1.Three-dimensional Electrical Impedance Tomography for Monitoring Gastric Hemorrhage
Zi-Han ZHAO ; Bo SUN ; Jing-Shi HUANG ; Zhi-Wei LI ; Yang WU ; Nan LI ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2026;53(4):1062-1075
ObjectiveGastric hemorrhage is one of the most common and life-threatening emergencies of the upper digestive tract. Early identification and continuous monitoring are essential for reducing rebleeding rates and mortality, particularly within the critical early hours after onset. Although endoscopy and radiological imaging can accurately localize bleeding sites, these approaches are invasive, resource-intensive, and unsuitable for continuous bedside monitoring. Electrical impedance tomography (EIT), as a noninvasive and radiation-free functional imaging technique, offers real-time visualization of conductivity distribution and has the potential for detecting intragastric bleeding based on the electrical contrast between blood and surrounding gastric tissues. In this study, a three-dimensional gastric EIT (3D-gEIT) framework is proposed to achieve noninvasive, real-time, and dynamic monitoring of gastric hemorrhage, with emphasis on spatial localization and quantitative volume assessment. MethodsA three-dimensional upper-abdominal simulation model incorporating the stomach, gastric wall, gastric contents, and surrounding tissues was established. Three electrode configurations, namely the dual layer ring, the four layer staggered ring, and the opposed dual plane array, were designed and systematically compared to evaluate their influence on depth sensitivity and spatial resolution. Based on the Tikhonov-Noser hybrid regularization scheme, a region-clustering constraint was introduced to develop the TK-Noser-RCC algorithm. This approach aggregates spatially adjacent elements with similar conductivity variations, thereby enhancing structural continuity and suppressing isolated noise artifacts. To validate the proposed framework, an upper-abdominal physical phantom was constructed using agar to simulate background tissue conductivity. Hemispherical high-conductivity inclusions with volumes ranging from 10 ml to 50 ml were attached to the inner gastric wall to mimic localized bleeding under different gastric filling states. Boundary voltages were acquired under a 120 kHz excitation current and reconstructed using the TK-Noser-RCC algorithm. Furthermore, an in vivo animal experiment was performed using a porcine model with adult-scale abdominal dimensions. A total of 100 ml of autologous blood was injected incrementally into the stomach to simulate progressive gastric hemorrhage, and time-difference EIT reconstruction was conducted at each injection stage to assess the dynamic system response under physiological conditions. ResultsSimulation results demonstrated that the opposed dual-plane electrode array achieved superior depth sensitivity distribution and spatial resolution. For a 40 ml hemorrhage model, the average ICC and SSIM improved by 55.9% and 38.8% compared with the dual-layer ring configuration, and by 64.0% and 39.5% compared with the four-layer staggered configuration. The proposed region-clustering constraint significantly enhanced reconstruction stability. Under added Gaussian noise of 40 dB and 30 dB, ICC values remained approximately 0.85, indicating effective artifact suppression and preservation of boundary integrity. In physical phantom experiments, reconstructed hemorrhage volumes increased approximately linearly with the preset hemispherical volumes, and the reconstructed high-conductivity regions closely matched the actual bleeding locations. Both empty-stomach and full-stomach conditions were evaluated, demonstrating that the opposed dual-plane configuration maintained stable imaging performance across varying gastric contents. In the animal experiment, reconstructed low-impedance regions expanded progressively with increasing injected blood volume. The spatial localization of the hemorrhage remained stable throughout the procedure, and no significant artifacts were observed. Quantitative analysis showed that reconstructed volume and average conductivity variation exhibited an approximately linear growth trend with injected blood volume, confirming the sensitivity of the system to dynamic intragastric conductivity changes. ConclusionThe proposed 3D-gEIT framework enables quantitative reconstruction of gastric hemorrhage volume and spatial distribution with improved depth sensitivity, structural continuity, and noise robustness compared with conventional EIT approaches. By integrating optimized electrode configuration and a region-clustering-constrained reconstruction algorithm, the system provides stable dynamic monitoring under both controlled phantom conditions and in vivo physiological environments. This method offers a noninvasive, real-time, and low-cost imaging strategy for early diagnosis, postoperative monitoring, and bedside surveillance of gastric bleeding.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Application of a self-designed assistant device for distal osteotomy and reduction in ulnar impaction syndrome
