1.Current situation of medicinal animal breeding and research progress in sustainable utilization of resources.
Cheng-Cai ZHANG ; Jia WANG ; Yu-Jie ZHOU ; Xiao-Yu DAI ; Xiu-Fu WAN ; Chuan-Zhi KANG ; De-Hua WU ; Jia-Hui SUN ; Sheng WANG ; Lan-Ping GUO
China Journal of Chinese Materia Medica 2025;50(16):4397-4406
Traditional Chinese medicine(TCM) is the pillar for the development of motherland medicine, and animal medicine has a long history of application in China, characterized by wide resources, strong activity, definite efficacy, and great benefits. It has significant potential and important status in the consumption market of raw materials of TCM. In the context of global climate change, farming system alterations, and low renewability, the depletion of wild medicinal animal resources has accelerated. Accordingly, the conservation and sustainable utilization of wild resources of animal medicinal materials has become a problem that garners increasing attention and urgently needs to be solved. This paper summarizes the current situation of domestic and foreign medicinal animal breeding and research progress in industrial application in recent years and points out the issues related to standardized breeding, germplasm selection and breeding, and quality evaluation standards for medicinal animals. Furthermore, this paper discusses standardized breeding, quality standards, resource protection and utilization, and the search for alternative resources for rare and endangered medicinal animals. It proposes that researchers should systematically carry out in-depth basic research on animal medicine, improve the breeding scale and level of medicinal animals, employ modern technology to enhance the quality standards of medicinal materials, and strengthen the research and development of alternative resources. This approach aims to effectively address the relationship between protection and utilization and make a significant contribution to the sustainable development of medicinal animal resources and the animal-based Chinese medicinal material industry.
Animals
;
Breeding
;
China
;
Medicine, Chinese Traditional
;
Conservation of Natural Resources
2.Multicolor Fluorescent Copper Nanoclusters/Starch Composites and Their Application in Fingermark Development
Chuan-Jun YUAN ; Ming LI ; Yi-Fei SUN ; Jia-Ming LYU ; Zhi-Bo GAO ; Shi-Qiang SUN ; Pei-Liang HAN ; Feng-He LIU
Chinese Journal of Analytical Chemistry 2025;53(1):55-64,中插1-中插3
On the basis of that the fluorescence wavelength of copper nanoclusters(CuNCs)could cover the entire visible region,multicolor fluorescent CuNCs/starch composites were prepared and applied in fingermark development.With L-glutathione as the reducing agent and protective ligand,blue emissive and orange emissive CuNCs solutions were obtained in alkaline solutions at 90℃and 25℃,respectively.With the aggregation-induced emission effect induced by ethanol as a poor solvent,the fluorescence of orange emissive CuNCs with a higher intensity was achieved in an ethanol-water solution.With ascorbic acid as the reducing agent and 3-mercaptopropionic acid as the protective agent,green emissive CuNCs solution was prepared in an acid solution.Particle morphologies,chemical compositions and optical properties of these three CuNCs above were investigated using physical characterization and spectroscopic analysis,indicating that well-dispersed CuNCs had excellent photoluminescent properties.These CuNCs solutions were combined with starch to form composite powders by simply drying.The influences of the type of CuNCs and the ratio of CuNCs to starch on the emission wavelength and fluorescence intensity of the products were studied.The obtained CuNCs/starch composites could emit blue,green and orange fluorescence under 365 nm ultraviolet light,respectively,which were suitable for fingermark development.Minutiae and partial level-3 features of latent fingermarks could be effectively developed.High-quality fluorescence fingermark images would be captured using appropriate optical filters to eliminate background interference of various substrates.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Explore the Application of Logistic Regression Model Based on Energy Spectral CT Parameters and Clinical Parameters Characteristics in the Diagnosis of Benign and Malignant Pulmonary Ground Glass Nodules
Fei MA ; Qing-sheng SUN ; Zhi-chuan YE ; Huai LI
Progress in Modern Biomedicine 2025;25(13):2201-2207
Objective:To construct a Logistic regression model based on the energy spectral computed tomography(CT)parameters and clinical parameters characteristics,and to evaluate its diagnostic efficacy in the benign and malignant pulmonary ground glass nodules(GGN).Methods:162 GGN patients who were admitted to our hospital from April 2022 to March 2024 were selected,they were divided into benign group and malignant group according to pathological results.The difference of CT parameters[water content in normal scan period,water content in arterial period,slope of energy spectral curve in normal scan period and k value in arterial period]and clinical data between the two groups was compared.Multivariate Logistic regression model was used to analyze the independent influencing factors of malignant GGN.Receiver operating characteristic(ROC)curve was used to evaluate the diagnostic efficacy of the model for malignant GGN.Results:Water content in normal scan period in malignant group was significantly higher than that in benign group(P<0.05).k value in normal scan period in the malignant group was significantly higher than that in the benign group(P<0.05).Water content in arterial period in malignant group was higher than that in benign group(P<0.05).k value in arterial period in the malignant group was higher than in benign group(P<0.05).There were significant differences in smoking history,family history of tumor and chronic obstructive pulmonary disease(COPD)between benign group and malignant group(P<0.05).Multivariate Logistic regression model analysis showed that,water content in normal scan period,k value in normal scan period,k value in arterial period,water content in arterial period,smoking history and family history of tumor were independent influencing factors of malignant nodule in GGN patients(P<0.05).Based on the results of multi-factor Logistic regression analysis,the Logistic regression prediction model was constructed:logit(P)=ln(P/l-P)=0.015× water content in arterial period+1.214× smoking history+1.506× family history of tumor+0.013× water content in normal scan period 0.553× k value in normal scan period+0.202 × k value in arterial period.ROC curve results showed that the area under the curve(AUC)of the combined prediction model was 0.852,which was significantly higher than 0.654,0.607,0.628,0.759,0.707,0.682 of water content in normal scan period,k value in normal scan period,k value in arterial period,water content in arterial period,smoking history and family history of tumor.Conclusion:The Logistic regression model constructed based on the characteristics of energy spectral CT parameters and clinical parameters characteristics has good diagnostic efficacy for benign and malignant GGN.
