1.Study on the evaluation based on real-world data for clinical use of two kinds of absorbable hemostatic gauzes
Yan YANG ; Zhengying QIAN ; Zhifang PENG ; Zhenzhu CHEN
China Medical Equipment 2025;22(2):121-125
Objective:To investigate the changing trends and influencing factors of two kinds of absorbable hemostatic gauze in clinical use based on real-world data,so as to provide a reference for the refined management of absorbable hemostatic gauze.Methods:Data of surgical samples of a total of 34658 pieces of absorbable hemostatic gauzes,whose brand include brand A and brand B,in 27,468 surgeries of the Affiliated Wuxi People's Hospital of Nanjing Medical University between January 1,2015 and December 31,2023 were selected.In them,12729 surgeries used hemostatic gauzes(18,457 pieces)of brand A,and 14,739 surgeries used hemostatic gauzes(16,201 pieces)of brand B.The changing trends of the usage and cost of two kinds of absorbable hemostatic gauzes were compared and analyzed,which correlations of that with the different indicators of workload also were compared and analyzed.Results:The usage amount of absorbable hemostatic gauze of brand B increased annually,which had higher average costs per surgery but lower average usage amount per surgery.Brand B was mainly used in surgery of level-4.Both the usage amounts of brand A(18,457 pieces)and brand B(16,201 pieces)showed a positive correlation with the proportion of patients with difficult and critically ill(r=0.232,0.593,P<0.05),as well as with the proportion of medical consumables expenditure(r=0.334,0.491,P<0.05).Compared to brand A,brand B demonstrated a stronger positive correlation with the proportion of patients with difficult and critically ill,and the proportion of consumables expenditure.However,there was no significant correlation between the usage amount of each brand and the number of inpatients who received surgeries(P>0.05).The usage amount of absorbable hemostatic gauze of each brand was negative correlation with the proportion of pharmaceutical expenditure(r=-0.538,-0.696,P<0.05).Conclusion:The evaluation based on real-world data for clinical use of absorbable hemostatic gauze can reveal that brand B is gradually replacing brand A in clinical application.In clinical practice,the surgery with higher-level more prefers to use brand B.This result can guide management departments to monitor the use of absorbable hemostatic gauze.However,the balance between clinical demand and cost-effectiveness also should be considered,so as to promote the rational use of hemostatic materials,and ensure effective allocation for resource.
2.MicroPET/CT-based exploration of the effects of acute sleep deprivation on glucose metabolism and neuroinflammation in rat brain
Mengya DAI ; Zhenyu XIANG ; Yan ZHANG ; Chaofeng LIU ; Jie GAO ; Zhixing QIN ; Hongliang WANG ; Zhifang WU ; Jianguo LI ; Sijin LI
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(9):555-559
Objective:To investigate the effects of acute sleep deprivation (ASD) on hippocampal glucose metabolism and neuroinflammation in rat models.Methods:Twenty SD rats (10 males and 10 females) were divided into four groups (five in each group) by random sampling method: female ASD group, male ASD group, female control group, and male control group. Among them, the ASD group constructed the ASD model. After 72h sleep deprivation, all rats underwent 18F-FDG and N, N-diethyl-2-(2-(4-(2- 18F-fluoroethoxy)phenyl)-5, 7-dimethylpyrazolo[1, 5-a]pyrimidin-3-yl)acetamide ( 18F-DPA-714) microPET/CT brain imaging in 2d to compare the changes of 18F-FDG and 18F-DPA-714 SUV mean in the hippocampus of rats. Brain histopathology, immunohistochemistry and immunofluorescence staining were detected in rats. Independent-sample t test was used to analyze the data. Results:18F-FDG imaging showed the hippocampal SUV mean between ASD group and control group (female: 4.11±0.35 vs 1.89±0.28; male: 3.43±0.47 vs 2.02±0.54) were statistically significant ( t values: 9.65, 3.92, P values: <0.001, 0.002). 18F-DPA-714 imaging showed the hippocampal SUV mean between ASD group and control group (females: 0.28±0.01 vs 0.28±0.02; male: 0.26±0.02 vs 0.31±0.04) were not statistically significant ( t values: -0.18, -2.24, P values: 0.859, 0.056). The 18×10 3 translocator protein (TSPO) immunohistochemistry showed the expression in the hippocampal region of the brain between ASD group and control group (female: 0.19±0.02 vs 0.19±0.01; male: 0.21±0.01 vs 0.20±0.01) were not statistically different ( t values: -0.48, -1.67, P values: 0.651, 0.139). Immunofluorescence staining showed that microglial cytosol in the hippocampal region of the brain decreased after 72h of ASD, and the protrusion points and surrounding branches were significantly reduced. Conclusion:Increased hippocampal glucose metabolism in rats is observed after 72 h of ASD without significant neuroinflammation.
