1.Research on quality control of medical flexible endoscope reprocessing and design of endoscope quality control workstation
Pengkai BAI ; Xiaoyang CHU ; Hai XIE ; Ximing FENG ; Jialin LI ; Rongfen WEI ; Zhicai LUO ; Hejiao HUANG ; Qiang HU
China Medical Equipment 2025;22(1):150-154
This paper summarized the current status of infection and quality control of medical flexible endoscope (abbreviation:endoscope),which can identify that defect of the quality control of endoscopic forceps channels was a major cause of nosocomial infections of endoscopy. Based on this,a multifunctional quality control workstation with forceps channel of detecting flexible endoscope,and precision components included top ends for medical endoscopes has been developed,which can clearly display residual contaminants and damages in the forceps channels and precision components after the endoscope was reprocessed. It is contribute to enhance the quality control of reprocessing endoscope,and reduce cross-infection of endoscope.
2.Research on quality control of medical flexible endoscope reprocessing and design of endoscope quality control workstation
Pengkai BAI ; Xiaoyang CHU ; Hai XIE ; Ximing FENG ; Jialin LI ; Rongfen WEI ; Zhicai LUO ; Hejiao HUANG ; Qiang HU
China Medical Equipment 2025;22(1):150-154
This paper summarized the current status of infection and quality control of medical flexible endoscope (abbreviation:endoscope),which can identify that defect of the quality control of endoscopic forceps channels was a major cause of nosocomial infections of endoscopy. Based on this,a multifunctional quality control workstation with forceps channel of detecting flexible endoscope,and precision components included top ends for medical endoscopes has been developed,which can clearly display residual contaminants and damages in the forceps channels and precision components after the endoscope was reprocessed. It is contribute to enhance the quality control of reprocessing endoscope,and reduce cross-infection of endoscope.
3.Different methods in predicting mortality of pediatric intensive care units sepsis in Southwest China
Rong LIU ; Zhicai YU ; Changxue XIAO ; Shufang XIAO ; Juan HE ; Yan SHI ; Yuanyuan HUA ; Jimin ZHOU ; Guoying ZHANG ; Tao WANG ; Jianyu JIANG ; Daoxue XIONG ; Yan CHEN ; Hongbo XU ; Hong YUN ; Hui SUN ; Tingting PAN ; Rui WANG ; Shuangmei ZHU ; Dong HUANG ; Yujiang LIU ; Yuhang HU ; Xinrui REN ; Mingfang SHI ; Sizun SONG ; Jumei LUO ; Juan LIU ; Juan ZHANG ; Feng XU
Chinese Journal of Pediatrics 2024;62(3):204-210
Objective:To investigate the value of systemic inflammatory response syndrome (SIRS), pediatric sequential organ failure assessment (pSOFA) and pediatric critical illness score (PCIS) in predicting mortality of pediatric sepsis in pediatric intensive care units (PICU) from Southwest China.Methods:This was a prospective multicenter observational study. A total of 447 children with sepsis admitted to 12 PICU in Southwest China from April 2022 to March 2023 were enrolled. Based on the prognosis, the patients were divided into survival group and non-survival group. The physiological parameters of SIRS, pSOFA and PCIS were recorded and scored within 24 h after PICU admission. The general clinical data and some laboratory results were recorded. The area under the curve (AUC) of the receiver operating characteristic curve was used to compare the predictive value of SIRS, pSOFA and PCIS in mortality of pediatric sepsis.Results:Amongst 447 children with sepsis, 260 patients were male and 187 patients were female, aged 2.5 (0.8, 7.0) years, 405 patients were in the survival group and 42 patients were in the non-survival group. 418 patients (93.5%) met the criteria of SIRS, and 440 patients (98.4%) met the criteria of pSOFA≥2. There was no significant difference in the number of items meeting the SIRS criteria between the survival group and the non-survival group (3(2, 4) vs. 3(3, 4) points, Z=1.30, P=0.192). The pSOFA score of the non-survival group was significantly higher than that of the survival group (9(6, 12) vs. 4(3, 7) points, Z=6.56, P<0.001), and the PCIS score was significantly lower than that of the survival group (72(68, 81) vs. 82(76, 88) points, Z=5.90, P<0.001). The predictive value of pSOFA (AUC=0.82) and PCIS (AUC=0.78) for sepsis mortality was significantly higher than that of SIRS (AUC=0.56) ( Z=6.59, 4.23, both P<0.001). There was no significant difference between pSOFA and PCIS ( Z=1.35, P=0.176). Platelet count, procalcitonin, lactic acid, albumin, creatinine, total bilirubin, activated partial thromboplastin time, prothrombin time and international normalized ratio were all able to predict mortality of sepsis to a certain degree (AUC=0.64, 0.68, 0.80, 0.64, 0.68, 0.60, 0.77, 0.75, 0.76, all P<0.05). Conclusion:Compared with SIRS, both pSOFA and PCIS had better predictive value in the mortality of pediatric sepsis in PICU.
4.Association between baseline hemoglobin level and early neurological deterioration after intravenous thrombolysis in patients with acute ischemic stroke
Tinghuan WANG ; Wansi ZHONG ; Zhicai CHEN ; Ke SHEN ; Huiya YE ; Zhihui YU ; Jia LUO ; Jun MA ; Min LOU
Journal of Zhejiang University. Medical sciences 2024;53(2):168-174
Objective:To investigate the association between baseline hemoglobin level and early neurologic deterioration(END)after intravenous thrombolysis in patients with acute ischemic stroke(AIS).Methods:Data of AIS patients who received intravenous thrombolytic therapy at multiple hospitals across the country between January 2017 and July 2020 were collected from the online database Acute Stroke Patients for Stroke Management Quality Evaluation(CASE-Ⅱ,NCT04487340).Binary logistic regression analysis was used to study the factors affecting the occurrence of END after intravenous thrombolytic therapy,and the correlation between baseline hemoglobin level and END was investigated by limiting cubic spline curve analysis.Results:A total of 8162 patients were included.Patients with END had lower baseline hemoglobin levels(136 and 140 g/L,P<0.01)and higher rates of anemia(24.2%and 16.9%,P<0.01)compared with non-END patients.Binary logistic regression analysis showed that baseline hemoglobin level(OR=0.995,95%CI:0.991-0.999,P<0.05)and anemia(OR=1.238,95%CI:1.055-1.454,P<0.01)were independently correlated with the occurrence of END after intravenous thrombolysis in AIS patients.Restricted cubic spline regression showed that there was a U-shaped relationship between hemoglobin level and the risk of END after intravenous thrombolysis in AIS patients(P<0.01),although this relationship was only significant in male patients(P<0.05)and not in female patients(P>0.05).Conclusion:There is a correlation between baseline hemoglobin level and the risk of END in AIS patients after intravenous thrombolysis,especially in male patients,in whom both lower and higher hemoglobin level may increase the risk of END.