1.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
2.The value of total volume response and total mass response in the therapeutic evaluation of lung metastasis of hepatocarcinoma
Jun-cheng WAN ; Cai-hong YU ; Chang-yu LI ; Yong-jie ZHOU ; Wei ZHANG ; Jian-hua WANG ; Zhi-ping YAN ; Guo-wei YANG ; Zhuo-yang FAN ; Xu-dong QU
Fudan University Journal of Medical Sciences 2025;52(2):201-208,231
Objective To analyze the correlation between lesion volume,lesion mass,and maximum lesion diameter in the assessment of advanced hepatocarcinoma with lung metastasis,and to evaluate the application value of total volume response and total mass response of lung metastatic lesions in efficacy assessment.Methods A retrospective analysis was conducted on the CT imaging data of 20 patients clinically confirmed with hepatocarcinoma and lung metastases,followed by subsequent follow-up to monitor their survival outcomes.Volume measurement software was used to measure the volume of lesions before and after treatment.We recored lesion diameter,volume measurements and CT values,calculated the mass of the lesions.The correlation between lesion volume,mass and diameter was analyzed,as well as the correlation between the change rates of volume,mass and lesion diameter.Additionally,the total volume and total mass of all lesions were calculated.The correlation between the change rates of total volume/total mass and the change rate of pulmonary lesion diameter under the RECIST 1.1 criteria,as well as the correlation with changes in patients'tumor markers,were analyzed.Furthermore,the overall volume response and overall mass response of lesions were evaluated based on changes in total volume and total mass,and their consistencies with the RECIST 1.1 criteria for efficacy evaluation were analyzed.Finally,univariate Cox regression analysis was performed to explore the association between these variables and patient survival outcomes.Results There was strong correlation between lesion volume,mass and tumor diameter(r=0.771,0.775),between the rate of change in mass and the rate of change in lesion diameter(r=0.846),and between the rates of change in total volume/total mass and the rate of change in pulmonary lesion diameter under the RECIST 1.1 criteria(r=0.800,0.896).The correlation between the rates of change in total volume/total mass and patients'tumor markers was not statistically significant.There was moderate correlation between the rate of change in volume and the rate of change in lesion diameter(r=0.692).The evaluation results of total volume response and total mass response for pulmonary lesions in advanced hepatocarcinoma with lung metastasis were generally consistent with the RECIST 1.1 criteria(Kappa=0.486,0.426).Univariate Cox regression analysis revealed that total lesion volume(P=0.047)and total lesion mass(P=0.049)were independent prognostic factors for survival outcomes.Conclusion Lesion volume,mass,and diameter,as well as their respective change rates,were found to be interrelated.Furthermore,total lesion volume and total lesion mass were identified as independent prognostic factors for survival outcomes.The total volume response and total mass response are promising evaluation methods in evaluating the efficacy of lung metastasis of hepatocarcinoma,which are different from the RECIST 1.1 evaluation criteria.
3.Establishment of a rapid fluorescence immunochromatographic assay for avian influenza virus subtype H5N6
Hui LI ; Li LIU ; Yi-sheng ZHOU ; Zhi-hong ZHANG ; Qian-qian SI ; Ru-xia WANG ; Zhi-qiang DENG ; Yi-bing FAN ; Liang JIN ; Jie SUN ; Chun-hua YANG
Chinese Journal of Zoonoses 2025;41(3):243-248,283
In view of the characteristics of H5N6 subtype avian influenza virus(AIV)that it has both high pathogenicity and the risk of cross-species transmission,posing a serious threat to the poultry farming industry and public health security,in order to effectively prevent and control the spread of H5N6 avian influenza,a rapid,sensitive and specific detection technolo-gy was established in this study.The specific monoclonal antibodies against the neuraminidase N6 protein of avian influenza A virus subtype H5N6 were obtained through hybridoma and monoclonal antibody technology.These antibodies were coupled and labeled with carboxyl-functionalized fluorescent quantum dots,along with previously prepared specific antibodies against the hemagglutinin H5 protein.A rapid fluorescence immunochromatographic detection method for the H5N6 subtype of avian influ-enza virus was established according to the principle of double-antibody sandwich immunochromatography.This method a-chieved a detection sensitivity of 1 ng/mL for recombinant hemagglutinin H5 subtype protein and 0.1 ng/mL for recombinant neuraminidase N6 subtype protein.Moreover,the method exhibited no cross-reactivity with other influenza subtypes or patho-gens,such as Newcastle disease(ND),infectious bronchitis(IB),and infectious laryngotracheitis(ILT),thus demonstrating good specificity.The method effectively identified the highly pathogenic avian influenza virus H5 subtype and directly distin-guished the H5N6 subtype with good accuracy.The fluorescent quantum dot immunochromatographic typing detection method established herein met the sensitivity,specificity,and accuracy requirements for H5N6 subtype detection,and can be further used for rapid detection of the H5 and H5N6 subtypes of avian influenza virus.
