1.Cross lag analysis of cumulative ecological risk and future orientation with health risk behaviors among higher vocational college students
ZENG Zhi, FU Gang, LI Ke, WANG Meifeng, WU Lian, ZHANG Tiancheng, ZHANG Fulan
Chinese Journal of School Health 2025;46(3):348-352
Objective:
To explore the causal link of cumulative ecological risk and future orientation with health risk behaviors among higher vocational college students, so as to provide reference for reducing and preventing health risk behaviors among higher vocational college students.
Methods:
A longitudinal follow up study was conducted on 612 students using convenience sampling from 2 vocational colleges in Hunan Province. The Cumulative Ecological Risk Scale, Future Orientation Scale, and Health Risk Behavior Scale were used during three follow up visits (T1: September 2022, T2: June 2023, T3: March 2024), and a cross lagged panel model was constructed to examine the longitudinal causal relationship of cumulative ecological risk, future orientation and health risk behaviors. Analysis of longitudinal intermediary effect between variables by Bootstrap.
Results:
The cumulative ecological risk scores of T1, T2 and T3 among higher vocational college students were (2.94±1.44,2.99±1.63,3.02±1.54), future orientation scores (40.49±4.71,41.51±5.72,41.06±4.35) and health risk behavior scores (3.73±2.01,3.49±2.00,3.23±2.00). The results of repeated measures ANOVA showed that the future orientation score of T2 was higher than that of T1, and the main effect of measurement time was statistically significant ( F=5.09,P<0.01,η 2=0.02). The health risk behavior score of T1 was higher than that of T2, and the health risk behavior score of T2 was higher than that of T3, and the main effect of measurement time was statistically significant ( F=10.12,P<0.01,η 2=0.03).The cross lagged model showed good adaptability, with χ 2/df =7.20 ( P <0.01), relative fitting indicators GFI=0.98, CFI=0.99, TLI=0.96, IFI=0.99, NFI =0.99, and absolute fitting indicator RMSEA =0.06. Among them, the T1, T2 cumulative ecological risk showed negatively predictive effects on T2, T3 future orientation ( β =-0.24, -0.47 ), and T1, T2 cumulative ecological risk positively predicted T2, T3 health risk behavior ( β =0.20, 0.24), while T1, T2 future orientation negatively predicted T2, T3 health risk behavior ( β =-0.25, -0.18) ( P <0.01). Bootstrap test analysis found that T2 future orientation had a longitudinal mediating effect ( β=0.04, P <0.01) on the T1 cumulative ecological risk and T3 health risk behavior.
Conclusions
The accumulation of ecological risk among higher vocational college students can positively predict health risk behaviors, while future orientation can negatively predict healthrisk behaviors. Moreover, future orientation plays a longitudinal mediating role between accumulated ecological risks and health risk behaviors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Molecular mechanism of verbascoside in promoting acetylcholine release of neurotransmitter.
Zhi-Hua ZHOU ; Hai-Yan XING ; Yan LIANG ; Jie GAO ; Yang LIU ; Ting ZHANG ; Li ZHU ; Jia-Long QIAN ; Chuan ZHOU ; Gang LI
China Journal of Chinese Materia Medica 2025;50(2):335-348
The molecular mechanism of verbascoside(OC1) in promoting acetylcholine(ACh) release in the pathogenesis of Alzheimer's disease(AD) was studied. Adrenal pheochromocytoma cells(PC12) of rats induced by β-amyloid protein(1-42)(Aβ_(1-42)) were used as AD models in vitro and were divided into control group, model group(Aβ_(1-42) 10 μmol·L~(-1)), OC1 treatment group(2 and 10 μg·mL~(-1)). The effect of OC1 on phosphorylated proteins in AD models was analyzed by whole protein phosphorylation quantitative omics, and the selectivity of OC1 for calcium channel subtypes was virtually screened in combination with computer-aided drug design. The fluorescence probe Fluo-3/AM was used to detect Ca~(2+) concentration in cells. Western blot analysis was performed to detect the effects of OC1 on the expression of phosphorylated calmodulin-dependent protein kinase Ⅱ(p-CaMKⅡ, Thr286) and synaptic vesicle-related proteins, and UPLC/Q Exactive MS was used to detect the effects of OC1 on ACh release in AD models. The effects of OC1 on acetylcholine esterase(AChE) activity in AD models were detected. The results showed that the differentially modified proteins in the model group and the OC1 treatment group were related to calcium channel activation at three levels: GO classification, KEGG pathway, and protein domain. The results of molecular docking revealed the dominant role of L-type calcium channels. Fluo-3/AM fluorescence intensity decreased under the presence of Ca~(2+) chelating agent ethylene glycol tetraacetic acid(EGTA), L-type calcium channel blocker verapamil, and N-type calcium channel blocker conotoxin, and the effect of verapamil was stronger than that of conotoxin. This confirmed that OC1 promoted extracellular Ca~(2+) influx mainly through its interaction with L-type calcium channel protein. In addition, proteomic analysis and Western blot results showed that the expression of p-CaMKⅡ and downstream vesicle-related proteins was up-regulated after OC1 treatment, indicating that OC1 acted on vesicle-related proteins by activating CaMKⅡ and participated in synaptic remodeling and transmitter release, thus affecting learning and memory. OC1 also decreased the activity of AChE and prolonged the action time of ACh in synaptic gaps.
