1.Robot-assisted percutaneous coronary intervention: a prospective, multicenter, randomized controlled, non-inferiority clinical trial.
Yi YU ; Zheng CHEN ; Zhi-Jian WANG ; Yue-Ping LI ; Li-Xia YANG ; Jing QI ; Jing XIE ; Tao HUANG ; Dong-Mei SHI ; Yu-Jie ZHOU
Journal of Geriatric Cardiology 2025;22(8):725-735
OBJECTIVE:
To evaluate the safety and effectiveness of robot-assisted percutaneous coronary intervention (R-PCI) compared to traditional manual percutaneous coronary intervention (M-PCI).
METHODS:
This prospective, multicenter, randomized controlled, non-inferior clinical trial enrolled patients with coronary heart disease who met the inclusion criteria and had indications for elective percutaneous coronary intervention. Participants were randomly assigned to either the R-PCI group or the M-PCI group. Primary endpoints were clinical and technical success rates. Clinical success was defined as visually estimated residual post-percutaneous coronary intervention stenosis < 30% with no 30-day major adverse cardiac events. Technical success in the R-PCI group was defined as successful completion of percutaneous coronary intervention using the ETcath200 robot-assisted system, without conversion to M-PCI in the event of a guidewire or balloon/stent catheter that was unable to cross the vessel or was poorly supported by the catheter. Secondary endpoints included total procedure time, percutaneous coronary intervention procedure time, fluoroscopy time, contrast volume, operator radiation exposure, air kerma, and dose-area product.
RESULTS:
The trial enrolled 152 patients (R-PCI: 73 patients, M-PCI: 79 patients). Lesions were predominantly B2/C type (73.6%). Both groups achieved 100% clinical success rate. No major adverse cardiac events occurred during the 30-day follow-up. The R-PCI group had a technical success rate of 100%. The R-PCI group had longer total procedure and fluoroscopy times, but lower operator radiation exposure. The percutaneous coronary intervention procedure time, contrast volume, air kerma, and dose-area product were similar between the two groups.
CONCLUSIONS
For certain complex lesions, performing percutaneous coronary intervention using the ETcath200 robot-assisted system is safe and effective and does not result in conversion to M-PCI.
2.Kaempferol-A Natural Drug for Rheumatoid Arthritis.
Hong-Mei HONG ; Jia-Wang ZHOU ; Ming-Yu LI ; Gui-Feng HAO ; Zhi-Jun XIE
Chinese journal of integrative medicine 2025;31(12):1119-1128
3.Preliminary study on treatment of local digestive tract diseases in children with octreotide injection through"oral administration"
Miao HE ; Yong-Mei XIE ; Zhi-Ling WANG
The Chinese Journal of Clinical Pharmacology 2024;40(5):673-677
Objective To explore the feasibility of octreotide injection for"oral administration"in children.Methods The acid resistance stability experiment was divided into experimental group(dissolve octreotide in hydrochloric acid at pH 4.0-4.5)and control group(dissolve octreotide in 0.9%NaCl at pH 7.0-7.5).BN juvenile rats were randomly assigned to the subcutaneous injection group of octreotide(12 μg·kg-1·d-1,subcutaneous injection),the oral administration group of octreotide(12 μg·kg-1·d1-1,oral administration),and the control group(0.9%NaCl)based on gender and body mass grading,with 10 rats in each group.Collect blood samples from 2 children with refractory diarrhea after subcutaneous injection and oral administration of octreotide for 1 hour,and monitor the plasma concentration.Compare the differences in plasma and gastrointestinal concentrations in rats,as well as the differences in plasma concentration in two pediatric patients.Measure the plasma concentration of octreotide using radioimmunoassay.Detection of octreotide concentration in rat intestine by immunohistochemical method.Results The concentrations of octreotide in the experimental group and control group were(810.71±1.91)and(816.55±5.60)ng·mL-1,respectively,without statistically significant difference(P>0.05).The integrated optical density(IOD)values of octreotide in the subcutaneous injection group and oral administration group were 6.84±0.88 and 9.82±1.07;the concentrations of octreotide in peripheral blood were(26.07±12.19)and(3.53±0.76)ng·mL-1,with statistical significance(all P<0.001).The plasma concentration of octreotide administered orally and subcutaneously in two pediatric patients were 2.52-3.30 and 22.36-31.68 ng·mL-1.Conclusion"Oral administration"of octreotide exhibits a distribution of"high gastrointestinal concentration/low plasma concentration".High gastrointestinal concentration can treat local gastrointestinal diseases in children and avoid injection pain.Oral administration of low plasma concentration is beneficial for reducing systemic adverse drug reactions in children with growth inhibition.
