1.Three-dimensional Electrical Impedance Tomography for Monitoring Gastric Hemorrhage
Zi-Han ZHAO ; Bo SUN ; Jing-Shi HUANG ; Zhi-Wei LI ; Yang WU ; Nan LI ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2026;53(4):1062-1075
ObjectiveGastric hemorrhage is one of the most common and life-threatening emergencies of the upper digestive tract. Early identification and continuous monitoring are essential for reducing rebleeding rates and mortality, particularly within the critical early hours after onset. Although endoscopy and radiological imaging can accurately localize bleeding sites, these approaches are invasive, resource-intensive, and unsuitable for continuous bedside monitoring. Electrical impedance tomography (EIT), as a noninvasive and radiation-free functional imaging technique, offers real-time visualization of conductivity distribution and has the potential for detecting intragastric bleeding based on the electrical contrast between blood and surrounding gastric tissues. In this study, a three-dimensional gastric EIT (3D-gEIT) framework is proposed to achieve noninvasive, real-time, and dynamic monitoring of gastric hemorrhage, with emphasis on spatial localization and quantitative volume assessment. MethodsA three-dimensional upper-abdominal simulation model incorporating the stomach, gastric wall, gastric contents, and surrounding tissues was established. Three electrode configurations, namely the dual layer ring, the four layer staggered ring, and the opposed dual plane array, were designed and systematically compared to evaluate their influence on depth sensitivity and spatial resolution. Based on the Tikhonov-Noser hybrid regularization scheme, a region-clustering constraint was introduced to develop the TK-Noser-RCC algorithm. This approach aggregates spatially adjacent elements with similar conductivity variations, thereby enhancing structural continuity and suppressing isolated noise artifacts. To validate the proposed framework, an upper-abdominal physical phantom was constructed using agar to simulate background tissue conductivity. Hemispherical high-conductivity inclusions with volumes ranging from 10 ml to 50 ml were attached to the inner gastric wall to mimic localized bleeding under different gastric filling states. Boundary voltages were acquired under a 120 kHz excitation current and reconstructed using the TK-Noser-RCC algorithm. Furthermore, an in vivo animal experiment was performed using a porcine model with adult-scale abdominal dimensions. A total of 100 ml of autologous blood was injected incrementally into the stomach to simulate progressive gastric hemorrhage, and time-difference EIT reconstruction was conducted at each injection stage to assess the dynamic system response under physiological conditions. ResultsSimulation results demonstrated that the opposed dual-plane electrode array achieved superior depth sensitivity distribution and spatial resolution. For a 40 ml hemorrhage model, the average ICC and SSIM improved by 55.9% and 38.8% compared with the dual-layer ring configuration, and by 64.0% and 39.5% compared with the four-layer staggered configuration. The proposed region-clustering constraint significantly enhanced reconstruction stability. Under added Gaussian noise of 40 dB and 30 dB, ICC values remained approximately 0.85, indicating effective artifact suppression and preservation of boundary integrity. In physical phantom experiments, reconstructed hemorrhage volumes increased approximately linearly with the preset hemispherical volumes, and the reconstructed high-conductivity regions closely matched the actual bleeding locations. Both empty-stomach and full-stomach conditions were evaluated, demonstrating that the opposed dual-plane configuration maintained stable imaging performance across varying gastric contents. In the animal experiment, reconstructed low-impedance regions expanded progressively with increasing injected blood volume. The spatial localization of the hemorrhage remained stable throughout the procedure, and no significant artifacts were observed. Quantitative analysis showed that reconstructed volume and average conductivity variation exhibited an approximately linear growth trend with injected blood volume, confirming the sensitivity of the system to dynamic intragastric conductivity changes. ConclusionThe proposed 3D-gEIT framework enables quantitative reconstruction of gastric hemorrhage volume and spatial distribution with improved depth sensitivity, structural continuity, and noise robustness compared with conventional EIT approaches. By integrating optimized electrode configuration and a region-clustering-constrained reconstruction algorithm, the system provides stable dynamic monitoring under both controlled phantom conditions and in vivo physiological environments. This method offers a noninvasive, real-time, and low-cost imaging strategy for early diagnosis, postoperative monitoring, and bedside surveillance of gastric bleeding.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Establishment and evaluation of a lipopolysaccharide-induced acute respiratory distress syndrome model in minipigs
