1.Construction and Optimization of Alzheimer's Disease Classification Model Based on Brain Mixed Function Network Topology Parameters and Machine Learning
Xiao-yu HAN ; Xiu-zhu JIA ; Yang LI ; Meng-ying LOU ; Yong-qi NIE ; Xin-ping GUO ; Lu YU ; Zhi-yuan LI ; Lian-zheng SU
Progress in Modern Biomedicine 2025;25(11):1770-1778
Objective:To explore the interrelationship between brain functional networks and features in functional magnetic resonance imaging(fMRI)of patients with Alzheimer's disease(AD),and to construct mixed-function networks(MFN),and apply them in machine learning classification models to improve the accuracy of AD classification.Methods:102 AD patients and 227 healthy subjects in the Alzheimer's Neuroimaging Initiative(ADNI)dataset were retrospectively analyzed.The partial correlation brain network of the blood oxygen level dependent(BOLD)signal was calculated and fused with low-frequency wave amplitude(ALFF),fractional low-frequency wave amplitude(fALFF)and local consistency(ReHo)features to construct MFN.Network topology parameters were extracted,and a variety of machine learning classification models were constructed based on MFN topological parameters,accuracy,precision,recall and area under the curve(AUC)were used to evaluate the predictive efficiency of the models.Results:By constructed MFN and calculated intra group to inter group ratio(IIGR),35 features could be obtained from ALFF,fALFF and ReHo feature topological parameter analysis,after rank sum test and FDR correction,there were statistical differences among 28 features(P<0.05).The classification results show that,all the five classifiers have high classification performance on the test data set.The accuracy,precision and recall rates of random forest(RF),adaptive lifting algorithm(AdaBoost),guided aggregation algorithm(Bagging)and support vector machine(SVM)were all 99.7%,and the AUC values were up to 100%,99.5%,99.1%and 99.5%,respectively.The accuracy(98.5%),precision(98.5%),recall(98.5%),and AUC(99.1%)of the multi-layer perceptron(MLP)were slightly lower than other models,but remained excellent.It was worth noting that RF has the highest AUC value of all models at 100.0%,while Bagging has the lowest AUC value(99.1%)in the integrated approach.The results of performance comparison show that,MFN classification model can significantly improve the recognition and classification of AD disease,and greatly improve the performance of various indicators of the classifier.The results showed that,MFN classification model was superior to intelligent classification based fusion,DBN-based multitask learning,PVT-TSVM,unsupervised learning and clustering,SVM and SVM of degree 3 polynomial kernel function in key indicators such as accuracy(99.13%),AUC(99.42%),recall rate(99.46%)and specificity(99.42%)with plasma proteins,machine learning algorithms.It was further proved that MFN classification model has good generalization ability and robustness in AD disease classification.Conclusion:The AD classification model constructed based on brain mixed function network topology parameters and machine learning can improve the accuracy of AD classification.
2.Analysis of risk factors for high-risk colorectal adenoma:focusing on non-alcoholic fatty liver disease and multiple metabolic abnormalities
Long-yun WU ; Xiao-ling LI ; Zhi-yi HAN ; Qiao-yun XIA ; Jing-yuan XU ; Pei-ying TIAN ; Xiao-lan LU
Fudan University Journal of Medical Sciences 2025;52(2):216-224
Objective To retrospectively analyze the association between metabolic factors and high-risk colorectal adenoma(CRA).Methods The medical records of patients aged 18-75 years who underwent their initial colonoscopy at Karamay Central Hospital of Xinjiang Uygur Autonomous Region from Jul 2000 to Mar 2017 were collected.The comparison between normal colonoscopy(NC)and high-risk CRA patients was conducted using an unpaired t-test,while chi-square test was used for categorical variables.Least absolute shrinkage and selection operator(LASSO)regression and Logistic regression were utilized to analyze the association between metabolic factors and high-risk CRA.Results A total of 1 798 patients meeting the inclusion and exclusion criteria were enrolled and divided into normal colonoscopy(NC)findings group(n=972)and high-risk CRA group(n=826).The high-risk CRA group exhibited significantly lower levels of high-density lipoprotein cholesterol(HDL-C)in comparison to the NC group,while uric acid and fibrosis 4(FIB-4)index levels were significantly higher than those observed in the NC group(all P<0.05).Based on LASSO regression analysis,we identified 12 variables that potentially influence the occurrence of high-risk CRA,including age,gender,smoking history,alcohol consumption history,non-alcoholic fatty liver disease(NAFLD),hypertension,coronary artery disease,hyperglycemia,hypercholesterolemia,low levels of HDL-C,elevated alanine aminotransferase,and elevated gamma-glutamyl transferase.Multivariate analysis revealed that individuals aged over 50 years,male gender,cigarette and alcohol consumption,low HDL-C levels,history of NAFLD and hypertension were identified as independent risk factors associated with high-risk CRA(P<0.05).In addition,without or with adjusting for age,sex,smoking,and drinking history,patients with a high TG/HDL-C ratio(the ratio≥2.68)had a significantly higher risk of high-risk CRA than those with a low TG/HDL-C ratio(the ratio<2.68)[odds ratios(ORs)were1.430 and 1.235 respectively,all P<0.05)].Without or with adjusting variables,the ORs for NAFLD patients with FIB-4 index>2.67 were 1.849(P=0.466)and 1.435(P=0.707),respectively.Conclusion A significant association exists between metabolic factors and high-risk CRA.Independent risk factors for high-risk CRA include older age(≥50 years),male,smoking history,alcohol consumption history,low levels of HDL-C,and a history of NAFLD and hypertension.Individuals exhibiting a TG/HDL-C ratio exceeding 2.68 manifest a significantly heightened susceptibility to the development of high-risk CRA.Therefore,elderly males with one or more aforementioned metabolic abnormalities should be considered a priority population for colorectal screening.
