1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Introduction and enlightenment of the Recommendations and Expert Consensus for Plasm a and Platelet Transfusion Practice in Critically ill Children: from the Transfusion and Anemia Expertise Initiative-Control/Avoidance of Bleeding (TAXI-CAB)
Lu LU ; Jiaohui ZENG ; Hao TANG ; Lan GU ; Junhua ZHANG ; Zhi LIN ; Dan WANG ; Mingyi ZHAO ; Minghua YANG ; Rong HUANG ; Rong GUI
Chinese Journal of Blood Transfusion 2025;38(4):585-594
To guide transfusion practice in critically ill children who often need plasma and platelet transfusions, the Transfusion and Anemia Expertise Initiative-Control/Avoidance of Bleeding (TAXI-CAB) developed Recommendations and Expert Consensus for Plasma and Platelet Transfusion Practice in Critically Ill Children. This guideline addresses 53 recommendations related to plasma and platelet transfusion in critically ill children with 8 kinds of diseases, laboratory testing, selection/treatment of plasma and platelet components, and research priorities. This paper introduces the specific methods and results of the recommendation formation of the guideline.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Study on the 90-day Feeding Experimental Background Data of SD Rats for Drug Safety Evaluation
Chao QIN ; Shuangxing LI ; Tingting ZHAO ; Chenchen JIANG ; Jing ZHAO ; Yanwei YANG ; Zhi LIN ; Sanlong WANG ; Hairuo WEN
Laboratory Animal and Comparative Medicine 2025;45(4):439-448
ObjectiveTo establish background data for a 90-day feeding trial of SD rats to ensure the reliability of research data. MethodsBackground data from six independent 90-day feeding trials of SD rats conducted by the National Center for Safety Evaluation of Drugs from 2020 to 2023 were summarized. These studies involved a blank control group of 120 SPF-grade 4-week-old SD rats, with an equal number of males and females, which were only given standard full-nutrient pelleted rat feed. After the quarantine period, the animals were observed for an additional 90 days, followed by intraperitoneal injection of Zoletil (50 mg/mL) for anesthesia, blood sampling, euthanasia, and necropsy. By analyzing the data from the blank control group, a relevant background database for SD rats was established. ResultsBoth male and female rats exhibited steady weight gain, with a more pronounced increase in male rats. Within 90 days, the average body weight of male and female rats increased to over 500 g and 300 g, respectively. Three weeks later, the average daily food intake of male rats stabilized at approximately 25~28 g per rat, while that of female rats remained stable at approximately 16~19 g per rat. The food utilization rate of all animals gradually decreased from the first week of the experiment. In the white blood cell (WBC) differential count results, significant differences were observed in the counts of WBCs, neutrophils (Neut), lymphocytes (Lymph), and monocytes (Mono) between males and females (P<0.001). However, there were no significant differences in the percentages of neutrophil (%Neut), lymphocyte (%Lymph), and monocyte (%Mono) between the sexes (P>0.05). The average red blood cell count (RBC), hemoglobin concentration (HGB), hematocrit (HCT), platelet count (PLT), prothrombin time (PT), and activated partial thromboplastin time (APTT) were higher in male animals than in female animals (P<0.05). The average values of alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), creatine phosphokinase (CK), lactate dehydrogenase (LDH), glucose (GLU), and triglyceride (TG) in male rats were higher than those in female rats (P<0.05). The urinary pH range for male animals was 5.0 to 8.5, while for female animals it was 6.5 to 9.0. The majority of male animals had a urinary specific gravity lower than 1.020, and the majority of female animals had a urinary specific gravity lower than 1.015. The weights of various organs (excluding the adrenal glands and reproductive organs) in male animals were heavier than those in female animals (P<0.001), while the organ/body weight ratios (excluding the kidneys and reproductive organs) of female animals were higher than those of male animals (P<0.001). ConclusionThis study summarizes the background reference ranges for body weight, food intake, hematology, and serum biochemistry indicators in SPF-grade SD rats in the untreated control group from six 90-day feeding trials conducted by the National Center for Safety Evaluation of Drugs. It provides important reference data for related research. By summarizing the background and spontaneous histopathological changes in rats, this study aids in the standardization and normalization of subsequent research, as well as in the evaluation and analysis of abnormal results.
