1.Effect of different decompression methods on unilateral biportal endoscopy in the treatment of elderly patients with severe lumbar spinal stenosis
Zhi-long ZHANG ; Hai-ying WANG ; Feng-hua MA ; Yan-jie HOU
Journal of Regional Anatomy and Operative Surgery 2025;34(9):780-784
Objective To investigate the effect of different decompression methods on the efficacy of the unilateral biportal endoscopy(UBE)in the treatment of severe lumbar spinal stenosis(LSS).Methods A total of 203 elderly patients with LSS who underwent UBE treatment in our hospital from September 2021 to June 2024 were selected and divided into the unilateral group(102 cases)and the bilateral group(101 cases)according to different decompression methods.The unilateral group underwent unilateral decompression during operation,while the bilateral group underwent bilateral decompression(with bilateral decompression through the same incision and unilateral approach)during operation.The perioperative conditions,anatomical image parameters,visual analogue scale(VAS)scores,Oswestry disability index(ODI),and complications were compared between the two groups.The rehabilitation progress and complications of patients with different Charlson comorbidity index(CCI)values were compared.Results The operation time of patients in the bilateral group was longer than that in the unilateral group(P<0.05).The dural sac area and lumbar spinal canal area of patients in the bilateral group were larger than those in the unilateral group immediately after operation and 3 months after operation(P<0.05).The VAS scores and ODI 7 days and 3 months after operation of patients in the bilateral group were lower than those in the unilateral group(P<0.05).There was no statistically significant difference in the total incidence of complications between the two groups of patients(P>0.05).The first time of getting out of bed after operation and hospital stay in patients with CCI value>2 scores were longer than those in patients with CCI value≤2 scores(P<0.05).Conclusion Compared with unilateral decompression,bilateral decompression for elderly patients with severe LSS takes a longer surgical time,but it can better restore lumbar shape,alleviate pain,improve lumbar function,and has higher safety,and the milder the patient's condition,the faster the postoperative recovery.
2.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
3.Comparison of differences in dosimetry and treatment efficiency of modified radiotherapy plans after left-sided breast-conserving surgery
Jian-hai LIN ; Jing FENG ; Zhong-hua CHEN ; Zhi-chao FU ; Jie CHEN ; Nan-bao ZHONG
Chinese Medical Equipment Journal 2025;46(4):45-51
Objective To compare the differences in dosimetry and treatment efficiency of three radiotherapy plans after left-sided breast-conserving surgery,including modified intensity-modulated radiation therapy(IMRT),cross-field volume-modulated arc therapy(VMAT)or improved VMAT,so as to provide references for clinical practice.Methods Three radiotherapy plans of modified IMRT,cross-field VMAT and improved VMAT were designed for 12 patients after left-sided-breast-conserving surgery.The modified IMRT with five irradiation fields and the improved VMAT with two arcs were modified by not setting cross-fields while determining the start and end angles with the rays passing through the least lung area.The cross-field VMAT had its start and end angles set based on the cross-fields.The doses to the target areas,peripheral organs at risk,heart and its substructures were evaluated,and dose verification was carried out.The three plans were compared in terms of treatment efficiency and gamma pass rate.SPSS 22.0 was used for statistical analysis.Results All the three plans behaved well in dose distribution.In terms of planning gross tumor volume dosimetry dosimetry,the improved VMAT and modified IMRT gained advantages than others in CI and D50,respectively,with the differences being significant(all P<0.05).In terms of planning target volume dosimetry,the modified IMRT had the V107 and D50 lower than those of the others,with the differences being significant(P<0.05).In terms of the protection of peripheral organs at risk,V5 of the left lung,Dmean of the right lung and Dmean of the healthy breast were lower in the modified IMRT plan than in the other 2 plans,with statistically significant differences(P<0.05);V20,V30,V35 and V40 of the left lung were lower in the modified VMAT plan than in the other 2 plans,with statistically significant differences(P<0.05).In terms of protection of heart and its substructures,the left ventricle V20,V30 and Dmean of the improved VMAT plan behaved better than those of other 2 plans,and the difference was statistically significant(all P<0.05).In terms of treatment efficiency,the cross-field VMAT plan had the lowest MU while highest treatment efficiency;the improved VMAT plan had the MU higher while the treatment efficiency lower than the cross-field VMAT plan;the modified IMRT plan had the highest MU while the lowest gamma pass rate,and the differences in the MUs and gamma pass rates among the three plans were statistically significant(P<0.05).Conclusion Under the same standard conditions,the cross-field VMAT and improved VMAT plans show technical advantages.Though the improved VMAT plan has the treatment efficiency lower than the cross-field VMAT,it decreases the possibility of radiocardiac injury in terms of dosimetry and thus can be used for radiotherapy after left-sided breast-conserving surgery.[Chinese Medical Equipment Journal,2025,46(4):45-51]
