1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Pien Tze Huang Attenuates Cell Proliferation and Stemness Promoted by miR-483-5p in Hepatocellular Carcinoma Cells.
Li-Hui WEI ; Xi CHEN ; A-Ling SHEN ; Yi FANG ; Qiu-Rong XIE ; Zhi GUO ; Thomas J SFERRA ; You-Qin CHEN ; Jun PENG
Chinese journal of integrative medicine 2025;31(9):782-791
OBJECTIVE:
To investigate the effect of miR-483-5p on hepatocellular carcinoma (HCC) cells proliferation and stemness, as well as the attenuating effect of Pien Tze Huang (PZH).
METHODS:
Differentially expressed miRNA between HepG2 cells and hepatic cancer stem-like cells (HCSCs) were identified by a miRNA microarray assay. miR-483-5p mimics were transfected into HepG2 cells to explore the effects of miR-483-5p on cell proliferation and stemness. HepG2 cells and HCSCs were treated with PZH (0, 0.25, 0.50 and 0.75 mg/mL) to explore the effects of PZH on the proliferation and stemness, both in non-induced state and the state induced by miR-483-5p mimics.
RESULTS:
miR-483-5p was significantly up-regulated in HCSCs and its overexpression increased cell proliferation and stemness in HepG2 cells (P<0.05). PZH not only significantly inhibited proliferation in HepG2 cells, but also significantly suppressed the cell proliferation and self-renewal of HCSCs (P<0.05). The effects of miR-483-5p mimics on proliferation and stemness of HepG2 cells were partially abolished by PZH.
CONCLUSIONS
miR-483-5p promotes proliferation and enhances stemness of HepG2 cells, which were attenuated by PZH, demonstrating that miR-483-5p is a potential molecular target for the treatment of HCC and provide experimental evidence to support clinical use of PZH for patients with HCC.
Humans
;
MicroRNAs/metabolism*
;
Cell Proliferation/drug effects*
;
Liver Neoplasms/drug therapy*
;
Carcinoma, Hepatocellular/drug therapy*
;
Hep G2 Cells
;
Neoplastic Stem Cells/metabolism*
;
Drugs, Chinese Herbal/therapeutic use*
;
Gene Expression Regulation, Neoplastic/drug effects*
7.Susceptible Windows of Prenatal Ozone Exposure and Preterm Birth: A Hospital-Based Observational Study.
Rong Rong QU ; Dong Qin ZHANG ; Han Ying LI ; Jia Yin ZHI ; Yan Xi CHEN ; Ling CHAO ; Zhen Zhen LIANG ; Chen Guang ZHANG ; Wei Dong WU ; Jie SONG
Biomedical and Environmental Sciences 2025;38(2):255-260
8.Effects of Laparoscopic Sleeve Gastrectomy on Cardiac Structure and Function in Obese Patients With Heart Failure.
Xiao-Yan JIA ; Rui-Jia LIAN ; Bao-Dong MA ; Yang-Xi HU ; Qin-Jun CHU ; Hai-Yun JING ; Zhi-Qiang KANG ; Jian-Ping YE ; Xi-Wen MA
Acta Academiae Medicinae Sinicae 2025;47(2):226-236
Objective To investigate the effects of laparoscopic sleeve gastrectomy(LSG)on the cardiac structure and function in obese patients with heart failure(HF)and compare the efficacy of LSG across obese patients with different HF types.Methods This study included 33 obese patients with HF who underwent LSG.The clinical indicators were compared between before operation and 12 months after operation.Repeated measures analysis of variance was employed to evaluate the changes in echocardiographic parameters before operation and 3,6,and 12 months after operation.Patients were allocated into a HF with preserved ejection fraction group(n=17),a HF with mildly reduced ejection fraction group(n=5)and a HF with reduced ejection fraction(HFrEF)group(n=11)based on left ventricular ejection fraction(LVEF)before operation for subgroup analyses of the effects of LSG on the cardiac structure and function of obese patients with HF.The paired samples t-test was conducted to assess the degree of cardiac structural and functional alterations after LSG.Results The 33 patients included 69.7% males,with an average age of(35.3±9.9)years,and a body mass index(BMI)of(51.2±9.8)kg/m2.The median follow-up was 9.0(5.0,13.3)months.Compared with the preoperative values,the postoperative BMI(P=0.002),body surface area(BSA)(P=0.009),waist circumference(P=0.010),hip circumference(P=0.031),body fat content(P=0.007),and percentage of patients with cardiac function grades Ⅲ-IV(P<0.001)decreased.At the 12-month follow-up left atrial diameter(P=0.006),right atrial long-axis inner diameter(RAD1)(P<0.001),right atrial short-axis inner diameter(RAD2)(P<0.001),right