3.Construction and Optimization of Alzheimer's Disease Classification Model Based on Brain Mixed Function Network Topology Parameters and Machine Learning
Xiao-yu HAN ; Xiu-zhu JIA ; Yang LI ; Meng-ying LOU ; Yong-qi NIE ; Xin-ping GUO ; Lu YU ; Zhi-yuan LI ; Lian-zheng SU
Progress in Modern Biomedicine 2025;25(11):1770-1778
Objective:To explore the interrelationship between brain functional networks and features in functional magnetic resonance imaging(fMRI)of patients with Alzheimer's disease(AD),and to construct mixed-function networks(MFN),and apply them in machine learning classification models to improve the accuracy of AD classification.Methods:102 AD patients and 227 healthy subjects in the Alzheimer's Neuroimaging Initiative(ADNI)dataset were retrospectively analyzed.The partial correlation brain network of the blood oxygen level dependent(BOLD)signal was calculated and fused with low-frequency wave amplitude(ALFF),fractional low-frequency wave amplitude(fALFF)and local consistency(ReHo)features to construct MFN.Network topology parameters were extracted,and a variety of machine learning classification models were constructed based on MFN topological parameters,accuracy,precision,recall and area under the curve(AUC)were used to evaluate the predictive efficiency of the models.Results:By constructed MFN and calculated intra group to inter group ratio(IIGR),35 features could be obtained from ALFF,fALFF and ReHo feature topological parameter analysis,after rank sum test and FDR correction,there were statistical differences among 28 features(P<0.05).The classification results show that,all the five classifiers have high classification performance on the test data set.The accuracy,precision and recall rates of random forest(RF),adaptive lifting algorithm(AdaBoost),guided aggregation algorithm(Bagging)and support vector machine(SVM)were all 99.7%,and the AUC values were up to 100%,99.5%,99.1%and 99.5%,respectively.The accuracy(98.5%),precision(98.5%),recall(98.5%),and AUC(99.1%)of the multi-layer perceptron(MLP)were slightly lower than other models,but remained excellent.It was worth noting that RF has the highest AUC value of all models at 100.0%,while Bagging has the lowest AUC value(99.1%)in the integrated approach.The results of performance comparison show that,MFN classification model can significantly improve the recognition and classification of AD disease,and greatly improve the performance of various indicators of the classifier.The results showed that,MFN classification model was superior to intelligent classification based fusion,DBN-based multitask learning,PVT-TSVM,unsupervised learning and clustering,SVM and SVM of degree 3 polynomial kernel function in key indicators such as accuracy(99.13%),AUC(99.42%),recall rate(99.46%)and specificity(99.42%)with plasma proteins,machine learning algorithms.It was further proved that MFN classification model has good generalization ability and robustness in AD disease classification.Conclusion:The AD classification model constructed based on brain mixed function network topology parameters and machine learning can improve the accuracy of AD classification.