4.Predictive efficacy of multimodal MRI-based machine learning models for glioblastoma multiforme MGMT promoter methylation states
Hong-lin LI ; Shi-ting HU ; Zi-heng ZHOU ; Bing LI ; Zhi-ping QI ; Ruo-qi LI ; Kai LIU ; Chun-feng HU ; Hai-tao GE
Chinese Medical Equipment Journal 2025;46(6):7-13
Objective To explore the predictive efficacy of several multimodal MRI-based machine learning models for the promoter methylation states of O6-methylguanine-DNA methyltransferase(MGMT)of glioblastoma muliforme(GBM)patients in terms of the GBM heterogeneity and the complexity of the tumor microenvironment.Methods Firstly,the multimodal MRI images of 317 GBM patients from The University of Pennsylvania Glioblastoma(UPENN-GBM)dataset were pre-processed,with four sequences involved in including T1-weighted imaging(T1WI)sequence,T1-weighted contrast-enhanced imaging(T1CE)sequence,T2-weighted imaging(T2WI)sequence and fluid-attenuated inversion recovery(FLAIR)sequence,and the radiomics features were extracted for two regions of interest(ROIs)such as the tumor core region and the tumor edema region.Secondly,the data of the 317 GBM patients were randomly divided into a training set(254 cases)and a test set(63 cases),which underwent normalization with Z-scores and feature selection and dimensionality reduction with Lasso regression.Finally,three models were established respectively with particle swarm optimization-support vector machine(PSO-SVM),C-support vector classification(C-SVC)and adaptive boosting(adaptive boosting(Adaboost)algorithms,and the predictive efficacy of the three models for glioblastoma multiforme MGMT promoter methylation states were evaluated in terms of accuracy and AUC.Results The Adaboost model based on T2WI sequence and radiomics features of the tumor core region had the highest predictive efficacy with accuracy and AUC values of 67%and 0.74,respectively,higher than those of other combinations of sequences,models and regions of interest.Conclusion The multimodal MRI-based machine learning models can be used for the prediction of glioblastoma multiforme MGMT promoter methylation states,which provides powerful support for personalized treatment and prognostic assessment of GBM.[Chinese Medical Equipment Journal,2025,46(6):7-13]
5.Predictive efficacy of multimodal MRI-based machine learning models for glioblastoma multiforme MGMT promoter methylation states
Hong-lin LI ; Shi-ting HU ; Zi-heng ZHOU ; Bing LI ; Zhi-ping QI ; Ruo-qi LI ; Kai LIU ; Chun-feng HU ; Hai-tao GE
Chinese Medical Equipment Journal 2025;46(6):7-13
Objective To explore the predictive efficacy of several multimodal MRI-based machine learning models for the promoter methylation states of O6-methylguanine-DNA methyltransferase(MGMT)of glioblastoma muliforme(GBM)patients in terms of the GBM heterogeneity and the complexity of the tumor microenvironment.Methods Firstly,the multimodal MRI images of 317 GBM patients from The University of Pennsylvania Glioblastoma(UPENN-GBM)dataset were pre-processed,with four sequences involved in including T1-weighted imaging(T1WI)sequence,T1-weighted contrast-enhanced imaging(T1CE)sequence,T2-weighted imaging(T2WI)sequence and fluid-attenuated inversion recovery(FLAIR)sequence,and the radiomics features were extracted for two regions of interest(ROIs)such as the tumor core region and the tumor edema region.Secondly,the data of the 317 GBM patients were randomly divided into a training set(254 cases)and a test set(63 cases),which underwent normalization with Z-scores and feature selection and dimensionality reduction with Lasso regression.Finally,three models were established respectively with particle swarm optimization-support vector machine(PSO-SVM),C-support vector classification(C-SVC)and adaptive boosting(adaptive boosting(Adaboost)algorithms,and the predictive efficacy of the three models for glioblastoma multiforme MGMT promoter methylation states were evaluated in terms of accuracy and AUC.Results The Adaboost model based on T2WI sequence and radiomics features of the tumor core region had the highest predictive efficacy with accuracy and AUC values of 67%and 0.74,respectively,higher than those of other combinations of sequences,models and regions of interest.Conclusion The multimodal MRI-based machine learning models can be used for the prediction of glioblastoma multiforme MGMT promoter methylation states,which provides powerful support for personalized treatment and prognostic assessment of GBM.[Chinese Medical Equipment Journal,2025,46(6):7-13]
6.Effect of different decompression methods on unilateral biportal endoscopy in the treatment of elderly patients with severe lumbar spinal stenosis
Zhi-long ZHANG ; Hai-ying WANG ; Feng-hua MA ; Yan-jie HOU
Journal of Regional Anatomy and Operative Surgery 2025;34(9):780-784
