1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Grounded theory, scientific connotation, and clinical application of aromatic immunity in traditional Chinese medicine.
Si-Rui XIANG ; Qin JIAN ; Qi XU ; Jun-Zhi LIN ; Ding-Kun ZHANG ; Ming YANG ; Chuan ZHENG
China Journal of Chinese Materia Medica 2025;50(5):1137-1145
Aromatic immunity in traditional Chinese medicine(TCM) is the medical knowledge accumulated in the process of people's struggling with diseases. It plays an important role in plague prevention, disease treatment, health preservation, and rehabilitation, and has profound TCM basic theoretical support and abundant modern scientific evidence. With the in-depth promotion of the Healthy China initiative and the succession of health needs in the post-COVID-19 era, how to practice the health concept of aromatic immunity in TCM and develop its health service resources with high quality has become an important proposition to be discussed urgently. This paper summarizes the cognitive process, puts forward the basic concept, discusses the scientific connotation and clinical application value, and looks forward to the future development trend of aromatic immunity in TCM, aiming to provide guidance for the development of great health products and promote the application of aromatic immunity in TCM in serving people's health.
Medicine, Chinese Traditional/methods*
;
Humans
;
COVID-19/immunology*
;
China
;
Drugs, Chinese Herbal/therapeutic use*
;
SARS-CoV-2
7.Mechanism of Reactive Oxygen/Nitrogen Species in Liver Ischemia-Reperfusion Injury and Preventive Effect of Chinese Medicine.
Lei GAO ; Yun-Jia LI ; Jia-Min ZHAO ; Yu-Xin LIAO ; Meng-Chen QIN ; Jun-Jie LI ; Hao SHI ; Nai-Kei WONG ; Zhi-Ping LYU ; Jian-Gang SHEN
Chinese journal of integrative medicine 2025;31(5):462-473
Liver ischemia-reperfusion injury (LIRI) is a pathological process involving multiple injury factors and cell types, with different stages. Currently, protective drugs targeting a single condition are limited in efficacy, and interventions on immune cells will also be accompanied by a series of side effects. In the current bottleneck research stage, the multi-target and obvious clinical efficacy of Chinese medicine (CM) is expected to become a breakthrough point in the research and development of new drugs. In this review, we summarize the roles of reactive oxygen species (ROS) and reactive nitrogen species (RNS) in various stages of hepatic ischemia-reperfusion and on various types of cells. Combined with the current research progress in reducing ROS/RNS with CM, new therapies and mechanisms for the treatment of hepatic ischemia-reperfusion are discussed.
Reperfusion Injury/drug therapy*
;
Reactive Oxygen Species/metabolism*
;
Reactive Nitrogen Species/metabolism*
;
Humans
;
Liver/drug effects*
;
Animals
;
Medicine, Chinese Traditional
;
Drugs, Chinese Herbal/pharmacology*
8.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*
9.Effects of Laparoscopic Sleeve Gastrectomy on Cardiac Structure and Function in Obese Patients With Heart Failure.
Xiao-Yan JIA ; Rui-Jia LIAN ; Bao-Dong MA ; Yang-Xi HU ; Qin-Jun CHU ; Hai-Yun JING ; Zhi-Qiang KANG ; Jian-Ping YE ; Xi-Wen MA
Acta Academiae Medicinae Sinicae 2025;47(2):226-236
Objective To investigate the effects of laparoscopic sleeve gastrectomy(LSG)on the cardiac structure and function in obese patients with heart failure(HF)and compare the efficacy of LSG across obese patients with different HF types.Methods This study included 33 obese patients with HF who underwent LSG.The clinical indicators were compared between before operation and 12 months after operation.Repeated measures analysis of variance was employed to evaluate the changes in echocardiographic parameters before operation and 3,6,and 12 months after operation.Patients were allocated into a HF with preserved ejection fraction group(n=17),a HF with mildly reduced ejection fraction group(n=5)and a HF with reduced ejection fraction(HFrEF)group(n=11)based on left ventricular ejection fraction(LVEF)before operation for subgroup analyses of the effects of LSG on the cardiac structure and function of obese patients with HF.The paired samples t-test was conducted to assess the degree of cardiac structural and functional alterations after LSG.Results The 33 patients included 69.7% males,with an average age of(35.3±9.9)years,and a body mass index(BMI)of(51.2±9.8)kg/m2.The median follow-up was 9.0(5.0,13.3)months.Compared with the preoperative values,the postoperative BMI(P=0.002),body surface area(BSA)(P=0.009),waist