9.Explore the Application of Logistic Regression Model Based on Energy Spectral CT Parameters and Clinical Parameters Characteristics in the Diagnosis of Benign and Malignant Pulmonary Ground Glass Nodules
Fei MA ; Qing-sheng SUN ; Zhi-chuan YE ; Huai LI
Progress in Modern Biomedicine 2025;25(13):2201-2207
Objective:To construct a Logistic regression model based on the energy spectral computed tomography(CT)parameters and clinical parameters characteristics,and to evaluate its diagnostic efficacy in the benign and malignant pulmonary ground glass nodules(GGN).Methods:162 GGN patients who were admitted to our hospital from April 2022 to March 2024 were selected,they were divided into benign group and malignant group according to pathological results.The difference of CT parameters[water content in normal scan period,water content in arterial period,slope of energy spectral curve in normal scan period and k value in arterial period]and clinical data between the two groups was compared.Multivariate Logistic regression model was used to analyze the independent influencing factors of malignant GGN.Receiver operating characteristic(ROC)curve was used to evaluate the diagnostic efficacy of the model for malignant GGN.Results:Water content in normal scan period in malignant group was significantly higher than that in benign group(P<0.05).k value in normal scan period in the malignant group was significantly higher than that in the benign group(P<0.05).Water content in arterial period in malignant group was higher than that in benign group(P<0.05).k value in arterial period in the malignant group was higher than in benign group(P<0.05).There were significant differences in smoking history,family history of tumor and chronic obstructive pulmonary disease(COPD)between benign group and malignant group(P<0.05).Multivariate Logistic regression model analysis showed that,water content in normal scan period,k value in normal scan period,k value in arterial period,water content in arterial period,smoking history and family history of tumor were independent influencing factors of malignant nodule in GGN patients(P<0.05).Based on the results of multi-factor Logistic regression analysis,the Logistic regression prediction model was constructed:logit(P)=ln(P/l-P)=0.015× water content in arterial period+1.214× smoking history+1.506× family history of tumor+0.013× water content in normal scan period 0.553× k value in normal scan period+0.202 × k value in arterial period.ROC curve results showed that the area under the curve(AUC)of the combined prediction model was 0.852,which was significantly higher than 0.654,0.607,0.628,0.759,0.707,0.682 of water content in normal scan period,k value in normal scan period,k value in arterial period,water content in arterial period,smoking history and family history of tumor.Conclusion:The Logistic regression model constructed based on the characteristics of energy spectral CT parameters and clinical parameters characteristics has good diagnostic efficacy for benign and malignant GGN.
10.Loss of TET Activity in the Postnatal Mouse Brain Perturbs Synaptic Gene Expression and Impairs Cognitive Function.
Ji-Wei LIU ; Ze-Qiang ZHANG ; Zhi-Chuan ZHU ; Kui LI ; Qiwu XU ; Jing ZHANG ; Xue-Wen CHENG ; Han LI ; Ying SUN ; Ji-Jun WANG ; Lu-Lu HU ; Zhi-Qi XIONG ; Yongchuan ZHU
Neuroscience Bulletin 2024;40(11):1699-1712
Conversion of 5-methylcytosine (5mC) to 5-hydroxymethylcytosine (5hmC) by ten-eleven translocation (TET) family proteins leads to the accumulation of 5hmC in the central nervous system; however, the role of 5hmC in the postnatal brain and how its levels and target genes are regulated by TETs remain elusive. We have generated mice that lack all three Tet genes specifically in postnatal excitatory neurons. These mice exhibit significantly reduced 5hmC levels, altered dendritic spine morphology within brain regions crucial for cognition, and substantially impaired spatial and associative memories. Transcriptome profiling combined with epigenetic mapping reveals that a subset of genes, which display changes in both 5hmC/5mC levels and expression patterns, are involved in synapse-related functions. Our findings provide insight into the role of postnatally accumulated 5hmC in the mouse brain and underscore the impact of 5hmC modification on the expression of genes essential for synapse development and function.
Animals
;
Brain/growth & development*
;
5-Methylcytosine/metabolism*
;
Mice
;
Synapses/genetics*
;
Proto-Oncogene Proteins/metabolism*
;
DNA-Binding Proteins/metabolism*
;
Dioxygenases/metabolism*
;
Cognition/physiology*
;
Gene Expression
;
Mixed Function Oxygenases/metabolism*
;
Epigenesis, Genetic
;
Mice, Knockout
;
Mice, Inbred C57BL

Result Analysis
Print
Save
E-mail