1.Saponins from Panax japonicus ameliorate high-fat diet-induced anxiety by modulating FGF21 resistance.
Yan HUANG ; Bo-Wen YUE ; Yue-Qin HU ; Wei-Li LI ; Dian-Mei YU ; Jie XU ; Jin-E WANG ; Zhi-Yong ZHOU
China Journal of Chinese Materia Medica 2025;50(1):29-41
Anxiety disorder is a highly prevalent psychological illness, and research has shown that obesity is a significant risk factor for its development. This study explored the ameliorative effects and mechanisms of saponins from Panax japonicus(SPJ) on anxiety disorder in mice fed a high-fat diet(HFD). Fifty C57BL/6J mice were randomly divided into normal control diet(NCD) group, HFD group, and low-and high-dose SPJ groups. At week 12, six mice from the HFD group were further divided into a control group(treated with DMSO) and an exogenous fibroblast growth factor 21(FGF21) group(administered rFGF21). The anxiety-like behavior of the mice was assessed using the open field test and elevated plus maze test. Hematoxylin-eosin(HE) staining and oil red O staining were performed to observe pathological changes in the liver and adipose tissue. Glucose metabolism was evaluated through the glucose tolerance test(GTT) and insulin tolerance test(ITT). Western blot analysis was performed to detect the expression of FGF21 and its downstream-related proteins in the liver and cortex, along with the expression of brain-derived neurotrophic factor(BDNF), disks large homolog 4(DLG4), and synaptophysin(SYP) in the cortex. Real-time quantitative fluorescent PCR(qPCR) was used to detect the expression of FGF21 and its receptor genes in the liver and cortex. Immunofluorescence staining was employed to examine the expression of neuronal activator c-Fos, FGF21, and the FGF21 co-receptor β-klotho in the cerebral cortex. The results showed that SPJ significantly improved the frequency of activity in the open arms of the elevated plus maze and the central area of the open field in HFD mice, up-regulated the expression of BDNF, DLG4, and SYP, and effectively alleviated anxiety-like behaviors in HFD mice. Compared with the NCD group, HFD mice exhibited up-regulated expression of FGF21 in the liver and cerebral cortex, while the expression of fibroblast growth factor receptor 1(FGFR1) and β-klotho was significantly down-regulated, suggesting that HFD mice exhibited FGF21 resistance. SPJ markedly up-regulated the β-klotho levels in HFD mice, reversing FGF21 resistance. Further comparison with exogenously administered FGF21 revealed that SPJ activates brain cortical regions in a consistent manner, and additionally, SPJ promotes the number and colocalization of c-Fos and β-klotho positive cells in the brain cortex. In summary, SPJ effectively alleviates anxiety-like behaviors in HFD mice. Its mechanism is associated with up-regulation of β-klotho expression in the brain, reversal of FGF21 resistance, and subsequent activation of neurons in the cerebral cortex and amygdala.
Animals
;
Diet, High-Fat/adverse effects*
;
Fibroblast Growth Factors/genetics*
;
Mice
;
Male
;
Panax/chemistry*
;
Mice, Inbred C57BL
;
Anxiety/etiology*
;
Saponins/administration & dosage*
;
Brain-Derived Neurotrophic Factor/genetics*
;
Humans
;
Liver/metabolism*
;
Drugs, Chinese Herbal/administration & dosage*
2.Global Research of Medical Technology Management: A Bibliometric Analysis.
Liu-Fang WANG ; Yu-Ni HUANG ; Richard Sze-Wei WANG ; Xiao-Ping QIN ; Zhi-Yuan HU ; Bing-Long WANG ; Zhi-Min HU
Chinese Medical Sciences Journal 2025;40(2):120-131
OBJECTIVES:
To explore potential keywords, research clusters, collaborative pattern, and research trends in the field of medical technology management (MTM) through bibliometric analysis, providing insights for researchers, policy makers, and hospital administrators.
METHODS:
A retrieval formula was applied to the title, abstract, and keywords in the Web of Science (WoS) Core Collection, along with system-recommended terms, to identify articles on MTM. A total of 181 articles published between 1974 and 2022 were retained for quantitative analysis. The global trend of research output; total citations, average citations, and H-index; and bibliographic coupling, co-authorship, and keyword co-occurrence were analyzed using VOSviewer.
