1.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Establishment and evaluation of a lipopolysaccharide-induced acute respiratory distress syndrome model in minipigs
Chuang-Ye WANG ; Ran WANG ; Jian ZHANG ; Ling-Xiao QIU ; Bin QING ; Heng YOU ; Jin-Cheng LIU ; Bin WANG ; Nan-Bo WANG ; Jia-Yu LI ; Xing LIU ; Shuang WANG ; Jin HU ; Jian WEN ; Quan LI ; Xiao-Ou HUANG ; Kun ZHAO ; Shuang-Lin LIU ; Gang LIU ; Mei-Ju WANG ; Qing XIANG ; Hong-Mei WU ; Xiao-Rong SUN ; Tao GU ; Dong ZHANG ; Qi LI ; Zhi XU
Medical Journal of Chinese People's Liberation Army 2025;50(9):1154-1161
Objective To establish a stable,reliable,and clinically relevant porcine model of endotoxin-induced acute respiratory distress syndrome(ARDS).Methods Ten 8-month-old male Bama minipigs were deeply sedated,followed by invasive mechanical ventilation and electrocardiographic monitoring.Lipopolysaccharide(LPS)was intravenously pumped at 600 μg/(kg·h)for 3 hours,then maintained at 15 μg/(kg·h)thereafter.Dynamic monitoring was performed at five time points after LPS injection(LPS 0,1,3,5,and 8 h),including arterial blood gas analysis and chest computed tomography(CT)scans.Pathological examination of lung tissues obtained via bronchoscopic biopsy(HE staining and transmission electron microscopy)was conducted.These indicators were comprehensively used to evaluate the success of the animal model.Results At 5 hours after LPS administration,8 minipigs developed symptoms such as skin cyanosis,elevated body temperature,and respiratory distress.The oxygenation index decreased to<300 mmHg.Chest CT scans showed diffuse pulmonary infiltrates.Histopathology revealed alveolar edema and hyaline membrane formation.Transmission electron microscopy demonstrated disruption of pulmonary blood-air barrier,depletion of lamellar bodies in type Ⅱ pneumocytes,inflammatory cell infiltration,and exudation of plasma proteins and fibrin.Compared with LPS 0 h,at LPS 8 h,the oxygenation index and arterial blood pH were significantly decreased(P<0.001),while blood lactic acid and serum potassium were significantly increased(P<0.05);serum calcium and base excess were significantly decreased(P<0.05),and the lung injury score based on HE-stained lung sections was significantly increased(P<0.01).Conclusion The porcine ARDS model established by continuous LPS injection can dynamically simulate the pathophysiological characteristics and typical pathological manifestations of clinical septic ARDS,making it an effective tool to study the pathogenesis,prevention,and treatment strategies of septic ARDS.
7.AI-Ready Competency Framework for Biomedical Scientific Data Literacy.
Zhe WANG ; Zhi-Gang WANG ; Wen-Ya ZHAO ; Wei ZHOU ; Sheng-Fa ZHANG ; Xiao-Lin YANG
Chinese Medical Sciences Journal 2025;40(3):203-210
With the rise of data-intensive research, data literacy has become a critical capability for improving scientific data quality and achieving artificial intelligence (AI) readiness. In the biomedical domain, data are characterized by high complexity and privacy sensitivity, calling for robust and systematic data management skills. This paper reviews current trends in scientific data governance and the evolving policy landscape, highlighting persistent challenges such as inconsistent standards, semantic misalignment, and limited awareness of compliance. These issues are largely rooted in the lack of structured training and practical support for researchers. In response, this study builds on existing data literacy frameworks and integrates the specific demands of biomedical research to propose a comprehensive, lifecycle-oriented data literacy competency model with an emphasis on ethics and regulatory awareness. Furthermore, it outlines a tiered training strategy tailored to different research stages-undergraduate, graduate, and professional, offering theoretical foundations and practical pathways for universities and research institutions to advance data literacy education.
Artificial Intelligence
;
Humans
;
Biomedical Research
8.Recommendations for the clinical use of anti-amyloid-β monoclonal antibody for Alzheimer's disease(2025)
Nan ZHI ; Jinwen XIAO ; Rujing REN ; Binyin LI ; Jintao WANG ; Jieli GENG ; Wenwei CAO ; Yaying SONG ; Hualong WANG ; Shuguang CHU ; Guoping PENG ; Jun LIU ; Xiaoyun LIU ; Fang YUAN ; Wen WANG ; Ronghua DOU ; Xia LI ; Ling YUE ; Wenshi WEI ; Xiaoling PAN ; Xiangyang ZHU ; Dian HE ; Weinü FAN ; Jingping SHI ; Nan ZHANG ; Hui ZHAO ; Qin CHEN ; Cuibai WEI ; Xiaochun CHEN ; Gang WANG
Journal of Chongqing Medical University 2025;50(9):1133-1140
In recent years,significant breakthroughs have been achieved in the immunotherapy for Alzheimer's disease.In line with global advancements,two anti-amyloid-β monoclonal antibodies have been approved and successfully launched in China for clinical use.Lecanemab and Donanemab were officially used in June 2024 and April 2025 in China,respectively.In order to standardize the rational and safe application of anti-amyloid-β monoclonal antibodies for Alzheimer's disease in China,this article integrates recom-mendations from the clinical trials and real-world experience from the author's team and domestic peers to further update the recom-mendations for the clinical use of anti-amyloid-β monoclonal antibody based on the 2024 version.It includes indications for therapy,pre-treatment evaluation and preparation,administration protocols and safety measures during treatment,and post-treatment monitor-ing strategies.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Design of electric ice blanket system for early treatment of heat stroke disease
Bo-wen YAN ; Yan-yi LU ; Lin ZENG ; Zhi-gang ZHANG ; Nan XIAO ; Qing-hua HE
Chinese Medical Equipment Journal 2025;46(9):16-21
Objective To design an electric ice blanket system for prehospital emergency care of patients of heat sroke disease.Methods The electric ice blanket system consisted of a cooling host and cooling accessories.The cooling host had its chassis made of acrylonitrile-butadiene-styrene(ABS),which was equipped externally with an lithium battery and a DC power adapter,and integrated internally a cooling system,an internal circulation pump,an external circulation pump and a main control system;the cooling accessories included a cooling blanket,a cooling cap and a cooling vest,which had the inner layer made of thermoplastic polyurethane(TPU)elastomer and the outer layer made of Oxford cloth or polyester fiber.The system was compared with the existing subcooling therapeutic apparatus on the market in terms of cooling effect with a water bag simulation cooling experiment.Results The cooling experiment showed that the system was comparable to the existing subcooling therapeutic apparatus on the market in terms of cooling effect while behaved well in size and weight.Conclusion The system developed has a high cooling effect and advantages in portability and compatibility to the environment without power supply,which can be used for the early treatment of patients of heat stroke disease.[Chinese Medical Equipment Journal,2025,46(9):16-21]


Result Analysis
Print
Save
E-mail