patients were followed up for 11.1-13.9 months [(12.5±1.4)months]. The total operation time, intraoperative blood loss, intraoperative fluoroscopic radiation dose and incision length in the navigation group were more or longer than those in the traditional group (all P<0.05). The effective operation time, single nail placement time, single nail correction times and screw distance from anterior cortex in the navigation group were markedly less or smaller than those in the traditional group (all P<0.05). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). There were significant improvements in the height of intervertebral space, Cobb angle and interbody slip distance between the two groups at 3 days after operation (all P<0.05). There was no significant difference in the height of intervertebral space, Cobb angle, interbody slip distance or ASIA grade between the two groups before operation or at 3 days after operation (all P>0.05). Compared with pre-operation, the VAS, JOA score and NDI were significantly improved in both groups at 3 days, 3 months after operation and at the last follow-up (all P<0.05), with further improvement with time. There was no significant difference in VAS between the two groups before operation or at 3 months after operation (all P>0.05), but it was markedly lower in the navigation group compared with the traditional group at 3 days after operation and at the last follow-up (all P<0.05). There were no significant differences in JOA score or NDI between the two groups before operation or at 3 days and 3 months after operation (all P>0.05), but both were lower in the navigation group compared with the traditional group at the last follow-up (all P<0.05). The accuracies of placement of grade 0 and grade 0+1 screws were 92.0% (70/76) and 96.6% (73/76) in the navigation group, respectively, which were markedly higher than 88.7% (78/88) and 93.5% (82/88) in the traditional group (all P<0.05). The rates of adjacent facet joint invasion of A, B, and C degrees were 71.2% (54/76), 28.8% (22/76) and 0% (0/76) in the navigation group, respectively, while the invasion rates were 60.5% (53/88), 32.3% (28/88) and 7.3% (7/88) in the traditional group ( P<0.05). No screw loosening was noted in the navigation group, but the screw loosening rate was 9.1% (8/88) in the traditional group ( P<0.01). Conclusion:Compared with manual screw placement, O-arm combined with CT three-dimensional navigation system assisted screw placement for lower cervical fracture and dislocation has the advantages of shorter effective operation time, quicker screw placement, stronger screw holding force, better cervical stability, slighter postoperative pain, higher screw placement accuracy, and lower facet joint invasion and screw loosening rates.
4.Expression, thermal stability modification and application in PHB degradation of polyhydroxyalkanoate depolymerase from Thermomonospora umbrina.
Zhigang LI ; Shiheng CHEN ; Demin KONG ; Sheng CHEN ; Lei WANG ; Jing WU
Chinese Journal of Biotechnology 2023;39(8):3351-3363
Polyhydroxyalkanoate depolymerase (PHAD) can be used for the degradation and recovery of polyhydroxyalkanoate (PHA). In order to develop a PHAD with good stability under high temperature, PHAD from Thermomonospora umbrina (TumPHAD) was heterelogously expressed in Escherichia coli BL21(DE3). At the same time, a mutant A190C/V240C with enhanced stability was obtained via rational design of disulfide bonds. Characterization of enzymatic properties showed that the mutant A190C/V240C had an optimum temperature of 60 ℃, which was 20 ℃ higher than that of the wild type. The half-life at 50 ℃ was 7 hours, at 50 ℃ which was 21 times longer than that of the wild type. The mutant A190C/V240C was used for the degradation of polyhydroxybutyrate (PHB), one of the typical PHA. At 50 ℃, the degradation rate of PHB being treated for 2 hours and 12 hours was 2.1 times and 3.8 times higher than that of the wild type, respectively. The TumPHAD mutant A190C/V240C obtained in this study shows tolerance to high temperature resistance, good thermal stability and strong PHB degradation ability, which may facilitate the degradation and recovery of PHB.
Thermomonospora
;
Actinomycetales
;
Escherichia coli/genetics*
;
Polyhydroxyalkanoates
5.A scoping review of assessment tools for care complexity of patients at home and abroad
Kexin JI ; Jie CHENG ; Wenrui LI ; Jiajia KONG ; Ruiyuan YIN ; Rui WANG ; Li ZENG ; Zhigang ZHANG
Chinese Journal of Modern Nursing 2023;29(1):110-116
Objective:To systematically retrieve the assessment tools for patient care complexity at home and abroad, and compare their release institutions, formation process, applicable population, assessment methods and main contents.Methods:Articles on patient care complexity assessment tools was retrieved through computers in PubMed, Embase, Cochrane Library, Web of Science, China National Knowledge Infrastructure, WanFang Data, China Biomedical Database, and VIP Database. The retrieval time limit was from the establishment of the database to July 2, 2022. Excel 2019 was used to extract the name, release institution, evaluation method, main content and other information of the assessment tools and compare the content characteristics of the assessment tools.Results:A total of 26 assessment tools for patient care complexity were included in this study, involving 37 articles, mainly observational studies. The 26 tools were mainly issued by institutions of higher learning, and most of them were applicable to ordinary inpatients. The assessment contents included the general situation of the patient, severity of the disease, treatment items, mental cognitive function, mental health, socio-economic support and compliance.Conclusions:At home and abroad, the patient care complexity evaluation tools are mainly used to evaluate ordinary adult inpatients. There are few tools to evaluate children, the elderly, Intensive Care Unit (ICU) and other special types of patients, and there is a lack of relevant intervention research. In China, there are few tools for evaluating patient care complexity involving indicators related to mental cognitive function, which suggests that nurses can consider the mental cognitive function of patients when building relevant assessment tools in the future. In addition, the application effect of such tools in patient risk identification and safety management, nursing human resource allocation and other fields should be verified.
