1.Different methods in predicting mortality of pediatric intensive care units sepsis in Southwest China
Rong LIU ; Zhicai YU ; Changxue XIAO ; Shufang XIAO ; Juan HE ; Yan SHI ; Yuanyuan HUA ; Jimin ZHOU ; Guoying ZHANG ; Tao WANG ; Jianyu JIANG ; Daoxue XIONG ; Yan CHEN ; Hongbo XU ; Hong YUN ; Hui SUN ; Tingting PAN ; Rui WANG ; Shuangmei ZHU ; Dong HUANG ; Yujiang LIU ; Yuhang HU ; Xinrui REN ; Mingfang SHI ; Sizun SONG ; Jumei LUO ; Juan LIU ; Juan ZHANG ; Feng XU
Chinese Journal of Pediatrics 2024;62(3):204-210
Objective:To investigate the value of systemic inflammatory response syndrome (SIRS), pediatric sequential organ failure assessment (pSOFA) and pediatric critical illness score (PCIS) in predicting mortality of pediatric sepsis in pediatric intensive care units (PICU) from Southwest China.Methods:This was a prospective multicenter observational study. A total of 447 children with sepsis admitted to 12 PICU in Southwest China from April 2022 to March 2023 were enrolled. Based on the prognosis, the patients were divided into survival group and non-survival group. The physiological parameters of SIRS, pSOFA and PCIS were recorded and scored within 24 h after PICU admission. The general clinical data and some laboratory results were recorded. The area under the curve (AUC) of the receiver operating characteristic curve was used to compare the predictive value of SIRS, pSOFA and PCIS in mortality of pediatric sepsis.Results:Amongst 447 children with sepsis, 260 patients were male and 187 patients were female, aged 2.5 (0.8, 7.0) years, 405 patients were in the survival group and 42 patients were in the non-survival group. 418 patients (93.5%) met the criteria of SIRS, and 440 patients (98.4%) met the criteria of pSOFA≥2. There was no significant difference in the number of items meeting the SIRS criteria between the survival group and the non-survival group (3(2, 4) vs. 3(3, 4) points, Z=1.30, P=0.192). The pSOFA score of the non-survival group was significantly higher than that of the survival group (9(6, 12) vs. 4(3, 7) points, Z=6.56, P<0.001), and the PCIS score was significantly lower than that of the survival group (72(68, 81) vs. 82(76, 88) points, Z=5.90, P<0.001). The predictive value of pSOFA (AUC=0.82) and PCIS (AUC=0.78) for sepsis mortality was significantly higher than that of SIRS (AUC=0.56) ( Z=6.59, 4.23, both P<0.001). There was no significant difference between pSOFA and PCIS ( Z=1.35, P=0.176). Platelet count, procalcitonin, lactic acid, albumin, creatinine, total bilirubin, activated partial thromboplastin time, prothrombin time and international normalized ratio were all able to predict mortality of sepsis to a certain degree (AUC=0.64, 0.68, 0.80, 0.64, 0.68, 0.60, 0.77, 0.75, 0.76, all P<0.05). Conclusion:Compared with SIRS, both pSOFA and PCIS had better predictive value in the mortality of pediatric sepsis in PICU.
