1.Yimei Baijiang Formula Treats Colitis-associated Colorectal Cancer in Mice via NF-κB Signaling Pathway
Qian WU ; Xin ZOU ; Chaoli JIANG ; Long ZHAO ; Hui CHEN ; Li LI ; Zhi LI ; Jianqin LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):119-130
ObjectiveTo explore the effects of Yimei Baijiang formula (YMBJF) on colitis-associated colorectal cancer (CAC) and the nuclear factor kappaB (NF-κB) signaling pathway in mice. MethodsSixty male Balb/c mice of 4-6 weeks old were randomized into 6 groups: Normal, model, capecitabine (0.83 g
2.Yimei Baijiang Formula Treats Colitis-associated Colorectal Cancer in Mice via NF-κB Signaling Pathway
Qian WU ; Xin ZOU ; Chaoli JIANG ; Long ZHAO ; Hui CHEN ; Li LI ; Zhi LI ; Jianqin LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):119-130
ObjectiveTo explore the effects of Yimei Baijiang formula (YMBJF) on colitis-associated colorectal cancer (CAC) and the nuclear factor kappaB (NF-κB) signaling pathway in mice. MethodsSixty male Balb/c mice of 4-6 weeks old were randomized into 6 groups: Normal, model, capecitabine (0.83 g
3.Guidelines for the perioperative diagnosis and treatment of oncogene-driven non-small cell lung cancer (2026)
Weidong WANG ; Yongbin LIN ; Hui TIAN ; Gaofeng LI ; Shun XU ; Yongde LIAO ; Haitao MA ; Junfeng LIU ; Chundong GU ; Xiaolong YAN ; Shumin WANG ; Daqiang SUN ; Jianyang LIU ; Tao XUE ; Shaohua MA ; Zhigang LI ; Shuanghu YUAN ; Gen LIN ; Ling CAI ; Jianping ZHOU ; Wenzhao ZHONG ; Naixin LIANG ; Yi HAN ; Junfeng WANG ; Weidong ZHANG ; Xin WANG ; Lianjuan CHEN ; Lunxu LIU ; Xiuyi ZHI ; Lanjun ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(09):1337-1353
Lung cancer constitutes the most prevalent and lethal malignant tumor in China. Approximately 85% of lung cancer diagnoses correspond to the non-small cell histological subtype [non-small cell lung cancer (NSCLC)]. Despite surgery being the mainstay for early-stage disease, postoperative recurrence remains high and adjuvant chemotherapy offers limited benefit. In recent years, targeted therapy has demonstrated substantial advantages in driver mutation-positive NSCLC. To this end, the Lung Cancer Medical Education Committee of the Chinese Medical Education Association developed guidelines based on a systematic review of evidence through November 2025, using the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach and a modified Delphi method. Focusing on epidermal growth factor receptor (EGFR) and anaplastic lymphoma kinase (ALK), and addressing ROS proto-oncogene 1 (ROS1), B-Raf proto-oncogene serine/threonine kinase (BRAF) V600E mutation, and mesenchymal-epithelial transition factor (MET) exon 14 (METex14) skipping, the guideline covers molecular testing, neoadjuvant/adjuvant therapy, perioperative strategies, minimal residual disease monitoring, and postoperative surveillance. It defines testing requirements, specifies stage-directed and subtype-specific treatments, and standardizes minimal residual disease monitoring. These recommendations emphasize precision and feasibility to improve survival and quality of life.
