1.Finite element analysis of stress distribution of anchors at different implantation depths under different bone density conditions in rotator cuff tears
Meng WANG ; Tan LU ; Minjie LI ; Zhicheng LIU ; Xiaoyong GUO
Chinese Journal of Tissue Engineering Research 2026;30(3):561-569
BACKGROUND:Arthroscopic anchor repair has become the main treatment method for rotator cuff tears at present.Among them,the insertion status of the anchor is a key factor in the success or failure of the operation.However,currently,the impact of the insertion depth of the anchor on the stress of the bone tunnel and the anchor under different bone density conditions remains unclear.OBJECTIVE:To explore the stress distribution of the bone tunnel and the anchor when the insertion depth of the anchor varies under different bone density conditions by using three-dimensional finite element analysis technology.METHODS:The CT image data of the humerus of volunteers were collected,and the models of the humerus and the anchor were constructed by using Mimics,3-Matic,and Solidworks software.In 3-Matic,holes with distances of 0,2,4,6,and 8 mm from the surface of the humerus were respectively created at the same position of the humerus and assembled with the anchor.In Mimics,values were assigned based on the CT gray value to obtain a model with normal bone mass(T value ≥-1.0).The parameters were changed to construct models with reduced bone mass(-2.5<T value<-1.0)and osteoporosis(T value<-2.5).In each model,a 70 N pulling force was applied to the anchor along the direction tangent to the inner edge of the bone tunnel.The stress distribution and magnitude of the bone tunnel and the anchor when inserted at different depths under different bone density conditions were observed.RESULTS AND CONCLUSION:(1)When the insertion depth was the same,as the bone density decreased,the maximum equivalent stress of the anchor increased,while the maximum equivalent stress of the bone tunnel decreased.(2)When the bone density was the same,as the insertion depth of the anchor increased,the maximum equivalent stress of the anchor decreased.When the insertion depth was 4 mm,the stress of the bone tunnel was the smallest and the distribution was relatively uniform.The stress of the anchor was mainly distributed around the lower anchor hole and the proximal thread,and the stress of the bone tunnel was mainly at the part in contact with the proximal thread.The increase in the insertion depth would change the uniformity and pattern of the stress distribution,while the bone density had a relatively small impact on the stress distribution pattern.(3)It is concluded that the bone density of the humerus is crucial for the anchor repair of rotator cuff tears.It is recommended that clinicians measure the bone density of the greater tuberosity of the humerus before the operation.Excessive insertion depth of the anchor does not significantly increase its stability.Clinicians can conduct personalized preoperative assessments by using the finite element analysis method in combination with the actual situation of patients to achieve the best surgical results.
2.Finite element analysis of stress distribution of anchors at different implantation depths under different bone density conditions in rotator cuff tears
Meng WANG ; Tan LU ; Minjie LI ; Zhicheng LIU ; Xiaoyong GUO
Chinese Journal of Tissue Engineering Research 2026;30(3):561-569
BACKGROUND:Arthroscopic anchor repair has become the main treatment method for rotator cuff tears at present.Among them,the insertion status of the anchor is a key factor in the success or failure of the operation.However,currently,the impact of the insertion depth of the anchor on the stress of the bone tunnel and the anchor under different bone density conditions remains unclear.OBJECTIVE:To explore the stress distribution of the bone tunnel and the anchor when the insertion depth of the anchor varies under different bone density conditions by using three-dimensional finite element analysis technology.METHODS:The CT image data of the humerus of volunteers were collected,and the models of the humerus and the anchor were constructed by using Mimics,3-Matic,and Solidworks software.In 3-Matic,holes with distances of 0,2,4,6,and 8 mm from the surface of the humerus were respectively created at the same position of the humerus and assembled with the anchor.In Mimics,values were assigned based on the CT gray value to obtain a model with normal bone mass(T value ≥-1.0).The parameters were changed to construct models with reduced bone mass(-2.5<T value<-1.0)and osteoporosis(T value<-2.5).In each model,a 70 N pulling force was applied to the anchor along the direction tangent to the inner edge of the bone tunnel.The stress distribution and magnitude of the bone tunnel and the anchor when inserted at different depths under different bone density conditions were observed.RESULTS AND CONCLUSION:(1)When the insertion depth was the same,as the bone density decreased,the maximum equivalent stress of the anchor increased,while the maximum equivalent stress of the bone tunnel decreased.(2)When the bone density was the same,as the insertion depth of the anchor increased,the maximum equivalent stress of the anchor decreased.When the insertion depth was 4 mm,the stress of the bone tunnel was the smallest and the distribution was relatively uniform.The stress of the anchor was mainly distributed around the lower anchor hole and the proximal thread,and the stress of the bone tunnel was mainly at the part in contact with the proximal thread.The increase in the insertion depth would change the uniformity and pattern of the stress distribution,while the bone density had a relatively small impact on the stress distribution pattern.(3)It is concluded that the bone density of the humerus is crucial for the anchor repair of rotator cuff tears.It is recommended that clinicians measure the bone density of the greater tuberosity of the humerus before the operation.Excessive insertion depth of the anchor does not significantly increase its stability.Clinicians can conduct personalized preoperative assessments by using the finite element analysis method in combination with the actual situation of patients to achieve the best surgical results.