2.Comparison clinical and radiographic outcomes between plate/cage constructs and zero-profile devices in the treatment of cervical spondylotic myelopathy patients with cervical kyphosis
Chao WANG ; Zhicai SHI ; Jingfeng LI ; Ningfang MAO ; Qianghua LI ; Jiabin YUAN ; Xumiao LIN ; Zebin HUANG
Chinese Journal of Orthopaedics 2020;40(22):1513-1521
Objective:To compare the clinical outcomes and correction effects of kyphosis between Zero-profile device (Zero-p) and plate/cage structures (PCC) in treating cervical spondylotic myelopathy (CSM) patients with cervical kyphosis.Methods:From August 2016 to July 2018, a total of 54 cases of cervical spondylotic myelopathy patients with cervical kyphosis were analyzed retrospectively, including 26 cases treated with Zero-p and 28 cases treated with PCC system. There was no significant difference between the two groups in gender, age, body mass index (BMI) and operative segment. The operation duration and the blood loss were recorded. The clinical outcomes of the patients were measured by visual analogue score (VAS) for neck pain and Japanese Orthopedic Association (JOA) score for neurological function. Moreover, JOA recovery rate was obtained to assess the surgical results. The cervical lordosis (C 2-C 7 Cobb angle), the Cobb angle of the operation segment, the C 2-C 7 vertical axis (C 2 SVA) and the cervical range of motion (ROM) were measured on the lateral and dynamic radiographs of the cervical spine, respectively. Results:In the Zero-p group, the operation duration was 83.0±14.9 (range 60-120) min, intraoperative blood loss was 70.5±27.3 (range 30-150) ml. In PCC group, the operation duration was 100.0±23.9 (range 65-145) min, intraoperative blood loss was 104.2±38.8 (range 30-250) ml. There were significant difference in above parameters between two groups ( t=3.40, 2.06; P=0.00, 0.04). The follow-up duration in Zero-p group was 30.4±5.8 (range 24-36) months and 31.2±4.9 (range 24-36) months in PCC group without significant difference ( t=1.061, P=0.291). The VAS/JOA score of the Zero-p group was improved from (5.9±1.0)/(9.2±1.7) preoperatively to (2.1±0.8)/(14.9±1.0) at 1 month postoperatively, and to (3.4±1.0)/(15.1±0.9) at the last follow-up. The difference between them was statistically significant ( F=130.96, 221.40, P=0.00). The VAS/JOA score of the PCC group was improved from (5.9±1.1)/(8.7±1.6) preoperatively to (2.3±0.9)/(14.9±1.0) at 1 month after surgery, and to (2.6±0.9)/(15.6±1.1) at the last follow-up. The difference between them was statistically significant ( F=303.35, 126.64, P=0.00). However, the VAS score of neck pain in the Zero-p group at the last follow-up was significantly deteriorated, which was significantly higher than that in PCC group ( P<0.05). The cervical lordosis/operative segment Cobb angle in the Zero-p group was improved from preoperative (-6.7°±2.7°)/(-6.5°±3.2°) preoperatively to (14.2°±4.9°)/(12.9°±4.9°) at 1 month postoperatively, and to (5.9°±4.7°)/(5.0°±4.0°) at the last follow-up with statistical significance ( F=196.98, 179.97, P=0.00). The cervical lordosis/operative segment Cobb angle in the PCC group was improved from (-5.7°±3.5°)/(-6.1°±4.0°) preoperatively to (13.9°±6.9°)/(13.0°±6.4°) 1 month after surgery, and to (11.0°±5.5°)/(10.4°±5.6°) at the last follow-up with statistical significance ( F=127.27, 119.98, P=0.00). However, the cervical lordosis and operative segment Cobb angle at the last follow-up in the Zero-p group were significantly lost compared with those at 1 month after surgery, which were significantly smaller than those in the PCC group ( P<0.05). The incidence of dysphagia after operation was 7.7% (2/26) in the Zero-p group and 28.6% (8/28) in the PCC group (χ 2=5.11, P=0.02). Conclusion:For CSM patients with cervical kyphosis, PCC could achieve much better mid-term kyphotic correction and clinical outcomes. However, Zero-p should be avoided as much as possible.
3.Analysis of the effect of double incision double plate internal fixation in the treatment of complex fractures of tibial plateau
Xuezhong MA ; Jian WANG ; Zhicai ZHAO ; Xinghua LIU ; Jinzhu SHI
Chinese Journal of Primary Medicine and Pharmacy 2018;25(8):991-994
Objective To study the clinical efficacy and safety of double incision double plate internal fixation in the treatment of complex fractures of tibial plateau .Methods According to the different treatment methods , 83 patients with tibial plateau complex fractures were divided into double plate group ( 51 cases ) and locking plate group ( 32 cases ) .The surgical indicators , treatment efficacy and complications were compared between the two groups .Results The time of implantation ,hospital stay and fracture healing time in the observation group were signif-icantly shorter than those in the control group [(9.36 ±2.14) d vs.(13.24 ±2.99) d;(11.71 ±1.32) d vs. (13.41 ±2.23)d;(13.27 ±1.83)weeks vs.(15.82 ±2.18)weeks],the differences were statistically significant (t=6.813,4.368,5.736,all P<0.05).The excellent rates of HSS score in the observation group and the control group were 94.12%and 93.75%,respectively,and there was no statistically significant difference (χ2 =0.746,P>0.05).The incidence rate of complications in the observation group was significantly lower than that in the control group(5.88%vs.21.88%) (χ2 =4.746,P<0.05).Conclusion Double-incision plate internal fixation surgery for tibial plateau complex fractures is effective ,has fast postoperative recovery ,high safety,and it is worthy of clinical application in a wide range of popularization .
