1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Relationship of physical activity and screen time with overweight and obesity among children and adolescents with special needs in Tianjin
HAN Yu, LI Zhi, LI Penghong, CUI Tingkai, XIONG Wenjuan, QU Zhiyi, XI Wei, ZHANG Xin
Chinese Journal of School Health 2025;46(2):162-166
Objective:
To investigate the association of physical activity and screen time with overweight and obesity among children and adolescents with special needs in Tianjin, so as to provide scientific evidence for childhood obesity prevention and intervention measures in the population.
Methods:
From January 2022 to June 2024, 296 children and adolescents with intellectual disabilities and autism spectrum disorders aged 2-18 years were recruited from special education schools and institutions in Tianjin. Height and weight were measured, and a standardized questionnaire was used to assess physical activity and screen time. Binary Logistic regression analysis was carried out to investigate the association of physical activity and screen time with overweight and obesity.
Results:
The prevalence of overweight and obesity among children and adolescents with special needs in Tianjin were 17.2% and 21.6%, respectively, and the combined prevalence of overweight and obesity was 38.9%. The median of moderatetovigorous physical activity (MVPA) time was 0.20 h/d, and physical activity sufficiency rate was 7.8%. The median of screen time was 1.79 h/d, and the screen time compliance rate was 68.2%. The binary Logistic regression results showed that lower levels of MVPA time and increased screen time were associated with a higher risk of overweight and obesity among children and adolescents with special needs [OR(95%CI)=1.80(1.06-3.07), 2.40(1.42-4.07),P<0.05].
Conclusions
Insufficient physical activity and excessive screen time are associated with an increased risk of overweight and obesity among children and adolescents with special needs. Therefore, comprehensive intervention measures should be implemented as early as possible to prevent and reduce the incidence of overweight and obesity in this population.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.A Novel Mouse Model Unveils Protein Deficiency in Truncated CDKL5 Mutations.
Xue FENG ; Zi-Ai ZHU ; Hong-Tao WANG ; Hui-Wen ZHOU ; Ji-Wei LIU ; Ya SHEN ; Yu-Xian ZHANG ; Zhi-Qi XIONG
Neuroscience Bulletin 2025;41(5):805-820
Mutations in the cyclin-dependent kinase-like 5 gene (CDKL5) cause a severe neurodevelopmental disorder, yet the impact of truncating mutations remains unclear. Here, we introduce the Cdkl5492stop mouse model, mimicking C-terminal truncating mutations in patients. 492stop/Y mice exhibit altered dendritic spine morphology and spontaneous seizure-like behaviors, alongside other behavioral deficits. After creating cell lines with various Cdkl5 truncating mutations, we found that these mutations are regulated by the nonsense-mediated RNA decay pathway. Most truncating mutations result in CDKL5 protein loss, leading to multiple disease phenotypes, and offering new insights into the pathogenesis of CDKL5 disorder.
Animals
;
Disease Models, Animal
;
Mice
;
Protein Serine-Threonine Kinases/deficiency*
;
Mutation/genetics*
;
Epileptic Syndromes/genetics*
;
Humans
;
Dendritic Spines/pathology*
;
Spasms, Infantile/genetics*
;
Male
;
Seizures/genetics*
;
Mice, Inbred C57BL
8.Electrocardiogram signal quality estimation by the similarity of heartbeat morphology and wave slope character
Yu ZHANG ; Zhi XU ; Xinming YU ; Jinzhong SONG ; Zhongping CAO ; Linghao XIONG ; Yong XUAN
Space Medicine & Medical Engineering 2025;36(3):225-229
Objective Electrocardiogram(ECG)signal quality degrades when the level of activity is high and motion artifacts are severe.Poor quality signals may result in false alarms,poor patient monitoring,imprecise measurement,and misleading diagnosis.The quantitative assessment of ECG signal quality forms the basis of automatic ECG noise reduction and heart disease diagnosis.Methods The ECG signal quality index(SQI)was obtained by statistically analyzing the heartbeat similarity and the slope character,respectively,namely rSQI and kSQI.Results Using MIT-BIH Noise Stress Test Database to test,both rSQI and kSQI decreased when the Signal Noise Ratio(SNR)decreased,which revealed the ECG signal quality.Based on the quasiperiodic property,the waveform similarity,as a beat-to-beat index,is obtained by cross correlation between two ECG cycles with high precision but heavy computation.Slope-based method dispenses with QRS detection and is very simple and real-time,but its sensitivity is lower than similarity-based method and it only get statistical data.Conclusion Both morphology similarity and slope character algorithms could provide objective estimation of ECG quality.Slope-based method is an attractive measure due to its simplicity and mathematical convenience,while similarity-based method is more accurate and robust for ECG quality assessment.