circumference(P=0.010),hip circumference(P=0.031),body fat content(P=0.007),and percentage of patients with cardiac function grades Ⅲ-IV(P<0.001)decreased.At the 12-month follow-up left atrial diameter(P=0.006),right atrial long-axis inner diameter(RAD1)(P<0.001),right atrial short-axis inner diameter(RAD2)(P<0.001),right ventricular inner diameter(P=0.002),interventricular septal thickness at end-diastolic(P=0.002),and left ventricular end-diastolic volumes(P=0.004)and left ventricular end-systolic volumes(P=0.003) all significantly reduced compared with preoperative values.Additionally,left ventricular fractional shortening and LVEF improved(both P<0.001).Subgroup analyses revealed that cardiac structural parameters significantly decreased in the HF with preserved ejection fraction,HF with mildly reduced ejection fraction,and HFrEF subgroups compared with preoperative values.Notably,the HFrEF group demonstrated the best performance in terms of left atrial diameter(P=0.003),left ventricular inner diameter at end-diastole(P=0.008),RAD1(P<0.001),RAD2(P=0.004),right ventricular inner diameter(P=0.019),left ventricular end-diastolic volume(P=0.004)and left ventricular end-systolic volume(P=0.001),cardiac output(P=0.006),tricuspid regurgitation velocity(P=0.002),and pulmonary artery systolic pressure(P=0.001) compared to preoperatively.Postoperative left ventricular fractional shortening(P<0.001,P=0.003,P<0.001)and LVEF(P<0.001,P=0.011,P=0.001)became higher in all the three subgroups than the preoperative values.Conclusions LSG decreased the body weight,BMI,and BSA,improved the cardiac function grade,reversed the enlargement of the left atrium and left ventricle,reduced the right atrium and right ventricle,and enhanced the left ventricular systolic function.It was effective across obese patients with different HF types.Particularly,LSG demonstrates the best performance in improving the structures of both atria and ventricles in obese patients with HFrEF.
Humans
;
Male
;
Female
;
Gastrectomy/methods*
;
Heart Failure/complications*
;
Adult
;
Obesity/physiopathology*
;
Laparoscopy
;
Middle Aged
;
Heart/physiopathology*
;
Stroke Volume
10.Quantification of Atmospheric Total Reactive Nitrogen Oxides by Thermal Decomposition-Broadband Cavity Enhanced Absorption Spectroscopy
Dou SHAO ; Min QIN ; Wu FANG ; Bao-Bin HAN ; Ke TANG ; Jian-Ye XIE ; Xia-Dan ZHAO ; Zhi-Tang LIAO ; En-Bo REN
Chinese Journal of Analytical Chemistry 2025;53(3):387-396
Nitrogen oxides(NOx=NO+NO2)are important precursors of ozone(O3),and NOx and its oxides together constitute reactive nitrogen oxides(NOy)in the atmosphere.A comprehensive understanding of the total NOy level in the atmosphere is of great significance for a deeper understanding of the atmospheric nitrogen cycle and oxidation,as well as for formulating strategies for air pollution prevention and control.In this work,a thermal decomposition-broadband cavity enhanced absorption spectroscopy(TD-BBCEAS)technique for online measurement of total NOy in the atmosphere was developed.With this method,the NOy was efficiently converted into NO2,and the total NOy concentration in the atmosphere was indirectly obtained by measuring NO2.Focusing on the key factors affecting the measurement of total NOy,the influence of NO titration efficiency and other NOy component TD efficiency on measurement accuracy was emphasized.By changing the oxygen(O2)flow rate through the mercury lamp to alter the O3 concentration for titrating NO,the conversion efficiency of NO was evaluated.At O2 flow rate of 6 mL/min,the conversion efficiency of NO was greater than 99%.TD efficiency testing and analysis on NO2,peroxyacetyl nitrate(PAN),nitric acid(HNO3),and nitrous acid(HONO),which account for a large proportion of atmospheric NOy components,was carried out using 680℃as the optimal TD temperature for efficient conversion of NOy.With NO and HONO sample gases as typical verification gases,the conversion efficiency of NOy and the accuracy of NOy measurement by TD-BBCEAS system were verified by switching the on and off modes of mercury lamp and TD device.At integration time of 60 s,the detection limit of the system for NOy was 2.83×1010 molecules/cm3(60 s,2σ).A comparative measurement of actual atmospheric NOy was conducted between the TD-BBCEAS system and the NOy analyzer.The observation results showed a correlation coefficient(R2)of 0.98 and a slope of 0.93,further verifying the feasibility and accuracy of applying the TD-BBCEAS system to measurement of total NOy.

Result Analysis
Print
Save
E-mail