1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Four new sesquiterpenoids from the roots of Atractylodes macrocephala
Gang-gang ZHOU ; Jia-jia LIU ; Ji-qiong WANG ; Hui LIU ; Zhi-Hua LIAO ; Guo-wei WANG ; Min CHEN ; Fan-cheng MENG
Acta Pharmaceutica Sinica 2025;60(1):179-184
The chemical constituents in dried roots of
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.The Frequency Difference of Red Blood Cell Group Gene Haplotypes among Han, Indian and Uyghur Populations in Shenzhen Region.
Tong LIU ; Jin QIU ; Fan WU ; Yan-Lia LIANG ; Li-Yan SUN ; Zhi-Hui DENG ; Shuang LIANG
Journal of Experimental Hematology 2025;33(3):863-868
OBJECTIVE:
To study the genetic polymorphism of red blood cell blood group among in Shenzhen Han, Indian and Xinjiang Uyghur populations, to provide scientific basis for the demand prediction and collection strategy of rare blood group, and to explore the genetic differences of blood group between Han and Caucasians.
METHODS:
The haplotypes of antigen coding genes of 10 target blood group systems from 87 Han Chinese and 50 Indian blood donors in Shenzhen, and 49 healthy Uyghur people in Xinjiang were obtained by three-generation sequencing technology, and the polymorphism and frequency characteristics were analyzed.
RESULTS:
Only a single genotype was detected the Langereis and Vel blood group systems in samples from three different populations. Only one genotype of Dombrock blood group was detected in Shenzhen Han, and Junior blood group in Xinjiang Uygur populations. In the MNS, Duffy, Kidd, Dombrock and Junior blood group systems, the haplotype frequency of Indian and Uyghur people was significantly different from that of Han people. Compared with the Han ethnic group, the rare blood group s-, Fy(a-), Jk(a-b-), and Do(a+b-) have a higher frequency among the Uyghur and Indian populations.
CONCLUSION
Haplotype frequencies of antigen genes for MNS, Duffy, Kidd, Dombrock and Junior blood group system in Shenzhen Han, Indian and Uyghur populations displayed a polymorphic difference with unique distribution characteristics different from the ethnic groups in other regions.
Humans
;
Blood Group Antigens/genetics*
;
China/ethnology*
;
Erythrocytes
;
Ethnicity/genetics*
;
Gene Frequency
;
Genotype
;
Haplotypes
;
India/ethnology*
;
Polymorphism, Genetic
;
White People/genetics*
;
Central Asian People/genetics*
;
East Asian People/genetics*
8.Efficacy and Safety of Diagnostic-Driven Therapy for Invasive Fungal Disease in Patients with Myeloid Hematologic Malignancies.
Hui XIAO ; Fan WU ; Ying PAN ; Fu-Run AN ; Zhi-Min ZHAI
Journal of Experimental Hematology 2025;33(5):1524-1528
OBJECTIVE:
To investigate the efficacy and safety of diagnostic-driven therapy for invasive fungal disease(IFD) in patients with myeloid hematologic malignancies.
METHODS:
A retrospective analysis was conducted on the clinical data of 91 patients with myeloid hematologic malignancies who received diagnostic-driven therapy for IFD at the Second Hospital of Anhui Medical University from January 1, 2020 to December 31, 2023. The patients were divided into two groups based on medication: 44 patients in the caspofungin group and 47 patients in the voriconazole group. The clinical efficacy and adverse reactions of the two groups were compared and analyzed.
RESULTS:
The overall response rates in the caspofungin and voriconazole groups were 67.4% and 60.0%, respectively. Among patients who transitioned to diagnostic-driven therapy following prophylactic or empirical treatment with triazole antifungal agents, the response rate of the caspofungin group was significantly higher than that of the voriconazole group (76.9% vs 35.3%, P <0.05). A total of 9 patients in both groups experienced adverse reactions, and no grade III or higher adverse reactions occurred. The incidence of grade I-II adverse reactions in the caspofungin group was lower than in the voriconazole group (2.3% vs 17.0%, P <0.05).
CONCLUSION
In patients with myeloid hematologic malignancies, caspofungin and voriconazole demonstrate comparable clinical efficacy in diagnostic-driven therapy for IFD, but caspofungin is associated with a lower incidence of adverse reactions. Caspofungin exhibits significant effectiveness when initiating diagnostic-driven therapy after prophylactic or empirical treatment with broad-spectrum triazole antifungal agents.
Humans
;
Retrospective Studies
;
Hematologic Neoplasms/complications*
;
Antifungal Agents/therapeutic use*
;
Voriconazole/therapeutic use*
;
Caspofungin/therapeutic use*
;
Invasive Fungal Infections/diagnosis*
;
Male
;
Female
;
Mycoses/drug therapy*
;
Middle Aged
;
Treatment Outcome
;
Aged
;
Adult
9.Glutamine signaling specifically activates c-Myc and Mcl-1 to facilitate cancer cell proliferation and survival.