3.Evaluation of efficacy of a Chinese herbal mask in the treatment of melanized-type melasma by stereological measurements
Xiao MENG ; Junhui WANG ; Zhifang YAN ; Ning WANG ; Bingnan CUI
Chinese Journal of Dermatology 2025;58(1):53-59
Objective:To evaluate the efficacy and safety of a Chinese herbal mask in the treatment of melanized-type melasma by stereological measurements.Methods:A randomized, controlled, evaluator- and statistician-blind clinical study was conducted. A total of 116 patients with melasma who met the inclusion and exclusion criteria were selected and equally divided into two groups by using a random number table method, with 58 patients in each group. The treatment group received topical treatment with a Chinese herbal mask once a night, while the control group received topical hydroquinone cream in the morning and evening twice daily. The course of treatment lasted 12 weeks, with follow-ups every 4 weeks, and an additional follow-up was performed 12 weeks after discontinuation of treatment. A facial image analyzer and a reflectance confocal microscopy (RCM) were used to collect images before and after treatment. Melasma area and severity index (MASI) scores and RCM scores served as outcome measures, and stereological measurement methods were employed to compare scores before and after treatment; response rates and recurrence rates were calculated, and adverse reactions were observed and recorded. Statistical analyses were performed using the chi-square test and t test. Results:A total of 54 patients in the treatment group and 47 patients in the control group completed the study. After 4- and 8-week treatment, there were no significant differences in MASI scores or RCM scores between the two groups (all P > 0.05) ; after 12-week treatment, the MASI scores and RCM scores were significantly lower in the treatment group (2.91 ± 1.16, 5.48 ± 1.60, respectively) than in the control group (3.99 ± 2.03, 6.66 ± 1.88, t = -3.32, -3.37, respectively, both P < 0.01). After the end of treatment, there was no significant difference in the response rate between the treatment group (44/54, 81.5%) and the control group (34/47, 72.3%; χ2 = 0.12, P > 0.05). Twelve weeks after discontinuation of treatment, 2 patients (3.7%) relapsed in the treatment group, while 15 (31.9%) relapsed in the control group, showing a significant difference in recurrence rates between the two groups ( χ2 = 12.34, P < 0.01). Adverse reactions occurred in 2 patients (3.7%) in the treatment group and 6 (11.5%) in the control group, and there was no significant difference in the incidence of adverse reactions between the two groups ( χ2 = 1.34, P > 0.05) . Conclusions:The Chinese herbal mask was safe and effective in the treatment of melanized-type melasma. The application of the facial image analyzer and RCM technology in combination with stereological measurement methods has certain value in reducing the subjectivity in efficacy evaluation for melasma.
4.Design and application of a cardiopulmonary resuscitation compression depth limiting device.