4.Analysis of cyclophosphamide adverse events in clinical applications
Wan-Chun ZHANG ; Mei-Jiao WANG ; Zhi-Jun XIE
The Chinese Journal of Clinical Pharmacology 2024;40(7):1063-1067
Objective To provide clinical practitioners with references for rational and safe usage of cyclophosphamide(CTX)by conducting an in-depth analysis of its adverse drug events(ADE)reported in clinical settings.Methods Based on the Food and Drug Administration(FDA)adverse event reporting system,the online pharmacovigilance tool OpenVigil collected ADE data of CTX from January 1,2013 to March 11,2023.The ADE data mining analysis was performed using the reporting odds ratio(ROR)and Bayesian confidence propagation neural network(BCPNN)methods.Results A total of 8 223 ADE reports met the inclusion criteria,and 422 ADE signals were obtained,involving 21 system organ classification(SOC),of which women(44.12%)accounted for a higher proportion than men(31.02%),the age distribution was mainly in the population 46-65 years old.The involved SOC mainly included infections and invasive diseases,hematologic and lymphatic system diseases,systemic diseases and various reactions at the site of administration,etc.;the ADE signals with a higher number of reports were myelosuppression,disease progression,pyrexia,febrile neutropenia,etc.A total of 18 suspected adverse drug reaction(ADR)not documented in the CTX drug insert were unearthed.Conclusion Clinical practitioners should be alert to ADE signals outside the drug insert,such as neonatal diseases and maternal exposure before pregnancy,methemoglobinemia,etc.,when using cyclophosphamide to improve the safety and effectiveness of clinical treatment.
5.Current applications of transcatheter edge-to-edge tricuspid valve repair
Chun-Mei XIE ; Meng-Qi SHEN ; Da ZHU ; Shou-Zheng WANG ; Zhi-Ling LUO ; Xiang-Bin PAN
Chinese Journal of Interventional Cardiology 2024;32(1):45-50
Tricuspid regurgitation(TR)is a common heart valve disease.According to the pathogenesis,TR can be divided into primary(organic)and secondary(functional)regurgitation,of which functional TR accounts for more than 90%.Patients with severe TR have poor prognosis and poor drug treatment,and surgery(valvuloplasty)is the main treatment.At present,transcatheter edge-to-edge tricuspid valve repair(T-TEER)has become an essential program of transcatheter treatment for TR,providing minimally invasive treatment for TR patients who cannot undergo surgery or are at high risk of surgery.T-TEER reduces the degree of regurgitation by clamping leaflets,and is currently in the early stage of research and development exploration and clinical validation,mainly for functional TR.T-TEER devices have also made significant progress(TriClip,PASCAL),and Chinese-made novel-designed T-TEER devices are also undergoing clinical trials(DragonFly-TTM,SQ-Kyrin-TTM,NeoBlazarTM).This paper reviews the current applications and research progress of T-TEER.
6.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
7.Expert consensus on ethical requirements for artificial intelligence (AI) processing medical data.
Cong LI ; Xiao-Yan ZHANG ; Yun-Hong WU ; Xiao-Lei YANG ; Hua-Rong YU ; Hong-Bo JIN ; Ying-Bo LI ; Zhao-Hui ZHU ; Rui LIU ; Na LIU ; Yi XIE ; Lin-Li LYU ; Xin-Hong ZHU ; Hong TANG ; Hong-Fang LI ; Hong-Li LI ; Xiang-Jun ZENG ; Zai-Xing CHEN ; Xiao-Fang FAN ; Yan WANG ; Zhi-Juan WU ; Zun-Qiu WU ; Ya-Qun GUAN ; Ming-Ming XUE ; Bin LUO ; Ai-Mei WANG ; Xin-Wang YANG ; Ying YING ; Xiu-Hong YANG ; Xin-Zhong HUANG ; Ming-Fei LANG ; Shi-Min CHEN ; Huan-Huan ZHANG ; Zhong ZHANG ; Wu HUANG ; Guo-Biao XU ; Jia-Qi LIU ; Tao SONG ; Jing XIAO ; Yun-Long XIA ; You-Fei GUAN ; Liang ZHU
Acta Physiologica Sinica 2024;76(6):937-942
As artificial intelligence technology rapidly advances, its deployment within the medical sector presents substantial ethical challenges. Consequently, it becomes crucial to create a standardized, transparent, and secure framework for processing medical data. This includes setting the ethical boundaries for medical artificial intelligence and safeguarding both patient rights and data integrity. This consensus governs every facet of medical data handling through artificial intelligence, encompassing data gathering, processing, storage, transmission, utilization, and sharing. Its purpose is to ensure the management of medical data adheres to ethical standards and legal requirements, while safeguarding patient privacy and data security. Concurrently, the principles of compliance with the law, patient privacy respect, patient interest protection, and safety and reliability are underscored. Key issues such as informed consent, data usage, intellectual property protection, conflict of interest, and benefit sharing are examined in depth. The enactment of this expert consensus is intended to foster the profound integration and sustainable advancement of artificial intelligence within the medical domain, while simultaneously ensuring that artificial intelligence adheres strictly to the relevant ethical norms and legal frameworks during the processing of medical data.