4.Anatomical study on the medial cubital vein in adult cadavers
Jianzhong WANG ; Wenlong SHI ; Zhicai ZHANG ; Yongqiang CAI ; Jian WANG ; Xiaohe LI
Journal of Regional Anatomy and Operative Surgery 2015;(3):297-299
Objective To provide regional anatomical data for clinical application through observing the type, length and diameter of variation in the medial cubital vein of upper limb. Methods Dissected the medial cubital vein of upper limb in 35 (70 sides) adult cadavers (male 38, female 7), and observed the morphological structure. The length and vessel diameter of the medial cubital vein were measured. Results The variation of the medial cubital vein of upper limb was divided into six type. TypeⅠincluded 29 cases (41. 43%) of male and 8 cases (11. 43%) of female;Type Ⅱ included 14 cases (20. 00%) of male and 4 cases (5. 71%) of female;Type Ⅲ included 7 cases (10. 00%) of male and 2 cases (2. 86%) of female;TypeⅣincluded 3 cases (4. 29%) of male and 0 cases of female;TypeⅤincluded 2 cases (2. 86%) of male and 0 cases of female;TypeⅥincluded 1 cases (1. 43%) male and 0 cases of female. Conclusion This study enriched anthropology data of the medial cubital vein and it has the role of guiding in clinical applications.
5.Implants and techniques of lumbar non-fusion
Chinese Journal of Tissue Engineering Research 2007;0(17):-
In recent years, lumbar non-fusion as a novel technique of spinal surgery, can reserve the integrated function of intervertebral disc and zygapophysial joint, maintain or recover the segmental movement to a normal level, and have no adverse effect on the neighboring segments. It is possible for the lumbar non-fusion to substitute lumbar fusion, but its application requires a reasonable and perfect verification. The implants’ safety and biocompatibility with the host need further clinical researches for the satisfactory outcomes.
6.Long segment pedicle screw/rod internal fixation system insertion by augmentation and restoration with bone cement for degenerative scoliosis accompanied by osteoporosis in 22 cases
Lin YU ; Zhicai SHI ; Yushu BAI ; Shailin ZHANG
Chinese Journal of Tissue Engineering Research 2007;0(35):-
20?) or vertebral semiluxation and vertebral pathological fracture group (n=14),which was treated with full laminectomy and limited correction with pedicle screw/rod internal fixation system by augmentation and restoration with bone cement in the screw tract; mild coronal plane deformity (Cobb’s angle
7.Interspinous process device in basic study and clinical application
Chinese Journal of Tissue Engineering Research 2007;0(44):-
Interspinous process device is a kind of non-fusion implant for posterior spinal surgery.It is classified by static system and dynamic system according to its characteristics.With rapid development of internal fixator manufacture,materials for interspinous process device become increasing,such as bone allograft,titanium,poly(ether-ether-ketone) and lactoprene composite.A large number of experimental and clinical researches reveal the advantages of this technology in degenerative spinal stenosis,intervertebral original lower back pain,facet syndrome,protrusion of intervertebral disk,and lumbar instability.However,there are still many problems such as the influence on the lumbar posterior column,the mechanism to lumbar disc and the effect on the stability of spine etc.In addition,the clinical indications need to validate by long-term follow up.