Zhifang XUE ; Shuao ZHAO ; Hao LI ; Rongzhao GU ; Rong HUA ; Xianliang YAN
Chinese Critical Care Medicine 2025;37(2):180-182
During cardiopulmonary resuscitation (CPR), the depth of compression is a critical factor affecting the effectiveness of the rescue and the patient's prognosis. However, it is difficult to master the correct compression depth in manual CPR. If the compression depth is too deep, it may cause rib fractures, while insufficient compression depth may fail to establish effective circulation. Although most existing manual CPR compression depth control devices can indicate the depth but lack direct limiting functions. Against this background, led by a team of faculty and students from the Department of Emergency and Rescue Medicine at Xuzhou Medical University, on the basis of the development of a portable CPR protection device (National Invention Patent of China, patent number: ZL 2021 1 0309001.4), the device's compression depth limiting performance was further expanded, and then a new type of CPR compression depth limiting device suitable for different body types was developed. This device has applied for a National Invention Patent of China (patent application number: ZL 2023 1 0644910.2) and has been granted a National Utility Model Patent of China (patent number: ZL 2023 2 1384853.0). The device consists of a horizontal support beam, a vertical sliding beam, a guide block, a rotating shaft, a rotating arm, a limit slider and a limit pin. The horizontal support beams of the two limit devices are fixed horizontally to the horizontal side beams of the portable CPR protection device by bolts, and the connecting arms at the bottom of the vertical sliding beams are fixedly connected with the pressing mechanism, so that precise control of the pressing depth in CPR operation can be realized according to the patient's body size by the mechanical linkage of the vertical sliding beams and the rotating arms, as well as by the blocking and limiting effect of the rotating arms and the guiding blocks on the limiting sliders. It can prevent the occurrence of complications such as chest wall fractures, and thereby increase the success rate of manual CPR, and its structure is simple, low-cost, and suitable for social popularization.
Cardiopulmonary Resuscitation/instrumentation*
;
Humans
;
Equipment Design
;
Pressure
5.Evaluation of efficacy of a Chinese herbal mask in the treatment of melanized-type melasma by stereological measurements
Xiao MENG ; Junhui WANG ; Zhifang YAN ; Ning WANG ; Bingnan CUI
Chinese Journal of Dermatology 2025;58(1):53-59
Objective:To evaluate the efficacy and safety of a Chinese herbal mask in the treatment of melanized-type melasma by stereological measurements.Methods:A randomized, controlled, evaluator- and statistician-blind clinical study was conducted. A total of 116 patients with melasma who met the inclusion and exclusion criteria were selected and equally divided into two groups by using a random number table method, with 58 patients in each group. The treatment group received topical treatment with a Chinese herbal mask once a night, while the control group received topical hydroquinone cream in the morning and evening twice daily. The course of treatment lasted 12 weeks, with follow-ups every 4 weeks, and an additional follow-up was performed 12 weeks after discontinuation of treatment. A facial image analyzer and a reflectance confocal microscopy (RCM) were used to collect images before and after treatment. Melasma area and severity index (MASI) scores and RCM scores served as outcome measures, and stereological measurement methods were employed to compare scores before and after treatment; response rates and recurrence rates were calculated, and adverse reactions were observed and recorded. Statistical analyses were performed using the chi-square test and t test. Results:A total of 54 patients in the treatment group and 47 patients in the control group completed the study. After 4- and 8-week treatment, there were no significant differences in MASI scores or RCM scores between the two groups (all P > 0.05) ; after 12-week treatment, the MASI scores and RCM scores were significantly lower in the treatment group (2.91 ± 1.16, 5.48 ± 1.60, respectively) than in the control group (3.99 ± 2.03, 6.66 ± 1.88, t = -3.32, -3.37, respectively, both P < 0.01). After the end of treatment, there was no significant difference in the response rate between the treatment group (44/54, 81.5%) and the control group (34/47, 72.3%; χ2 = 0.12, P > 0.05). Twelve weeks after discontinuation of treatment, 2 patients (3.7%) relapsed in the treatment group, while 15 (31.9%) relapsed in the control group, showing a significant difference in recurrence rates between the two groups ( χ2 = 12.34, P < 0.01). Adverse reactions occurred in 2 patients (3.7%) in the treatment group and 6 (11.5%) in the control group, and there was no significant difference in the incidence of adverse reactions between the two groups ( χ2 = 1.34, P > 0.05) . Conclusions:The Chinese herbal mask was safe and effective in the treatment of melanized-type melasma. The application of the facial image analyzer and RCM technology in combination with stereological measurement methods has certain value in reducing the subjectivity in efficacy evaluation for melasma.
