1.Effect Analysis of Different Interventions to Improve Neuroinflammation in The Treatment of Alzheimer’s Disease
Jiang-Hui SHAN ; Chao-Yang CHU ; Shi-Yu CHEN ; Zhi-Cheng LIN ; Yu-Yu ZHOU ; Tian-Yuan FANG ; Chu-Xia ZHANG ; Biao XIAO ; Kai XIE ; Qing-Juan WANG ; Zhi-Tao LIU ; Li-Ping LI
Progress in Biochemistry and Biophysics 2025;52(2):310-333
Alzheimer’s disease (AD) is a central neurodegenerative disease characterized by progressive cognitive decline and memory impairment in clinical. Currently, there are no effective treatments for AD. In recent years, a variety of therapeutic approaches from different perspectives have been explored to treat AD. Although the drug therapies targeted at the clearance of amyloid β-protein (Aβ) had made a breakthrough in clinical trials, there were associated with adverse events. Neuroinflammation plays a crucial role in the onset and progression of AD. Continuous neuroinflammatory was considered to be the third major pathological feature of AD, which could promote the formation of extracellular amyloid plaques and intracellular neurofibrillary tangles. At the same time, these toxic substances could accelerate the development of neuroinflammation, form a vicious cycle, and exacerbate disease progression. Reducing neuroinflammation could break the feedback loop pattern between neuroinflammation, Aβ plaque deposition and Tau tangles, which might be an effective therapeutic strategy for treating AD. Traditional Chinese herbs such as Polygonum multiflorum and Curcuma were utilized in the treatment of AD due to their ability to mitigate neuroinflammation. Non-steroidal anti-inflammatory drugs such as ibuprofen and indomethacin had been shown to reduce the level of inflammasomes in the body, and taking these drugs was associated with a low incidence of AD. Biosynthetic nanomaterials loaded with oxytocin were demonstrated to have the capability to anti-inflammatory and penetrate the blood-brain barrier effectively, and they played an anti-inflammatory role via sustained-releasing oxytocin in the brain. Transplantation of mesenchymal stem cells could reduce neuroinflammation and inhibit the activation of microglia. The secretion of mesenchymal stem cells could not only improve neuroinflammation, but also exert a multi-target comprehensive therapeutic effect, making it potentially more suitable for the treatment of AD. Enhancing the level of TREM2 in microglial cells using gene editing technologies, or application of TREM2 antibodies such as Ab-T1, hT2AB could improve microglial cell function and reduce the level of neuroinflammation, which might be a potential treatment for AD. Probiotic therapy, fecal flora transplantation, antibiotic therapy, and dietary intervention could reshape the composition of the gut microbiota and alleviate neuroinflammation through the gut-brain axis. However, the drugs of sodium oligomannose remain controversial. Both exercise intervention and electromagnetic intervention had the potential to attenuate neuroinflammation, thereby delaying AD process. This article focuses on the role of drug therapy, gene therapy, stem cell therapy, gut microbiota therapy, exercise intervention, and brain stimulation in improving neuroinflammation in recent years, aiming to provide a novel insight for the treatment of AD by intervening neuroinflammation in the future.
2.Robotic visualization system-assisted microsurgical reconstruction of the reproductive tract in male rats
Zheng LI ; Jian-Jun DONG ; Ming LIU ; Xun-Zhu WU ; Ren-Feng JIA ; San-Wei GUO ; Kai MENG ; Chen-Cheng YAO ; Er-Lei ZHI ; Gang LIU ; Da-Xian TAN ; Zheng LI ; Peng LI
National Journal of Andrology 2024;30(8):675-680
Objective:To evaluate the safety and efficiency of robotic visualization system(RVS)-assisted microsurgical re-construction of the reproductive tract in male rats and the satisfaction of the surgeons.Methods:We randomly divided 8 adult male SD rats into an experimental and a control group,the former treated by RVS-assisted microsurgical vasoepididymostomy(VE)or vaso-vasostomy(VV),and the latter by VE or VV under the standard operating microscope(SOM).We compared the operation time,me-chanical patency and anastomosis leakage immediately after surgery,and the surgeons'satisfaction between the two groups.Results:No statistically significant difference was observed the operation time between the experimental and the control groups,and no anasto-mosis leakage occurred after VV in either group.The rate of mechanical patency immediately after surgery was 100%in both groups,and that of anastomosis leakage after VE was 16.7%in the experimental group and 14.3%in the control.Compared with the control group,the experimental group achieved dramatically higher scores on visual comfort(3.00±0.76 vs 4.00±0.53,P<0.05),neck/back comfort(2.75±1.16 vs 4.38±1.06,P<0.01)and man-machine interaction(3.88±1.55 va 4.88±0.35,P<0.05).There were no statistically significant differences in the scores on image definition and operating room suitability between the two groups.Conclusion:RVS can be used in microsurgical reconstruction of the reproductive tract in male rats and,with its advantages over SOM in ergonomic design and image definition,has a potential application value in male reproductive system micosurgery.