4.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
5.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
6.Feasibility and exploration of optimal communication models for robot-assisted urological telesurgery: a multicenter, single-arm, retrospective study
Ye WANG ; Taoping SHI ; Sheng TAI ; Sunyi YE ; Yubai ZHANG ; Bingzhang QIAO ; Chenfeng WANG ; Gen CHENG ; Zhi LI ; Qing AI ; Qingbo HUANG ; Baojun WANG ; Qing YUAN ; Junnan XU ; Guojun LIU ; Yu CHEN ; Wuyi ZHAO ; Jianle MAO ; Shiwei LI ; Shuo WANG ; Dan XIA ; Wanhai XU ; Chaozhao LIANG ; Hongzhao LI ; Xin MA ; Xu ZHANG
Chinese Journal of Urology 2025;46(5):331-336
Objective:To evaluate the efficacy and feasibility of a domestically developed robotic surgical system based on fiber-optic dedicated line communication in cross-regional urological telesurgery.Methods:This was multicenter,single-arm,retrospective case series study. The data of patients who underwent urological telesurgeries using the telesurgical system between January 2023 and December 2024 were analyzed. The cohort included 59 patients from seven hospitals across China. Among the patients,47 were male(79.7%)and 12 were female(20.3%),with a median age of 63.0(56.0,68.0)years and a body mass index of(24.7 ± 3.0)kg/m 2. Surgical procedures included 32 radical prostatectomies,24 partial nephrectomies,one radical nephrectomy,one adrenalectomy,and one ureteral reconstruction. The perioperative indicators,pathological results and postoperative complications were analyzed. The network monitoring data were collected,and the perioperative data of patients,remote system monitoring data and costs were compared between the two communication modes of optical transport network(OTN)and cloud-connect network(CCN). Results:All 59 remote surgeries were successfully completed,with a mean operative time of(138.0 ± 54.0)minutes,median intraoperative blood loss of 50.0(30.0,100.0)ml and a postoperative hospital stay of 5.0(4.0,6.0)days. No cases required reoperation,Clavien-Dindo grade ≥3 complications,or readmission. The geographical distance between the primary and remote surgical sites ranged from 450 to 2 800 km. Network monitoring revealed increased bidirectional latency with distance increasing:the shortest latency time(Hefei-Hangzhou,450 km)was(16.59 ± 0.80)ms,while the longest(Harbin-Hangzhou,2 200 km)latency time was(53.31 ± 0.31)ms. Average frame loss per procedure was 0?1.27 frames. The results of subgroup analysis comparing OTN and CCN communication modes showed no significant differences in operative time[(130.7 ± 70.5)minutes vs.(142.1 ± 42.9)minutes, P = 0.442],postoperative hospitalization[6.0(4.0,8.0)d vs. 5.0(4.0,6.0)d, P = 0.581],or readmission rates(0 vs. 0). However,CCN demonstrated significant cost advantages with 500 RMB per operation vs. 3 000 RMB per operation for OTN. Conclusions:Urological telesurgery using fiber-optic communication is feasible. The CCN mode,with its cost-effectiveness,excellent usability,and multi-point interconnection flexibility,is currently the preferred communication model for telesurgical applications.
7.A multicenter clinical study on intramedullary vancomycin injection for preventing periprosthetic joint infection in total knee arthroplasty
Te LIU ; Jun FU ; Shiguang LAI ; Zhuo ZHANG ; Chi XU ; Lei GENG ; Yang LUO ; Peng REN ; Xin ZHI ; Quanbo JI ; Heng ZHANG ; Runkai ZHAO ; Haichao REN ; Ye TAO ; Qingyuan ZHENG ; Zeyu FENG ; Jianfeng YANG ; Yiming WANG ; Pengcheng LI ; Shuai LIU ; Wei CHAI ; Xiang LI ; Huiwu LI ; Xiaogang ZHANG ; Baochao JI ; Xianzhe LIU ; Xinzhan MAO ; Jianbing MA ; Xiangxiang SUN ; Jiying CHEN ; Yonggang ZHOU ; Jinliang WANG ; Weijun WANG ; Guoqiang ZHANG ; Ming NI
Chinese Journal of Orthopaedics 2025;45(12):803-811
Objective:To explore the safety and efficacy of intraosseous regional administration (IORA) of vancomycin for preventing infection in primary total knee arthroplasty (TKA).Methods:A total of 124 patients with knee osteoarthritis undergoing TKA between February 2024 and May 2024 at nine hospitals were enrolled. Preoperative infection prophylaxis involved either IORA (0.5 g vancomycin administered via intraosseous regional infusion before incision) or intravenous infusion (1 g vancomycin via peripheral vein). The IORA group included 15 males and 47 females with a median age of 66.5 years (range, 60.0-70.0 years), while the intravenous group included 14 males and 48 females with a median age of 66.0 years (range, 61.8-70.3 years) years. Intraoperative samples were collected including fat and synovium tissues after incision, before prosthesis placement, and after tourniquet release; distal femoral cancellous bone during femoral osteotomy; proximal tibial cancellous bone during tibial osteotomy; proximal intercondylar cancellous bone before prosthesis placement; and peripheral blood from non-infused arms at surgery initiation and after tourniquet release. Vancomycin concentrations were measured using liquid chromatography-tandem mass spectrometry. Vital sign changes were recorded from admission to 5~10 minutes post-IORA (IORA group) or post-incision (intravenous group). Follow-ups were conducted on postoperative day 1 and 3, and at 1 and 3 months, to document complications