4.Analysis of risk factors for high-risk colorectal adenoma:focusing on non-alcoholic fatty liver disease and multiple metabolic abnormalities
Long-yun WU ; Xiao-ling LI ; Zhi-yi HAN ; Qiao-yun XIA ; Jing-yuan XU ; Pei-ying TIAN ; Xiao-lan LU
Fudan University Journal of Medical Sciences 2025;52(2):216-224
Objective To retrospectively analyze the association between metabolic factors and high-risk colorectal adenoma(CRA).Methods The medical records of patients aged 18-75 years who underwent their initial colonoscopy at Karamay Central Hospital of Xinjiang Uygur Autonomous Region from Jul 2000 to Mar 2017 were collected.The comparison between normal colonoscopy(NC)and high-risk CRA patients was conducted using an unpaired t-test,while chi-square test was used for categorical variables.Least absolute shrinkage and selection operator(LASSO)regression and Logistic regression were utilized to analyze the association between metabolic factors and high-risk CRA.Results A total of 1 798 patients meeting the inclusion and exclusion criteria were enrolled and divided into normal colonoscopy(NC)findings group(n=972)and high-risk CRA group(n=826).The high-risk CRA group exhibited significantly lower levels of high-density lipoprotein cholesterol(HDL-C)in comparison to the NC group,while uric acid and fibrosis 4(FIB-4)index levels were significantly higher than those observed in the NC group(all P<0.05).Based on LASSO regression analysis,we identified 12 variables that potentially influence the occurrence of high-risk CRA,including age,gender,smoking history,alcohol consumption history,non-alcoholic fatty liver disease(NAFLD),hypertension,coronary artery disease,hyperglycemia,hypercholesterolemia,low levels of HDL-C,elevated alanine aminotransferase,and elevated gamma-glutamyl transferase.Multivariate analysis revealed that individuals aged over 50 years,male gender,cigarette and alcohol consumption,low HDL-C levels,history of NAFLD and hypertension were identified as independent risk factors associated with high-risk CRA(P<0.05).In addition,without or with adjusting for age,sex,smoking,and drinking history,patients with a high TG/HDL-C ratio(the ratio≥2.68)had a significantly higher risk of high-risk CRA than those with a low TG/HDL-C ratio(the ratio<2.68)[odds ratios(ORs)were1.430 and 1.235 respectively,all P<0.05)].Without or with adjusting variables,the ORs for NAFLD patients with FIB-4 index>2.67 were 1.849(P=0.466)and 1.435(P=0.707),respectively.Conclusion A significant association exists between metabolic factors and high-risk CRA.Independent risk factors for high-risk CRA include older age(≥50 years),male,smoking history,alcohol consumption history,low levels of HDL-C,and a history of NAFLD and hypertension.Individuals exhibiting a TG/HDL-C ratio exceeding 2.68 manifest a significantly heightened susceptibility to the development of high-risk CRA.Therefore,elderly males with one or more aforementioned metabolic abnormalities should be considered a priority population for colorectal screening.
5.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
6.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
7.Application of ultrasound-guided needling assisted the motor evoked potentials and electromyography monitoring in spinal surgery
Jing HU ; Hai-lin LI ; Zhi-qiang WU ; Jia-cheng LU ; Zi-xuan YUAN ; Yu-xi SUN ; Hui-bo WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(11):960-964
Objective To explore the effect and predictive value of ultrasound-guided needling assisted motor evoked potentials(MEP)and electromyography(EMG)monitoring on neurological recovery in spinal surgery.Methods A retrospective analysis was conducted on the clinical data of 80 patients who underwent spinal surgery at Jiangsu Province Hospital of Chinese Medicine from January 2020 to December 2024.A total of 41 patients in the observation group received ultrasound-guided needling assisted MEP and EMG monitoring,and 39 patients in the control group received conventional method for MEP and EMG monitoring.The operative time,intraoperative blood loss,and the proportions of intraoperative MEP and EMG warnings were compared between the two groups,and the sensitivity and specificity of intraoperative MEP monitoring were compared between the two groups.The receiver operating characteristic(ROC)curve was plotted,and the area under the curve(AUC)was calculated to analyze the efficiency of MEP warning in predicting the dysfunction of postoperative spinal cord.Results There were no significant differences in the operative time,intraoperative blood loss,or the proportions of intraoperative MEP and EMG warnings(P>0.05).The sensitivity,specificity and AUC of intraoperative MEP monitoring in the observation group were significantly higher than those in the control group,with statistically significant differences(P<0.05).The sensitivity,specificity,and AUC of postoperative MEP warning in predicting the dysfunction of spinal cord in the observation group were higher than those in the control group,with statistically significant differences(P<0.05).Conclusion Ultrasound-guided needling assisted MEP and EMG monitoring can effectively enhance the intraoperative neural monitoring accuracy,and postoperative MEP warning demonstrates superior predictive value for postoperative neurological dysfunction.