3.Analysis of influencing factors on clinical pregnancy outcomes in patients with hydrosalpinx undergoing in vitro fertilization-embryo transfer after interventional embolization
Kai ZHANG ; Zhiwei CHENG ; Hongwu QIAO ; Yunxiao ZHI ; Xin ZHAO ; Yichun GUAN ; Lin LU ; Xiangting LIU ; Guangying NIU ; Yaping WANG
Chinese Journal of Radiology 2024;58(9):929-934
Objective:To explore the influencing factors of clinical pregnancy outcomes in patients with hydrosalpinx undergoing in vitro fertilization-embryo transfer(IVF-ET) after interventional embolization and whether residual hydrops has an adverse impact on pregnancy outcomes.Methods:Clinical data from 65 patients who underwent interventional embolization and IVF-ET for hydrosalpinx at the Third Affiliated Hospital of Zhengzhou University from March 2021 to October 2022 were collected retrospectively. The hydrops index was quantified by the ratio of the widest diameter to the pelvic transverse diameter of the intraoperative hydrops, and the patient′s age, body mass index(BMI), follicle-stimulating hormone(FSH), lutenizing hormine(LH), estradiol(E2), automated matetials hangling(AMH), endometrial thickness at the time of transplantation, the number of transplanted embryos, embryo type, and location of the hydrosalpinx were recorded. In addition, the clinical pregnancy outcomes of the first transplantation after embolization were followed. Two independent samples t-test, rank sum test and chi-square test were used to analyze the difference of the above indexes among different clinical pregnancy outcomes by SPSS 25.0. The receiver operating characteristic (ROC) curves and Youden index were used to calculate the cut-off value of the water accumulation index. Results:Among 65 patients, the clinical pregnancy rate was 63.1%(41/65), among the 45 patients who underwent embryo transfer before embolization without success, the clinical pregnancy rate after embolization was 62.2%(28/45). Based on data analysis, it showed that IVF-ET clinical pregnancy outcomes were not associated with age, BMI, FSH, LH, E2, AMH, endometrial thickness at the time of transplantation, the number of transplanted embryos, embryo type, as well as location of hydrosalpinx( P>0.05), but associated with hydrosalpinx index( P<0.001). ROC curve analysis showed that the hydrops index could be used as a predictor of pregnancy outcome, and the area under the curve was 0.825, and the optimal cut-off value of the hydrops index was 12.925% based on the Youden index analysis result. Conclusions:Interventional embolization of hydrosalpinx may improve clinical pregnancy rates. When the hydrosalpinx is large enough, it could adversely affected IVF-ET clinical pregnancy, and further aspiration of hydrosalpinx should be performed prior to transplantation.