6.Study on the evaluation based on real-world data for clinical use of two kinds of absorbable hemostatic gauzes
Yan YANG ; Zhengying QIAN ; Zhifang PENG ; Zhenzhu CHEN
China Medical Equipment 2025;22(2):121-125
Objective:To investigate the changing trends and influencing factors of two kinds of absorbable hemostatic gauze in clinical use based on real-world data,so as to provide a reference for the refined management of absorbable hemostatic gauze.Methods:Data of surgical samples of a total of 34658 pieces of absorbable hemostatic gauzes,whose brand include brand A and brand B,in 27,468 surgeries of the Affiliated Wuxi People's Hospital of Nanjing Medical University between January 1,2015 and December 31,2023 were selected.In them,12729 surgeries used hemostatic gauzes(18,457 pieces)of brand A,and 14,739 surgeries used hemostatic gauzes(16,201 pieces)of brand B.The changing trends of the usage and cost of two kinds of absorbable hemostatic gauzes were compared and analyzed,which correlations of that with the different indicators of workload also were compared and analyzed.Results:The usage amount of absorbable hemostatic gauze of brand B increased annually,which had higher average costs per surgery but lower average usage amount per surgery.Brand B was mainly used in surgery of level-4.Both the usage amounts of brand A(18,457 pieces)and brand B(16,201 pieces)showed a positive correlation with the proportion of patients with difficult and critically ill(r=0.232,0.593,P<0.05),as well as with the proportion of medical consumables expenditure(r=0.334,0.491,P<0.05).Compared to brand A,brand B demonstrated a stronger positive correlation with the proportion of patients with difficult and critically ill,and the proportion of consumables expenditure.However,there was no significant correlation between the usage amount of each brand and the number of inpatients who received surgeries(P>0.05).The usage amount of absorbable hemostatic gauze of each brand was negative correlation with the proportion of pharmaceutical expenditure(r=-0.538,-0.696,P<0.05).Conclusion:The evaluation based on real-world data for clinical use of absorbable hemostatic gauze can reveal that brand B is gradually replacing brand A in clinical application.In clinical practice,the surgery with higher-level more prefers to use brand B.This result can guide management departments to monitor the use of absorbable hemostatic gauze.However,the balance between clinical demand and cost-effectiveness also should be considered,so as to promote the rational use of hemostatic materials,and ensure effective allocation for resource.
7.MicroPET/CT-based exploration of the effects of acute sleep deprivation on glucose metabolism and neuroinflammation in rat brain
Mengya DAI ; Zhenyu XIANG ; Yan ZHANG ; Chaofeng LIU ; Jie GAO ; Zhixing QIN ; Hongliang WANG ; Zhifang WU ; Jianguo LI ; Sijin LI
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(9):555-559
Objective:To investigate the effects of acute sleep deprivation (ASD) on hippocampal glucose metabolism and neuroinflammation in rat models.Methods:Twenty SD rats (10 males and 10 females) were divided into four groups (five in each group) by random sampling method: female ASD group, male ASD group, female control group, and male control group. Among them, the ASD group constructed the ASD model. After 72h sleep deprivation, all rats underwent 18F-FDG and N, N-diethyl-2-(2-(4-(2- 18F-fluoroethoxy)phenyl)-5, 7-dimethylpyrazolo[1, 5-a]pyrimidin-3-yl)acetamide ( 18F-DPA-714) microPET/CT brain imaging in 2d to compare the changes of 18F-FDG and 18F-DPA-714 SUV mean in the hippocampus of rats. Brain histopathology, immunohistochemistry and immunofluorescence staining were detected in rats. Independent-sample t test was used to analyze the data. Results:18F-FDG imaging showed the hippocampal SUV mean between ASD group and control group (female: 4.11±0.35 vs 1.89±0.28; male: 3.43±0.47 vs 2.02±0.54) were statistically significant ( t values: 9.65, 3.92, P values: <0.001, 0.002). 18F-DPA-714 imaging showed the hippocampal SUV mean between ASD group and control group (females: 0.28±0.01 vs 0.28±0.02; male: 0.26±0.02 vs 0.31±0.04) were not statistically significant ( t values: -0.18, -2.24, P values: 0.859, 0.056). The 18×10 3 translocator protein (TSPO) immunohistochemistry showed the expression in the hippocampal region of the brain between ASD group and control group (female: 0.19±0.02 vs 0.19±0.01; male: 0.21±0.01 vs 0.20±0.01) were not statistically different ( t values: -0.48, -1.67, P values: 0.651, 0.139). Immunofluorescence staining showed that microglial cytosol in the hippocampal region of the brain decreased after 72h of ASD, and the protrusion points and surrounding branches were significantly reduced. Conclusion:Increased hippocampal glucose metabolism in rats is observed after 72 h of ASD without significant neuroinflammation.