ventricular inner diameter(P=0.002),interventricular septal thickness at end-diastolic(P=0.002),and left ventricular end-diastolic volumes(P=0.004)and left ventricular end-systolic volumes(P=0.003) all significantly reduced compared with preoperative values.Additionally,left ventricular fractional shortening and LVEF improved(both P<0.001).Subgroup analyses revealed that cardiac structural parameters significantly decreased in the HF with preserved ejection fraction,HF with mildly reduced ejection fraction,and HFrEF subgroups compared with preoperative values.Notably,the HFrEF group demonstrated the best performance in terms of left atrial diameter(P=0.003),left ventricular inner diameter at end-diastole(P=0.008),RAD1(P<0.001),RAD2(P=0.004),right ventricular inner diameter(P=0.019),left ventricular end-diastolic volume(P=0.004)and left ventricular end-systolic volume(P=0.001),cardiac output(P=0.006),tricuspid regurgitation velocity(P=0.002),and pulmonary artery systolic pressure(P=0.001) compared to preoperatively.Postoperative left ventricular fractional shortening(P<0.001,P=0.003,P<0.001)and LVEF(P<0.001,P=0.011,P=0.001)became higher in all the three subgroups than the preoperative values.Conclusions LSG decreased the body weight,BMI,and BSA,improved the cardiac function grade,reversed the enlargement of the left atrium and left ventricle,reduced the right atrium and right ventricle,and enhanced the left ventricular systolic function.It was effective across obese patients with different HF types.Particularly,LSG demonstrates the best performance in improving the structures of both atria and ventricles in obese patients with HFrEF.
Humans
;
Male
;
Female
;
Gastrectomy/methods*
;
Heart Failure/complications*
;
Adult
;
Obesity/physiopathology*
;
Laparoscopy
;
Middle Aged
;
Heart/physiopathology*
;
Stroke Volume
9.Isotope dilution HPLC-MS/MS method for simultaneous determination of four antimicrobials in children with small volume of plasma
Zhi-Mei YANG ; Ya-Bin QIN ; Yu HAN ; Xi-Juan JIANG
The Chinese Journal of Clinical Pharmacology 2024;40(10):1507-1511
Objective To establish a high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method for simultaneous determination of meropenem,linezolid,voriconazole and posaconazole in children with small volume of plasma,and to use the method in children therapeutic drug monitoring(TDM).Methods The plasma samples were precipitated protein by methanol.And then,the analytes were gradient eluted on an EVO-C18 column by HPLC-MS/MS with mobile phase consisted of water(0.1%formic acid)-acetonitrile(0.1%formic acid)at the flow rate of 0.5 mL·min 1.Ions were monitored in the multiple reaction monitoring(MRM)mode,using positive ion electrospray ionization(ESI).Results Meropenem had a good liner relationship in 0.5-64.0 μg·mL-1(r=0.999 2),0.2-25.6 μg·mL-1 for linezolid and voriconazole(r=0.999 2,r=0.999 9),and 0.1-12.8 μg·mL-1 for posaconazole(r=0.998 9).Accuracy,precision,matrix effect and stability studies all met the requirements.This method was fully verified,and applied to determine the plasma antimicrobial concentrations of 49 pediatric patients.Conclusion The method is simple,rapid,sensitive and suitable for children's plasma concentration monitoring of four antimicrobials.
10.Role of problem chain and course ideological and political cases teaching method in enhancing clinical medication ability research
Zhi-Hua QIN ; Long-Xi PENG ; Gao-Shuang LAN ; Xiao-Bin ZHANG ; Jiao-Jiao YANG ; Liang ZHU ; Xi-Long QIU ; Yun-Long CHEN
The Chinese Journal of Clinical Pharmacology 2024;40(11):1650-1653
Nowadays,with the continuous deepening and development of vocational education teaching reform,medical higher vocational education always takes moral education as the fundamental task.As an independent type of education,vocational education should always deepen the integration of industry and education and the integration of science and education.Through the teaching research of"problem chain+course ideological and political case",this study innovates the coordinated education team of drug nursing curriculum,the collaborative education method and the collaborative education evaluation,and improves the teaching effect.

Result Analysis
Print
Save
E-mail