3.Biological function of soluble α-Klotho and its protective mechanism against renal injury
Yan ZHANG ; Hui LIAO ; Zhicheng TAN ; Rongshan LI
Chinese Journal of Nephrology 2025;41(1):63-69
The α-Klotho protein is an anti-aging protein encoded by the Klotho gene and mainly exists in the renal tubules in the form of type 1 membrane protein (membrane-boundform). The extracellular domain of the membrane-bound α-Klotho protein can be cleaved and secreted into the circulation, which is called soluble α-Klotho. Soluble α-Klotho is the main form that can be detected in the body fluid. This paper mainly reviews the biological functions of soluble α-Klotho in the kidney and its possible molecular biological mechanisms, and also summarizes the role of soluble α-Klotho in various kidney diseases and the effects of α-Klotho on the other organs.
4.Research advances in yttrium-90 microsphere selective internal radiation therapy in treatment of hepatocellular carcinoma
Yongle ZHAO ; Honglin CHEN ; Han ZHANG ; Xinyue ZHU ; Zhicheng YANG ; Maoting TAN ; Hongyun ZHAO
Journal of Chongqing Medical University 2025;50(8):1035-1041
Primary liver cancer is one of the most common causes of cancer-related deaths in China,with hepatocellular carcinoma(HCC)accounting for 75%-85%.Approximately 70%of HCC patients are in the advanced stage at the time of diagnosis and miss the opportunity for radical surgery,leading to a poor prognosis.Yttrium-90 microsphere selective internal radiation therapy(90Y-SIRT),an emerging therapeutic modality,delivers radioactive microspheres via the hepatic artery to target tumors and uses beta radiation for localized tumor ablation.Compared to conventional transarterial chemoembolization and pharmacotherapy,90Y-SIRT shows the advan-tages of significant clinical benefits,good safety profiles,and broad applicability across diverse patient populations.This article re-views the advances in the application of 90Y-SIRT in HCC treatment.
5.Advances in the application of multimodal molecular imaging in the diagnosis and treatment of primary liver cancer
Yongle ZHAO ; Zhicheng YANG ; Maoting TAN ; Honglin CHEN ; Han ZHANG ; Hongyun ZHAO
Journal of Chongqing Medical University 2025;50(10):1375-1378
Primary liver cancer is a malignant tumor with high incidence and mortality rates worldwide,and the early diagnosis of pri-mary liver cancer and the optimization of precise treatment strategies have become critical issues in the healthcare field.Due to the in-sufficient capabilities for molecular characterization,it is increasingly difficult for traditional imaging techniques to meet clinical needs in the era of precision medicine.Multimodal molecular imaging technology integrates the advantages of imaging modalities such as ul-trasound imaging,magnetic resonance imaging,and optical imaging,thereby achieving synergistic enhancement between molecular bio-logical information of liver cancer and precise anatomical localization and demonstrating a significant value in the diagnosis and treat-ment of liver cancer.This article reviews the advances in the application of multimodal molecular imaging in the early diagnosis,pre-cise treatment,and therapeutic efficacy monitoring of liver cancer.
6.Biological function of soluble α-Klotho and its protective mechanism against renal injury
Yan ZHANG ; Hui LIAO ; Zhicheng TAN ; Rongshan LI
Chinese Journal of Nephrology 2025;41(1):63-69
The α-Klotho protein is an anti-aging protein encoded by the Klotho gene and mainly exists in the renal tubules in the form of type 1 membrane protein (membrane-boundform). The extracellular domain of the membrane-bound α-Klotho protein can be cleaved and secreted into the circulation, which is called soluble α-Klotho. Soluble α-Klotho is the main form that can be detected in the body fluid. This paper mainly reviews the biological functions of soluble α-Klotho in the kidney and its possible molecular biological mechanisms, and also summarizes the role of soluble α-Klotho in various kidney diseases and the effects of α-Klotho on the other organs.