8.Quality control system based on artificial intelligence for improving imaging quality of chest CT
Meifang LI ; Caixing YUAN ; Zhimin ZHOU ; Kunlong YAN ; Yongping LIN ; Zhifang LI
Chinese Journal of Medical Imaging Technology 2024;40(2):285-289
Objective To observe the value of quality control system based on artificial intelligence(AI)for improving imaging quality of chest CT.Methods Totally 1 726 CT images obtained from 415 patients were retrospectively collected,among which 1 414 images were used for convolutional neural network(CNN)training and the rest 312 images were used for validation.Precision,Recall,F1-Score,mean average precision(mAP)and intersection over union(IOU)of quality control system based on AI for chest CT scanning were calculated.Meanwhile,21 patients with unsatisfactory chest CT who would undergo re-examination were prospectively enrolled,and chest CT scanning with quality control system based on AI were performed.The results of 2 examinations were compared.Results Precision,Recall,F1-Score,mAP and IOU of quality control system based on AI for chest CT were all good.All 21 cases were diagnosed correctly with re-examination CT based on quality control system.Among 21 cases,the first CT misdiagnosed 19 cases,the displaying of the area,volume and display quality of pulmonary nodules were not significantly different,but the morphology,boundaries,spiny protrusions,vacuolar signs,inflatable bronchial signs of nodules as well as the thickened and twisted blood vessels were obviously different between 2 times examination.The first CT missed 1 case while correctly diagnosed 1 case.Conclusion The quality control system based on AI was helpful for improving imaging quality of chest CT and increasing diagnostic efficacy.
9.Changes of interleukin-34 levels in serum and bronchoalveolar lavage fluid of patients with severe pneumonia and their prognostic value
Yuxin LIU ; Yongmin YAN ; Jianke REN ; Jianlei TANG ; Sheliang XUE ; Zhifang ZHUANG ; Run CAI ; Yanjuan ZHOU
Journal of Clinical Medicine in Practice 2024;28(24):31-36
Objective To investigate the changes in interleukin-34 (IL-34)levels in serum and bronchoalveolar lavage fluid (BALF) of patients with severe pneumonia and their prognostic value. Methods A total of 66 patients with severe pneumonia (severe pneumonia group), 35 patients with non-severe pneumonia (non-severe pneumonia group), and 27 healthy adults (control group) were enrolled. The severe pneumonia group was further divided into survival group of 38 patients and non-survival group of 28 patients based on 28-day survival. Clinical data of all subjects were analyzed. Receiver operating characteristic (ROC) curves were plotted to assess the predictive power of serum IL-34 and relative
10.ICP-MS determination of ten elemental impurities in meglumine
Junmin LAI ; Zhifang LI ; Minshan ZENG ; Juan ZHANG ; Xiaohong YAN
Drug Standards of China 2024;25(5):452-457
Objective:To establish an ICP-MS method for the determination of 10 elemental impurities in meglu-mine(APIs).Methods:The samples were processed by closed high-pressure microwave digestion,and the con-tents of the Class 1 elemental impurities arsenic(As),cadmium(Cd),mercury(Hg)and lead(Pb),the Class 2 A elemental impurities cobalt(Co),nickel(Ni)and vanadium(V),and the Class 3 elemental impurities lithium(Li),antimony(Sb)and copper(Cu)were detected by ICP-MS with total quantification.Results:The linear correlation coefficients(r)of each elemental impurity were greater than 0.997.The recoveries of the spiked samples ranged from 93.6%to 116.8%with RSD values of the recoveries lower than 7.4%.RSD values of the precision were lower than 5.4%.The content of nickel in 11 batches of the samples was lower than the permissible daily exposure(PDE)of the impurities of the elements of category 2A in the elemental guideline of ICH Q3D(R2)for oral use but higher than that of PDE of the impurities of category 2A for injection.Conclusion:The method is sensitive and precise enough to accurately determine the levels of Class 1,2A and 3 elemental impurities in meglumine.Nine batches of meglumine were found to have a high risk of nickel residue.


Result Analysis
Print
Save
E-mail