1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Four new sesquiterpenoids from the roots of Atractylodes macrocephala
Gang-gang ZHOU ; Jia-jia LIU ; Ji-qiong WANG ; Hui LIU ; Zhi-Hua LIAO ; Guo-wei WANG ; Min CHEN ; Fan-cheng MENG
Acta Pharmaceutica Sinica 2025;60(1):179-184
The chemical constituents in dried roots of
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Recommendations for the clinical use of anti-amyloid-β monoclonal antibody for Alzheimer's disease(2025)
Nan ZHI ; Jinwen XIAO ; Rujing REN ; Binyin LI ; Jintao WANG ; Jieli GENG ; Wenwei CAO ; Yaying SONG ; Hualong WANG ; Shuguang CHU ; Guoping PENG ; Jun LIU ; Xiaoyun LIU ; Fang YUAN ; Wen WANG ; Ronghua DOU ; Xia LI ; Ling YUE ; Wenshi WEI ; Xiaoling PAN ; Xiangyang ZHU ; Dian HE ; Weinü FAN ; Jingping SHI ; Nan ZHANG ; Hui ZHAO ; Qin CHEN ; Cuibai WEI ; Xiaochun CHEN ; Gang WANG
Journal of Chongqing Medical University 2025;50(9):1133-1140
In recent years,significant breakthroughs have been achieved in the immunotherapy for Alzheimer's disease.In line with global advancements,two anti-amyloid-β monoclonal antibodies have been approved and successfully launched in China for clinical use.Lecanemab and Donanemab were officially used in June 2024 and April 2025 in China,respectively.In order to standardize the rational and safe application of anti-amyloid-β monoclonal antibodies for Alzheimer's disease in China,this article integrates recom-mendations from the clinical trials and real-world experience from the author's team and domestic peers to further update the recom-mendations for the clinical use of anti-amyloid-β monoclonal antibody based on the 2024 version.It includes indications for therapy,pre-treatment evaluation and preparation,administration protocols and safety measures during treatment,and post-treatment monitor-ing strategies.
8.Protective effects of Tongxie Yaofang on intestinal mucosa in rats with ulcerative colitis due to Liver Depression and Spleen Deficiency Pattern
Li-Hui FAN ; Xiang-Dong ZHU ; Zhi-Gang WANG ; Xia YANG
Chinese Traditional Patent Medicine 2024;46(7):2189-2195
AIM To explore the protective effects of Tongxie Yaofang on the intestinal mucosa of rats with ulcerative colitis(UC)due to Liver Depression and Spleen Deficiency.METHODS The rats were randomly divided into the blank group,the model group,the mesalazine group(0.4 g/kg),the high-dose,medium-dose and low-dose Tongxie Yaofang groups(20.8,10.4,5.2 g/kg).The rat models were induced by DNBS/ethanol solution enema,restraint stress and inappropriate diet.All rats had their serum levels of IL-8 and TNF-α detected by ELISA;their colonic pathological changes observed by HE staining;and their colonic TLR4,MyD88 and NF-κB p65 mRNA and protein expressions detected by RT-qPCR,Western blot and immunohistochemistry method.RESULTS Compared with the model group,all theother groups intervened with the medical agents displayed lower serum levels of TNF-a and IL-8(P<0.05,P<0.01);decreased colonic expressions of MyD88 and NF-κB p65 mRNA and protein(P<0.05,P<0.01).The mesalazine group and the high-dose and medium-dose Tongxie Yaofang groups shared decreased colonic expression of TLR4 mRNA and protein(P<0.05,P<0.01);and the low-dose Tongxie Yaofang group demonstrated decreased colonic TLR4 protein expression(P<0.05).CONCLUSION Tongxie Yaofang may inhibit the inflammatory reaction of the rats and repair their intestinal mucosal barrier damage via TLR4/MyD88/NF-κB signal pathway.
9.IgA nephropathy with mesangial type Ⅲ collagen deposition:2 cases report
Jie-Bo HUANG ; Xiao-Fan CAI ; Zhong-Hua ZHAO ; Zhi-Gang ZHANG ; Qiang SHEN ; Hao WANG ; Hui-Juan WU
Fudan University Journal of Medical Sciences 2024;51(3):426-430
As interstitial collagen,type Ⅲ collagen(Col Ⅲ)does not express in normal glomeruli.However,in Col Ⅲ nephropathy,a large amount of Col Ⅲ deposit in the mesangial and subendothelial area of the glomeruli.IgA nephropathy with Col Ⅲ deposition was extremely rare.In this article,we reported two cases of such disease.After treating with immunosuppressive agents or traditional Chinese medicine decoction,the renal function of the two patients remained stable and the urinary protein levels reduced significantly.
10.Reconstruction of Allen's type IV fingertip amputation via bilateral unequal-sized hallux osteo-onychocutaneous free flaps: A retrospective study with 5-year follow-up
Xiu-Zhong LI ; Xiu-Yun WANG ; Yi-Min ZHOU ; Da-Zhi YU ; Hua-Gang ZHANG ; Shu-Jian HOU ; Ke-Cheng LAO ; Xiao FAN
Chinese Journal of Traumatology 2024;27(6):403-409
Purpose::The reconstruction of Allen's type IV fingertip amputation is a clinical challenge. Our team designed bilateral unequal-sized hallux osteo-onychocutaneous free flaps for the long-term reconstruction of Allen's type IV fingertip amputation and conducted a retrospective study with a 5-year follow-up aims to evaluate the effects of this technique.Methods::A retrospective analysis with a 5-year follow-up including 13 patients with Allen's type IV fingertip amputation who were admitted to our hospital from January 2010 to January 2017 was conducted. The patients were treated with bilateral unequal-sized hallux osteo-onychocutaneous free flaps. The operation time, intraoperative blood loss, and complications were recorded, and the survival rate of the transplanted flaps was calculated. During the 5-year follow-up after operation, the nail growth time was recorded and the finger appearance was observed. At the last follow-up appointment, the length, width, and girth of the reconstructed fingertip and contralateral normal fingertip, range of motion of the reconstructed fingertip and contralateral normal fingertip, Semmes-Weinstein test (for the evaluation of tactile sensation), and two-point discrimination testing results were recorded. SPSS 22.0 software was used for the statistical analysis and the data are presented as mean ± SD.Results::The mean operation time was (5.62 ± 0.51) h, the mean intraoperative blood loss was (34.15 ± 3.13) mL, and the survival rate of the transplanted flaps was 100%. During the 5-year follow-up, the average nail growth time was (10.14 ± 1.98) months and the average bone union time was (3.78 ± 0.91) months. The length, width, and girth of the reconstructed fingertip were (31.52 ± 3.73) mm, (17.82 ± 1.74) mm, and (59.75 ± 3.04) mm, respectively, which did not differ from those of the contralateral normal fingertip. The range of motion of the reconstructed fingertip was (12.15 ± 2.79) degrees which is different from that of the contralateral normal fingertip. The average tactile sensation evaluated via the Semmes-Weinstein test and the average two-point discrimination test of the reconstructed fingertip were (0.39 ± 0.17) g and (7.46 ± 1.14) mm, respectively, which were not different from those of the contralateral normal fingertip. The average Maryland score of feet in the donor area was 87.66 ± 7.39, which was satisfactory.Conclusion::Bilateral unequal-sized hallux osteo-onychocutaneous free flaps are an effective method to reconstruct Allen's type IV fingertip amputations with a satisfactory appearance and good sensory function.

Result Analysis
Print
Save
E-mail