4.Dahuang Zhechong pill regulates stress fiber remodeling mediated by mechanistic signaling pathway to alleviate liver cirrhosis
Yi-heng ZHANG ; Su-zhou HUANG ; Xing-xing LU ; Hui-hua FANG ; Hong-lin CHEN ; Fan-sheng MENG ; Gao-hong LYU ; Zhi-peng CHEN ; Li WU
Chinese Pharmacological Bulletin 2025;41(8):1562-1568
Aim To explore the effect of the classical famous prescription Dahuang Zhechong pill(DHZCP)on relieving liver cirrhosis by regulating the stress fiber remodeling mediated by mechanistic signaling pathway and to explore the underlying mechanism.Methods Mice were randomly divided into the control group,model group,DHZCP low-dose group,DHZCP high-dose group,and Colchicine-positive control group.The liver cirrhosis mouse model was constructed by intrap-eritoneal injection of olive oil-solubilized CCl4.HE staining and serologic markers were used to reflect liver injury.Masson staining was used to evaluate collagen deposition in liver tissue.ELISA was applied to detect vasoactive molecules and cancer indicators.Atomic force microscopy was employed to detect liver tissue stiffness.Color Doppler diagnostic instrument was used to assess portal blood flow velocity.Western blot was utilized to detect ROCK2 expression and phosphoryla-tion of YAP,Cofilin,and MLC.Results The liver tis-sues in the model group had obvious inflammatory cell infiltration and collagen deposition,accompanied by significant elevation of serum transaminases and fibrosis indexes.Similarly,vasoactive molecules and cancer in-dicators were elevated,and the mechanoregulatory pro-tein ROCK2 expression and phosphorylation of Cofilin and MLC were elevated,with YAP being strongly de-phosphorylated.Both low and high doses of DHZCP re-versed the pathological changes,serological indices,and inhibited the activation of the stress fiber(SF)re-modeling mechanistic signaling pathway.Conclusion DHZCP effectively ameliorates liver tissue lesions in mice with liver cirrhosis,and its mechanism may be re-lated to the inhibition of SF remodeling mechanistic signaling pathway.
5.Construction of medical consumables selection indicator system based on analytic hierarchy process and fuzzy cluster method
Li-ping FAN ; Miao XIAO ; Guo-zhong LU ; Wei WANG ; Yu-yuan DENG ; Zhi-hong CHEN
Chinese Medical Equipment Journal 2025;46(11):78-83
Objective To construct a medical consumables selection indicator system based on analytic hierarchy process(AHP)and fuzzy cluster method.Methods Firstly,a medical consumables selection indicator system was established preliminarily with the literature research results and actual situation of hospital consumables management;secondly,13 experts in related fields were selected to execute two rounds of online questionnaires,the expert weights were determined with AHP,the importance of each selection indicator was scored by the expert evaluation method and fuzzy cluster method,and consistency analysis was carried out on the two rounds of expert evaluation results;finally,the final medical consumables selection indicator system was built with the 100-point scale.Results The constructed medical consumables selection indicator system was composed of 5 primary indicators,12 secondary indicators and 38 tertiary indicators.The primary indicators included consumables quality,clinical demand,cost-effectiveness,supply capacity and after-sales service,with the percentage-based scores being 27,25,14,26 and 8,respectively.Conclusion The medical consumables selection indicator system based on AHP and fuzzy cluster method with high reliability provides effective and reliable references for medical institutions to select medical consumables.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Expert consensus on management of instrument separation in root canal therapy.
