1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures
Xing-Long ZHAO ; Jian-Jun SHEN ; Kang-Hu FENG ; Zhi-Wei CHEN ; Yuan-Long SI ; Xuan ZHANG ; Guan-De WANG ; Xiang HAI
China Journal of Orthopaedics and Traumatology 2024;37(2):129-134
Objective To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures.Methods A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021.Among them,37 patients were treated with F screw internal fixa-tion,including 16 males and 21 females,aged47 to 64years old with an average of(53.87±5.28)years old;According to Pauwels classification,there were 1 case of type Ⅰ,19 cases of type Ⅱ,17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling,8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of(35.00±7.34)hours.Another 35 cases used internal fixation with an inverted triangle parallel nail,including 13 males and 22 females with an average age of 46 to 63 years old(52.36±5.05)years old;According to the Pauwels injury classifi-cation:there were 2 cases of type Ⅰ,21 cases of type Ⅱ,12 cases of type Ⅲ;6 cases of medical diseases,15 cases of falling in-jury,9 cases of traffic accident,11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of(33.00±6.83)h.The intraoperative blood loss,operation time,intraoperative fluoroscopy times,follow-up time,fracture healing time,postoperative complications were observed and compared between the two groups.The hip joint function was e-valuated by Harris score at 6 months and 12 months after operation.Results There was no significant difference in operation time,intraoperative blood loss,intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05).Both groups were followed up regularly,and the follow-up time was 12 to 16 months.The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group(P<0.05).There was 1 case of femoral neck shortening in the F screw internal fixation group,1 case of nonunion,1 case of nail withdrawal,and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group.The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05).Conclusion Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures.It can significantly shorten the fracture healing time,reduce the incidence of postoperative complications,significantly improve hip joint function,and improve the quality of life.
7.Artificial intelligence and radiomics-assisted X-ray in diagnosis of lumbar osteoporotic vertebral compression fractures
Kang-En HAN ; Hong-Wei WANG ; Hong-Wen GU ; Yin HU ; Shi-Lei TANG ; Zhi-Hao ZHANG ; Hai-Long YU
Journal of Regional Anatomy and Operative Surgery 2024;33(7):579-583
Objective To explore the efficiency of artificial intelligence and radiomics-assisted X-ray in diagnosis of lumbar osteoporotic vertebral compression fractures(OVCF).Methods The clinical data of 455 patients diagnosed as lumbar OVCF by MRI in our hospital were selected.The patients were divided into the training group(n=364)and the validation group(n=91),X-ray films were extracted,the image delineation,feature extraction and data analysis were carried out,and the artificial intelligence radiomics deep learning was applied to establish a diagnostic model for OVCF.After verifying the effectiveness of the model by receiver operating characteristic(ROC)curve,area under the curve(AUC),calibration curve,and decision curve analysis(DCA),the efficiencies of manual reading,model reading,and model-assisted manual reading of X-ray in the early diagnosis of OVCF were compared.Results The ROC curve,AUC and calibration curve proved that the model had good discrimination and calibration,and excellent diagnostic performance.DCA demonstrated that the model had a higher clinical net benefit.The diagnostic efficiency of the manual reading group:the accuracy rate was 0.89,the recall rate was 0.62.The diagnostic efficiency of the model reading group:the accuracy rate was 0.93,the recall rate was 0.86,the model diagnosis showed good predictive performance,which was significantly better than the manual reading group.The diagnostic efficiency of the model-assisted manual reading group:the accuracy rate was 0.92,the recall rate was 0.72,and the recall rate of the model-assisted manual reading group was higher than that of the manual reading group,but lower than that of the model reading group,indicating the superiority of the model diagnosis.Conclusion The diagnostic model established based on artificial intelligence and radiomics in this study has reached an ideal level of efficacy,with better diagnostic efficacy compared with manual reading,and can be used to assist X-ray in the early diagnosis of OVCF.