6.Single-cell profiling of the copy-number heterogeneity in colorectal cancer
Shiyu SONG ; Lin FENG ; Kexing XI ; Zhigang SUN ; Deyang KONG ; Zhenkai LUO ; Wei PEI ; Haizeng ZHANG
Chinese Medical Journal 2023;136(6):707-718
Background::With functionally heterogeneous cells, tumors comprise a complex ecosystem to promote tumor adaptability and evolution under strong selective pressure from the given microenvironment. Diversifying tumor cells or intra-tumor heterogeneity is essential for tumor growth, invasion, and immune evasion. However, no reliable method to classify tumor cell subtypes is yet available. In this study, we introduced the single-cell sequencing combined with copy number characteristics to identify the types of tumor cells in microsatellite stable (MSS) colorectal cancer (CRC).Methods::To characterize the somatic copy number alteration (SCNA) of MSS CRC in a single cell profile, we analyzed 26 tissue samples from 19 Korean patients (GSE132465, the Samsung Medical Center [SMC] dataset) and then verified our findings with 15 tissue samples from five Belgian patients (GSE144735, the Katholieke Universiteit Leuven 3 [KUL3] dataset). The Cancer Genome Atlas (TCGA) cohort, GSE39582 cohort, and National Cancer Center (NCC) cohort (24 MSS CRC patients were enrolled in this study between March 2017 and October 2017) were used to validate the clinical features of prognostic signatures.Results::We employed single cell RNA-sequencing data to identify three types of tumor cells in MSS CRC by their SCNA characteristics. Among these three types of tumor cells, C1 and C3 had a higher SCNA burden; C1 had significant chromosome 13 and 20 amplification, whereas C3 was the polar opposite of C1, which exhibited deletion in chromosome 13 and 20. The three types of tumor cells exhibited various functions in the tumor microenvironment and harbored different mutations. C1 and C2 were linked to the immune response and hypoxia, respectively, while C3 was critical for cell adhesion activity and tumor angiogenesis. Additionally, one gene ( OLFM4) was identified as epithelium-specific biomarker of better prognosis of CRC (TCGA cohort: P = 0.0110; GSE39582 cohort: P= 0.0098; NCC cohort: P= 0.0360). Conclusions::On the basis of copy number characteristics, we illustrated tumor heterogeneity in MSS CRC and identified three types of tumor cells with distinct roles in tumor microenvironment. By understanding heterogeneity in the intricate tumor microenvironment, we gained an insight into the mechanisms of tumor evolution, which may support the development of therapeutic strategies.
7.Meta-analysis of effects of neuromuscular electrical stimulation of lower limbs on patients with mechanical ventilation in intensive care unit
Jie CHENG ; Jiajia KONG ; Rui WANG ; Kexin JI ; Huiya GAO ; Li YAO ; Nannan DING ; Zhigang ZHANG
Chinese Critical Care Medicine 2021;33(10):1243-1248
Objective:To evaluate the effect of lower limb neuromuscular electrical stimulation (NMES) on mechanical ventilation patients in intensive care unit (ICU).Methods:Databases including the Cochrane Library, PubMed, Web of Science, Embase, SinoMed, CNKI, VIP and Wanfang database were searched from inception to May 2021. Randomized controlled trails (RCT) about the influence of NMES of lower limbs in patients with mechanical ventilation in ICU were collected. Routine rehabilitation measures were implemented in the control group, while the combination of routine rehabilitation and NMES on the lower limbs was implemented in the observation group. The literature screening, data extracting, and bias risk assessment of included studies were conducted independently by two reviewers. RevMan 5.3 software was used to perform Meta-analysis. Funnel plot was used to test publication bias.Results:A total of 8 RCT were eventually enrolled. The literature quality evaluation results showed that 1 study was grade A and 7 studies were grade B, suggesting that the quality of the included literature was relatively high. The Meta-analysis results showed that NMES in the lower extremities could effectively shorten the duration of mechanical ventilation in ICU patients [standardized mean difference ( SMD) = -0.51, 95% confidence interval (95% CI) was -0.72 to -0.31, P < 0.000 01], increase the maximum inspiratory pressure [MIP; mean difference ( MD) = 14.19, 95% CI was 9.30 to 19.09, P < 0.000 01], and improve the functional status of critically ill patients [functional status score for ICU (FSS-ICU); MD = 10.44, 95% CI was 3.12 to 17.77, P = 0.005] with statistically significances. However, there were no significant advantages in increasing the Medical Research Council (MRC) score ( MD = 2.13, 95% CI was -1.38 to 5.63, P = 0.23), reducing ICU mortality [relative risk ( RR) = 0.80, 95% CI was 0.51 to 1.24, P = 0.31], shortening length of ICU stay ( MD = -0.54, 95% CI was -3.67 to 2.59, P = 0.74), and the combined effect was not statistically significant. Funnel plot based on the duration of mechanical ventilation showed that the distribution of included articles was basically symmetrical, and no publication bias was detected. Conclusions:NMES of the lower limbs can not only shorten the ventilation duration effectively, but also improve the MIP and functional status of mechanically ventilated patients in ICU. However, it has no significant effect on the MRC score, ICU mortality and length of ICU stay of patients with mechanical ventilation. In the future, high-quality, large sample size and multi-center RCT are needed to verify the effects of NMES.
