1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Au/Three-dimensional Graphene Hydrogel Modified Graphene Electrochemical Transistor for Highly Sensitive Detection of Dopamine
Ru-Ling WANG ; Zhi-Wei CAI ; Jun-Zi PAN ; Ru-Nan TAN ; Yun-Bin HE ; Gang CHANG
Chinese Journal of Analytical Chemistry 2024;52(9):1307-1315,中插5-中插10
Three-dimensional graphene hydrogel(3DGH)was successfully prepared through a hydrothermal method,followed by its composition with gold nanoparticles(AuNPs)to construct a highly sensitive Au/3DGH graphene electrochemical transistor(GECT)dopamine(DA)sensor.AuNPs are efficient electrocatalytic materials.However,their tendency to aggregate during electrodeposition hinds the practical application.The porous and interconnected network structure of 3DGH provided abundant attachment sites,effectively preventing AuNPs aggregation.By modifying the sensor's gate with Au/3DGH,the excellent electrocatalytic performance of Au/3DGH towards DA and the high sensitivity of GECT were utilized to achieve highly sensitive detection of DA.The sensor exhibited a low detection limit of 20 nmol/L and a linear range of 20 nmol/L to 2.5 mmol/L.Remarkably,the sensor showed high sensitivity,excellent selectivity and strong stability,and hold great potnetial in highly sensitive portable detection of DA in disease prevention and clinical monitoring.
7.Effects of Differential First-Line Antiretroviral Therapy (ART) Regimens on Mortality among HIV/AIDS Children in Southwest China: A 15-year Retrospective Cohort Study.
Qiu Li CHEN ; Yan Yan LIAO ; Shan Fang QIN ; Chun Yan LU ; Pei Jiang PAN ; Hai Long WANG ; Jun Jun JIANG ; Zhi Gang ZHENG ; Feng Xiang QIN ; Wen HONG ; Chuan Yi NING ; Li YE ; Hao LIANG
Biomedical and Environmental Sciences 2023;36(11):1079-1083
8.Efficacy of transcatheter pulmonary valve perforation in neonates with pulmonary atresia with intact ventricular septum.
Si Bao WANG ; Si Lin PAN ; Gang LUO ; Zhi Xian JI ; Ai LIU ; Yue Yi REN
Chinese Journal of Pediatrics 2023;61(2):126-130
Objective: To explore the efficacy and safety of transcatheter pulmonary valve perforation in the treatment of neonatal pulmonary atresia with intact ventricular septum (PA-IVS). Methods: The clinical data on surgical treatment and follow-up in 16 patients with PA-IVS who underwent transcatheter pulmonary valve perforation in Women and Children's Hospital, Qingdao University from October 2018 to October 2021 were analyzed retrospectively. The right ventricular systolic pressure and percutaneous oxygen saturation (SpO2) were compared before and after operation. In addition, the SpO2 and echocardiographic data at preoperative and the last follow-up were compared. Comparisons between groups were performed using paired-samples t test. Results: Among the 16 patients (10 males and 6 females) with the age at operation of 19 (14, 26) days, 12 cases underwent transcatheter pulmonary valve perforation successfully, 2 cases were transferred to surgery department for open-heart pulmonary valvulotomy, and the remaining 2 cases were transmitted to surgery department for transthoracic pulmonary valve perforation. The age at operation of the 12 patients who underwent transcatheter pulmonary valve perforation was 18 (14, 27) days, and the weight was (3.6±0.4) kg. The immediate postoperative right ventricular systolic pressure decreased significantly ((57±16) vs. (95±19) mmHg (1 mmHg=0.133 kPa), t=7.49, P<0.001), and the postoperative SpO2 was improved effectively (0.90±0.48 vs.0.75±0.09, t=-5.61, P<0.001). The follow-up time was 22 (7, 33) months for 12 patients who underwent transcatheter pulmonary valve perforation successfully. At the last follow-up, the ratio of right to left ventricular transverse diameter was significantly higher than that before operative (0.55±0.05 vs. 0.45±0.05, t=-3.27,P=0.007). Furthermore, the Z-scores of pulmonary valvular diameter (-0.78±0.23 vs. -1.73±0.56, t=-8.52, P<0.001) and the tricuspid valvular diameter (-0.52±0.12 vs. -1.46±0.38, t=-10.40, P<0.001) were all significantly higher than preoperative data. At last, all the patients achieved biventricular circulation without death or major complications. Conclusion: Transcatheter pulmonary valve perforation is a safe and effective therapy for neonatal PA-IVS, and its curative effect has been confirmed by the medium follow-up data.