4.Status of wearable flexible monitoring devices based on organic field effect transistors in biomedical field
Kai GUO ; Cui-Zhi TANG ; Bo SUN ; Duan-Qiang XIAO ; Yuan-Biao LIU ; En-Xiang JIAO ; Jie GONG ; Hai-Jun ZHANG
Chinese Medical Equipment Journal 2024;45(1):93-100
The working principle and development of flexible semiconductor devices based on organic field effect transistor(OFET)technology were introduced.The current research status of OFET-based wearable flexible monitoring devices were reviewed,including biomechanical monitoring devices,tattoo biomonitoring devices and cellular detection devices and etc.The deficiencies of OFET-based wearable flexible monitoring devices were analyzed,and it's pointed out that miniaturization,personalization and diversification were the directions for the development of the future OFET-based wearable flexible moni-toring devices.[Chinese Medical Equipment Journal,2024,45(1):93-100]
5.Cardiac MR tissue tracking technique for quantitatively evaluating myocardial strain of cardiac amyloidosis patients
Jiangkai HE ; Chen CUI ; Wei MA ; Zhi WANG ; Jia LIU ; Wei LI ; Kai ZHAO ; Rile NAI ; Shasha XU ; Jianxing QIU
Chinese Journal of Interventional Imaging and Therapy 2024;21(1):42-47
Objective To observe the feasibility of cardiac MR tissue tracking(CMR-TT)technique for quantitatively evaluating myocardial strain of patients with myocardial amyloidosis(CA).Methods Cardiac MRI were collected from 20 patients of immunoglobulin amyloid light-chain CA(AL-CA,group A),20 cases of transthyretin CA(ATTR-CA,group B)and 20 healthy subjects(group C),and myocardial strain parameters were obtained using CMR-TT technique.Left ventricular cardiac function parameters were compared among 3 groups,so were strain parameters of each myocardial segment of left ventricle and global myocardium,including 3D longitudinal strain(LS),3D radial strain(RS)and 3D circumferential strain(CS).Results Compared with those in group C,significant differences of left ventricular cardiac function parameters were found in both group A and B(all P<0.01),while no statistical difference was found between group A and B(all P>0.05).Except for apical segment RS(P=0.81),strain parameters in group A and B were both lower than those in group C(all P<0.01),while no significant difference was detected between group A and B(all P>0.05).Conclusion CMR-TT technique could be used to quantitatively evaluate left ventricular myocardial strain of CA patients.
6.A Rapid Non-invasive Method for Skin Tumor Tissue Early Detection Based on Bioimpedance Spectroscopy
Jun-Wen PENG ; Song-Pei HU ; Zhi-Yang HONG ; Li-Li WANG ; Kai LIU ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2024;51(5):1161-1173
ObjectiveIn recent years, with the intensification of environmental issues and the depletion of ozone layer, incidence of skin tumors has also significantly increased, becoming one of the major threats to people’s lives and health. However, due to factors such as high concealment in the early stage of skin tumors, unclear symptoms, and large human skin area, most cases are detected in the middle to late stage. Early detection plays a crucial role in postoperative survival of skin tumors, which can significantly improve the treatment and survival rates of patients. We proposed a rapid non-invasive electrical impedance detection method for early screening of skin tumors based on bioimpedance spectroscopy (BIS) technology. MethodsFirstly, we have established a complete skin stratification model, including stratum corneum, epidermis, dermis, and subcutaneous tissue. And the numerical analysis method was used to investigate the effect of dehydrated and dry skin stratum corneum on contact impedance in BIS measurement. Secondly, differentiation effect of different diameter skin tumor tissues was studied using a skin model after removing the stratum corneum. Then, in order to demonstrate that BIS technology can be used for detecting the microinvasion stage of skin tumors, we conducted a simulation study on the differentiation effect of skin tumors under different infiltration depths. Finally, in order to verify that the designed BIS detection system can distinguish between tumor microinvasion periods, we conducted tumor invasion experiments using hydrogel treated pig skin tissue. ResultsThe simulation results show that a dry and high impedance stratum corneum will bring about huge contact impedance, which will lead to larger measurement errors and affect the accuracy of measurement results. We extracted the core evaluation parameter of relaxed imaginary impedance (Zimag-relax) from the simulation results of the skin tumor model. When the tumor radius (Rtumor) and invasion depth (h)>1.5 mm, the designed BIS detection system can distinguish between tumor tissue and normal tissue. At the same time, in order to evaluate the degree of canceration in skin tissue, the degree of tissue lesion (εworse) is defined by the relaxed imaginary impedance (Zimag-relax) of normal and tumor tissue (εworse is the percentage change in virtual impedance of tumor tissue relative to that of normal tissue), and we fitted a Depth-Zimag-relax curve using relaxation imaginary impedance data at different infiltration depths, which can be applied to quickly determine the infiltration depth of skin tumors after being supplemented with a large amount of clinical data in the future. The experimental results proved that when εworse=0.492 0, BIS could identify microinvasive tumor tissue, and the fitting curve correction coefficient of determination was 0.946 8, with good fitting effect. The simulation using pig skin tissue correlated the results of real human skin simulation with the experimental results of pig skin tissue, proving the reliability of this study, and laying the foundation for further clinical research in the future. ConclusionOur proposed BIS method has the advantages of fast, real-time, and non-invasive detection, as well as high sensitivity to skin tumors, which can be identified during the stage of tumor microinvasion.
