1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.FLASH Interacts with Promyelocytic Leukemia Protein Ⅳ(PML Ⅳ)and Enhances the SUMOylation of p53
Meng-Ni WANG ; Zhen-Zhen XIONG ; Zhi-Ying WANG ; Jian-Hua WU ; Xiao-Zhong SHI
Chinese Journal of Biochemistry and Molecular Biology 2024;40(10):1426-1440
As a unique gene in the genome,FLASH(FADD-like interleukin-1β-converting enzyme asso-ciated huge protein)/CASP8AP2 is involved in multiple cellular processes,including apoptosis,histone gene pre-mRNA processing,transcriptional regulation,and cell cycle progression.Clinical studies have shown that FLASH is a valuable prognostic marker for acute lymphoblastic leukemia,and a crucial factor for the survival of various cancer cells.Therefore,in-depth research into the function of FLASH may offer new perspectives for the treatment of related diseases.Our previous research identified FLASH as a bind-ing partner of p53,demonstrating that FLASH enhances the transcriptional activity of p53.Here we fur-ther investigate the molecular mechanisms of the interaction between FLASH and p53,revealing that the p53-K386R mutation(SUMOylation residue)attenuated its interaction with FLASH(aa 51-200)and FLASH-SIM(SUMO-interacting motif)(aa 1 534-1 806)significantly.However,SUMO can bind to FLASH-SIM directly,instead of FLASH(aa 51-200).Subsequent research shows that overexpression of FLASH in cells enhances global SUMO1 conjugation and p53-SUMO1 conjugation,therefore providing a plausible explanation for the underlying mechanism of FLASH enhancing the transcriptional activity of p53.Since promyelocytic leukemia protein nuclear body(PML NB)serves as subcellular reactors for SUMO conjugation within the cell,and the PML Ⅳ isoform can specifically enhance the SUMO modifica-tion of p53,we have investigated the interaction between FLASH and PML Ⅳ,and elucidated the struc-tural basis of their interaction:both FLASH-N3A(501-802)and FLASH-C2(1 807-1 981)bind to PML Ⅳ(aa 228-633).Further investigations reveal that they can synergistically enhance global SUMO1 modification as well as SUMO1 modification of p53.The interaction between FLASH and tumor suppres-sors p53 or PML Ⅳ enriches our understanding of its function and reveals the potential mechanism of FLASH in tumor development,therefore offering novel insights into cancer diagnosis and treatment.
7.Application value of ultrasound technology in transurethral enucleation and resection of the prostate
Yu XIONG ; Feng-Feng LU ; Qi JIANG ; Zhen-Qian SONG ; Xiao-Feng ZHU ; Ze-Peng ZHU ; Zhi-Feng WEI ; Ai-Bing YAO
National Journal of Andrology 2024;30(4):300-305
Objective:To investigate the application value of ultrasound technology in transurethral enucleation and resection of the prostate(TUERP).Methods:This study included 78 BPH patients admitted in our hospital from June 2021 to June 2023,aged 70.68±8.63 years and with the indication of surgery.We randomly divided them into two groups to receive TUERP(the control group,n=39)and ultrasound-assisted TUERP(the US-TUERP group,n=39).We statistically analyzed and compared the rele-vant parameters obtained before and after operation between the two groups.Results:No statistically significant differences were ob-served in the operation time and bladder irrigation time between the two groups(P>0.05).More glandular tissues were removed but less intraoperative bleeding and fewer perioperative complications occurred in the US-TUERP group than in the control.Compared with the baseline,IPSS,postvoid residual urine volume(PVR),quality of life score(QOL)and maximum urinary flow rate(Qmax)were significantly improved in both groups at 1 and 3 months after surgery,even more significantly in the US-TUERP than in the control group(P<0.05).Conclusion:US-TUERP helps achieve complete resection of the hyperplastic prostatic tissue along the surgical capsule at the anatomical level,with a higher safety,fewer perioperative complications,and better therapeutic effects.
8.Application of China-made Toumai? Robot in laparoscopic radical prostatectomy
Zhi-Feng WEI ; Yu-Hao CHEN ; Ze-Peng ZHU ; Qi JIANG ; Yu XIONG ; Feng-Feng LU ; Zhen-Qian SONG ; Bin JIANG ; Xiao-Feng ZHU ; Tian-Hao FENG ; Xiao-Feng XU ; Gang YANG ; Wu WEI ; Ai-Bing YAO ; Jing-Ping GE
National Journal of Andrology 2024;30(8):696-700
Objective:To evaluate the safety and efficiency of China-made Toumai Robot-assisted laparoscopic radical prosta-tectomy(LRP).Methods:This study included 40 cases of PCa treated from January 2023 to May 2023 by robot-assisted LRP with preservation of the bladder neck and maximal functional urethral length,15 cases with the assistance of Toumai Robot(the TMR group)and the other 25 with the assistance of da Vinci Robot as controls(the DVR group).We recorded the docking time,laparo-scopic surgery time,vesico-urethral anastomosis time,intraoperative blood loss and postoperative urinary continence,and compared them between the two groups.Results:Operations were successfully completed in all the cases.No statistically significant differ-ences were observed between the TMR and DVR groups in the docking time(6 min vs 5 min,P>0.05)or intraoperative blood loss(200 ml vs 150 ml,P>0.05).The TMR group,compared with the DVR group,showed a significantly longer median laparoscopic surgery time(146 min vs 130 min,P<0.05)and median vesico-urethral anastomosis time(19 min vs 16 min,P<0.05).There were no statistically significant differences between the TMR and DVR groups in the rates of urinary continence recovery immediately af-ter surgery(60.0%[9/15]vs 64.0%[16/25],P>0.05)or at 1 month(80.0%[12/15])vs(76.0%[19/25],P>0.05),3 months(93.3%[14/15])vs(92.0%[23/25],P>0.05)and 6 months postoperatively(100%[15/15])vs(96%[24/25],P>0.05).Conclusion:China-made Toumai? Robot surgical system is safe and reliable for laparoscopic radical prosta-tectomy,with satisfactory postoperative recovery of urinary continence.