Child
;
Male
;
Infant, Newborn
;
Humans
;
Female
;
Pulmonary Valve/surgery*
;
Retrospective Studies
;
Pulmonary Atresia/surgery*
;
Heart Defects, Congenital
9.Spatial epidemiological analysis of severe hand, foot and mouth disease in Guangxi, 2014-2018
PENG Yuan-jun ; HE Wei-tao ; ZHENG Zhi-gang ; PAN Pei-jiang ; JU Yu ; LU Zhen-wei ; LIAO Yan-yan
China Tropical Medicine 2023;23(5):473-
Abstract: Objective To explore the spatial epidemiological characteristics of severe cases hand, foot and mouth disease (HFMD) in Guangxi, China, from 2014 to 2018, and to provide a basis for identifying the high-risk regions as well as the prevention and control of severe cases of HFMD in Guangxi. Methods Spatial-temporal scanning analysis, global and local spatial autocorrelation analysis were used to analyze the spatial clustering of HFMD. The trend surface analysis was used to evaluate the spatial distribution trend of HFMD. Results From 2014 to 2018, the incidence and severe case fatality rates of HFMD were 3.89/100 000 and 4.23%, respectively. Monte Carlo scanning analysis showed that the first cluster region was Cenxi City, the second cluster was mainly concentrated in northwest of Guangxi, and the aggregation time was mainly concentrated in April to May and August to October. The global spatial autocorrelation analysis showed that the severe HFMD was significant clustering distribution, and the Moran's I coefficients of the sever cases, severe morbidity and severe case fatality rate were 0.088, 0.118, 0.197, respectively (P<0.05). Local spatial autocorrelation analysis showed that hotspots of severe HFMD cases were concentrated in the southern Guangxi, mainly in Lingshan County. Anselin local Moran's I clustering and outlier analysis indicated that 5 high-high (H-H) clustering regions for fatality were Lingshan, Pubei, Zhongshan, Zhaoping and Pinggui County. There were 6 high-high (H-H) clustering regions for severe incidence rate, namely Lingshan, Qinnan, Lingyun, Youjiang, Bama Yao Autonomous and Pinggui County, and 1 high-low (H-L) clustering region, Cenxi County. The trend surface analysis showed that the overall number of severe cases of death decreased from east or west to the middle, and increased from north to middle, and then decreased to south. Conclusions Severe HFMD cases in Guangxi have obvious spatial-temporal clustering, and the hop spots are mainly concentrated in southern Guangxi. The prevention and control of HFMD in areas with high incidence of severe cases should be strengthened to reduce the burden of HFMD cases.
10.Integrated management during the perinatal period for total anomalous pulmonary venous connection.
Yi SUN ; Si-Lin PAN ; Zhi-Xian JI ; Gang LUO ; Hao WAN ; Tao-Tao CHEN ; Ai ZHANG ; Rui CHEN ; Quan-Sheng XING
Chinese Journal of Contemporary Pediatrics 2023;25(5):502-507
OBJECTIVES:
To evaluate the clinical effectiveness of integrated management during the perinatal period for fetuses diagnosed with total anomalous pulmonary venous connection (TAPVC) by prenatal echocardiography.
METHODS:
Clinical data of 64 cases of TAPVC fetuses diagnosed by prenatal echocardiography and managed with integrated perinatal care in Qingdao Women and Children's Hospital from January 2017 to December 2021 were retrospectively analyzed. Integrated perinatal care included multidisciplinary collaboration among obstetrics, fetal medicine, ultrasound, pediatric cardiology, pediatric anesthesia, and neonatology.
RESULTS:
Among the 64 TAPVC fetuses, there were 29 cases of supracardiac type, 27 cases of intracardiac type, 2 cases of infracardiac type, and 6 cases of mixed type. Chromosomal analysis was performed in 42 cases, and no obvious abnormalities were found. Among the 64 TAPVC fetuses, 37 were induced labor, and 27 were followed up until term birth. Among the 27 TAPVC cases, 2 cases accepted palliative care, 2 cases were referred to another hospital for treatment and lost to follow-up, while the remaining 23 cases underwent primary repair surgery. One case died within 6 months after the operation due to low cardiac output syndrome, while the other 22 cases were followed up for (2.1±0.3) years with good outcomes (2 cases underwent a second surgery within 1 year after the first operation due to anastomotic stenosis or pulmonary vein stenosis).
CONCLUSIONS
TAPVC fetuses can achieve good outcomes with integrated management during the perinatal period.
Female
;
Humans
;
Pregnancy
;
Echocardiography
;
Heart Defects, Congenital/surgery*
;
Pulmonary Veins/surgery*
;
Retrospective Studies
;
Scimitar Syndrome/surgery*
;
Infant, Newborn

Result Analysis
Print
Save
E-mail