7.Formulation and Analysis on the Standard of Construction of Medication Safety Culture
Wenjing HOU ; Su SHEN ; Aiping WEN ; Jin LU ; Jiancun ZHEN ; Wei ZHANG ; Dan MEI ; Zhicheng GONG ; Yubo WU ; Qunhong SHEN ; Weiyi FENG ; Ling TAN ; Yanhua ZHANG ; Fang LIU ; Xiaole ZHANG
Herald of Medicine 2024;43(7):1079-1083
The construction of a medication safety culture is important for medication safety management and rational drug use.The construction of medication safety culture standards is formulated based on relevant national policies and regulations,accreditation standards for hospitals,expert opinions,the current situation,and the development trend of the healthcare industry.With scientificity,general applicability,instructive guidance,and practicality,they standardized basic requirements,management processes,and improvement of the construction of medication safety culture.To facilitate understanding and the implementation of the standards,we describe the process of standards formulation and explain the key points of the standards.
8.Retrospective analysis of 350 cases with dissection of lymph nodes posterior to right recurrent laryngeal nerve in endoscopic thyroidectomy through gasless axillary posterior approach
Zhicheng ZHANG ; Tingting LI ; Shitong YU ; Junna GE ; Zhigang WEI ; Baihui SUN ; Weisheng CHEN ; Jie TAN ; Shangtong LEI
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2024;59(1):21-26
Objective:To evaluated the safety and feasibility of dissection of lymph nodes posterior to right recurrent laryngeal nerve (ⅥB compartment) in endoscopic thyroidectomy through gasless axillary posterior approach.Methods:A total of 350 cases with right lobe papillary thyroid carcinoma (PTC) who underwent endoscopic lobectomy, isthmusectomy and central compartment neck dissection via gasless axillary posterior approach based at the Department of General Surgery, Nanfang Hospital, Southern Medical University from June 2020 to December 2022 were retrospectively analyzed. Summarize the clinical, pathological characteristics, and postoperative complications of the patients. SPSS 25.0 was used for statistical analysis of the data.Results:All 350 patients underwent endoscopic surgery successfully, with no conversion to open surgery. There were 303 females and 47 males, with an average age of (36.3±9.2) years. Of those, 287 patients were in pT1a stage, 62 in pT1b stage, and one patient in pT2 stage. There was no T3 or T4 stage patient. The mean numbers of yielded lymph nodes in right central compartment and ⅥB compartment were 8.11±4.65 (range, 1-31) and 2.62±1.86 (range, 1-12), respectively. ⅥB compartment metastasis was detected in 52 (14.86%) of 350 patients. The incidence of transient recurrent laryngeal nerve injury was 0.86%(3/350). Postoperative hematoma occurred in three patients (0.86%).Conclusion:The dissection of ⅥB compartment in endoscopic thyroidectomy through gasless axillary posterior approach is safe and feasible in selected PTC patients
9. Clinical value of MRI in the diagnosis of placental implantation
Minyi TAN ; Yanni ZENG ; Qiang YUAN ; Zhicheng WU ; Jianfeng PENG
Chinese Journal of Primary Medicine and Pharmacy 2019;26(16):1999-2002
Objective:
To determine imaging features that may help predict the presence of placenta accreta, placenta increta or placenta percreta on prenatal MRI scanning in order to identify the most diagnostic findings.
Methods:
The prenatal MRI scan data of placenta accreta, placenta increta or placenta percreta (placenta implantation group,
10.Application of Low Radiation Dose Combined with Low-dose Contrast Agent in Thyroid CT Enhanced Scan
Jianhao LIANG ; Xinjin ZHU ; Kanrong YANG ; Jie LIU ; Zhicheng TAN ; Jinling ZHONG
Chinese Journal of Medical Imaging 2017;25(2):105-108
Purpose To explore the feasibility of low radiation dose combined with lowdose contrast agent in thyroid CT enhanced scan and investigate the benefit of reducing radiation hazard and contrast agent damage to thyroid.Materials and Methods 120 patients assigned for thyroid enhanced CT scan were prospectively and randomly divided into four groups (each group was 30 patients).Group A:radiation dose 120 kV,180 mA,contrast agent dose 1.2 ml/kg;group B:radiation dose 120 kV,180 mA,contrast agent dose 1.0 ml/kg;group C:radiation dose 100 kV,100 mA,contrast agent dose 1.2 ml/kg;group D:radiation dose 100 kV,100 mA,contrast agent dose 1.0 ml/kg.CT values,background sign,background noise of thyroid were measured;signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated;CT dose index of volume (CTDIvol),dose length product (DLP),and the effective dose (ED) were recorded and calculated.The image quality was evaluated and the data was statistically analyzed by two radiologists.Results CT values,background sign and background noise of thyroid,as well as CTDIvol,DLP,ED among four groups were statistical significant (P<0.05);there was no significant difference in SNR,CNR and image quality scores among four groups (P>0.05).Conclusion It is beneficial of reducing radiation hazard and side-effect of contrast agent from low radiation dose combined with low-dose contrast agent under the condition of ensuring diagnostic image quality.

Result Analysis
Print
Save
E-mail