Wei LI ; Mingtong HAN ; Gaofeng ZHANG ; Zhi ZHANG ; Hui XU ; Benlei WEI ; Cunmin RONG ; Bo ZHANG ; Qingluan HAN ; Qing CHANG
Chinese Journal of Orthopaedic Trauma 2025;27(5):451-456
Objective:To investigate the clinical efficacy of a self-designed assistant device for distal ulnar osteotomy and reduction in the surgical treatment of ulnar impaction syndrome.Methods:A retrospective analysis was performed to study the clinical data from the 27 patients with ulnar impaction syndrome who had been treated by distal ulnar shortening and fixation with 2 screws between January 2022 and August 2024 at Department of Hand and Foot Surgery,Affiliated Hospital of Jining Medical University. The cohort included 6 males and 21 females, with 13 left and 14 right sides affected and a mean age of (40.3±10.8) years (range: from 17 to 59 years). Based on their different assistant methods in osteotomy, the patients were divided into group A (15 cases) subjected to conventional freehand osteotomy and group B (12 cases) subjected to distal ulnar osteotomy and reduction assisted by our self-designed assistant device. Comparisons were made between the 2 groups regarding operative time, bone healing time, Mayo wrist function score at postoperative 16 weeks, number of the patients returning to their original occupations and complications.Results:There were no significant dif- ferences in the baseline characteristics between the 2 groups ( P>0.05). All patients were followed up postoperatively for (27.1±11.1) weeks (range: from 16 to 50 weeks). In group B, the operative time [50.0 (50.0, 62.5) min] and bone healing time [6.5 (6.0, 7.0) weeks] were significantly shorter than those in group A [80.0 (67.5, 92.5) min and 7.5 (6.8, 9.0) weeks] ( P<0.05). At postoperative 16 weeks, the Mayo wrist function score was 90.0 (85.0, 96.8) points for group A and 92.5 (85.0, 98.8) points for group B, showing no significant difference ( P>0.05). Five patients in group A and 4 ones in group B returned to their original work status, showing no significant difference either ( P>0.05). One case of non-union occurred in group A while no complication occurred in group B, demonstrating no significant difference either ( P>0.05). Conclusion:In the surgical treatment of ulnar impaction syndrome, compared with conventional freehand osteotomy, application of our self-designed assistant device for distal ulnar osteotomy and reduction is simple, less invasive, and comparable in functional recovery of the wrist, but superior in operative time and bone healing time.
6.Novel lncRNA-miRNA-mRNA competing endogenous RNA triple networks associated programmed cell death in atherosclerosis
Qiong YANG ; Yue-yue SONG ; Yu-han JIA ; Zhi-bo GAI ; Wen-qing YANG ; Dan ZHANG
Chinese Pharmacological Bulletin 2025;41(1):156-163
Aim To mine the competing ceRNA net-works associated with programmed cell death in the pathophysiological mechanisms of atherosclerosis(AS)based on bioinformatics,in order to identify new targets for the diagnosis and treatment of AS.Methods Firstly,the GSE97210 and GSE28858 datasets were screened from the GEO database.Differentially ex-pressed lncRNA,mRNA and miRNA were identified,following which a IncRNA-miRNA-mRNA regulatory network was constructed in Cytoscape 3.7.2 software based on ceRNA theory.Second,GO and KEGG en-richment analysis of mRNA in the ceRNA network was performed.Finally,the mRNAS within the ceRNA net-work were compared with genes related to autophagy,pyroptosis and ferroptosis to establish a ceRNA network related to programmed cell death.Results A total of 1208 DElncRNAS,4723 DEmRNAS and 139 DEmiR-NAS were identified.A ceRNA network was estab-lished,comprising 64 lncRNAS,8 miRNAS and 167 mRNAS.The mRNAS within the CeRNA network were mainly enriched in biological processes such as positive regulation of transcription and migration,protein bind-ing,and signaling pathways including PI3K-Akt signa-ling pathway,and mTOR signaling pathway.Finally,this study established 7 lncRNA-mediated ceRNA regu-latory pathways associated with pyroptosis and 23 ln-cRNA-mediated regulatory pathways for ferroptosis and autophagy.Conclusion This study has successfully constructed a ceRNA network related to programmed cell death,which helps us understand the mechanism by which programmed cell death leads to AS.