8.NAD+ metabolism in cardiovascular diseases.
Zhao-Zhi WEN ; Yi-Hang YANG ; Dong LIU ; Chong-Xu SHI
Acta Physiologica Sinica 2025;77(2):345-360
Cardiovascular diseases (CVDs) are the leading cause of death worldwide. Nicotinamide adenine dinucleotide (NAD+) is a central and pleiotropic metabolite involved in multiple cellular energy metabolism, such as cell signaling, DNA repair, protein modifications, and so on. Evidence suggests that NAD+ levels decline with age, obesity, and hypertension, which are all significant CVD risk factors. In addition, the therapeutic elevation of NAD+ levels reduces chronic low-grade inflammation, reactivates autophagy and mitochondrial biogenesis, and enhances antioxidation and metabolism in vascular cells of humans with vascular disorders. In preclinical animal models, NAD+ boosting also extends the health span, prevents metabolic syndrome, and decreases blood pressure. Moreover, NAD+ storage by genetic, pharmacological, or natural dietary NAD+-increasing strategies has recently been shown to be effective in improving the pathophysiology of cardiac and vascular health in different animal models and humans. Here, we discuss NAD+-related mechanisms pivotal for vascular health and summarize recent research on NAD+ and its association with vascular health and disease, including hypertension, atherosclerosis, and coronary artery disease. This review also assesses various NAD+ precursors for their clinical efficacy and the efficiency of NAD+ elevation in the prevention or treatment of major CVDs, potentially guiding new therapeutic strategies.
Humans
;
Cardiovascular Diseases/physiopathology*
;
NAD/metabolism*
;
Animals
;
Hypertension/metabolism*
9.Eccentric treadmill exercise promotes adaptive hypertrophy of gastrocnemius in rats.
Zhi-Qiang DAI ; Yu KE ; Yan ZHAO ; Ying YANG ; Hui-Wen WU ; Hua-Yu SHANG ; Zhi XIA
Acta Physiologica Sinica 2025;77(3):449-464
The present study aimed to investigate the effects of eccentric treadmill exercise on adaptive hypertrophy of skeletal muscle in rats. Thirty-two 3-month-old Sprague Dawley (SD) rats were selected and randomly assigned to one of the four groups based on their body weights: 2-week quiet control group (2C), 2-week downhill running exercise group (2E), 4-week quiet control group (4C), and 4-week downhill running exercise group (4E). The downhill running protocol for rats in the exercise groups involved slope of -16°, running speed of 16 m/min, training duration of 90 min, and 5 training sessions per week. Twenty-four hours after the final session of training, all the four groups of rats underwent an exhaustion treadmill exercise. After resting for 48 h, all the rats were euthanized and their gastrocnemius muscles were harvested for analysis. HE staining was used to measure the cross-sectional area (CSA) and diameter of muscle fibers. Transmission electron microscope was used to observe the ultrastructural changes in muscle fibers. Purithromycin surface labeling translation method was used to measure protein synthesis rate. Immunofluorescence double labeling was used to detect the colocalization levels of lysosomal-associated membrane protein 2 (Lamp2)-leucyl-tRNA synthetase (LARS) and Lamp2-mammalian target of rapamycin (mTOR). Western blot was used to measure the protein expression levels of myosin heavy chain (MHC) IIb and LARS, as well as the phosphorylation levels of mTOR, p70 ribosomal protein S6 kinase (p70S6K), and eukaryotic translation initiation factor 4E binding protein 1 (4E-BP1). The results showed that, compared with the 2C group rats, the 2E group rats showed significant increases in wet weight of gastrocnemius muscle, wet weight/body weight ratio, running distance, running time, pre- and post-exercise blood lactate levels, myofibrillar protein content, colocalization levels of Lamp2-LARS and Lamp2-mTOR, and LARS protein expression. Besides these above changes, compared with the 4C group, the 4E group further exhibited significantly increased fiber CSA, fiber diameter, protein synthesis rate, and phosphorylation levels of mTOR, p70S6K, and 4E-BP1. Compared with the quiet control groups, the exercise groups exhibited ultrastructural damage of rat gastrocnemius muscle, which was more pronounced in the 4E group. These findings suggest that eccentric treadmill exercise may promote mTOR translocation to lysosomal membrane, activating mTOR signaling via up-regulating LARS expression. This, in turn, increases protein synthesis rate through the mTOR-p70S6K-4E-BP1 signaling pathway, promoting protein deposition and inducing adaptive skeletal muscle hypertrophy. Although the ultrastructural changes of skeletal muscle are more pronounced, the relatively long training cycles during short-term exercise periods have a more significant effect on promoting gastrocnemius muscle protein synthesis and adaptive hypertrophy.
