1.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
2.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Strategy for cysteine-targeting covalent inhibitors screening using in-house database based LC-MS/MS and drug repurposing
Xiaolan HU ; Jian-Lin WU ; Quan HE ; Zhi-Qi XIONG ; Na LI
Journal of Pharmaceutical Analysis 2025;15(3):637-650
Targeted covalent inhibitors,primarily targeting cysteine residues,have attracted great attention as potential drug candidates due to good potency and prolonged duration of action.However,their dis-covery is challenging.In this research,a database-assisted liquid chromatography-tandem mass spec-trometry(LC-MS/MS)strategy was developed to quickly discover potential cysteine-targeting compounds.First,compounds with potential reactive groups were selected and incubated with N-acetyl-cysteine in microsomes.And the precursor ions of possible cysteine-adducts were predicted based on covalent binding mechanisms to establish in-house database.Second,substrate-independent product ions produced from N-acetyl-cysteine moiety were selected.Third,multiple reaction monitoring scan was conducted to achieve sensitive screening for cysteine-targeting compounds.This strategy showed broad applicability,and covalent compounds with diverse structures were screened out,offering structural resources for covalent inhibitors development.Moreover,the screened compounds,norket-amine and hydroxynorketamine,could modify synaptic transmission-related proteins in vivo,indicating their potential as covalent inhibitors.This experimental-based screening strategy provides a quick and reliable guidance for the design and discovery of covalent inhibitors.
5.Relationship between radial-ulnar ratio,lateral lunate angle of radius and height loss of radius after palmar locking plate surgery for distal radius fractures
Xing-jun LI ; Jun-jun SUN ; Bo ZHENG ; Jun ZHANG ; Zhi-fei JIAN ; Xiang ZHUO
Journal of Regional Anatomy and Operative Surgery 2025;34(6):505-511
Objective To investigate the relationship between the radial-ulnar ratio,lateral lunate angle of radius and height loss of radius after palmar locking plate internal fixation for distal radius fractures.Methods A total of 158 patients with distal radius fractures treated with palmar locking plate internal fixation in our hospital from March 2020 to September 2023 were selected.According to the height of radius loss after operation,the patients were divided into non-radius loss group(41 cases,<2 mm),mild to moderate radius loss group(32 cases,2 to 5 mm)and severe radius loss group(85 cases,>5 mm),and the clinical data of patients in the three groups were compared.Multivariate Logistic regression analysis was used to analyze the risk factors affecting height loss of radius.Locally weighted scatterplot smoothing(LOWESS)method was used to analyze the two-dimensional curve relationship of continuous variables.Restricted cubic spline(RCS)and threshold effect were used to analyze the relationship between the radial-ulnar ratio,lateral lunate angle of radius and height loss of radius after operation.Results The age of patients in the severe radius loss group was significantly higher than those in the non-radius loss group and the mild to moderate radius loss group(P<0.05),and the age of patients in the mild to moderate radius loss group was significantly higher than that in the non-radius loss group(P<0.05).Female patients and patients with osteoporosis and fracture type C were more likely to have height loss of radius(P<0.05).There were significant differences in patient-rated wrist evaluation(PRWE)score,disabilities of the arm,shoulder and hand(DASH)score,dorsal extension,palmar curvature,ulnar deviation,radial deviation,radial-ulnar ratio,and lateral lunate angle of radius of patients at 3 and 6 months after operation among three groups(P<0.001).The first prediction model based on age,gender,osteoporosis,fracture type,PRWE score,DASH score,dorsal extension,palmar curvature,ulnar deviation,and radial deviation and the second prediction model based on age,gender,osteoporosis,fracture type,PRWE score,DASH score,dorsal extension,palmar curvature,ulnar deviation,radial deviation,radial-ulnar ratio,and lateral lunate angle of radius were subjected to Hosmer-Lemeshow test showed good goodness of fit.LOWESS analysis showed that age,PRWE score,DASH score,dorsal extension,palmar curvature,ulnar deviation,radial deviation,radial-ulnar ratio,and lateral lunate angle of radius had a certain nonlinear relationship with the height loss of radius.RCS and threshold effect analysis showed that the probability of postoperative radius loss increased with the increase of radial-ulnar ratio in patients with distal radius fractures and radial-ulnar ratio≥13.254(P<0.001).The probability of postoperative radius loss decreased with the increase of the lateral lunate angle of radius in patients with distal radius fractures and lateral lunate angle of radius≤11.068°(P<0.001).Conclusion There was a positive correlation between the radial-ulnar ratio and the height loss of radius,and a negative correlation between the lateral lunate angle of radius and the height loss of radius after palmar locking plate internal fixation for distal radius fractures.