7.Research progress on the mechanism of metachronous gastric cancer after endoscopic submucosal dissection and Helicobacter pylori eradication in early gastric cancer
Xin-Yue HU ; Bin WANG ; Tao WANG ; Kai-Jun LIU ; Liang-Zhi WEN ; Dong-Feng CHEN
Medical Journal of Chinese People's Liberation Army 2024;49(1):108-114
Helicobacter pylori(HP)infection is a Class Ⅰ carcinogen in gastric cancer,closely related to the occurrence of gastric cancer.Many studies have shown that HP eradication has a preventive effect on gastric cancer.However,2.7%-6.1%of patients with early gastric cancer who have been eradicated after endoscopic submucosal dissection(ESD)can still develop metachronous gastric cancer(MGC),and the mechanism of its occurrence is still unclear.In this review,the atrophy of gastric mucosa and intestinal metaplasia cannot be completely reversed after HP eradication,the excessive proliferation of gastric mucosa epithelial cells,the accumulation of genetic abnormalities,the homeostasis imbalance of the epigenetic group,changes in immune microenvironment,the abnormality of stem cells in gastric mucosa,chromatin accessibility,and changes in chromosome remodeling were discussed in the mechanism of carcinogenesis caused by the above molecular changes after ESD and HP eradication in early gastric cancer.
8.A study on the application of diffuse axonal multi-axis general evaluation for brain injury assessment in small overlap barrier crash test
Zhi FU ; Yi CHANG ; Tao XIONG ; Wen-Kai GAO ; Kui LI ; Yu LIU
Chinese Journal of Traumatology 2024;27(4):200-210
Purpose::Head injury criterion (HIC) companied by a rotation-based metric was widely believed to be helpful for head injury prediction in road traffic accidents. Recently, the Euro-New Car Assessment Program utilized a newly developed metric called diffuse axonal multi-axis general evaluation (DAMAGE) to explain test device for human occupant restraint (THOR) head injury, which demonstrated excellent ability in capturing concussions and diffuse axonal injuries. However, there is still a lack of comprehensive understanding regarding the effectiveness of using DAMAGE for Hybrid III 50th percentile male dummy (H50th) head injury assessment. The objective of this study is to determine whether the DAMAGE could capture the risk of H50th brain injury during small overlap barrier tests.Methods::To achieve this objective, a total of 24 vehicle crash loading curves were collected as input data for the multi-body simulation. Two commercially available mathematical dynamic models, namely H50th and THOR, were utilized to investigate the differences in head injury response. Subsequently, a decision method known as simple additive weighting was employed to establish a comprehensive brain injury metric by incorporating the weighted HIC and either DAMAGE or brain injury criterion. Furthermore, 35 sets of vehicle crash test data were used to analyze these brain injury metrics.Results::The rotational displacement of the THOR head is significantly greater than that of the H50th head. The maximum linear and rotational head accelerations experienced by H50th and THOR models were (544.6 ± 341.7) m/s 2, (2468.2 ± 1309.4) rad/s 2 and (715.2 ± 332.8) m/s 2, (3778.7 ± 1660.6) rad/s 2, respectively. Under the same loading condition during small overlap barrier (SOB) tests, THOR exhibits a higher risk of head injury compared to the H50th model. It was observed that the overall head injury response during the small overlap left test condition is greater than that during the small overlap right test. Additionally, an equation was formulated to establish the necessary relationship between the DAMAGE values of THOR and H50th. Conclusion::If H50th rather than THOR is employed as an evaluation tool in SOB crash tests, newly designed vehicles are more likely to achieve superior performance scores. According to the current injury curve for DAMAGE and brain injury criterion, it is highly recommended that HIC along with DAMAGE was prioritized for brain injury assessment in SOB tests.
