1.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
2.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
3.Design of electric ice blanket system for early treatment of heat stroke disease
Bo-wen YAN ; Yan-yi LU ; Lin ZENG ; Zhi-gang ZHANG ; Nan XIAO ; Qing-hua HE
Chinese Medical Equipment Journal 2025;46(9):16-21
Objective To design an electric ice blanket system for prehospital emergency care of patients of heat sroke disease.Methods The electric ice blanket system consisted of a cooling host and cooling accessories.The cooling host had its chassis made of acrylonitrile-butadiene-styrene(ABS),which was equipped externally with an lithium battery and a DC power adapter,and integrated internally a cooling system,an internal circulation pump,an external circulation pump and a main control system;the cooling accessories included a cooling blanket,a cooling cap and a cooling vest,which had the inner layer made of thermoplastic polyurethane(TPU)elastomer and the outer layer made of Oxford cloth or polyester fiber.The system was compared with the existing subcooling therapeutic apparatus on the market in terms of cooling effect with a water bag simulation cooling experiment.Results The cooling experiment showed that the system was comparable to the existing subcooling therapeutic apparatus on the market in terms of cooling effect while behaved well in size and weight.Conclusion The system developed has a high cooling effect and advantages in portability and compatibility to the environment without power supply,which can be used for the early treatment of patients of heat stroke disease.[Chinese Medical Equipment Journal,2025,46(9):16-21]
4.The interval of rescue treatment does not affect the efficacy and safety of Helicobacter pylori eradication: A prospective multicenter observational study.
Minjuan LIN ; Junnan HU ; Jing LIU ; Juan WANG ; Zhongxue HAN ; Xiaohong WANG ; Zhenzhen ZHAI ; Yanan YU ; Wenjie YUAN ; Wen ZHANG ; Zhi WANG ; Qingzhou KONG ; Boshen LIN ; Yuming DING ; Meng WAN ; Wenlin ZHANG ; Miao DUAN ; Shuyan ZENG ; Yueyue LI ; Xiuli ZUO ; Yanqing LI
Chinese Medical Journal 2025;138(12):1439-1446
BACKGROUND:
The effect of the interval between previous Helicobacter pylori (H. pylori) eradication and rescue treatment on therapeutic outcomes remains unknown. The aim of this study was to investigate the association between eradication rates and treatment interval durations in H. pylori infections.
METHODS:
This prospective observational study was conducted from December 2021 to February 2023 at six tertiary hospitals in Shandong, China. We recruited patients who were positive for H. pylori infection and required rescue treatment. Demographic information, previous times of eradication therapy, last eradication therapy date, and history of antibiotic use data were collected. The patients were divided into four groups based on the rescue treatment interval length: Group A, ≥4 weeks and ≤3 months; Group B, >3 and ≤6 months; Group C, >6 and ≤12 months; and Group D, >12 months. The primary outcome was the eradication rate of H. pylori . Drug compliance and adverse events (AEs) were also assessed. Pearson's χ2 test or Fisher's exact test was used to compare eradication rates between groups.
RESULTS:
A total of 670 patients were enrolled in this study. The intention-to-treat (ITT) eradication rates were 88.3% (158/179) in Group A, 89.6% (120/134) in Group B, 89.1% (123/138) in Group C, and 87.7% (192/219) in Group D. The per-protocol (PP) eradication rates were 92.9% (156/168) in Group A, 94.5% (120/127) in Group B, 94.5% (121/128) in Group C, and 93.6% (190/203) in Group D. There was no statistically significant difference in the eradication rates between groups in either the ITT ( P = 0.949) or PP analysis ( P = 0.921). No significant differences were observed in the incidence of AEs ( P = 0.934) or drug compliance ( P = 0.849) between groups.
CONCLUSION:
The interval duration of rescue treatment had no significant effect on H. pylori eradication rates or the incidence of AEs.
REGISTRATION
ClinicalTrials.gov , NCT05173493.
Humans
;
Helicobacter Infections/drug therapy*
;
Helicobacter pylori/pathogenicity*
;
Male
;
Female
;
Prospective Studies
;
Middle Aged
;
Anti-Bacterial Agents/adverse effects*
;
Adult
;
Aged
;
Treatment Outcome
;
Proton Pump Inhibitors/therapeutic use*
5.Mediating effect of sleep duration between depression symptoms and myopia in middle school students.
Wei DU ; Xu-Xiang YANG ; Ru-Shuang ZENG ; Chun-Yao ZHAO ; Zhi-Peng XIANG ; Yuan-Chun LI ; Jie-Song WANG ; Xiao-Hong SU ; Xiao LU ; Yu LI ; Jing WEN ; Dang HAN ; Qun DU ; Jia HE
Chinese Journal of Contemporary Pediatrics 2025;27(3):359-365
OBJECTIVES:
To explore the mediating role of sleep duration in the relationship between depression symptoms and myopia among middle school students.
METHODS:
This study was a cross-sectional research conducted using a stratified cluster random sampling method. A total of 1 728 middle school students were selected from two junior high schools and two senior high schools in certain urban areas and farms of the Xinjiang Production and Construction Corps. Questionnaire surveys and vision tests were conducted among the students. Spearman analysis was used to analyze the correlation between depression symptoms, sleep duration, and myopia. The Bootstrap method was employed to investigate the mediating effect of sleep duration between depression symptoms and myopia.
