1.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
2.Modeling of medical equipment requirements for helicopter evacuation and rescue team based on AnyLogic
Shuo TANG ; Mi LI ; Li HE ; Bang-Fu ZHOU ; Liang ZHOU ; Nan XIAO ; Zhi-Gang ZHANG
Chinese Medical Equipment Journal 2024;45(5):28-33
Objective To provide references for reasonable equipping of airborne medical equipment oriented to different tasks by constructing a medical equipment requirement model for the helicopter evacuation and rescue team.Methods Relevant basic data were collected and organized on time for routine and emergency medical treatment and elementary medical equipment requirements for types of medical treatment.AnyLogic multi-agent modeling was used to established a medical equipment requirement model for the helicopter evacuation and rescue team,with the casualty,equipment and medical personnel as the agent modules and the logical relationship-based access rules between the agents.An example was taken with a Z-8 helicopter transformed into an ambulance platform to transport the rescue team and casualties,in which a variety of evacuation tasks with multi combinations of light and serious casualties were simulated and the model developed was used to record and analyze the data on waiting time for medical treatment,completion rate,personnel utilization rate and equipment requirement during 100 times of simulation flight.Results The model developed could provide generalized medical equipment allocation programs for the helicopter evacuation and rescue team to complete a variety of evacuation tasks in terms of electronic device,treatment equipment,auxiliary instrument and medical consumables.Conclusion The model developed facilitates rational allocation of medical equipment for the helicopter evacuation and rescue team.[Chinese Medical Equipment Journal,2024,45(5):28-33]
3.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
4.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
5.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
6.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
7.Correlation Analysis of Molecularly-Defined Cortical Interneuron Populations with Morpho-Electric Properties in Layer V of Mouse Neocortex.
Jun-Wei CAO ; Xiao-Yi MAO ; Liang ZHU ; Zhi-Shuo ZHOU ; Shao-Na JIANG ; Lin-Yun LIU ; Shu-Qing ZHANG ; Yinghui FU ; Wen-Dong XU ; Yong-Chun YU
Neuroscience Bulletin 2023;39(7):1069-1086
Cortical interneurons can be categorized into distinct populations based on multiple modalities, including molecular signatures and morpho-electrical (M/E) properties. Recently, many transcriptomic signatures based on single-cell RNA-seq have been identified in cortical interneurons. However, whether different interneuron populations defined by transcriptomic signature expressions correspond to distinct M/E subtypes is still unknown. Here, we applied the Patch-PCR approach to simultaneously obtain the M/E properties and messenger RNA (mRNA) expression of >600 interneurons in layer V of the mouse somatosensory cortex (S1). Subsequently, we identified 11 M/E subtypes, 9 neurochemical cell populations (NCs), and 20 transcriptomic cell populations (TCs) in this cortical lamina. Further analysis revealed that cells in many NCs and TCs comprised several M/E types and were difficult to clearly distinguish morpho-electrically. A similar analysis of layer V interneurons of mouse primary visual cortex (V1) and motor cortex (M1) gave results largely comparable to S1. Comparison between S1, V1, and M1 suggested that, compared to V1, S1 interneurons were morpho-electrically more similar to M1. Our study reveals the presence of substantial M/E variations in cortical interneuron populations defined by molecular expression.
Mice
;
Animals
;
Neocortex/physiology*
;
Mice, Transgenic
;
Interneurons/physiology*
8.Comparison of Murraya exotica and Murraya paniculata by fingerprint analysis coupled with chemometrics and network pharmacology methods.
Hai-Zhen LIANG ; Zhi-Yong DU ; Shuo YUAN ; Meng-Qiu LU ; Jian-Yong XING ; Qing MA ; Zheng-Zhou HAN ; Peng-Fei TU ; Yong JIANG
Chinese Journal of Natural Medicines (English Ed.) 2021;19(9):713-720
There are two source plants for the traditional Chinese medicine Murrayae Folium et Cacumen (MFC) in Chinese Pharmacopoeia, i.e. Murraya exotica L. and M. paniculata (L.) Jack. Herein, a chemical comparison of M. exotica and M. paniculata by high performance liquid chromatography (HPLC) fingerprint analysis coupled with chemometrics and network pharmacology was performed. The main peaks in the fingerprints were identified by liquid chromatography coupled with ion trap/time-of-flight mass spectrometry (LC-IT-TOF-MS) and authenticated by references. The chemometrics results showed that the HPLC fingerprints of these two species were clearly divided into two categories using hierarchical cluster analysis (HCA) and principal component analysis (PCA), and a total of 13 significantly differentiated markers were screened out by orthogonal partial least squares-discriminant analysis (OPLS-DA). However, the following network pharmacology analysis showed that these discriminated markers were found to act via many common targets and metabolic pathways, indicating the possibly similar pharmacological effects and mechanisms for M. exotica and M. paniculata. The above results provide valuable evidence for the equivalent use of these two plants in clinical settings. Moreover, the chromatographic fingerprint analysis coupled with chemometrics and network pharmacology supplies an efficient approach for the comparative analysis of multi-source TCMs like MFC.
10.Investigation of Transdermal Constituents and Molecular Mechanism of Euodiae Fructus in Treatment of Diarrhea by Transdermal Drug Delivery Based on Integrated Pharmacology and UPLC-Q-TOF-MS
Jian-xin ZHOU ; Shuo SHEN ; Mao-bo DU ; Yu-jie LI ; Yi SUN ; Ai-ping HE ; Yao YAO ; Ming-shuo WANG ; Shu-zhi LIU ; Yong-qin YIN
Chinese Journal of Experimental Traditional Medical Formulae 2021;27(7):112-120
Objective:To identify the transdermal constituents of Euodiae Fructus and predict its molecular mechanism in treating diarrhea by transdermal drug delivery. Method:Ultra performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS) and integrated pharmacology methods were used. The rapid identification of transdermal constituents of Euodiae Fructus was realized by the means of comparison of reference substances, analysis of UNIFI system and mass spectrometry. On this basis, Integrative Pharmacology-based Research Platform of Traditional Chinese Medicine (TCMIP) v2.0, SymMap, DisGeNET databases and literature were used to collected potential targets of transdermal constituents of Euodiae Fructus and targets for diarrhea-related diseases. The disease targets and drug targets were topologically analyzed to obtain the core targets, which were used for the Gene Ontology (GO) function and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analysis. Finally, Cytoscape 3.6.0 was used to build up a network of transdermal constituents-core targets-key pathways. Result:A total of 19 chemical constituents were speculatively identified from Euodiae Fructus extract, including quinolone alkaloids, limonins, indole alkaloids, organic acids and sterols. A total of 174 core targets of Euodiae Fructus for treating diarrhea were obtained by a topology analysis, signaling pathways of inflammatory response, cell proliferation, nutrient regulation and energy metabolism, signal transduction, bacterial infection were obtained through the analysis of KEGG enrichment. Conclusion:In this study, the transdermal constituents of Euodiae Fructus are identified for the first time, they can participate in the regulation of intestinal inflammation, maintain the integrity of intestinal mucosa, repaire and adjust the metabolism of the body by acting on Rac protein family, phosphatidylinositol 3-kinase, cytochrome P450 enzymes and aldo-keto reductase, respectively. In general, the molecular mechanism of Euodiae Fructus in the treatment of diarrhea is preliminarily elucidated.

Result Analysis
Print
Save
E-mail