RESULTS:
The number of articles on MTM has been steadily increasing year by year. The focus of research has shifted from addressing basic medical needs to prioritizing emergency response and medical information security. The United States, Italy, and the United Kingdom emerged as the main contributors, with the United States leading in both volume of publications (60 articles) and academic impact (H-index = 21). Authors from the United Kingdom and the United States led the way in cross-border cooperation. The top five institutions, ranked by total link strength among cross-institutional authors, were primarily located in Canada and Spain.
CONCLUSIONS
The field of MTM has experienced stable growth over the past three decades (1993-2022). The shift of research focus has prompted a heightened emphasis on protecting patient privacy and ensuring the security of medical data. Future research should emphasize interdisciplinary and professional collaboration, as well as international cooperation and open sharing of knowledge.
Bibliometrics
;
Humans
;
Biomedical Technology
3.Acupuncture activates vagus nerve-macrophage axis and improves cardiac electrophysiology and inflammatory response in rats with atrial fibrillation via α7nAChR-JAK2/STAT3 pathway.
Zhi-Han LI ; Wen-Min YANG ; Qi HUANG ; Guang-Xia SHI ; Cun-Zhi LIU ; Yu-Qin ZHANG
Journal of Integrative Medicine 2025;23(4):398-414
OBJECTIVE:
The occurrence and development of atrial fibrillation (AF) are influenced by the autonomic nervous system and inflammation. Acupuncture is an effective treatment for AF. This study explored the protective effects of acupuncture in a rat model of paroxysmal AF and investigated its mechanisms.
METHODS:
Male Sprague-Dawley rats (n = 130) were randomly divided into blank control (Con), sham operation (Sham), AF, and acupuncture treatment (Acu) groups. A paroxysmal AF model was established by rapid atrial pacing through the jugular vein. Rats in the Acu group were immobilized to receive acupuncture treatment at Neiguan acupoint (PC6) for 20 min daily for seven days. The other groups were immobilized for the same duration over the treatment period but did not receive acupuncture. The AF induction rate, AF duration, cardiac electrophysiological parameters, and heart rate variability were evaluated by monitoring surface electrocardiogram and vagus nerve discharge signals. After the intervention, the rats were euthanized, and atrial morphology was assessed using haematoxylin and eosin staining. The expression of macrophage F4/80 antigen (F4/80) and cluster of differentiation (CD) 86 in atrial myocardial tissue was detected using immunohistochemistry, immunofluorescence and flow cytometry. The expression levels or contents of interleukin (IL)-1β, IL-6, tumor necrosis factor-α (TNF-α), α7 nicotinic acetylcholine receptor (α7nAChR), phosphorylated Janus kinase 2 (p-JAK2), and phosphorylated signal transducer and activator of transcription 3 (p-STAT3) in atrial myocardial tissue were detected using Western blotting, reverse transcription-quantitative polymerase chain reaction, or enzyme-linked immunosorbent assay. The role of α7nAChR in acupuncture treatment was verified by intraperitoneal injection of the α7nAChR antagonist methyllycaconitine (MLA).
RESULTS:
Compared with the AF group, acupuncture significantly reduced AF duration and induction rate, improved cardiac electrophysiology by enhancing vagus nerve activity and regulating autonomic balance. It also decreased the pro-inflammatory M1 macrophage proportion, alleviating myocardial injury and infiltration. MLA weakened acupuncture's electrophysiological improvement and anti-inflammatory effect. Results suggest that acupuncture triggers the α7nAChR-JAK2/STAT3 pathway and exerts cardioprotection via neuroimmune regulation.