6.Expression characteristics and diagnostic value of PD-1 and PD-L1 in patients with acute exacerbation of chronic obstructive pulmonary disease
Yuexin SHI ; Li LI ; Jun YAN ; Caijun WU ; Zhi YAO ; Yuan-zhen JIAN ; Ziqing LI ; Fang LI ; Lulu YANG
The Journal of Practical Medicine 2025;41(11):1655-1662
Objective To investigate the expression characteristics and clinical diagnostic value of programmed death receptor 1(PD-1)and its corresponding ligand(PD-L1)in patients with acute exacerbation of chronic obstructive pulmonary disease(AECOPD).Methods One hundred and sixty COPD patients who visited Dongzhimen Hospital of Beijing University of Chinese Medicine from April 2024 to November 2024 were included and divided into an acute exacerbation group of 100 cases and a stable group of 60 cases according to the severity of the disease.Additionally,40 healthy volunteers during the same period were recruited as the control group.The general clinical data of the patients were collected.Chronic Obstructive Pulmonary Disease Assessment Test(CAT)and Modified Medical Research Council Dyspnea Questionnaire(mMRC)Scale were used to test the severity of the disease;respiratory function testing was performed and fasting venous blood was collected for serum PD-1 and PD-L1 testing.Pearson correlation was used to analyze the correlation between serum PD-1,PD-L1,CAT,and mMRC,and multiple logistic regression analysis to identify the influencing factors of AECOPD.Receiver operating characteristic(ROC)curve was drawn to evaluate the diagnostic value of serum PD-1 and PD-L1 level for AECOPD.Results Serum PD-1 level in the stable COPD group and AECOPD group was significantly increased compared with that in the control group,while serum PD-L1 level was significantly decreased,showing statistical significance(P<0.05);The level of PD-1 gradually increased with the grading of lung function and the deterioration of AECOPD,with statistical significance(P<0.05);Pearson correlation showed that serum PD-1 level was positively correlated with CAT scores in COPD patients,while negatively with CAT scores,showing statistical significance(P<0.05);Multiple logistic regression analysis showed that elevated levels of serum inter-leukin-6(IL-6),neutrophil to lymphocyte ratio(NLR),and PD-1 were risk factors for AECOPD,while elevated level of PD-L1 was protective factor for AECOPD(P<0.05);ROC curve showed that the levels of PD-1,PD-L1,IL-6,NLR,and the area under the ROC curve(AUC)for their combined prediction of AECOPD diagnosis were 0.884,0.867,0.868,0.802,and 0.995,respectively.Conclusion Serum PD-1 and PD-L1 in AECOPD patients have presented certain expression characteristics,with elevated PD-1 level while decreased PD-L1 level.Both have good clinical diagnostic value for AECOPD.
7.Regulation of white adipose tissue in mice by immunization with recombinant Bacillus Calmette-Gue?rin with c-di-AMP adjuvant
Meng-juan DONG ; Yu-xiao CHANG ; Huan-huan NING ; Yan-zhi LU ; Jian KANG ; Ming-ze XU ; Ting DAI ; Jia-ling LI ; Le-ran HAO ; Lin-na ZHANG ; Yin-lan BAI
Chinese Journal of Zoonoses 2025;41(4):370-375
This study assessed the role and mechanism of the recombinant Bacillus Calmette-Gue?rin vaccine(rBCG)with c-di-AMP adjuvant in regulating metabolism and immunity in epididymal white adipose(eWAT)in mice.Male C57BL/6 mice were intravenously immunized with BCG and rBCG,and their body weights were monitored.eWAT was isolated from the mice,and the stromal vascular fractions(SVFs)cell number was counted with a hemocytometer.Sections of mouse adipose tissue were prepared,and the size,number,and morphology of eWAT adipocytes and crown-like structure(CLS)formation were compared under a microscope after HE staining.The transcription levels of lipid metabolism-associated factors,cytokines and aging-associated genes in each group were determined with qRT-PCR.The body weights of mice gradually increased after immunization with BCG and rBCG.The proportions of eWAT increased,and the SVFs cell number decreased,in rBCG immunized mice.HE staining indicated that BCG immunization promoted hyperplasia,whereas rBCG immunization promoted hypertrophy of eWAT adipocytes;moreover,both BCG and rBCG immunization induced CLS formation in eWAT.The qRT-PCR results indicated that rBCG immunization inhibited the expression of genes associated with lipolysis and energy expenditure in eWAT.BCG immunization had little effect on cytokine transcription,whereas rBCG significantly induced the transcription of IFN-γ and IL-1Ra,and inhibited that of IL-15 and IL-2,but did not induce the expression of aging-associated genes.Thus,rBCG immunization induced eWAT adipocyte hypertrophy,which was associated with the inhibition of eWAT lipolysis and the regulation of cytokine expression.