7.The Invariant Neural Representation of Neurons in Pigeon’s Ventrolateral Mesopallium to Stereoscopic Shadow Shapes
Xiao-Ke NIU ; Meng-Bo ZHANG ; Yan-Yan PENG ; Yong-Hao HAN ; Qing-Yu WANG ; Yi-Xin DENG ; Zhi-Hui LI
Progress in Biochemistry and Biophysics 2025;52(10):2614-2626
ObjectiveIn nature, objects cast shadows due to illumination, forming the basis for stereoscopic perception. Birds need to adapt to changes in lighting (meaning they can recognize stereoscopic shapes even when shadows look different) to accurately perceive different three-dimensional forms. However, how neurons in the key visual brain area in birds handle these lighting changes remains largely unreported. In this study, pigeons (Columba livia) were used as subjects to investigate how neurons in pigeon’s ventrolateral mesopallium (MVL) represent stereoscopic shapes consistently, regardless of changes in lighting. MethodsVisual cognitive training combined with neuronal recording was employed. Pigeons were first trained to discriminate different stereoscopic shapes (concave/convex). We then tested whether and how light luminance angle and surface appearance of the stereoscopic shapes affect their recognition accuracy, and further verify whether the results rely on specify luminance color. Simultaneously, neuronal firing activity of neurons was recorded with multiple electrode array implanted from the MVL during the presentation of difference shapes. The response was finally analyzed how selectively they responded to different stereoscopic shapes and whether their selectivity was affected by the changes of luminance condition (like lighting angle) or surface look. Support vector machine (SVM) models were trained on neuronal population responses recorded under one condition (light luminance angle of 45°) and used to decode responses under other conditions (light luminance angle of 135°, 225°, 315°) to verify the invariance of responses to different luminance conditions. ResultsBehavioral results from 6 pigeons consistently showed that the pigeons could reliably identify the core 3D shape (over 80% accuracy), and this ability wasn’t affected by changes in light angle or surface appearance. Statistical analysis of 88 recorded neurons from 6 pigeons revealed that 83% (73/88) showed strong selectivity for specific 3D shapes (selectivity index>0.3), and responses to convex shapes were consistently stronger than to concave shapes. These shape-selective responses remained stable across changes in light angle and surface appearance. Neural patterns were consistent under both blue and orange lighting. The decoding accuracy achieves above 70%, suggesting stable responses under different conditions (e.g., different lighting angles or surface appearance). ConclusionNeurons in the pigeon MVL maintain a consistent neural encoding pattern for different stereoscopic shapes, unaffected by illumination or surface appearance. This ensures stable object recognition by pigeons in changing visual environments. Our findings provide new physiological evidence for understanding how birds achieve stable perception (“invariant neural representations”) while coping with variations in the visual field.
8.Effects of dihydroartemisinin on cognitive behavior,β-amyloid and autophagy proteins in brain and retina of 5×FAD mice
Yi-Wei HOU ; Yu YANG ; Zhi-Xin WANG ; Li YI ; Hang ZHOU ; Bei-Han LI ; Hong-Bo YAO ; Han GAO ; Yu-Chun WANG ; Ke-Shuang ZHANG
Acta Anatomica Sinica 2025;56(3):270-276
Objective To explore the pathogenesis of Alzheimer's disease by examining the effects of dihydroartemisinin(DHA)on cognitive behavior,hippocampal,cerebral cortex and retinal cell morphology,β-amyloid(Aβ)and autophagy-related proteins in 5×FAD mice.Methods Twenty 5×FAD mice and 5 wild type(WT)mice were selected,all of which were female.The 5×FAD mice were randomly divided into model(M)group,donepezil(D)group,low-dose DHA(DHA-L)group,and high-dose DHA(DHA-H)group.The WT and M groups were not treated,and the D group was given donepezil 0.1 mg/kg per day.DHA-L group and DHA-H group were given 10 mg/kg and 20 mg/kg DHA per day,respectively.Group D,group DHA-L and group DHA-H were given intragastric administration once a day for 3 months.The changes of in cognitive behavior were measured by Morris experiment.HE staining was used to observe the arrangement and morphology of nerve cells in cerebral cortex,hippocampus and retina.The expressions of Aβ protein in cerebral cortex,hippocampus and retina were detected by immunohistochemistry.Western blotting detected the expression of autophagy related proteins(LC3-Ⅰ,LC3-Ⅱ,Beclin-1,P62,β-actin).Results The DHA-H group and the D group exhibited more frequent adoption of both linear and trending exploration routes.Compared to the model group,significant differences in the contents of Aβ in the hippocampal CA1,cerebral cortex S1,and retinal were observed(P<0.0001)in the other four groups.The analysis also showed significant differences in autophagy-associated proteins between the DHA-L,DHA-H,and model groups(P<0.01).Conclusion DHA improves cognitive function and increases the number of nerve cells in mice.It also reduces Aβ content in the cerebral cortex,hippocampus,and retina,along with improving autophagy-associated protein deposition in mice.
9.Association of Body Mass Index with All-Cause Mortality and Cause-Specific Mortality in Rural China: 10-Year Follow-up of a Population-Based Multicenter Prospective Study.
Juan Juan HUANG ; Yuan Zhi DI ; Ling Yu SHEN ; Jian Guo LIANG ; Jiang DU ; Xue Fang CAO ; Wei Tao DUAN ; Ai Wei HE ; Jun LIANG ; Li Mei ZHU ; Zi Sen LIU ; Fang LIU ; Shu Min YANG ; Zu Hui XU ; Cheng CHEN ; Bin ZHANG ; Jiao Xia YAN ; Yan Chun LIANG ; Rong LIU ; Tao ZHU ; Hong Zhi LI ; Fei SHEN ; Bo Xuan FENG ; Yi Jun HE ; Zi Han LI ; Ya Qi ZHAO ; Tong Lei GUO ; Li Qiong BAI ; Wei LU ; Qi JIN ; Lei GAO ; He Nan XIN
Biomedical and Environmental Sciences 2025;38(10):1179-1193
OBJECTIVE:
This study aimed to explore the association between body mass index (BMI) and mortality based on the 10-year population-based multicenter prospective study.