Yi FAN ; Yuan GAO ; Xiangzhu WANG ; Bing FAN ; Zhi CHEN ; Qing YU ; Ming XUE ; Xiaoyan WANG ; Zhengwei HUANG ; Deqin YANG ; Zhengmei LIN ; Yihuai PAN ; Jin ZHAO ; Jinhua YU ; Zhuo CHEN ; Sijing XIE ; He YUAN ; Kehua QUE ; Shuang PAN ; Xiaojing HUANG ; Jun LUO ; Xiuping MENG ; Jin ZHANG ; Yi DU ; Lei ZHANG ; Hong LI ; Wenxia CHEN ; Jiayuan WU ; Xin XU ; Jing ZOU ; Jiyao LI ; Dingming HUANG ; Lei CHENG ; Tiemei WANG ; Benxiang HOU ; Xuedong ZHOU
International Journal of Oral Science 2025;17(1):46-46
Instrument separation is a critical complication during root canal therapy, impacting treatment success and long-term tooth preservation. The etiology of instrument separation is multifactorial, involving the intricate anatomy of the root canal system, instrument-related factors, and instrumentation techniques. Instrument separation can hinder thorough cleaning, shaping, and obturation of the root canal, posing challenges to successful treatment outcomes. Although retrieval of separated instrument is often feasible, it carries risks including perforation, excessive removal of tooth structure and root fractures. Effective management of separated instruments requires a comprehensive understanding of the contributing factors, meticulous preoperative assessment, and precise evaluation of the retrieval difficulty. The application of appropriate retrieval techniques is essential to minimize complications and optimize clinical outcomes. The current manuscript provides a framework for understanding the causes, risk factors, and clinical management principles of instrument separation. By integrating effective strategies, endodontists can enhance decision-making, improve endodontic treatment success and ensure the preservation of natural dentition.
Humans
;
Root Canal Therapy/adverse effects*
;
Consensus
;
Root Canal Preparation/adverse effects*
10.Association between Per and Polyfluoroalkyl Substance and Abdominal Fat Distribution: A Trait Spectrum Exposure Pattern and Structure-Based Investigation.
Zhi LI ; Shi Lin SHAN ; Chen Yang SONG ; Cheng Zhe TAO ; Hong QIAN ; Qin YUAN ; Yan ZHANG ; Qiao Qiao XU ; Yu Feng QIN ; Yun FAN ; Chun Cheng LU
Biomedical and Environmental Sciences 2025;38(1):3-14
OBJECTIVE:
To investigate the associations between eight serum per- and polyfluoroalkyl substances (PFASs) and regional fat depots, we analyzed the data from the National Health and Nutrition Examination Survey (NHANES) 2011-2018 cycles.
METHODS:
Multiple linear regression models were developed to explore the associations between serum PFAS concentrations and six fat compositions along with a fat distribution score created by summing the concentrations of the six fat compositions. The associations between structurally grouped PFASs and fat distribution were assessed, and a prediction model was developed to estimate the ability of PFAS exposure to predict obesity risk.
RESULTS:
Among females aged 39-59 years, trunk fat mass was positively associated with perfluorooctane sulfonate (PFOS). Higher concentrations of PFOS, perfluorohexane sulfonate (PFHxS), perfluorodecanoate (PFDeA), perfluorononanoate (PFNA), and n-perfluorooctanoate (n-PFOA) were linked to greater visceral adipose tissue in this group. In men, exposure to total perfluoroalkane sulfonates (PFSAs) and long-chain PFSAs was associated with reductions in abdominal fat, while higher abdominal fat in women aged 39-59 years was associated with short-chain PFSAs. The prediction model demonstrated high accuracy, with an area under the curve (AUC) of 0.9925 for predicting obesity risk.
CONCLUSION
PFAS exposure is associated with regional fat distribution, with varying effects based on age, sex, and PFAS structure. The findings highlight the potential role of PFAS exposure in influencing fat depots and obesity risk, with significant implications for public health. The prediction model provides a highly accurate tool for assessing obesity risk related to PFAS exposure.
Humans
;
Fluorocarbons/blood*
;
Female
;
Adult
;
Middle Aged
;
Male
;
Environmental Pollutants/blood*
;
Abdominal Fat
;
Nutrition Surveys
;
Alkanesulfonic Acids/blood*
;
Obesity
;
Environmental Exposure

Result Analysis
Print
Save
E-mail