Objective To investigate the effect of different decompression methods on the efficacy of the unilateral biportal endoscopy(UBE)in the treatment of severe lumbar spinal stenosis(LSS).Methods A total of 203 elderly patients with LSS who underwent UBE treatment in our hospital from September 2021 to June 2024 were selected and divided into the unilateral group(102 cases)and the bilateral group(101 cases)according to different decompression methods.The unilateral group underwent unilateral decompression during operation,while the bilateral group underwent bilateral decompression(with bilateral decompression through the same incision and unilateral approach)during operation.The perioperative conditions,anatomical image parameters,visual analogue scale(VAS)scores,Oswestry disability index(ODI),and complications were compared between the two groups.The rehabilitation progress and complications of patients with different Charlson comorbidity index(CCI)values were compared.Results The operation time of patients in the bilateral group was longer than that in the unilateral group(P<0.05).The dural sac area and lumbar spinal canal area of patients in the bilateral group were larger than those in the unilateral group immediately after operation and 3 months after operation(P<0.05).The VAS scores and ODI 7 days and 3 months after operation of patients in the bilateral group were lower than those in the unilateral group(P<0.05).There was no statistically significant difference in the total incidence of complications between the two groups of patients(P>0.05).The first time of getting out of bed after operation and hospital stay in patients with CCI value>2 scores were longer than those in patients with CCI value≤2 scores(P<0.05).Conclusion Compared with unilateral decompression,bilateral decompression for elderly patients with severe LSS takes a longer surgical time,but it can better restore lumbar shape,alleviate pain,improve lumbar function,and has higher safety,and the milder the patient's condition,the faster the postoperative recovery.
7.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
8.Comparison of differences in dosimetry and treatment efficiency of modified radiotherapy plans after left-sided breast-conserving surgery
Jian-hai LIN ; Jing FENG ; Zhong-hua CHEN ; Zhi-chao FU ; Jie CHEN ; Nan-bao ZHONG
Chinese Medical Equipment Journal 2025;46(4):45-51
Objective To compare the differences in dosimetry and treatment efficiency of three radiotherapy plans after left-sided breast-conserving surgery,including modified intensity-modulated radiation therapy(IMRT),cross-field volume-modulated arc therapy(VMAT)or improved VMAT,so as to provide references for clinical practice.Methods Three radiotherapy plans of modified IMRT,cross-field VMAT and improved VMAT were designed for 12 patients after left-sided-breast-conserving surgery.The modified IMRT with five irradiation fields and the improved VMAT with two arcs were modified by not setting cross-fields while determining the start and end angles with the rays passing through the least lung area.The cross-field VMAT had its start and end angles set based on the cross-fields.The doses to the target areas,peripheral organs at risk,heart and its substructures were evaluated,and dose verification was carried out.The three plans were compared in terms of treatment efficiency and gamma pass rate.SPSS 22.0 was used for statistical analysis.Results All the three plans behaved well in dose distribution.In terms of planning gross tumor volume dosimetry dosimetry,the improved VMAT and modified IMRT gained advantages than others in CI and D50,respectively,with the differences being significant(all P<0.05).In terms of planning target volume dosimetry,the modified IMRT had the V107 and D50 lower than those of the others,with the differences being significant(P<0.05).In terms of the protection of peripheral organs at risk,V5 of the left lung,Dmean of the right lung and Dmean of the healthy breast were lower in the modified IMRT plan than in the other 2 plans,with statistically significant differences(P<0.05);V20,V30,V35 and V40 of the left lung were lower in the modified VMAT plan than in the other 2 plans,with statistically significant differences(P<0.05).In terms of protection of heart and its substructures,the left ventricle V20,V30 and Dmean of the improved VMAT plan behaved better than those of other 2 plans,and the difference was statistically significant(all P<0.05).In terms of treatment efficiency,the cross-field VMAT plan had the lowest MU while highest treatment efficiency;the improved VMAT plan had the MU higher while the treatment efficiency lower than the cross-field VMAT plan;the modified IMRT plan had the highest MU while the lowest gamma pass rate,and the differences in the MUs and gamma pass rates among the three plans were statistically significant(P<0.05).Conclusion Under the same standard conditions,the cross-field VMAT and improved VMAT plans show technical advantages.Though the improved VMAT plan has the treatment efficiency lower than the cross-field VMAT,it decreases the possibility of radiocardiac injury in terms of dosimetry and thus can be used for radiotherapy after left-sided breast-conserving surgery.[Chinese Medical Equipment Journal,2025,46(4):45-51]
9.Quality evaluation of Hibisci Mutabilis Folium based on fingerprint and quantitative analysis of multi-components by single-marker method.