8.Study of complications of spinal internal fixation surgery
Dehua GAO ; Zhicai SHI ; Tiesheng HOU ; Ming LI
Academic Journal of Second Military Medical University 2001;22(5):464-466
Objective: To study the factors and preventive method of post-operative complications of spinal implant operation. Methods: The post-operative complication of 451 cases who had undergone spinal implant operation were analysed retrospectively. The relative factors of complications were analyzed. Results: Infection, thrombosis of deep vein and failed fusion were the most common complications. Among the factors, the age, operation time and blood lose during operation were closely related with the complication. Using antibiotic was effective to reduce the infection. Conclusion: It is effective to reduce the post-operative complication of spinal implant operation by proper pre-operative evaluation. Using antibiotic to control other diseases is also effective.
9.Experimental study of interbody fusion using CFR/PEEK
Zhicai SHI ; Jiashun LI ; Lianshun JIA ; Wen YUAN ; Tiesheng HOU ; Ming LI ; Xiaodong ZHU
Academic Journal of Second Military Medical University 2001;22(4):340-342
Objective: To study the biocompatibility of CFR/PEEK composite in bone tissue after implanted in lumbar intervertebral space and to evaluate its role in the interbody fusion compared to the allograft bone. Methods: Thirteen beagles were chosen among which 7 were implanted with the disk-like CFR/PEEK composite in the lumbar intervertebral space and the other 6 were implanted with allograft bone. X-ray, QCT and histological examination were employed at 6, 12 and 24 months postoperatively. Results: The X-ray results of fusion segment were in conformity with the QCT's as well as that of histological results. All animals obtained a complete fusion at 24 months. Histological examination revealed that the anterior soft tissue to the implant exhibited a nonspecific foreign body reaction with connective tissue embed the biomaterials. Carbon fragment were seen in the surrounding tissue and some of the debric were phagocytosed by foreign body giant cell. Histological examination of bone and material revealed that new bone grew along the hole of CFR/PEEK implant. Conclusion: CFR/PEEK has an excellent biocompatibility to bone tissue.
10.Recording of spared motor evoked potentials and its augmentation by 4-aminopyridine in chronic spinal cord-injured rats
Kewei YU ; Jiashun LI ; Weifang RONG ; Lianshun JIA ; Wen YUAN ; Xiaojian YE ; Zhicai SHI ; Bojun DAI
Chinese Medical Journal 2001;114(2):155-161
Objective To research the direct electrophysiological evidence of discomplete spinal cord injury (SCI) and the effect of 4-aminopyridine on it. Methods Motor evoked potentials (MEPs), both spinal cord recorded MEPs (scMEPs) and extracellularly recorded MEPs (exMEPs) were recorded and characterized on a T13 epidural electrode (scMEPs) and an extracellular microelectrode (exMEPs) for 10 normal rats and 40 rats with lesions of various severity (sham, 35?g*cm force (gcf), 70?gcf, 100?gcf impact injury) at the T8-T9 cord using the Allen's drop model. The incline plane and Tarlov techniques were used to assess clinical neurological function. Results MEPs in the normal rats were elicited by applying transcortical suprathreshold stimulation consisting of 3-4 early negative peaks (N1, N2, N3 and N4) followed by several late waves. The N1 and N2 peaks were largest in the anterior and ventrolateral funiculus, respectively, which was indicative of extrapyramidal pathways. The 100?gcf impact injuries and the cord transection abolished the MEP distal to the lesion, whereas the 35?gcf injuries resulted in a latency shift and amplitude decrement of the MEP peaks. Eighteen of the 20 rats with 70?gcf injuries showed clinical paraplegia. Among them, 7 rats had neurophysiological evidence of residual conduction pathways through the lesioned cord segment, such as the presence of N1 and N2 peaks in the scMEPs or exMEPs. After 4-aminopyridine (4-AP) administrations (1?mg/kg), the amplitude of the spared exMEP increased significantly and spread more widely. Conclusions MEPs evoked by transcortical stimulation travel mostly in the extrapyramidal tract. MEP monitoring could provide an excellent method of detecting the functional integrity of the motor tracts after SCI, and could even detect spared motor fibers after discomplete SCI. Furthermore, the use of 4-AP or other K+ channel blocking agents may be a potential treatment for patients with chronic moderate to severe SCI.

Result Analysis
Print
Save
E-mail