8.Establishment and validation of a prediction model to evaluate the prolonged hospital stay after anterior cervical discectomy and fusion
Hong-Wen GU ; Hong-Wei WANG ; Shi-Lei TANG ; Kang-En HAN ; Zhi-Hao ZHANG ; Yin HU ; Hai-Long YU
Journal of Regional Anatomy and Operative Surgery 2024;33(7):604-609
Objective To develop a clinical prediction model for predicting risk factors for prolonged hospital stay after anterior cervical discectomy and fusion(ACDF).Methods The clinical data of 914 patients underwent ACDF treatment for cervical spondylotic myelopathy(CSM)were retrospectively analyzed.According to the screening criteria,800 eligible patients were eventually included,and the patients were divided into the development cohort(n=560)and the validation cohort(n=240).LASSO regression was used to screen variables,and multivariate Logistic regression analysis was used to establish a prediction model.The prediction model was evaluated from three aspects:differentiation,calibration and clinical effectiveness.The performance of the model was evaluated by area under the curve(AUC)and Hosmer-Lemeshow test.Decision curve analysis(DCA)was used to evaluate the clinical effectiveness of the model.Results In this study,the five factors that were significantly associated with prolonged hospital stay were male,abnormal BMI,mild-to-moderate anemia,stage of surgery(morning,afternoon,evening),and alcohol consumption history.The AUC of the development cohort was 0.778(95%CI:0.740 to 0.816),with a cutoff value of 0.337,and that of the validation cohort was 0.748(95%CI:0.687 to 0.809),with a cutoff value of 0.169,indicating that the prediction model had good differentiation.At the same time,the Hosmer-Lemeshow test showed that the model had a good calibration degree,and the DCA proved that it was effective in clinical application.Conclusion The prediction model established in this study has excellent comprehensive performance,which can better predict the risk of prolonged hospital stay,and can guide clinical intervention as soon as possible,so as to minimize the postoperative hospital stay and reduce the cost of hospitalization.
9.Risk factors for surgical site infection after transforaminal lumbar interbody fusion in treatment of lumbar degenerative diseases
Kang-En HAN ; Hong-Wei WANG ; Hong-Wen GU ; Yin HU ; Shi-Lei TANG ; Zhi-Hao ZHANG ; Hai-Long YU
Journal of Regional Anatomy and Operative Surgery 2024;33(9):810-814
Objective To explore the risk factors for surgical site infection(SSI)after transforaminal lumbar interbody fusion(TLIF)for the treatment of lumbar degenerative diseases.Methods A total of 1 000 patients who underwent TLIF for lumbar degenerative diseases in our hospital were included and divided into the infection group(n=23)and the non-infection group(n=977)according to whether the surgical incision was infected.General data,surgical and laboratory indicators of patients were collected,and potential risk factors of SSI were screened by univariate analysis and multivariate regression analysis,a nomogram model was established,and its predictive efficiency was validated by the receive operating characteristic(ROC)curve.Results The incidence of SSI in patients after TLIF was 2.3%.The results of univariate analysis showed that age,operative time,intraoperative blood loss,preoperative C-reactive protein(CRP),smoking,and diabetes mellitus were the significant risk factors for the occurrence of SSI.Multivariate regression analysis showed that older age,longer operation time,more intraoperative blood loss,smoking and diabetes mellitus were the independent risk factors for postoperative SSI.ROC curve showed that the nomogram model established in this study has good predictive efficiency.Conclusion Older age,longer operation time,more intraoperative blood loss,smoking,and diabetes mellitus were independent risk factors for postoperative SSI.For patients with these high risk factors,corresponding intervention measures should be taken before operation to reduce the incidence of SSI.
10.Prediction and identification of B-cell epitopes of SARS-CoV-2 E protein
Peng-Fei ZHANG ; Jun LIU ; Zi-Yang ZOU ; Xi-Long KANG ; Li SONG ; Xin-An JIAO ; Chuang MENG ; Zhi-Ming PAN
Chinese Journal of Zoonoses 2024;40(9):807-813
This work was aimed at predicting and verifying B-cell epitopes of SARS-CoV-2 E protein through bioinformatics methods,and clarifying the dominant B cell epitopes with mouse polyclonal antibody serum prepared through SARS-CoV-2 re-combinant E protein immunization and human positive serum vaccinated with inactivated SARS-CoV-2 vaccine.The structural and B-cell linear epitopes of SARS-CoV-2 E protein were predicted with SOPMA,Expasy,SWISS-MODEL,IEDB database,and Bepid-2.0 software.Candidate epitopes were expressed as GST-tagged recombinant protein fragments in an E.coli sys-tem,and their immunoreactivity with mouse and human poly-clonal positive serum against SARS-CoV-2 E protein was de-tected by western blotting and indirect ELISA,respectively.The epitope prediction results showed that E protein contained linear B cell epitopes Ser6-Val14 and Tyr57-Pro71,and the conformational epitopes of Glu8-Val12,Leu39-Tyr59,and Ser60-Leu65.The GST tagged recombinant E protein fragments of E1 and E3,containing Ser6-Val14 and Tyr57-Pro71 epitopes,respectively,as well as E2 without an epitope sequence as a control,were expressed in an E.coli expression system and successfully purified with an Ni-NTA column.Western blotting and indirect ELISA analysis indicated that all mouse and human SARS-CoV-2 positive sera positively reacted with only E1 and E3 proteins,but negatively reacted with E2 protein,thus indicating that the corresponding epitope prediction with Ser6-Val14 and Tyr57-Pro71 was correct.This study successfully predicted and preliminarily identified two linear B cell epitopes of SARS-CoV-2 E protein,thus providing a reference for the preparation of new coronavirus vaccines and the analysis of immune response characteristics.

Result Analysis
Print
Save