Meng WANG ; Fu-Shen GUO ; Dai-Sen HOU ; Hui-Lu ZHANG ; Xiang-Tian CHEN ; Yan-Xin SHEN ; Zi-Fan GUO ; Zhi-Fang ZHENG ; Yu-Peng HU ; Pei-Zhun DU ; Chen-Ji WANG ; Yan LIN ; Yi-Yuan YUAN ; Shi-Min ZHAO ; Wei XU
Protein & Cell 2025;16(11):968-984
Glutamine provides carbon and nitrogen to support the proliferation of cancer cells. However, the precise reason why cancer cells are particularly dependent on glutamine remains unclear. In this study, we report that glutamine modulates the tumor suppressor F-box and WD repeat domain-containing 7 (FBW7) to promote cancer cell proliferation and survival. Specifically, lysine 604 (K604) in the sixth of the 7 substrate-recruiting WD repeats of FBW7 undergoes glutaminylation (Gln-K604) by glutaminyl tRNA synthetase. Gln-K604 inhibits SCFFBW7-mediated degradation of c-Myc and Mcl-1, enhances glutamine utilization, and stimulates nucleotide and DNA biosynthesis through the activation of c-Myc. Additionally, Gln-K604 promotes resistance to apoptosis by activating Mcl-1. In contrast, SIRT1 deglutaminylates Gln-K604, thereby reversing its effects. Cancer cells lacking Gln-K604 exhibit overexpression of c-Myc and Mcl-1 and display resistance to chemotherapy-induced apoptosis. Silencing both c-MYC and MCL-1 in these cells sensitizes them to chemotherapy. These findings indicate that the glutamine-mediated signal via Gln-K604 is a key driver of cancer progression and suggest potential strategies for targeted cancer therapies based on varying Gln-K604 status.
Glutamine/metabolism*
;
Myeloid Cell Leukemia Sequence 1 Protein/genetics*
;
Humans
;
Proto-Oncogene Proteins c-myc/genetics*
;
Cell Proliferation
;
Signal Transduction
;
Neoplasms/pathology*
;
F-Box-WD Repeat-Containing Protein 7/genetics*
;
Cell Survival
;
Cell Line, Tumor
;
Apoptosis
10.Effect and possible mechanism of Wuzi Yanzong Pill on motor function of neurons in Parkinson's disease mice
Tao PAN ; Qi XIAO ; Hui-Jie FAN ; Lei XU ; Lu JIA ; Shao-Chen QIN ; Li-Ran WANG ; Cun-Gen MA ; Bo ZHANG ; Zhi CHAI
Medical Journal of Chinese People's Liberation Army 2024;49(5):550-556
Objective To observe the effects of Wuzi Yanzong Pill(WYP)on motor function in a mouse model of Parkinson's disease(PD)and to explore its potential mechanisms.Methods Twenty-four male C57BL/6 mice were randomly divided into control group,model group and WYP group,with 8 mice in each group.Mice in model and WYP group were intraperitoneally injected with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine for 7 consecutive days to establish a PD model.From the 1st day of model preparation,mice in WYP group were gavaged with WYP solution[16 g/(kg·d)]twice daily for 14 consecutive days.At the same time,mice in control group and model group were gavaged with 0.9%NaCl solution[50 ml/(kg·d)]twice a day.Gait experiment was utilized to assess the behavioral performance of mice in each group.Immunofluorescence staining was conducted to detect the number of tyrosine hydroxylase(TH)-positive cells in the substantia nigra region,the fluorescence intensity of nuclear factor E2-related factor 2(Nrf2),and the number of NeuN neurons co-labeled with Nrf2 in each group.Western blotting was employed to determine the expression levels of TH,Kelch-like ECH-associated protein 1(Keap-1),Nrf2,and heme oxygenase-1(HO-1)in the brain tissue of mice in each group.Results The gait experiment results showed that,compared with control group,standing time of the left front paw,right front paw,left hind paw,and right hind paw of the mice in model group was significantly shortened(P<0.01),while swinging time of the left front paw,right front paw,left hind paw,and right hind paw was significantly prolonged(P<0.05).Compared with model group,standing time of the left front paw and right hind paw of the mice in WYP group was significantly prolonged(P<0.05),while swing time of the left front paw and right front paw was significantly shortened(P<0.05).Immunofluorescence staining and Western blotting results showed that,compared with control group,in model group the number of TH-positive cells,average fluorescence intensity of Nrf2,and HO-1 levels decreased(P<0.01),while the Keap-1 protein level increased(P<0.01),and the number of Nrf2 expression on NeuN neurons decreased(P<0.001).Compared with model group,the number of TH-positive cells,average fluorescence intensity of Nrf2,HO-1 level,and the number of Nrf2 expression on NeuN neurons in the brain tissue of mice in WYP group increased(P<0.05),while Keap-1 protein level decreased(P<0.05).Conclusions WYP could alleviate the motor dysfunction and protect dopaminergic neurons in PD mice.The underlying mechanism may be related to the regulation of Keap-1/Nrf2/HO-1 pathway to inhibit oxidative stress response.

Result Analysis
Print
Save
E-mail