1.Effect of Acupuncture at Neiguan (PC6) on Improving Autism by Promoting Myelination Through The METTL14/m⁶A/PTEN Axis Based on “Xuanfu-Suiqiao” Theory
Wei-Li DANG ; Lü-Yuan LIANG ; Yu-Xin LI ; Zhi-Yao LI ; Sai-Dan LIU ; Jia-Lei CAO ; Rong-Ze MA ; Yun-Kai WANG ; Xiao-Qing YANG ; Bing-Qi WEI ; Bing-Xiang MA
Progress in Biochemistry and Biophysics 2026;53(5):1165-1177
ObjectiveTo clarify whether METTL14 mediates the core role of acupuncture at Neiguan (PC6) in promoting myelination and improving behavior in young autistic rats through gene intervention technology. MethodsThe ASD model was established by intraperitoneal injection of valproic acid (VPA) in pregnant rats. Male offspring were intracerebroventricularly injected with adenovirus-packaged METTL14 shRNA (sh-METTL14) or its control (sh-NC) on postnatal day 1, with a model group set as well. Subsequently, the juvenile rats were divided into model group, acupuncture group, acupuncture+sh-NC group, and acupuncture+sh-METTL14 group. The acupuncture group received acupuncture at Neiguan (PC6) from postnatal day 7, once daily for 21 consecutive days. Neurobehavioral changes were evaluated by behavioral tests; METTL14 knockdown efficiency and the expression of METTL14, METTL3, and PTEN were detected by quantitative real-time PCR (qRT-PCR) and Western blot (WB); PTEN m6A levels were measured by RNA immunoprecipitation-qPCR (RIP-qPCR); myelin ultrastructure, expression of myelin basic protein (MBP) and neurofascin 155 (NF155), and dendritic spine density were observed using transmission electron microscopy (TEM), enzyme-linked immunosorbent assay (ELISA), immunofluorescence, qRT-PCR, and primary neuron culture. ResultsBehaviorally, knockdown of METTL14 significantly counteracted the beneficial effects of acupuncture in improving self-grooming, open field exploration, three-chamber social interaction, and Morris water maze learning and memory (P<0.05, P<0.01). Compared with the acupuncture+sh-NC group, the acupuncture+sh-METTL14 group showed significantly decreased mRNA and protein expression of hippocampal METTL14 (P<0.01), and the upregulating effects of acupuncture on METTL3 and PTEN expression were reversed (P<0.01). Meanwhile, knockdown of METTL14 significantly inhibited the acupuncture-induced increase in PTEN m6A levels (P<0.01). Morphologically, knockdown of METTL14 attenuated the improvement of myelin structure by acupuncture, reversed the downregulation of MBP and upregulation of NF155 induced by acupuncture, and blocked the increase in dendritic spine density (P<0.05, P<0.01). ConclusionMETTL14 is a key molecule mediating the therapeutic effect of acupuncture at Neiguan. Acupuncture at Neiguan upregulates METTL14, thereby enhancing m6A methylation modification of PTEN mRNA to stabilize its expression, ultimately promoting myelin development and improving behavioral symptoms in ASD juvenile rats. This preliminarily reveals the modern biological connotation of “opening Xuanfu and dredging myelin”.