9.Expression and action mechanism of stromal cell-derived factor 1 in tendon-bone healing of rabbit rotator cuff
Xu WANG ; Yajie WU ; Xinfu ZHANG ; Zhi SHI ; Tengyun YANG ; Bohan XIONG ; Xiaojun LU ; Daohong ZHAO
Chinese Journal of Tissue Engineering Research 2024;28(19):3049-3054
BACKGROUND:In recent years,some scholars in the field of tendon bone injury have attached stromal cell-derived factor 1 to tissue engineering scaffolds to promote tendon bone healing,and achieved good results.However,whether stromal cell-derived factor 1 promotes tendon bone healing mechanisms and participates in the repair of natural healing has not yet been defined. OBJECTIVE:To study the expression of stroma-cell derived factor 1 during tendon bone healing after rupture of the whole supraspinatus muscle of the rabbit rotator cuff and its migration effect and optimal in vitro migration promoting concentration on stem cells during tendon bone injury. METHODS:Totally 18 adult New Zealand rabbits were randomly selected to establish rotator cuff injury models,and an additional 3 rabbits were selected as blank controls.At 3,5,7,14,21,and 28 days after modeling,three rabbits were executed separately and the rabbits in the blank group were sacrificed.The tissues of tendon bone junction were taken and stored in a-80℃refrigerator.The expression of stromal cell-derived factor 1 was detected by ELISA at each time point after injury.Mesenchymal stem cells were isolated from the bone marrow of young rabbit femur,cultured,and identified.Transwell assay was performed to verify the migration-promoting effect of stromal cell-derived factor 1 on stem cells and the optimal migration-promoting concentration in vitro.The stem cells cultured to P3 were co-cultured with BrdU and injected into the rabbit ear marginal vein,and immunohistochemical staining was used to verify whether the stem cells migrated to the injury site. RESULTS AND CONCLUSION:(1)Stromal cell-derived factor 1 gene expression was bimodal during rotator cuff tendon bone healing.Stromal cell-derived factor 1 gene expression increased significantly at 3 days post-injury(P<0.01)and then decreased,reaching a minimum at 5 days post-injury.It increased again and reached a peak 14 days after injury(P<0.01)and then decreased.(2)Cell immunohistochemical staining displayed that stem cells labeled with BrdU did migrate to the injury site.(3)The results of the transwell experiment exhibited that 60-80 ng/mL stromal cell-derived factor 1 had the best effect on promoting migration of stem cells,while a concentration of 200 ng/mL inhibited migration.(4)Stromal cell-derived factor 1 is involved in the healing of rotator cuff tendon bone during the inflammatory response phase and the proliferation phase.The mechanism of action may be to promote the migration of stem cells to the injury and their differentiation into various types of cells to promote repair.In addition,the pro-migration effect of stromal cell-derived factor 1 exists at a range of concentrations,beyond which it may act as an inhibitor.
10.Associations of Serum Isoleucine with Mild Cognitive Impairment and Alzheimer’s Disease
Xiao-jun JING ; Zhi-yuan ZAN ; Xin ZHOU ; Yong-lan XIONG ; Shu-jiang REN ; Hua ZHANG ;
Annals of Geriatric Medicine and Research 2024;28(3):273-283
Background:
Advances in blood biomarker discovery have enabled the improved diagnosis and prognosis of Alzheimer's disease (AD). Most branched-chain amino acids, except isoleucine (Ile), are correlated with both mild cognitive impairment (MCI) and AD. Therefore, this study investigated the association between serum Ile levels and MCI/AD.
Methods:
This study stratified 700 participants from the Alzheimer's Disease Neuroimaging Initiative database into four diagnostic groups: cognitively normal, stable MCI, progressive MCI, and AD. Analysis of covariance and chi-square analyses were used to test the demographic data. Receiver operating curve analyses were used to calculate the diagnostic accuracy of different biomarkers and were compared by MedCalc 20. Additionally, Cox proportional hazards models were used to measure the ability of serum Ile levels to predict disease conversion. Finally, a linear mixed-effects model was used to evaluate the associations between serum Ile levels and cognition, brain structure, and metabolism.
Results:
Serum Ile concentration was decreased in AD and demonstrated significant diagnostic efficacy. The combination of serum Ile and cerebrospinal fluid (CSF) phosphorylated tau (P-tau) improved the diagnostic accuracy in AD compared to total tau (T-tau) alone. Serum Ile levels significantly predicted the conversion from MCI to AD (cutoff value of 78.3 μM). Finally, the results of this study also revealed a correlation between serum Ile levels and the Alzheimer's Disease Assessment Scale cognitive subscale Q4.
Conclusions
Serum Ile may be a potential biomarker of AD. Ile had independent diagnostic efficacy and significantly improved the diagnostic accuracy of CSF P-tau in AD. MCI patients with a lower serum Ile level had a higher risk of progression to AD and a worse cognition assessment.


Result Analysis
Print
Save
E-mail