Artificial Intelligence/legislation & jurisprudence*
;
Humans
;
Consensus
;
Computer Security/standards*
;
Confidentiality/ethics*
;
Informed Consent/ethics*
8.Comparison on the efficacy of Chinese-made novel-designed mechanical-locked and elastic self-locked transcatheter edge-to-edge repair system in the treatment of patients with functional mitral regurgitation.
Da ZHU ; Shou Zheng WANG ; Zhi Ling LUO ; Jia Hua PAN ; Ke YANG ; Chun Mei XIE ; Yong Yan TANG ; Hong Bo YANG ; Mi Er MA ; Jian Bin GAO ; Xiang Bin PAN
Chinese Journal of Cardiology 2023;51(8):832-837
Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.
Humans
;
Female
;
Middle Aged
;
Aged
;
Male
;
Mitral Valve Insufficiency/etiology*
;
Retrospective Studies
;
East Asian People
;
Heart Valve Prosthesis Implantation
;
Treatment Outcome
;
China
;
Heart Failure/etiology*
;
Cardiac Catheterization
10.Analysis of APTT Mixing Test Results in Factor Ⅷ Inhibitor-Positive Hemophilia Patients.
Li-Hua ZHANG ; Zhi-Qiang XIE ; He ZHUANG ; Mei-Hua WANG ; Ying-Ping CAO
Journal of Experimental Hematology 2023;31(6):1791-1796
OBJECTIVE:
To analyze the results of activated partial thromboplastin time (APTT) mixing test in coagulation factor Ⅷ inhibitor-positive hemophilia patients, so as to increase the value of APTT mixing test in the screen of factor Ⅷ inhibitor.
METHODS:
Eighty plasmas samples with different titers of coagulation factor Ⅷ inhibitors had been collected and diluted for routine immediate APTT mixing test and at 37 ℃ 2 hours incubation APTT mixing test. Fifteen samples were selected for immediate and normal temperature incubation for 15 min, 30min, 1 hour, 2 hours and 37 ℃ for 30 min, 1 hour, 2 hours APTT mixing test.
RESULTS:
The results of APTT mixing test were significantly correlated with the titers of coagulation factor Ⅷ inhibitors. The ROC curve result showed that the best diagnostic cut-off value for 2 hours incubation APTT mixing test at 37 ℃ to determine the presence or absence of coagulation factor Ⅷ inhibitors was 43.8 s (sensitivity and specificity was 85.90% and 100%, respectively), while the best diagnostic cut-off value for distinguishing high-titer and low-titer Ⅷ inhibitors was 52.4 s (sensitivity and specificity was 98.18% and 95.65%, respectively). The critical coagulation factor Ⅷ inhibitor titer that could not be corrected by immediate APTT was 5.14 BU/ml, while that could not be corrected by 37 ℃ 2 hours incubation APTT was 1.31 BU/ml. Paired samples t -test was performed on the APTT mixing test results at different times and temperatures, and the differences were statistically significant (P < 0.05).
CONCLUSIONS
The APTT mixing test can be used as a screening index for coagulation factor Ⅷ inhibitors. APTT mixing test result shows a significant time-temperature dependence with lower titers of coagulation factor Ⅷ inhibitor. Patients with hemophilia who cannot be corrected by immediate APTT mixing test should be alert to the possibility of high titer of coagulation factor Ⅷ.
Humans
;
Factor VIII
;
Hemophilia A/diagnosis*
;
Blood Coagulation Tests/methods*
;
Partial Thromboplastin Time
;
Blood Coagulation Factors

Result Analysis
Print
Save
E-mail