Animals
;
Rats
;
Glucosides/administration & dosage*
;
Acetylcholine/metabolism*
;
Alzheimer Disease/genetics*
;
PC12 Cells
;
Phenols/chemistry*
;
Neurotransmitter Agents/metabolism*
;
Drugs, Chinese Herbal
;
Calcium-Calmodulin-Dependent Protein Kinase Type 2/genetics*
;
Humans
;
Phosphorylation/drug effects*
;
Calcium/metabolism*
;
Polyphenols
8.AI-Ready Competency Framework for Biomedical Scientific Data Literacy.
Zhe WANG ; Zhi-Gang WANG ; Wen-Ya ZHAO ; Wei ZHOU ; Sheng-Fa ZHANG ; Xiao-Lin YANG
Chinese Medical Sciences Journal 2025;40(3):203-210
With the rise of data-intensive research, data literacy has become a critical capability for improving scientific data quality and achieving artificial intelligence (AI) readiness. In the biomedical domain, data are characterized by high complexity and privacy sensitivity, calling for robust and systematic data management skills. This paper reviews current trends in scientific data governance and the evolving policy landscape, highlighting persistent challenges such as inconsistent standards, semantic misalignment, and limited awareness of compliance. These issues are largely rooted in the lack of structured training and practical support for researchers. In response, this study builds on existing data literacy frameworks and integrates the specific demands of biomedical research to propose a comprehensive, lifecycle-oriented data literacy competency model with an emphasis on ethics and regulatory awareness. Furthermore, it outlines a tiered training strategy tailored to different research stages-undergraduate, graduate, and professional, offering theoretical foundations and practical pathways for universities and research institutions to advance data literacy education.
Artificial Intelligence
;
Humans
;
Biomedical Research
9.Orthopedic manipulation combined with percutaneous reduction and Kirschner wire internal fixation for Sanders typeⅡand Ⅲ calcaneal fractures.
Feng DAI ; Jin-Tao LIU ; Zhi-Gang ZHANG ; Xue-Qiang SHEN ; Li-Ming WU ; Peng-Fei YU ; Hong JIANG
China Journal of Orthopaedics and Traumatology 2025;38(3):306-310
OBJECTIVE:
To explore clinical effects of bone setting manipulation combined with pry reduction and Kirschner needle internal fixation in treating SandersⅡ-Ⅲ calcaneal fracture.
METHODS:
Clinical data of 52 patients with types Sanders Ⅱand Ⅲ calcaneal fracture (foot) treated with bone-setting manipulation combined with pry reduction and Kirscher needle internal fixation from July 2017 to July 2019 were retrospectively analyzed, including 43 males and 9 females, aged from 31 to 72 years old with an average of (50.83±10.48) years old; 15 patients with Sanders typeⅡ and 37 patients with Sanders type Ⅲ. The changes of Bühler angle, Gissane angle, calcaneus width and calcaneus height before operation and 24 months after operation were compared, and Maryland foot function score was performed to evaluate clinical effects.
RESULTS:
All patients were followed up from 24 to 60 months with an average of (41.50±9.86)months. The fracture healed normally and the healing time was (11.00±0.95) weeks. Bühler angle, Gissane angle, calcaneal bone width and calcaneal bone height were increased from (16.37±8.36)°, (96.27±9.62)°, (46.82±4.67) mm, (38.41±3.58) mm before operation to (31.48±8.24)°, (111.62±8.69)°, (42.06±4.83) mm, (44.21±3.82) mm at 24 months after operation, and the difference were statistically significant (P<0.01). Postoperative Maryland score at 24 months was (93.04±8.83), 40 patients got excellent result, 7 good and 5 fair.
