1.Association of CRP and interleukin-6 levels with cardiac function in patients with myocardial infarc-tion
Zhi-min ZHAO ; Yan LU ; Wan-qing WANG ; Wei-yang LI
Chinese Journal of cardiovascular Rehabilitation Medicine 2025;34(2):250-255
Objective:To investigate the levels of C reactive protein(CRP)and interleukin(IL)-6 in patients with myocardial infarction(MI)and their association with cardiac function.Methods:We enrolled 140 MI patients ad-mitted to Sanya Harbin Medical University Hongsen Hospital Co.,Ltd between January 2020 and December 2022,as MI group.According to coronary stenotic severity,they were divided into mild group(n=62),moderate group(n=41)and severe group(n=37),and 75 healthy individuals who underwent physical examination simultaneously were selected as control group.Serum CRP,IL-6,cardiac troponin Ⅰ(cTnⅠ)and creatine kinase isoenzyme MB(CK-MB)levels were measured by automatic biochemical analyzer,and left ventricular ejection fraction(LVEF)was assessed by echocardiography.Above-mentioned indexes were compared between MI group and control group,and among groups of different coronary disease severity.Pearson/Spearman correlation was used to analyze the asso-ciation of serum CRP and IL-6 levels with Gensini score,cTnⅠ,CK-MB levels,and LVEF in MI patients.Diag-nostic value of serum CRP and IL-6 levels for MI was analyzed by receiver operating characteristic(ROC)curve.Results:Compared with participants in control group,those in MI group had significant higher serum CRP,IL-6,cTnⅠ and CK-MB,and significant lower LVEF(P<0.001 all).Serum CRP,IL-6,cTnⅠ and CK-MB levels sig-nificantly increased,and LVEF significant decreased in the order of mild group,moderate group and severe group(P<0.01 all).Pearson/Spearman correlation analysis showed that serum CRP and IL-6 levels were positively cor-related with Gensini score,cTnⅠ,and CK-MB levels(r=0.496~0.646,P<0.001all),and negatively correlated with LVEF(r=-0.530,-0.572,P<0.001 all)in MI patients.ROC curve showed that the area under the curve(AUC)of CRP combined IL-6 diagnosing MI was 0.856(95%CI 0.802~0.900),which was significantly higher than those of CRP(AUC=0.770,95%CI 0.708~0.824)and IL-6(AUC=0.793,95%CI 0.733~0.845)alone(Z=3.295,2.877,P<0.01 all).Conclusion:Serum CRP and IL-6 levels rise in MI patients,and they are closely associated with increased severity of coronary artery disease and reduced cardiac function.
2.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
3.Association of CRP and interleukin-6 levels with cardiac function in patients with myocardial infarc-tion
Zhi-min ZHAO ; Yan LU ; Wan-qing WANG ; Wei-yang LI
Chinese Journal of cardiovascular Rehabilitation Medicine 2025;34(2):250-255
Objective:To investigate the levels of C reactive protein(CRP)and interleukin(IL)-6 in patients with myocardial infarction(MI)and their association with cardiac function.Methods:We enrolled 140 MI patients ad-mitted to Sanya Harbin Medical University Hongsen Hospital Co.,Ltd between January 2020 and December 2022,as MI group.According to coronary stenotic severity,they were divided into mild group(n=62),moderate group(n=41)and severe group(n=37),and 75 healthy individuals who underwent physical examination simultaneously were selected as control group.Serum CRP,IL-6,cardiac troponin Ⅰ(cTnⅠ)and creatine kinase isoenzyme MB(CK-MB)levels were measured by automatic biochemical analyzer,and left ventricular ejection fraction(LVEF)was assessed by echocardiography.Above-mentioned indexes were compared between MI group and control group,and among groups of different coronary disease severity.Pearson/Spearman correlation was used to analyze the asso-ciation of serum CRP and IL-6 levels with Gensini score,cTnⅠ,CK-MB levels,and LVEF in MI patients.Diag-nostic value of serum CRP and IL-6 levels for MI was analyzed by receiver operating characteristic(ROC)curve.Results:Compared with participants in control group,those in MI group had significant higher serum CRP,IL-6,cTnⅠ and CK-MB,and significant lower LVEF(P<0.001 all).Serum CRP,IL-6,cTnⅠ and CK-MB levels sig-nificantly increased,and LVEF significant decreased in the order of mild group,moderate group and severe group(P<0.01 all).Pearson/Spearman correlation analysis showed that serum CRP and IL-6 levels were positively cor-related with Gensini score,cTnⅠ,and CK-MB levels(r=0.496~0.646,P<0.001all),and negatively correlated with LVEF(r=-0.530,-0.572,P<0.001 all)in MI patients.ROC curve showed that the area under the curve(AUC)of CRP combined IL-6 diagnosing MI was 0.856(95%CI 0.802~0.900),which was significantly higher than those of CRP(AUC=0.770,95%CI 0.708~0.824)and IL-6(AUC=0.793,95%CI 0.733~0.845)alone(Z=3.295,2.877,P<0.01 all).Conclusion:Serum CRP and IL-6 levels rise in MI patients,and they are closely associated with increased severity of coronary artery disease and reduced cardiac function.