Animals
;
Rats, Sprague-Dawley
;
Physical Conditioning, Animal/physiology*
;
Rats
;
Muscle, Skeletal/metabolism*
;
TOR Serine-Threonine Kinases/metabolism*
;
Male
;
Hypertrophy
;
Adaptation, Physiological/physiology*
;
Adaptor Proteins, Signal Transducing/metabolism*
;
Ribosomal Protein S6 Kinases, 70-kDa/metabolism*
;
Intracellular Signaling Peptides and Proteins
10.Carbon footprint accounting of traditional Chinese medicine extracts based on life cycle assessment: a case study of mulberry leaf extract from an enterprise.
Zhi-Min CI ; Jian-Xiang OU ; Qiang YU ; Chuan ZHENG ; Zhao-Qing PEI ; Li-Ping QU ; Ming YANG ; Li HAN ; Ding-Kun ZHANG
China Journal of Chinese Materia Medica 2025;50(1):120-129
Under the background of carbon peaking and carbon neutrality goals, the Ministry of Ecology and Environment, together with 15 national ministries and commissions, has formulated the Implementation Plan on Establishing a Carbon Footprint Management System, and it is urgent for traditional Chinese medicine(TCM) pharmaceutical enterprises to carry out research on carbon footprint accounting methods of related products. Based on the life cycle assessment(LCA) theory, taking mulberry leaf extract produced by a certain enterprise as an example, this study analyzed the carbon footprint of TCM extracts during the life cycle. The results show that for every 1 kg of product produced, the carbon emissions from the stages of raw material acquisition, transportation, and extract production are-20.569, 1.205, and 173.577 kgCO_2eq(CO_2 equivalent), respectively. The carbon footprint of the product is 154.213 kgCO_2eq·kg~(-1). In addition, the carbon emission is the highest in the production stage, in which the consumption of ethanol solvents makes the greatest contribution to the carbon footprint, accounting for 25.71%, more than one-fourth of the total carbon footprint. The second contribution was from the treatment process of TCM residues, accounting for 19.67%, closely followed by wastewater treatment(17.71%), the consumption of hot steam(17.43%), and drinking water(16.90%). The consumption of electric power and packaging materials has a smaller carbon emission of 2.58%. In particular, the carbon emission caused by the consumption of packaging materials is only 0.04%, which is negligible. The results of the study are expected to provide a reference for TCM enterprises to carry out research on the carbon footprint of products, offer ideas for collaborative innovation in reducing pollution and carbon emissions throughout the entire industry chain of TCM, and develop new quality productivity of modern TCM industry based on green and low-carbon manufacturing.
Morus/chemistry*
;
Plant Leaves/chemistry*
;
Carbon Footprint
;
Drugs, Chinese Herbal/chemistry*
;
Plant Extracts/analysis*
;
Medicine, Chinese Traditional

Result Analysis
Print
Save
E-mail