CONCLUSION
Orthopedic manipulation combined with percutaneous reduction and Kirschner wire internal fixation could significantly improve Bühler angle, Gissane angle, width, and height of Sanders typeⅡ and Ⅲ calcaneal fractures, and the curative effect is satisfactory.
Humans
;
Male
;
Female
;
Calcaneus/surgery*
;
Middle Aged
;
Fracture Fixation, Internal/methods*
;
Adult
;
Aged
;
Fractures, Bone/therapy*
;
Retrospective Studies
;
Bone Wires
;
Manipulation, Orthopedic/methods*
10.Clinical efficacy of endocrinotherapy combined with Shenqi Pills on patients with hormone-sensitive prostate cancer.
Yu-Hong XIE ; Gang YI ; Xiao-Wen YI ; Tong-Lin SUN ; Qun-Fang LIN ; Jun ZHOU ; Xin-Jun LUO ; Fang-Zhi FU ; Biao WANG ; Qin-Zheng WANG ; Lie ZHANG ; Yang YANG ; Rui-Song GAO ; Qing ZHOU
National Journal of Andrology 2025;31(4):341-348
OBJECTIVE:
The aim of this study is to explore the clinical efficacy and safety of endocrinotherapy combined with Shenqi Pills on hormone-sensitive prostate cancer (HSPC).
METHODS:
Eighty patients who were diagnosed with HSPC and renal-yang deficiency at the First Affiliated Hospital of Hunan University of Traditional Chinese Medicine and the Hospital of Traditional Chinese Medicine of Mayang Miao Autonomous County from 1st April 2021 to 30th April 2024 were randomly divided into 2 groups. The patients in the control group were treated with androgen deprivation therapy (ADT). And the patients in treatment group were treated with Shenqi Pills orally on the basis of the control group. The baseline data of the two groups were analyzed. After 36 months of treatment, the differences between the two groups were compared in terms of overall survival (OS), prostate-specific antigen (PSA) level, PSA response rate, Functional Assessment Scale for Prostate Cancer Therapy (FACT-P), Chinese medicine evidence scores, testosterone level and safety.
RESULTS:
A total of 80 study subjects were included in this study, including 42 cases in the treatment group and 38 cases in the control group. There was no statistical difference in the baseline data between the two groups before treatment (P>0.05). At the end of the observation period, a statistically significant difference in OS was found in the treatment group compared to the control group in the subgroup of patients with a disease duration ranged of 0-6 months (P<0.05). There was no statistically significant difference in PSA levels in the treatment group at 3 months (P>0.05). And the differences in the proportion of PSA50 (98.1% vs 91.4%), PSA90 (92.9% vs 84.6%) and the proportion of decrease in PSA (56.7% vs 33.8%) in the treatment group were found compared to those in the control group after 6 months of tre atment. After 12 months of treatment, the scores of FACT-4 and renal-yang deficiency in the treatment group were (95.28±7.93) and (15.73±5.70) respectively, compared to the scores in the control group ([85.46±10.12] and [18.20±4.27] (P<0.05). However, there was no significant difference in serum testosterone ([0.60±0.24] nmol/L vs [1.09±2.10] nmol/L) between the two groups (P>0.05). After 24 months of treatment, there were significant differences in in the FACT-4 total score ([97.95±7.54] vs [80.33±8.58]), renal-yang deficiency syndrome score ([14.64±5.15] vs [24.94±8.75]) between the treatment group and the control group (P<0.05). However, there was no significant difference in serum testosterone ( [0.73±1.01] nmol/L vs [0.59±0.25] nmol/L) between the two groups (P> 0.05). Better therapeutic results were showed in the treatment group in terms of total FACT-P score, physical situation score, social and family situation score, emotional state score, functional state score, additional score and renal-yang deficiency symptom score (P<0.05). After treatment, there was no serious adverse reaction in the course of treatment, and no obvious abnormality was found in the liver and kidney function of the patients from two groups.
CONCLUSION
Endocrinotherapy combined with Shenqi Pills is safe and effective in HSPC and can reduce the risk of death in HSPC patients, and the earlier the intervention, the longer the overall survival of the patients. In addition, this treatment regimen can increase the PSA response rate, improve patients' quality of life, and reduce the renal-yang deficiency syndrome score without the risk of elevating serum testosterone levels.
Humans
;
Male
;
Drugs, Chinese Herbal/therapeutic use*
;
Prostatic Neoplasms/drug therapy*
;
Androgen Antagonists/therapeutic use*
;
Prostate-Specific Antigen/blood*
;
Aged
;
Middle Aged
;
Treatment Outcome
;
Testosterone


Result Analysis
Print
Save
E-mail