4.Effects of fangchinoline derivative LYY-32 on biological properties of BLM DNA helicase
Wang-ming ZHANG ; Qin-ying FENG ; Xiao-yu SONG ; Xin-zhong ZHOU ; Juan LU ; Wan-qing XIE ; Zhi-wen LAI ; Wei-dong PAN ; Jie-lin LIU
Chinese Pharmacological Bulletin 2025;41(9):1680-1686
Aim To investigate the effects of the fangchinoline derivative LYY-32 on the biological prop-erties of the BLM642-1290 DNA helicase,in order to lay a foundation for further research on its antitumor activity.Methods Fluorescence polarization assay,malachite green-phosphate and ammonium molybdate colorime-try,and fluorescein-labeled DNA gel electrophoresis experiments were conducted to study the effects of fangchinoline derivative LYY-32 on the DNA binding activity,ATPase activity,and DNA unwinding activity of BLM642-1290 DNA helicase.The effects of LYY-32 on the DNA unwinding activity of DNA helicase in cells were studied using fluorescent techniques and time-lapse microscopy.Ultraviolet spectral scanning was used to investigate the effects of LYY-32 on the confor-mation of the BLM642-1290 DNA helicase.Results At a concentration of 10 μmol·L-1,the inhibition rate of LYY-32 on BLM642-1290 DNA helicase binding to dsDNA was 53.17%.At a concentration of 5 μmol·L-1,the inhibition rate of LYY-32 on BLM642-1290 DNA helicase binding to ssDNA was 88.49%.The inhibition rate of LYY-32 on the ATPase activity of BLM642-1290 DNA he-licase was 89.3%at a concentration of 50 μmol·L-1.When the concentration of LYY-32 exceeded 5μmol·L-1,its inhibition rate on the DNA unwinding activity of BLM642-1290 DNA helicase was 100%.LYY-32 also significantly inhibited the DNA unwinding ac-tivity of DNA helicase in cells.However,LYY-32 had no effect on the conformation of BLM642-1290 DNA heli-case.Conclusion The DNA binding activity,AT-Pase activity,and DNA unwinding activity of BLM642-1290 DNA helicase could be significantly inhibi-ted by the fangchinoline derivative LYY-32.
5.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
6.Effects of fangchinoline derivative LYY-32 on biological properties of BLM DNA helicase
Wang-ming ZHANG ; Qin-ying FENG ; Xiao-yu SONG ; Xin-zhong ZHOU ; Juan LU ; Wan-qing XIE ; Zhi-wen LAI ; Wei-dong PAN ; Jie-lin LIU
Chinese Pharmacological Bulletin 2025;41(9):1680-1686
Aim To investigate the effects of the fangchinoline derivative LYY-32 on the biological prop-erties of the BLM642-1290 DNA helicase,in order to lay a foundation for further research on its antitumor activity.Methods Fluorescence polarization assay,malachite green-phosphate and ammonium molybdate colorime-try,and fluorescein-labeled DNA gel electrophoresis experiments were conducted to study the effects of fangchinoline derivative LYY-32 on the DNA binding activity,ATPase activity,and DNA unwinding activity of BLM642-1290 DNA helicase.The effects of LYY-32 on the DNA unwinding activity of DNA helicase in cells were studied using fluorescent techniques and time-lapse microscopy.Ultraviolet spectral scanning was used to investigate the effects of LYY-32 on the confor-mation of the BLM642-1290 DNA helicase.Results At a concentration of 10 μmol·L-1,the inhibition rate of LYY-32 on BLM642-1290 DNA helicase binding to dsDNA was 53.17%.At a concentration of 5 μmol·L-1,the inhibition rate of LYY-32 on BLM642-1290 DNA helicase binding to ssDNA was 88.49%.The inhibition rate of LYY-32 on the ATPase activity of BLM642-1290 DNA he-licase was 89.3%at a concentration of 50 μmol·L-1.When the concentration of LYY-32 exceeded 5μmol·L-1,its inhibition rate on the DNA unwinding activity of BLM642-1290 DNA helicase was 100%.LYY-32 also significantly inhibited the DNA unwinding ac-tivity of DNA helicase in cells.However,LYY-32 had no effect on the conformation of BLM642-1290 DNA heli-case.Conclusion The DNA binding activity,AT-Pase activity,and DNA unwinding activity of BLM642-1290 DNA helicase could be significantly inhibi-ted by the fangchinoline derivative LYY-32.