METHODS:
A general population-based multicenter prospective study was conducted at four sites in rural China between 2013 and 2023. Multivariate Cox proportional hazards models and restricted cubic spline analyses were used to assess the association between BMI and mortality. Stratified analyses were performed based on the individual characteristics of the participants.
RESULTS:
Overall, 19,107 participants with a sum of 163,095 person-years were included and 1,910 participants died. The underweight (< 18.5 kg/m 2) presented an increase in all-cause mortality (adjusted hazards ratio [ aHR] = 2.00, 95% confidence interval [ CI]: 1.66-2.41), while overweight (≥ 24.0 to < 28.0 kg/m 2) and obesity (≥ 28.0 kg/m 2) presented a decrease with an aHR of 0.61 (95% CI: 0.52-0.73) and 0.51 (95% CI: 0.37-0.70), respectively. Overweight ( aHR = 0.76, 95% CI: 0.67-0.86) and mild obesity ( aHR = 0.72, 95% CI: 0.59-0.87) had a positive impact on mortality in people older than 60 years. All-cause mortality decreased rapidly until reaching a BMI of 25.7 kg/m 2 ( aHR = 0.95, 95% CI: 0.92-0.98) and increased slightly above that value, indicating a U-shaped association. The beneficial impact of being overweight on mortality was robust in most subgroups and sensitivity analyses.
CONCLUSION
This study provides additional evidence that overweight and mild obesity may be inversely related to the risk of death in individuals older than 60 years. Therefore, it is essential to consider age differences when formulating health and weight management strategies.
Humans
;
Body Mass Index
;
China/epidemiology*
;
Male
;
Female
;
Middle Aged
;
Prospective Studies
;
Rural Population/statistics & numerical data*
;
Aged
;
Follow-Up Studies
;
Adult
;
Mortality
;
Cause of Death
;
Obesity/mortality*
;
Overweight/mortality*
10.Outcome indicators in randomized controlled trials of traditional Chinese medicine treatment of post-stroke depression.
Jin HAN ; Yue YUAN ; Fang-Biao XU ; Yan-Bo SONG ; Yong-Kang SUN ; Xin-Zhi WANG
China Journal of Chinese Materia Medica 2025;50(2):542-559
This study systematically reviewed the randomized controlled trial(RCT) of traditional Chinese medicine(TCM) treatment of post-stroke depression(PSD) and analyzed the clinical study characteristics and outcome indicators, aiming to optimize the design and establish the core outcome set in the future clinical trials of the TCM treatment of PSD. PubMed, Web of Science, Cochrane Library, EMbase, CNKI, VIP, Wanfang, and SinoMed were searched for the relevant RCT published in recent 3 years. The basic characteristics, intervention measures, and outcome indicators of the included RCT were extracted, and the descriptive analysis was carried out. A total of 76 RCTs were eventually included, with the sample size concentrated in 80-100 cases. The most frequent TCM syndromes were liver depression and Qi stagnation(15 times, 31.91%) and phlegm combined with stasis(5 times, 10.63%). The frequency of intervention methods followed a descending trend of TCM decoction(35 times, 46.05%) and TCM decoction + acupuncture(4 times, 5.26%), Chinese patent medicine(3 times, 3.94%), and the intervention mainly lasted for 1 to 3 months(43 times, 60.56%). The adverse reactions of patients were mainly digestive system reaction(150 patients, 39.37%) and nervous system reaction(112 patients, 29.39%). Most of the included studies had unclear risk of bias, involving 84 outcome indicators, which belonged to 8 indicator domains. The RCTs of TCM treatment of PSD showed a variety of problems, such as non-standard TCM syndrome differentiation, inconsistent names of TCM syndrome scores and measurement tools, low quality, unclear risk of bias, neglect of endpoint indicators, unreasonable selection of substitute indicators, lack of differentiation between primary and secondary outcome indicators, non-standard reporting of safety indicators, insufficient attention to economic indicators, and lack of long-term prognosis evaluation. It is suggested that the future research should improve the quality of methodology and build a standardized core outcome set to promote the development of high-quality clinical research in this field.
Humans
;
Randomized Controlled Trials as Topic
;
Drugs, Chinese Herbal/administration & dosage*
;
Stroke/psychology*
;
Depression/etiology*
;
Treatment Outcome
;
Medicine, Chinese Traditional

Result Analysis
Print
Save
E-mail