9.Modified scrotoscopic surgery for testicular hydrocele
Tian-Hao FENG ; Ai-Bing YAO ; Qi JIANG ; Xiao-Feng ZHU ; Yu XIONG ; Zhen-Qian SONG ; Feng-Feng LU ; Bin JIANG ; Zhi-Feng WEI
National Journal of Andrology 2024;30(10):910-914
Objective:To explore the application of modified scrotoscopic surgery(MSS)in the treatment of testicular hydro-cele.Methods:We selected 45 cases of testicular hydrocele for this study,22 treated by traditional scrotoscopic surgery(TSS)and the other 23 by MSS,which was performed with a pin-shaped electrode bent inward at an angle of 60° instead of a circular electrode used in TSS.We recorded the general clinical data,operation time,incision length,intraoperative injury,incision infection,scrotal e-dema,postoperative hospital stay and postoperative Visual Analogue Scale(VAS)scores of the patients and compared them between the two groups.Results:There was no statistically significant difference in the general clinical data between the two groups(P>0.05).Compared with the patients of the TSS group,those of the MSS group showed significantly shorter operative time([32.86±3.80]vs[26.13±2.81]min,P<0.05),incision length([14.09±2.23]vs[8.73±1.48]mm,P<0.05)and postopera-tive hospital stay([4.36±1.05]vs[2.00±0.90]d,P<0.05),and achieved remarkably lower VAS scores on postoperative days 1(4.41±1.05 vs 3.09±0.79,P<0.05),2(3.36±1.05 vs 2.78±1.13,P<0.05),3(2.65±0.72 vs 1.74±0.86,P<0.05)and 7(1.91±0.81 vs 1.04±0.82,P<0.05).At 3 and 7 days after surgery,scrotal edema was markedly mil-der in the MSS than in the TSS group(P<0.05).No testicular or epididymal damage,or wound infection occurred in either of the two groups.Conclusion:MSS is safe and effective in the treatment of testicular hydrocele,superior to TSS for its advantages of shorter operation time,smaller surgical incision,less postoperative pain and milder scrotal edema.
10.Effect and mechanism of pachymic acid on renal function and fibrosis in rats with chronic renal failure
Bin PENG ; Xue FENG ; Li FENG ; Wei XIONG ; Xi HU ; Shuangyi ZHU ; Yang XIAO ; Fang CHEN ; Zhi GAO
China Pharmacy 2024;35(12):1489-1494
OBJECTIVE To investigate the effect of pachymic acid (PA) on renal function and fibrosis in chronic renal failure (CRF) rats and its potential mechanism based on the Ras homolog gene family member A (RhoA)/Rho-associated coiled-coil forming protein kinase (ROCK) signaling pathway. METHODS Using male SD rats as subjects, the CRF model was established by 5/6 nephrectomy; the successfully modeled rats were divided into model group, PA low-dose, medium-dose and high-dose groups (5, 10, 20 mg/kg PA), high-dose PA+ROCK pathway activator lysophosphatidic acid (LPA) group (20 mg/kg PA+1 mg/kg LPA), with 15 rats in each group. Another 15 rats were selected as the sham operation group with only the kidney exposed but not excised. The rats in each drug group were gavaged and/or injected with the corresponding liquid via the caudal vein, once a day, for 12 consecutive weeks. During the experiment, the general condition of rats was observed in each group. After the last administration, the serum renal function indexes (blood urea nitrogen, serum creatinine, uric acid) of rats in each group were detected, the renal histopathological changes were observed; the renal tubule injury score and the area of renal fibrosis were quantified. The levels of oxidative stress indexes [malondialdehyde (MDA), superoxide dismutase (SOD)] and inflammatory factors (tumor necrosis factor-α, interleukin-1β, interleukin-6), the positive expression rates of connective tissue growth factor (CTGF) and collagen Ⅰ were detected as well as the expression levels of pathway-related proteins (RhoA, ROCK1) and fibrosis- related proteins (transforming growth factor-β1, bare corneum homologs 2, α-smooth muscle actin) were determined. RESULTS Compared with the sham operation group, the rats in model group had reduced diet, smaller body size, listless spirit and sluggish response, reduced and atrophied glomeruli, dilated renal tubules with chaotic structure, and a large number of inflammatory cells infiltrated interstitium; the serum levels of renal function indexes, renal tubule injury score, renal fibrosis area proportion, the levels of MDA and inflammatory factors, the positive expression rates of CTGF and collagen Ⅰ, and the expression levels of pathway-related proteins and fibrosis-related proteins in renal tissues were significantly increased, while SOD level was significantly decreased (P<0.05). Compared with the model group, the general condition and pathological injuries of kidney tissue of rats in PA groups were improved to varying degrees,and the above quantitative indexes were significantly improved in a dose-dependent manner (P<0.05). LPA could significantly reverse the improvement effect of PA on the above indicators (P<0.05). CONCLUSIONS PA can improve renal function and alleviate renal fibrosis in CRF rats, which may be related to inhibiting the activation of RhoA/ROCK signaling pathway.

Result Analysis
Print
Save
E-mail