RESULTS:
The prevalence of myopia in the overall population was 74.02% (1 279/1 728), with an average sleep duration of (7.6±1.0) hours. The rate of insufficient sleep was 83.62% (1 445/1 728), and the proportion of students exhibiting depression symptoms was 25.29% (437/1 728). Correlation analysis showed significant negative correlations between visual acuity in both eyes and sleep duration with depressive emotions as measured by the Center for Epidemiologic Studies Depression Scale (with correlation coefficients of -0.064, -0.084, and -0.199 respectively; P<0.01), as well as with somatic symptoms and activities (with correlation coefficients of -0.104, -0.124, and -0.233 respectively; P<0.01) and interpersonal relationships (with correlation coefficients of -0.052, -0.059, and -0.071 respectively; P<0.05). The correlation coefficients for left and right eye visual acuity and sleep duration were 0.206 and 0.211 respectively (P<0.001). Sleep duration exhibited a mediating effect between depression symptoms and myopia (indirect effect=0.056, 95%CI: 0.029-0.088), with the mediating effect value for females (indirect effect=0.066, 95%CI: 0.024-0.119) being higher than that for males (indirect effect=0.042, 95%CI: 0.011-0.081).
CONCLUSIONS
Sleep duration serves as a partial mediator between depression symptoms and myopia in middle school students.
Humans
;
Myopia/etiology*
;
Male
;
Female
;
Depression/physiopathology*
;
Cross-Sectional Studies
;
Sleep
;
Adolescent
;
Students
;
Child
;
Time Factors
;
Sleep Duration
6.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
7.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
8.Design of electric ice blanket system for early treatment of heat stroke disease
Bo-wen YAN ; Yan-yi LU ; Lin ZENG ; Zhi-gang ZHANG ; Nan XIAO ; Qing-hua HE
Chinese Medical Equipment Journal 2025;46(9):16-21
Objective To design an electric ice blanket system for prehospital emergency care of patients of heat sroke disease.Methods The electric ice blanket system consisted of a cooling host and cooling accessories.The cooling host had its chassis made of acrylonitrile-butadiene-styrene(ABS),which was equipped externally with an lithium battery and a DC power adapter,and integrated internally a cooling system,an internal circulation pump,an external circulation pump and a main control system;the cooling accessories included a cooling blanket,a cooling cap and a cooling vest,which had the inner layer made of thermoplastic polyurethane(TPU)elastomer and the outer layer made of Oxford cloth or polyester fiber.The system was compared with the existing subcooling therapeutic apparatus on the market in terms of cooling effect with a water bag simulation cooling experiment.Results The cooling experiment showed that the system was comparable to the existing subcooling therapeutic apparatus on the market in terms of cooling effect while behaved well in size and weight.Conclusion The system developed has a high cooling effect and advantages in portability and compatibility to the environment without power supply,which can be used for the early treatment of patients of heat stroke disease.[Chinese Medical Equipment Journal,2025,46(9):16-21]
9.Immunotherapy of pancreatic cancer with triptolide combined with ginsenoside Rg3
Wen-wen ZHAO ; Ting-ting JIANG ; Zhi-rong WANG ; Yun-yun WANG ; Xiang-xiang WU ; Hua-hui ZENG
Acta Pharmaceutica Sinica 2024;59(6):1794-1803
Liposome was used as carrier to carry triptolide and ginsenoside Rg3 in the treatment of pancreatic cancer tumor mice. The effects of liposome on the levels of CD4+ and CD8+ microenvironmental immune factors of pancreatic cancer tumor were investigated, and the tumor inhibitory effect and safety were evaluated. In this study, Pan02 cells were used to construct a tumor-bearing C57BL/6 mouse model. After 14 days of treatment, the changes in tumor volume and body weight of tumor-bearing mice were observed. The results showed that the high and low doses of liposome had significant therapeutic effect on tumor volume in the model group (
10.Advances in crystal nucleation for amorphous drugs
Jie ZHANG ; Kang LI ; Zi-qing YANG ; Zi-han DING ; Sai-jun XIAO ; Zhi-ming YUE ; Li-mei CAI ; Jia-wen LI ; Ding KUANG ; Min-zhuo LIU ; Zhi-hong ZENG
Acta Pharmaceutica Sinica 2024;59(7):1962-1969
Amorphous solid dispersion (ASD) is one of the most effective formulation approaches to enhance the water solubility and oral bioavailability of poorly water-soluble drugs. However, maintenance of physical stability of amorphous drug is one of the main challenges in the development of ASD. Crystallization is a process of nucleation and crystal growth. The nucleation is the key factor that influences the physical stability of the ASD. However, a theoretical framework to describe the way to inhibit the nucleation of amorphous drug is not yet available. We reviewed the methods and theories of nucleation for amorphous drug. Meanwhile, we also summarized the research progress on the mechanism of additives influence on nucleation and environmental factors on nucleation. This review aims to enhance the better understanding mechanism of nucleation of amorphous drug and controlling over the crystal nucleation during the ASD formulation development.