2.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
3.Effect of Acupuncture at Neiguan (PC6) on Improving Autism by Promoting Myelination Through The METTL14/m⁶A/PTEN Axis Based on “Xuanfu-Suiqiao” Theory
Wei-Li DANG ; Lü-Yuan LIANG ; Yu-Xin LI ; Zhi-Yao LI ; Sai-Dan LIU ; Jia-Lei CAO ; Rong-Ze MA ; Yun-Kai WANG ; Xiao-Qing YANG ; Bing-Qi WEI ; Bing-Xiang MA
Progress in Biochemistry and Biophysics 2026;53(5):1165-1177
ObjectiveTo clarify whether METTL14 mediates the core role of acupuncture at Neiguan (PC6) in promoting myelination and improving behavior in young autistic rats through gene intervention technology. MethodsThe ASD model was established by intraperitoneal injection of valproic acid (VPA) in pregnant rats. Male offspring were intracerebroventricularly injected with adenovirus-packaged METTL14 shRNA (sh-METTL14) or its control (sh-NC) on postnatal day 1, with a model group set as well. Subsequently, the juvenile rats were divided into model group, acupuncture group, acupuncture+sh-NC group, and acupuncture+sh-METTL14 group. The acupuncture group received acupuncture at Neiguan (PC6) from postnatal day 7, once daily for 21 consecutive days. Neurobehavioral changes were evaluated by behavioral tests; METTL14 knockdown efficiency and the expression of METTL14, METTL3, and PTEN were detected by quantitative real-time PCR (qRT-PCR) and Western blot (WB); PTEN m6A levels were measured by RNA immunoprecipitation-qPCR (RIP-qPCR); myelin ultrastructure, expression of myelin basic protein (MBP) and neurofascin 155 (NF155), and dendritic spine density were observed using transmission electron microscopy (TEM), enzyme-linked immunosorbent assay (ELISA), immunofluorescence, qRT-PCR, and primary neuron culture. ResultsBehaviorally, knockdown of METTL14 significantly counteracted the beneficial effects of acupuncture in improving self-grooming, open field exploration, three-chamber social interaction, and Morris water maze learning and memory (P<0.05, P<0.01). Compared with the acupuncture+sh-NC group, the acupuncture+sh-METTL14 group showed significantly decreased mRNA and protein expression of hippocampal METTL14 (P<0.01), and the upregulating effects of acupuncture on METTL3 and PTEN expression were reversed (P<0.01). Meanwhile, knockdown of METTL14 significantly inhibited the acupuncture-induced increase in PTEN m6A levels (P<0.01). Morphologically, knockdown of METTL14 attenuated the improvement of myelin structure by acupuncture, reversed the downregulation of MBP and upregulation of NF155 induced by acupuncture, and blocked the increase in dendritic spine density (P<0.05, P<0.01). ConclusionMETTL14 is a key molecule mediating the therapeutic effect of acupuncture at Neiguan. Acupuncture at Neiguan upregulates METTL14, thereby enhancing m6A methylation modification of PTEN mRNA to stabilize its expression, ultimately promoting myelin development and improving behavioral symptoms in ASD juvenile rats. This preliminarily reveals the modern biological connotation of “opening Xuanfu and dredging myelin”.
4.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
5.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
6.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
7.Application progress of grounded theory in hospice care
Yunrong LI ; Tiantian WANG ; Bing WU ; Guoren ZHOU ; Liuliu ZHANG ; Xiaoxu ZHI ; Yun ZHAO
Chinese Journal of Modern Nursing 2025;31(29):3946-3951
Grounded theory, as a flexible and systematic research method, serves as an important tool for gaining an in-depth understanding of clinical phenomena and nursing practice. This paper reviews the origin and development of grounded theory, its concepts and classifications, methodological procedures, and the necessity, significance, and current status of its application in the field of hospice care. The aim is to enhance the scientific application of grounded theory in hospice care research in China.
