1.Interpretation of 2024 ESC guidelines for the management of elevated blood pressure and hypertension
Yu CHENG ; Yiheng ZHOU ; Yao LÜ ; ; Dongze LI ; Lidi LIU ; Peng ZHANG ; Rong YANG ; Yu JIA ; Rui ZENG ; Zhi WAN ; Xiaoyang LIAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(01):31-40
The European Society of Cardiology (ESC) released the "2024 ESC guidelines for the management of elevated blood pressure and hypertension" on August 30, 2024. This guideline updates the 2018 "Guidelines for the management of arterial hypertension." One notable update is the introduction of the concept of "elevated blood pressure" (120-139/70-89 mm Hg). Additionally, a new systolic blood pressure target range of 120-129 mm Hg has been proposed for most patients receiving antihypertensive treatment. The guideline also includes numerous additions or revisions in areas such as non-pharmacological interventions and device-based treatments for hypertension. This article interprets the guideline's recommendations on definition and classification of elevated blood pressure and hypertension, and cardiovascular disease risk assessment, diagnosing hypertension and investigating underlying causes, preventing and treating elevated blood pressure and hypertension. We provide a comparison interpretation with the 2018 "Guidelines for the management of arterial hypertension" and the "2017 ACC/AHA guideline on the prevention, detection, evaluation, and management of high blood pressure in adults."
2.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
3.A retrospective study of BRAF inhibitors and EGFR inhibitors combined with immune checkpoint inhibitors in patients with microsatellite stable, BRAF V600E mutated metastatic colorectal cancer
Zhi JI ; Jinguo MA ; Xia WANG ; Jiaqi XIN ; Lijun MA ; Yixuan WANG ; Nan ZHANG ; Chunyan ZENG ; Rui LIU
Chinese Journal of Oncology 2025;47(9):922-928
Objective:To explore the efficacy and safety of B-Raf proto-oncogene, serine/threonine kinase (BRAF) inhibitor and epidermal growth factor receptor (EGFR) inhibitor combined with immune checkpoint inhibitor in microsatellite stable (MSS) BRAF V600E metastatic colorectal cancer (mCRC) patients.Methods:The data and outcomes of mCRC patients with MSS BRAF V600E who received BRAF inhibitor, EGFR inhibitor combined with immune checkpoint inhibitor in Tianjin Medical University Cancer Hospital from May 2022 to April 2024 were retrospectively collected.Results:A total of 12 mCRC patients were included in this study, the objective response rate was 50.0%, the disease control rate was 66.7%, and the median disease control time of patients who achieved objective response was 8.0 months. The median progression-free survival was 6.8 months and the median overall survival was 8.4 months. Overall adverse reactions were controllable, the most common treatment-related adverse events were fatigue (8 cases), fever (5 cases), and rash (4 cases). There were no grade 4 adverse event, serious adverse event, and treatment-related death.Conclusion:BRAF inhibitor and EGFR inhibitor combined with immune checkpoint inhibitor show good efficacy and controllable safety in BRAF V600E mCRC patients.
4.A retrospective study of BRAF inhibitors and EGFR inhibitors combined with immune checkpoint inhibitors in patients with microsatellite stable, BRAF V600E mutated metastatic colorectal cancer
Zhi JI ; Jinguo MA ; Xia WANG ; Jiaqi XIN ; Lijun MA ; Yixuan WANG ; Nan ZHANG ; Chunyan ZENG ; Rui LIU
Chinese Journal of Oncology 2025;47(9):922-928
Objective:To explore the efficacy and safety of B-Raf proto-oncogene, serine/threonine kinase (BRAF) inhibitor and epidermal growth factor receptor (EGFR) inhibitor combined with immune checkpoint inhibitor in microsatellite stable (MSS) BRAF V600E metastatic colorectal cancer (mCRC) patients.Methods:The data and outcomes of mCRC patients with MSS BRAF V600E who received BRAF inhibitor, EGFR inhibitor combined with immune checkpoint inhibitor in Tianjin Medical University Cancer Hospital from May 2022 to April 2024 were retrospectively collected.Results:A total of 12 mCRC patients were included in this study, the objective response rate was 50.0%, the disease control rate was 66.7%, and the median disease control time of patients who achieved objective response was 8.0 months. The median progression-free survival was 6.8 months and the median overall survival was 8.4 months. Overall adverse reactions were controllable, the most common treatment-related adverse events were fatigue (8 cases), fever (5 cases), and rash (4 cases). There were no grade 4 adverse event, serious adverse event, and treatment-related death.Conclusion:BRAF inhibitor and EGFR inhibitor combined with immune checkpoint inhibitor show good efficacy and controllable safety in BRAF V600E mCRC patients.
5.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
6.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
7.A qualitative study on digital-intelligent equipment empowering"generalized"development of traditional Chinese medicine inspection
Chen ZHAO ; Aomeng ZHANG ; Zehui YE ; Jiaying LUO ; Qiang SHI ; Ying YU ; Xiaoyu ZHANG ; Yin JIANG ; Zhicong ZENG ; Fengxia LIN ; Yinghui JIN ; Xue XU ; Xiaowei ZHANG ; Liangzhen YOU ; Yipin FAN ; Dameng YU ; Shaoyang MEN ; Jian DU ; Rui XU ; Ruijin QIU ; Yingjie ZHI ; Zhineng CHEN ; Xuan ZHANG ; Hongcai SHANG
Journal of Beijing University of Traditional Chinese Medicine 2025;48(8):1052-1061
Objective This study investigated feasible cases and their significance in promoting the"generalized"development of inspection through digital-intelligent equipment.Methods A qualitative research approach was used,involving interviews conducted between February 2025 and March 2025 with experts in traditional Chinese medicine diagnostics,clinical research methodology,medical engineering integration,and related disciplines,using both online and offline methods.In accordance with the Consolidated Criteria for Reporting Qualitative Research,feasible cases involving the specific application of digital equipment in various parts of observation were collected through item enrichment.The significance of extending observation capabilities via these cases was analyzed,along with the overall implications of integrating digital technologies with traditional inspection method.Results Interviews were completed with 11 experts from domestic universities and research institutes in the fields of traditional Chinese medicine diagnosis,medical engineering integration,and related disciplines.A total of 78 feasible cases of digital-intelligent inspection were identified,along with 69 insights regarding the significance of enhancing the inspection capabilities.These insights were synthesized into two dimensions and 23 holistic meanings.The first dimension is to expand the scope of inspection,including obtaining internal environmental characteristics,observing external environmental characteristics,expanding thermodynamic characteristic data,and crossing time and space.The second dimension is to improve the quality of observation and diagnosis information collection and analysis,including 19 specific meanings,such as standardized collection environment,objective quantification,and refined observation.Conclusion Digital-intelligent equipment plays a significant role in expanding the scope of inspection content and achieving high-quality acquisition and analysis of extensive inspection information.These advancements extend and enrich the capabilities of traditional inspection method in traditional Chinese medicine.
8.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
9.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
10.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.

Result Analysis
Print
Save
E-mail