8.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
9.The value of total volume response and total mass response in the therapeutic evaluation of lung metastasis of hepatocarcinoma
Jun-cheng WAN ; Cai-hong YU ; Chang-yu LI ; Yong-jie ZHOU ; Wei ZHANG ; Jian-hua WANG ; Zhi-ping YAN ; Guo-wei YANG ; Zhuo-yang FAN ; Xu-dong QU
Fudan University Journal of Medical Sciences 2025;52(2):201-208,231
Objective To analyze the correlation between lesion volume,lesion mass,and maximum lesion diameter in the assessment of advanced hepatocarcinoma with lung metastasis,and to evaluate the application value of total volume response and total mass response of lung metastatic lesions in efficacy assessment.Methods A retrospective analysis was conducted on the CT imaging data of 20 patients clinically confirmed with hepatocarcinoma and lung metastases,followed by subsequent follow-up to monitor their survival outcomes.Volume measurement software was used to measure the volume of lesions before and after treatment.We recored lesion diameter,volume measurements and CT values,calculated the mass of the lesions.The correlation between lesion volume,mass and diameter was analyzed,as well as the correlation between the change rates of volume,mass and lesion diameter.Additionally,the total volume and total mass of all lesions were calculated.The correlation between the change rates of total volume/total mass and the change rate of pulmonary lesion diameter under the RECIST 1.1 criteria,as well as the correlation with changes in patients'tumor markers,were analyzed.Furthermore,the overall volume response and overall mass response of lesions were evaluated based on changes in total volume and total mass,and their consistencies with the RECIST 1.1 criteria for efficacy evaluation were analyzed.Finally,univariate Cox regression analysis was performed to explore the association between these variables and patient survival outcomes.Results There was strong correlation between lesion volume,mass and tumor diameter(r=0.771,0.775),between the rate of change in mass and the rate of change in lesion diameter(r=0.846),and between the rates of change in total volume/total mass and the rate of change in pulmonary lesion diameter under the RECIST 1.1 criteria(r=0.800,0.896).The correlation between the rates of change in total volume/total mass and patients'tumor markers was not statistically significant.There was moderate correlation between the rate of change in volume and the rate of change in lesion diameter(r=0.692).The evaluation results of total volume response and total mass response for pulmonary lesions in advanced hepatocarcinoma with lung metastasis were generally consistent with the RECIST 1.1 criteria(Kappa=0.486,0.426).Univariate Cox regression analysis revealed that total lesion volume(P=0.047)and total lesion mass(P=0.049)were independent prognostic factors for survival outcomes.Conclusion Lesion volume,mass,and diameter,as well as their respective change rates,were found to be interrelated.Furthermore,total lesion volume and total lesion mass were identified as independent prognostic factors for survival outcomes.The total volume response and total mass response are promising evaluation methods in evaluating the efficacy of lung metastasis of hepatocarcinoma,which are different from the RECIST 1.1 evaluation criteria.
10.Long-term follow-up of percutaneous pulmonary valve implantation using domestic self-expanding valve-prospective single-center experience
Qian-bei HE ; Qiao LI ; Yi-jian LI ; Rui-tao LI ; Bo-feng CHAI ; Zhi-cheng CHEN ; Zhi-xiang YU ; Zhen-gang ZHAO ; Yuan FENG
Chinese Journal of Interventional Cardiology 2025;33(5):241-248
Objective To explore the long-term efficacy of percutaneous pulmonary valve implantation(PPVI)and the durability of the domestic self-expanding Venus P valve.Methods A total of 8 patients with post-surgical right ventricular outflow tract(RVOT)dysfunction,who were admitted to hospital from October 2014 to July 2016 and deemed anatomically suitable for PPVI with self-expanding valve,were included prospectively.Clinical,imaging,procedural and follow-up data were analyzed.The survival rates,perioperative and long-term complication rates,long-term efficacy of PPVI,and long-term function of Venus P in 8 patients were evaluated.The immediate procedural results were evaluated by clinical implant success rate,which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation<moderate and peak trans-pulmonary pressure gradient<40 mmHg.Results A total of 8 patients were included,with 7 females,aged 14 to 36 years.The initial diagnosis included post-surgical Tetralogy of Fallot(5 cases),post-surgical Trilogy of Fallot(1 case),post-surgical Quadricuspid pulmonary valve stenosis(1 case)and post-surgical Double-Outlet Right Ventricle(1 case).The indications of PPVI included RVOT-pulmonary obstruction and regurgitation(1 case)and isolated regurgitation(7 cases).Clinical implant success was achieved in all of the 8 patients with firmly fixed valve,and there were no such complications as valve detachment,displacement or stent fracture.All patients experienced significant symptom relief after the procedure.The right ventricular end-diastolic volume index(RVEDVi)measured by CMR 6 months after PPVI showed a significant decrease compared to preprocedural values[(89.99±13.85)ml/m2 vs.(144.93±11.28)ml/m2,P=0.001].Postoperative pulmonary regurgitation were significantly improved or disappeared in all patients,and there was no statistically significant difference in the average peak pressure gradient measured by echocardiogram between preoperative and the latest follow-up[(23.25±8.39)mmHg vs.(18.75±6.28)mmHg,P=0.210].Over an average follow-up period of(9.25±0.71)years,1 case of infective endocarditis occurred 5 years after PPVI.During the follow-up,no death,deterioration of heart failure,malignant arrhythmia or other serious complications were observed.All patients completed 8-year follow-up,and 3 completed 10-year follow-up.All patients were graded as NYHA functional class one at the latest follow-up.Conclusions PPVI using the domestically produced self-expanding Venus P is safe and feasible for the treatment of patients with post-surgical RVOT dysfunction and suitable anatomy.Our study confirms the long-term efficacy and durability of Venus P from multiple perspectives,and no severe stent fracture occurred without pre-stent implantation in the native RVOT.

Result Analysis
Print
Save
E-mail