9.Advances of CRISPR/Cas-based Biosensor in Detection of Food-Borne Pathogens
Xiao-Yuan ZHANG ; Zhi-Hao YAO ; Kai-Yu HE ; Hong-Mei WANG ; Xia-Hong XU ; Zu-Fang WU ; Liu WANG
Chinese Journal of Analytical Chemistry 2024;52(4):469-480
Rapid and accurate detection methods for food-borne pathogens are essential to ensure food safety and human health.One promising innovation in this area is the clustered regularly interspaced short palindromic repeats/CRISPR-associated systems(CRISPR/Cas)biosensor,which utilizes Cas protein and CRISPR RNA(crRNA)ribonucleo protein to specifically recognize target genes,and converts target signals into detectable physical and chemical signals.The CRISPR/Cas biosensor shows many advantages,such as high specificity,programmability,and ease of use,making it promising to pathogen detection.This paper introduced the principles and characteristics of CRISPR/Cas systems,along with the strategies for signal recognition,amplification,and output based on different CRISPR/Cas biosensors,and their respective applications in food-borne pathogen detection.Furthermore,the construction principles and challenges of multiple biosensors based on CRISPR/Cas were explored,as well as their potential for simultaneous detection of multiple pathogens.Finally,the challenges and future development trends of CRISPR/Cas-based biosensors in rapid pathogen detection were discussed,aiming to provide valuable reference and inspiration for biosensor designers and food safety practitioners.
10.Prediction of Wind Turbine Lubricating Oil's Acid Value by Ordinary Least Square Method Based on Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy Through Higher-Order Derivative Combined with Angular Metric
Chun-Hui GE ; Yan-Jun LIU ; Meng-Shi CHEN ; Ce YANG ; Pei-Pei LIANG ; Zhi-Xiang YAO ; Kai ZHANG
Chinese Journal of Analytical Chemistry 2024;52(9):1254-1265,中插1-中插4
To address the key challenges in multivariate statistical modeling,a higher-order derivative approach combined with vector space angle multiplicative error correction was proposed for establishing an acid value prediction ordinary least squares(OLS)regression model based on attenuated total reflectance-Fourier transform infrared(ATR-FTIR)spectroscopy.By using acid values measured by potentiometric titration as reference,ATR-FTIR spectroscopy was utilized for direct calibration and prediction of acid values on 96 kinds of lubricating oil samples from a wind turbine.Firstly,the simulated hyperbolic(SH)method was employed to obtain accurate fourth derivative spectrum,resolving overlapping bands and enhancing spectral selectivity.Then,from the calibration set(48 samples),informative spectral regions were identified based on correlation coefficients.Next,the sample with the highest acid value was selected as the reference and1/(1+tan(θ/2))was used as the metric relation of the spectrum to suppress the multiplicity error caused by factors such as the change of effective optical path in ATR-FTIR spectroscopy.After pretreatment of the spectrum by the method of fourth-order derivative combined with angular quantity,the number of variables decreased from 1737 to 8,and the matrix condition number decreased from 1.85×1015 to 56.34,which effectively eliminated the collinearity issue for OLS regression.Direct OLS modeling on spectral preprocessed data achieved a determination coefficient of 0.981 for 47 validation samples,with a relative error range of-8.38%-8.22%,outperforming the commonly used partial least squares(PLS)method(Determination coefficient of 0.865,relative error of-27.82%-22.38%).It was proved that effective data preprocessing significantly improved the prediction accuracy of the model.Furthermore,when the number of calibration set was compressed to 25 and the number of validation set was expanded to 70,the model retained 8 variables with a condition number of 42.60,the determination coefficient of validation set was 0.972,and the relative error ranged from-10.80%to 12.31%.Comparing with the PLS method(Determination coefficient of 0.724,relative error of-34.26%-53.84%),the improvement was more obvious,which showed that the method could still have high prediction accuracy even with fewer modeling samples as well as robustness against multiplicative error interference.

Result Analysis
Print
Save
E-mail