8.Development and application of pilot hypoxia endurance testing system
Lin-xia LI ; Guo-yun MAO ; Ming-rui HU ; Jia-ling XU ; Yao-xuan JI ; Na ZHI ; Yan-qing BAI ; Yun-ying WANG
Chinese Medical Equipment Journal 2025;46(10):23-28
Objective To develop a hypoxia endurance testing system for aviation physiological training of pilots.Methods The hypoxia endurance testing system comprised a low-oxygen mixed gas generator,a pressurization system for low-oxygen mixed gas and a personal breathing apparatus.The low-oxygen mixed gas generator consisted of a main unit composed of an air compressor,a filter,a buffer tank,polymer membrane,a control module,sensors and regulators,wire cables,supporting hoses,etc.;the pressurization system for low-oxygen mixed gas was made up of a protective box,a cooling fan,a motor and a driver,a control module,a solenoid valve,a convergence block,a pressure gauge,etc.;the personal breating apparatus was composed of a gas cylinder,a pressure reducer,an oxygen supply regulator,etc.Forty-eight subjects were selected for hypoxia exposure tests to verify the effectiveness of the system.Results The system developed had the functions of low-oxygen gas preparation,pressurized filling and hypoxia experiment,and the experimental results indicated the acute hypoxia exposure by the system significantly caused signs and symptoms of hypoxia and weakened physiological functions.Conclusion The system developed gains advantages in high accuracy of gas volume fraction control,safety and remarkable effect of simulated hypoxia,and can be an effective tool for acute high-altitude hypoxia testing and training of pilots.[Chinese Medical Equipment Journal,2025,46(10):23-28]
9.RCM method-based study on preventive maintenance strategy of heating,ventilation and air-conditioning system in pharmacy intravenous admixture services
Liu-liu ZONG ; Yun-zhi YANG ; Jing ZHAO ; Yun MO ; Dong-hui LAO ; Jian-zhong ZHANG ; Xiao-yu LI ; Qian-zhou LYU
Chinese Medical Equipment Journal 2025;46(10):78-83
Objective To propose a preventive maintenance strategy of the heating,ventilation and air-conditioning(HVAC)system in pharmacy intravenous admixture services(PIVAS)based on the reliability centered maintenance(RCM)method so as to provide references for PIVAS equipment maintenance.Methods Firstly,a HVAC system RCM review team was formed,and the failure modes and impacts of important functional components of the equipment were analyzed to clarify the consequences of the failure of each functional component under the premise of ensuring the safety and integrity of the equipment and with the goal of minimizing the loss of maintenance downtime and the consumption of maintenance resources.Secondly,with a standardized logical decision-making procedure the preventive maintenance strategy was determined and implemented based on the consequences of functional failure.Finally,statistical analyses were carried out on such equipment indicators as performance parameter qualification rate,failure rate and maintenance cost before and after the RCM method-based strategy was executed,in order to evaluate the efficacy of the strategy.Results The RCM method-based preventive maintenance strategy had the performance qualification rate increased from 97.47%to 99.06%(χ2=24.139,P<0.01),the failure rate decreased from 0.24%to 0.03%(χ2=13.519,P<0.01)and the maintenance cost reduced by 11.5%,from RMB 134,200 to 118,700.Conclusion The RCM method-based preventive maintenance strategy provides reliable equipment for PIVAS and lowers the maintenance cost effectively,and references are given for the development of automated and intelligent equipment maintenance strategies for PIVAS.[Chinese Medical Equipment Journal,2025,46(10):78-83]
10.Establishment of near-infrared spectroscopy quantitative models for moisture and index components in Alismatis Rhizoma decoction pieces
Xun LU ; Zhe ZHANG ; Geng-zhi ZHAN ; Lu-yao CAI ; Cun-yu LI ; Yun-feng ZHENG ; Tuan-jie WANG ; Yu JIN ; Guo-ping PENG
Chinese Traditional Patent Medicine 2025;47(10):3184-3190
AIM To establish the near-infrared spectroscopy quantitative models for moisture,23-acetylalismol B and 23-acetylalismol C in Alismatis Rhizoma decoction pieces.METHODS The near-infrared spectroscopy(NIRS)data were collected in 95 batches of decoction pieces,after which drying method was adopted in the content determination of moisture,HPLC was applied to determining the contents of 23-acetylalismol B and 23-acetylalismol C,the quantitative models were established by partial least squares method combined with feature extraction algorithms.RESULTS The model training determination coefficients were 0.952 6,0.958 1 and 0.920 8,along with the prediction determination coefficients of 0.930 0,0.905 2 and 0.906 4,the residual prediction deviations(PRD)of 4.00,3.58 and 3.46,and the root mean square error ratios of prediction values to calibration values(RMSEP/RMSEC)of 1.15,1.11 and 1.06,respectively.CONCLUSION The quantitative models based on NIRS exhibit good prediction effects,which can be used for the rapid quality detection of Alismatis Rhizoma decoction pieces.

Result Analysis
Print
Save
E-mail