including IORA-related adverse events, periprosthetic joint infections, surgical site infections, red man syndrome, acute kidney injury, deep vein thrombosis and so on.Results:Vancomycin concentrations in bone, fat, and synovial tissue samples were significantly higher in the IORA group than in the intravenous group ( P<0.05), while vancomycin concentrations in blood samples were significantly lower in the IORA group than in the intravenous group ( P<0.05). Only 7.3%(41/558) of tissue samples in the IORA group had vancomycin concentrations below 2.0 μg/g (the minimum inhibitory concentration of vancomycin against coagulase-negative staphylococcus), compared to 59.3%(331/558) in the intravenous group (χ 2=11.285, P<0.001). In the intravenous group, 16.9%(21/124) of blood samples had vancomycin concentrations exceeding 15.0 mg/L (the threshold associated with a significantly increased risk of nephrotoxicity), while all concentrations in the IORA group were below this threshold, the difference was statistically significant (χ 2=22.943, P<0.001). There were no statistically significant difference ( P>0.05) in vital signs changes before and after vancomycin administration between the two groups. Two patients in the intravenous group experienced incision exudate, while no other related complications occurred in either group. Conclusions:Compared to the traditional intravenous infusion of 1 g vancomycin, intraosseous injection of a low dose (0.5 g) of vancomycin achieves higher local tissue concentrations in the knee joint with a lower incidence of adverse reactions and is safe for infection prophylaxis. Despite guidelines not recommending the routine use of vancomycin for preventing infection after primary TKA, intraosseous injection of 0.5 g vancomycin may be considered intraoperatively for primary TKA in the following scenarios: patients in medical institutions with a high prevalence of methicillin-resistant staphylococcus aureus (MRSA) infections, patients with potential preoperative MRSA colonization, or patients with cephalosporin allergy.
8.A Micro Gas Chromatographic Column with Large Surface Area Based on Anodization
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Bo-Xin CHEN ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(10):1607-1614
A micro gas chromatographic column with mesoporous surface micro column array prepared by anodization method was proposed.A porous support layer with a characteristic pore size of about 30 nm inside the chromatographic column was prepared in situ using anodization method,and a uniform alumina stationary phase was deposited on the mesoporous support layer using atom layer deposition(ALD)technique.The existence of a mesoporous support layer increased surface area of the chromatographic column,thereby increasing the total amount of stationary phase loading and enhancing column capacity,which facilitated chromatographic separation.The test results showed that the porous support layer significantly reduced the longitudinal molecular diffusion and mass transfer resistance of the micro gas chromatographic column,and significantly increased the number of theoretical plates(n-nonane increased by 290.2%).Furthermore,column efficiency of the chromatographic column was less affected by flow rate,which was conducive to rapid separation of heavy hydrocarbon mixtures.
9.Creation and Exploration of the"Organized Fill-in-the-Blank Format"Disci-pline Construction Model for Forensic Medicine in the New Era
Zhi-Wen WEI ; Hong-Xing WANG ; Jun-Hong SUN ; Hao-Liang FAN ; Hong-Liang SU ; Le-Le WANG ; Wen-Ting HE ; Zhe CHEN ; Jie ZHANG ; Xiang-Jie GUO ; Ji LI ; Geng-Qian ZHANG ; Xin-Hua LIANG ; Jiang-Wei YAN ; Qiang-Qiang ZHANG ; Cai-Rong GAO ; Ying-Yuan WANG ; Hong-Wei WANG ; Jun XIE ; Bo-Feng ZHU ; Ke-Ming YUN
Journal of Forensic Medicine 2025;41(1):25-29
Forensic medicine has been designated as a first-level discipline,presenting new opportunities and challenges for the development of forensic medicine.Since the 1980s,the establishment of foren-sic medicine discipline and the cultivation of high-level forensic talents have become hot topics in the development of forensic medicine in China.Since the 13th Five-Year Plan,the forensic team of Shanxi Medical University has been aiming at the forefront,proposing the development goals of"Five First-class"and the discipline development path"Six Major Achievements".It has selected benchmark disci-plines,identified gaps in disciplinary development,unified thoughts,formulated completion timelines,concentrated superior resources,assigned tasks to individuals,and created an"Organized Fill-in-the-Blank Format"forensic medicine discipline construction model with the characteristics of the new era.The construction model of forensic medicine has achieved good results in the goals,discipline frame-work,scientific research,talent cultivation,discipline team and platform construction,forming a rela-tively complete discipline construction and management system,and accumulating valuable experience for the construction of first-level discipline and high-level talent cultivation of forensic medicine.
10.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.

Result Analysis
Print
Save
E-mail