7.Rapid non-destructive detection technology for traditional Chinese medicine preparations based on machine learning: a review.
Xin-Hao WAN ; Qing TAO ; Zi-Qian WANG ; Dong-Yin YANG ; Zhi-Jian ZHONG ; Xiao-Rong LUO ; Ming YANG ; Xue-Cheng WANG ; Zhen-Feng WU
China Journal of Chinese Materia Medica 2024;49(24):6541-6548
In recent years, with the increasing societal focus on drug quality and safety, quality issues have become a major challenge faced by the pharmaceutical industry, directly impacting consumer health and market trust. By combining multispectral imaging technology with machine learning, it is possible to achieve rapid, non-destructive, and precise detection of traditional Chinese medicine(TCM) preparations, thereby revolutionizing traditional detection methods and developing more convenient and automated solutions. This paper provides a comprehensive review of the current applications of rapid, non-destructive detection techniques based on machine learning algorithms in the field of TCM preparations. It analyzed the principles and advantages of commonly used rapid, non-destructive detection techniques, offering a reference for the application and promotion of these technologies in TCM preparation detection. Additionally, this paper explored various data preprocessing techniques, operational processes, and machine learning algorithms to enhance data utilization efficiency. Finally, it focused on the challenges of applying machine learning in TCM preparation detection and offered corresponding recommendations, providing guidance for the future integration of machine learning with rapid, non-destructive detection techniques in practical production.
Machine Learning
;
Drugs, Chinese Herbal/analysis*
;
Medicine, Chinese Traditional/methods*
;
Humans
;
Quality Control
8.Determination of physical properties and calibration of discrete element simulation parameters for Jianwei Xiaoshi Granules.
Zi-Qian WANG ; Fan WU ; Zhi-Jian ZHONG ; Xiao-Rong LUO ; Xin-Hao WAN ; Jia-Li LIAO ; Qing TAO ; Zhen-Feng WU
China Journal of Chinese Materia Medica 2024;49(24):6558-6564
The construction method and simulation parameter settings for the discrete element model of Jianwei Xiaoshi Granules, as the primary material of Jianwei Xiaoshi Tablets, are not yet clear. The accuracy of the simulation model significantly influences the dynamic response characteristics between granules. Therefore, it is necessary to calibrate the parameters to improve the accuracy of the simulation parameters. Using the repose angle of Jianwei Xiaoshi Granules as the response value, the response surface methodology was employed to optimize and calibrate the discrete element parameters. Physical experiments were conducted to determine the physical properties of Jianwei Xiaoshi Granules. Based on the Hertz-Mindlin with Johnson-Kendall-Roberts(JKR) V2 model and virtual simulation methods, a repose angle determination model was constructed in EDEM software. The repose angle was measured using image analysis and numerical fitting methods. The Plackett-Burman experiment was used to screen the initial parameters for significance in the discrete element simulation. The significant parameters were then subjected to a steepest ascent experiment to determine the optimal parameter range. Furthermore, based on the Box-Behnken experiment, a second-order regression equation between significant parameters and repose angle was established, with the repose angle of 37.64° in the physical experiment as the target value. The regression equation was optimized and solved. The significance screening experiment revealed that the granule-granule static friction coefficient, granule-granule rolling friction, and granule-steel plate rolling friction of Jianwei Xiaoshi Granules significantly influenced the simulated repose angle. The optimal parameter combination was found to be 0.330, 0.222, and 0.229. The simulation results with this optimal parameter combination showed that there was no significant difference between the simulated repose angle and the repose angle obtained in the physical experiment, with a relative error of 0.05%, which further validated the reliability of the calibrated discrete element parameters for Jianwei Xiaoshi Granules.