8.Reduced Firing of Nucleus Accumbens Parvalbumin Interneurons Impairs Risk Avoidance in DISC1 Transgenic Mice.
Xinyi ZHOU ; Bifeng WU ; Wenhao LIU ; Qian XIAO ; Wei HE ; Ying ZHOU ; Pengfei WEI ; Xu ZHANG ; Yue LIU ; Jie WANG ; Jufang HE ; Zhigang ZHANG ; Weidong LI ; Liping WANG ; Jie TU
Neuroscience Bulletin 2021;37(9):1325-1338
A strong animal survival instinct is to approach objects and situations that are of benefit and to avoid risk. In humans, a large proportion of mental disorders are accompanied by impairments in risk avoidance. One of the most important genes involved in mental disorders is disrupted-in-schizophrenia-1 (DISC1), and animal models in which this gene has some level of dysfunction show emotion-related impairments. However, it is not known whether DISC1 mouse models have an impairment in avoiding potential risks. In the present study, we used DISC1-N terminal truncation (DISC1-N
Animals
;
Interneurons/metabolism*
;
Mice
;
Mice, Transgenic
;
Nerve Tissue Proteins/metabolism*
;
Neurons/metabolism*
;
Nucleus Accumbens/metabolism*
;
Parvalbumins/metabolism*
9. Reduced Firing of Nucleus Accumbens Parvalbumin Interneurons Impairs Risk Avoidance in DISC1 Transgenic Mice
Xinyi ZHOU ; Wenhao LIU ; Qian XIAO ; Pengfei WEI ; Zhigang ZHANG ; Liping WANG ; Jie TU ; Xinyi ZHOU ; Pengfei WEI ; Yue LIU ; Jie WANG ; Liping WANG ; Jie TU ; Bifeng WU ; Wenhao LIU ; Wei HE ; Ying ZHOU ; Xu ZHANG ; Weidong LI ; Yue LIU ; Jie WANG ; Jufang HE ; Jufang HE
Neuroscience Bulletin 2021;37(9):1325-1338
A strong animal survival instinct is to approach objects and situations that are of benefit and to avoid risk. In humans, a large proportion of mental disorders are accompanied by impairments in risk avoidance. One of the most important genes involved in mental disorders is disrupted-in-schizophrenia-1 (DISC1), and animal models in which this gene has some level of dysfunction show emotion-related impairments. However, it is not known whether DISC1 mouse models have an impairment in avoiding potential risks. In the present study, we used DISC1-N terminal truncation (DISC1-N
10. Effectiveness of the "Internet Plus-based AIDS Comprehensive Prevention Service System" among MSM in Guangzhou
Yuzhou GU ; Weibin CHENG ; NgaiSie WONG ; Fei ZHONG ; Yanshan CAI ; Yefei LUO ; Zhigang HAN ; Weiyun HE ; Qi LIU ; Jiewei LIU ; Huifang XU
Chinese Journal of Epidemiology 2019;40(10):1222-1226
Objective:
To evaluate the effectiveness of the "Internet Plus-based AIDS Comprehensive Prevention Service System" among men who have sex with men in Guangzhou.
Methods:
Data through case-reporting and follow-up programs on MSM HIV/AIDS in Guangzhou was collected from the China Information System for Disease Control and Prevention, which including those from the referral and follow-up treatment compliance programs in 2008-2014 (pre-treatment) and 2017-2018 (post-treatment). According to the types of care services, three groups were set as: with "Internet Plus" service, with 'HIV counseling/testing service’ or with 'routine medical service’. General Estimating Equation (GEE) was used to analyze the follow up situation of HIV/AIDS cases, annually. Cox proportional hazard regression model was used to analyze the proportions of treatment referral, within the 30 days of diagnosis.
Results:
Before the implementation of immediate treatment after HIV diagnosis, 90.6

Result Analysis
Print
Save
E-mail