CONCLUSION
Acupuncture significantly reduced the AF induction rate, shortened AF duration, improved cardiac electrophysiological parameters, enhanced vagus nerve activity, and decreased the expression of pro-inflammatory M1 macrophages and inflammatory factors in rats with paroxysmal AF. Its positive effects are related to the activation of the α7nAChR-mediated JAK2/STAT3 signalling pathway, indicating that the interaction between cardiac vagus nerve and macrophages may be a potential target for acupuncture in the prevention and treatment of AF. Please cite this article as: Li ZH, Yang WM, Huang Q, Shi GX, Liu CZ, Zhang YQ. Acupuncture activates vagus nerve-macrophage axis and improves cardiac electrophysiology and inflammatory response in rats with atrial fibrillation via α7nAChR-JAK2/STAT3 pathway. J Integr Med. 2025; 23(4): 398-414.
Animals
;
Male
;
Rats, Sprague-Dawley
;
STAT3 Transcription Factor/metabolism*
;
alpha7 Nicotinic Acetylcholine Receptor/metabolism*
;
Janus Kinase 2/metabolism*
;
Atrial Fibrillation/metabolism*
;
Vagus Nerve/physiopathology*
;
Rats
;
Acupuncture Therapy
;
Signal Transduction
;
Macrophages/metabolism*
;
Inflammation/therapy*
4.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Heart-sparing strategy for breast cancer radiotherapy based on nnU-Net: regional optimization and automatic segmentation
Jinghan HUANG ; Maidina BATUER ; Chuanghui ZHOU ; Zhi ZHANG ; Limei DENG ; Yuan XU ; Junyuan ZHONG ; Linghong ZHOU ; Xia LI ; Genggeng QIN
Chinese Journal of Radiation Oncology 2025;34(4):355-362
Objective:To investigate the feasibility and optimal expansion width of replacing the left anterior descending coronary artery (LADCA) with the region of heart sparing (RHS) to reduce cardiac radiation dose during breast cancer radiotherapy.Methods:Retrospective analysis was conducted on data from 88 patients with left-sided breast cancer who underwent radiotherapy at 2 centers: Nanfang Hospital of Southern Medical University (50 cases for the training set, 15 cases for the internal test set) and Ganzhou Hospital of Nanfang Hospital (23 cases for the external test set) from March 2022 to January 2024. All patients had left-sided invasive ductal carcinoma with axillary lymph node metastasis, and had undergone modified radical mastectomy and chemotherapy. Based on simulation CT images, 2 radiation oncologists delineated the LADCA and 8 RHSs. The RHSs were delineated by expanding the LADCA contour by 0.5 cm increments, totaling 8 expansions. The RHS widths were defined as 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, and 4.0 cm. The nnU-Net model was trained for 3D automatic segmentation of the LADCA and RHSs. Model performance was evaluated using the Dice similarity coefficient (DSC), relative volume error (RVE), sensitivity, specificity, and 95% Hausdorff distance (HD95). Additionally, the minimum, maximum, and average relative dose variations (RDV) as well as V5% and V20% indicators were calculated for the LADCA and each RHS. Correlation analysis was performed using the least squares regression, with the slope and coefficient of determination ( R2) employed to evaluate the accuracy of the model fitting, the relationship between the LADCA and RHS, and the degree of their correlation, thereby assessing the substitutive effect of the RHS for the LADCA. Results:The DSC for the LADCA was 0.415, while the DSCs for RHS widths of 0.5 cm and 4.0 cm were 0.718 and 0.835, respectively. Overall, the automatic segmentation performance improved with increasing RHS width. The DSC, RVE, sensitivity, specificity, and HD95 for the external test set were largely consistent with those of the internal test set, demonstrating the model's good robustness across different datasets. All RDVmin values were negative, while RDVmax and RDVmean showed a positive correlation with RHS width. RDVmean increased from 39.01% to 75.89% as the RHS width increased. In the correlation analysis, the slopes for RHS widths of 1.5 cm and 2.0 cm were 0.95 and 1.05, respectively, with R2 values and coefficients of variation of 0.79 and 0.73, and 21.11% and 24.03%, respectively. Conclusions:The automatic segmentation model trained on nnU-Net can accurately segment RHSs. Based on geometric and dosimetric indicators, a 1.5 cm-wide RHS is the most suitable substitute for the LADCA, effectively limiting the radiation dose to the LADCA without compromising target dose coverage.

Result Analysis
Print
Save
E-mail