Drugs, Chinese Herbal/chemistry*
;
Calibration
;
Computer Simulation
9.Identification of CMAs of Jianwei Xiaoshi Tablet granules based on QbD concept and construction of their predictive model.
Xin-Hao WAN ; Zhi-Jian ZHONG ; Qing TAO ; Zi-Qian WANG ; Jia-Li LIAO ; Dong-Yin YANG ; Ming YANG ; Xiao-Rong LUO ; Zhen-Feng WU
China Journal of Chinese Materia Medica 2024;49(24):6565-6573
Identification of critical material attributes(CMAs) is a key issue in the quality control of large-scale TCM products like Jianwei Xiaoshi Tablets. This study focuses on the granules of Jianwei Xiaoshi Tablets, using tablet tensile strength as the primary quality attribute. A method for identifying the CMAs and a design space for the granules were established, along with a predictive model for the granule CMAs based on Fourier transform near-infrared spectroscopy(FT-NIR). First, granules of Jianwei Xiaoshi Tablets with different properties were prepared using a partial factorial design method from the design of experiments(DOE). The powder properties of the granules were measured. An orthogonal partial least squares(OPLS) model was established to correlate the powder properties with tensile strength. Based on the characteristics of the comprehensive variables extracted by OPLS, the independent variables with the greatest explanatory power for tensile strength were identified. FT-NIR technology was then employed to establish a predictive model for the granule CMAs. The final CMAs identified were hygroscopicity, moisture content, D_(50), collapse angle, mass flow rate, and tapped density. The coefficients of determination of the prediction set(R■) and relative percentage deviation(RPD) of the prediction set for flowability, D_(50), and moisture content were 0.891, 0.994, and 0.998; and 2.97, 12.4, and 20.7, respectively. The established OPLS model clearly identified the impact of various factors on tensile strength, demonstrating good fit results. The model exhibited high prediction accuracy and can be used for the rapid and accurate determination of CMAs in granules of Jianwei Xiaoshi Tablets.
Drugs, Chinese Herbal/chemistry*
;
Tablets/chemistry*
;
Tensile Strength
;
Quality Control
;
Spectroscopy, Fourier Transform Infrared
;
Spectroscopy, Near-Infrared
10.Application of combined cone-beam CT and ExacTrac X-ray image-guided system in high-grade glioma radiotherapy
Jun ZHOU ; Han-Xu LI ; Zhi-Bing HUANG ; Jiu-Qing WAN ; Dong-Chun LI ; Liang-Zhi ZHONG
Chinese Medical Equipment Journal 2024;45(8):57-62
Objective To explore the optimal image-guided verification mode by using combined cone-beam CT(CBCT)and ExacTrac X-ray(ETX)image-guided system for the position verification during the first and remaining fractionated radiotherapy of high-grade glioma patients.Methods Twenty high-grade glioma patients undergoing intensity-modulated radiotherapy at some hospital from January 2018 to June 2020 were analyzed retrospectively.CBCT image-guided system was used for the patients treated for the first time to determine the corresponding position of the treatment center on the body surface and to reset and mark the treatment center,then on-line auto registration of the CBCT images with CT positioning images was carried out,and the residual setup errors were verified with ETX image-guided system;position verification of the setup errors was performed with ETX image-guided sysem during the remaining fractionated treatment.The setup errors and their interval distributionswere calculated for the patients in six directions including left-right direction(Lat),head-foot direction(Lng),anterior-posterior direction(Vrt),rotation around left-right(Pitch),rotation around head-foot(Roll)and rotation around anterior-posterior(Yaw).SPSS 22.0 statistical software was used for data analysis.Results There were 75%patients treated for the first time and 78.62%ones undergoing the remaining fractionated radiotherapy only needed one time of setup error corre-ction.Combined CBCT and ETX image-guided resetting during the first radiotherapy met clinical requirements;during the remaining fractionated radiotherapy there were significant differences between the setup errors in the six directions before and after calibration(P<0.05).The interval distribution of setup errors showed the error values in the six directions were all restricted within 0 to 1 mm and within 0° to l °during the first and remaining fractionated radiotherapy.Conclusion Involve-ment of combined CBCT and ETX image-guided system in the first and remaining fractionated radiotherapy of high-grade glioma patients after operation contributes to determining and resetting the treatment center rapidly and accurately,decreasing setup errors and enhancing the accuracy and repeatability of radiotherapy.[Chinese Medical Equipment Journal,2024,45(8):57-62].

Result Analysis
Print
Save
E-mail