Ming CHEN ; Zhen-Hai YUAN ; Xuan TANG ; Dong WANG ; Zhi-Yong ZHENG ; Jing FENG ; Dai-Zhou ZHANG ; Fang WANG
China Journal of Chinese Materia Medica 2025;50(16):4619-4629
To improve the quality evaluation system of Hibisci Mutabilis Folium, this study established high performance liquid chromatography(HPLC) fingerprints of Hibisci Mutabilis Folium and evaluated the quality differences of medicinal materials from different places of production by chemometrics. Furthermore, a content measurement method of differential components was established based on quantitative analysis of multi-components by single-marker(QAMS). The fingerprints of 17 batches of Hibisci Mutabilis Folium from different places of production were constructed, with a total of 19 common peaks marked and seven components confirmed. The similarity between the sample fingerprints and the reference fingerprints ranged from 0.890 to 0.974. By utilizing principal component analysis(PCA), hierarchical cluster analysis(HCA), and orthogonal partial least squares-discriminant analysis(OPLS-DA), the chemical patterns of fingerprints were identified. Five components that could be used to evaluate the quality differences of Hibisci Mutabilis Folium were screened, namely peak 6(quercetin 3-O-β-robinobioside), peak 7(rutin), peak 9(kaempferol-3-O-β-robinobioside), peak 10(kaempferol-3-O-rutinoside), and peak 14(tiliroside). The relative correction factors of isoquercitrin, kaempferol-3-O-β-robinobioside, kaempferol-3-O-rutinoside, kaempferol-3-O-β-D-glucoside, and tiliroside were measured with rutin as the internal reference. The QAMS method was established for the content measurement of six flavonoids, and the results showed there was no significant difference compared to the results obtained by an external standard method. In summary, the HPLC fingerprints and QAMS method established in the study, demonstrating stability and accuracy, can provide a reference for the overall quality evaluation of Hibisci Mutabilis Folium.
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Principal Component Analysis
10.STUDY ON EFFICACY OF COCKROACH CONTROL AND PATHOGENIC BACTERIA INFECTION ON AIRCRAFT
Jin-Hui FAN ; Zhi SHI ; Yan-Min QI ; Jian WU ; Xiao-Long ZHANG ; Wei-Nian PENG ; Hai-Feng WANG ; Yin-Juan DUAN ; Li-Li LI ; Jun-Jie HU
Acta Parasitologica et Medica Entomologica Sinica 2025;32(1):22-26
Objective This study aimed to provide an effective scientific basis for prevention and control of cockroaches on aircrafts by identifying cockroach-carried pathogens,and assess the insecticidal efficacy of gel bait mediated cockroach control on aircrafts,to provide technical guidance for aircraft disinsection.Methods Cassette-trapping was used to trap cockroaches,and the carried pathogens were detected using bacterial cultivation techniques.The gel bait mediated killing rate was calculated after 1,7,and 30 d by field application of gel bait.Results A total of 411 cockroaches were captured,and all were identified as Blattella germanica.26 strains of pathogenic bacteria were isolated from the trapped cockroaches.The killing rates of cockroaches were 58.8%-96.3%with 1-30 day application of gel bait.Statistically significant differences were observed in cockroach killing rates on different days(χ2=58.95,P<0.01).Conclusions B.germanica carry a large variety of pathogenic bacteria and opportunistic pathogens and are thus important infectious disease carriers.Gel bait agents have proven to be very effective against cockroaches on aircrafts.

Result Analysis
Print
Save
E-mail