8.Application of ultrasound-guided needling assisted the motor evoked potentials and electromyography monitoring in spinal surgery
Jing HU ; Hai-lin LI ; Zhi-qiang WU ; Jia-cheng LU ; Zi-xuan YUAN ; Yu-xi SUN ; Hui-bo WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(11):960-964
Objective To explore the effect and predictive value of ultrasound-guided needling assisted motor evoked potentials(MEP)and electromyography(EMG)monitoring on neurological recovery in spinal surgery.Methods A retrospective analysis was conducted on the clinical data of 80 patients who underwent spinal surgery at Jiangsu Province Hospital of Chinese Medicine from January 2020 to December 2024.A total of 41 patients in the observation group received ultrasound-guided needling assisted MEP and EMG monitoring,and 39 patients in the control group received conventional method for MEP and EMG monitoring.The operative time,intraoperative blood loss,and the proportions of intraoperative MEP and EMG warnings were compared between the two groups,and the sensitivity and specificity of intraoperative MEP monitoring were compared between the two groups.The receiver operating characteristic(ROC)curve was plotted,and the area under the curve(AUC)was calculated to analyze the efficiency of MEP warning in predicting the dysfunction of postoperative spinal cord.Results There were no significant differences in the operative time,intraoperative blood loss,or the proportions of intraoperative MEP and EMG warnings(P>0.05).The sensitivity,specificity and AUC of intraoperative MEP monitoring in the observation group were significantly higher than those in the control group,with statistically significant differences(P<0.05).The sensitivity,specificity,and AUC of postoperative MEP warning in predicting the dysfunction of spinal cord in the observation group were higher than those in the control group,with statistically significant differences(P<0.05).Conclusion Ultrasound-guided needling assisted MEP and EMG monitoring can effectively enhance the intraoperative neural monitoring accuracy,and postoperative MEP warning demonstrates superior predictive value for postoperative neurological dysfunction.
9.Construction of medical consumables selection indicator system based on analytic hierarchy process and fuzzy cluster method
Li-ping FAN ; Miao XIAO ; Guo-zhong LU ; Wei WANG ; Yu-yuan DENG ; Zhi-hong CHEN
Chinese Medical Equipment Journal 2025;46(11):78-83
Objective To construct a medical consumables selection indicator system based on analytic hierarchy process(AHP)and fuzzy cluster method.Methods Firstly,a medical consumables selection indicator system was established preliminarily with the literature research results and actual situation of hospital consumables management;secondly,13 experts in related fields were selected to execute two rounds of online questionnaires,the expert weights were determined with AHP,the importance of each selection indicator was scored by the expert evaluation method and fuzzy cluster method,and consistency analysis was carried out on the two rounds of expert evaluation results;finally,the final medical consumables selection indicator system was built with the 100-point scale.Results The constructed medical consumables selection indicator system was composed of 5 primary indicators,12 secondary indicators and 38 tertiary indicators.The primary indicators included consumables quality,clinical demand,cost-effectiveness,supply capacity and after-sales service,with the percentage-based scores being 27,25,14,26 and 8,respectively.Conclusion The medical consumables selection indicator system based on AHP and fuzzy cluster method with high reliability provides effective and reliable references for medical institutions to select medical consumables.
10.Construction of medical consumables selection indicator system based on analytic hierarchy process and fuzzy cluster method
Li-ping FAN ; Miao XIAO ; Guo-zhong LU ; Wei WANG ; Yu-yuan DENG ; Zhi-hong CHEN
Chinese Medical Equipment Journal 2025;46(11):78-83
Objective To construct a medical consumables selection indicator system based on analytic hierarchy process(AHP)and fuzzy cluster method.Methods Firstly,a medical consumables selection indicator system was established preliminarily with the literature research results and actual situation of hospital consumables management;secondly,13 experts in related fields were selected to execute two rounds of online questionnaires,the expert weights were determined with AHP,the importance of each selection indicator was scored by the expert evaluation method and fuzzy cluster method,and consistency analysis was carried out on the two rounds of expert evaluation results;finally,the final medical consumables selection indicator system was built with the 100-point scale.Results The constructed medical consumables selection indicator system was composed of 5 primary indicators,12 secondary indicators and 38 tertiary indicators.The primary indicators included consumables quality,clinical demand,cost-effectiveness,supply capacity and after-sales service,with the percentage-based scores being 27,25,14,26 and 8,respectively.Conclusion The medical consumables selection indicator system based on AHP and fuzzy cluster method with high reliability provides effective and reliable references for medical institutions to select medical consumables.

Result Analysis
Print
Save
E-mail