Chuang-Ye WANG ; Ran WANG ; Jian ZHANG ; Ling-Xiao QIU ; Bin QING ; Heng YOU ; Jin-Cheng LIU ; Bin WANG ; Nan-Bo WANG ; Jia-Yu LI ; Xing LIU ; Shuang WANG ; Jin HU ; Jian WEN ; Quan LI ; Xiao-Ou HUANG ; Kun ZHAO ; Shuang-Lin LIU ; Gang LIU ; Mei-Ju WANG ; Qing XIANG ; Hong-Mei WU ; Xiao-Rong SUN ; Tao GU ; Dong ZHANG ; Qi LI ; Zhi XU
Medical Journal of Chinese People's Liberation Army 2025;50(9):1154-1161
Objective To establish a stable,reliable,and clinically relevant porcine model of endotoxin-induced acute respiratory distress syndrome(ARDS).Methods Ten 8-month-old male Bama minipigs were deeply sedated,followed by invasive mechanical ventilation and electrocardiographic monitoring.Lipopolysaccharide(LPS)was intravenously pumped at 600 μg/(kg·h)for 3 hours,then maintained at 15 μg/(kg·h)thereafter.Dynamic monitoring was performed at five time points after LPS injection(LPS 0,1,3,5,and 8 h),including arterial blood gas analysis and chest computed tomography(CT)scans.Pathological examination of lung tissues obtained via bronchoscopic biopsy(HE staining and transmission electron microscopy)was conducted.These indicators were comprehensively used to evaluate the success of the animal model.Results At 5 hours after LPS administration,8 minipigs developed symptoms such as skin cyanosis,elevated body temperature,and respiratory distress.The oxygenation index decreased to<300 mmHg.Chest CT scans showed diffuse pulmonary infiltrates.Histopathology revealed alveolar edema and hyaline membrane formation.Transmission electron microscopy demonstrated disruption of pulmonary blood-air barrier,depletion of lamellar bodies in type Ⅱ pneumocytes,inflammatory cell infiltration,and exudation of plasma proteins and fibrin.Compared with LPS 0 h,at LPS 8 h,the oxygenation index and arterial blood pH were significantly decreased(P<0.001),while blood lactic acid and serum potassium were significantly increased(P<0.05);serum calcium and base excess were significantly decreased(P<0.05),and the lung injury score based on HE-stained lung sections was significantly increased(P<0.01).Conclusion The porcine ARDS model established by continuous LPS injection can dynamically simulate the pathophysiological characteristics and typical pathological manifestations of clinical septic ARDS,making it an effective tool to study the pathogenesis,prevention,and treatment strategies of septic ARDS.
5.Research progress in exploring cognitive processes based on pupil changes
Xiao-Ting QIAO ; Zi-Wei NI ; Bo-Zhi LIU ; Ya-Qian GUO ; Yan ZHAO ; Cai-Lian RUAN ; Ya-Yun WANG
Acta Anatomica Sinica 2025;56(3):357-363
In recent years,more and more researches has focused on the correlation between cognitive activity and physiological variables.The change of pupil is regarded as an important target in the cognitive process,and has become a hot research field.This review focuses on the three key brain regions that regulate pupil change,and reflects the neurophysiological mechanism behind pupil change by elaborating the neural pathways related to pupil change and cognitive performance.Based on recent studies on pupil change in cognitive diseases,it aims to promote the application of pupil change in the field of cognitive science in the future.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Research on BP Neural Network Method for Identifying Cell Suspension Concentration Based on GHz Electrochemical Impedance Spectroscopy
An ZHANG ; A-Long TAO ; Qi-Hang RAN ; Xia-Yi LIU ; Zhi-Long WANG ; Bo SUN ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2025;52(5):1302-1312
ObjectiveThe rapid advancement of bioanalytical technologies has heightened the demand for high-throughput, label-free, and real-time cellular analysis. Electrochemical impedance spectroscopy (EIS) operating in the GHz frequency range (GHz-EIS) has emerged as a promising tool for characterizing cell suspensions due to its ability to rapidly and non-invasively capture the dielectric properties of cells and their microenvironment. Although GHz-EIS enables rapid and label-free detection of cell suspensions, significant challenges remain in interpreting GHz impedance data for complex samples, limiting the broader application of this technique in cellular research. To address these challenges, this study presents a novel method that integrates GHz-EIS with deep learning algorithms, aiming to improve the precision of cell suspension concentration identification and quantification. This method provides a more efficient and accurate solution for the analysis of GHz impedance data. MethodsThe proposed method comprises two key components: dielectric property dataset construction and backpropagation (BP) neural network modeling. Yeast cell suspensions at varying concentrations were prepared and separately introduced into a coaxial sensor for impedance measurement. The dielectric properties of these suspensions were extracted using a GHz-EIS dielectric property extraction method applied to the measured impedance data. A dielectric properties dataset incorporating concentration labels was subsequently established and divided into training and testing subsets. A BP neural network model employing specific activation functions (ReLU and Leaky ReLU) was then designed. The model was trained and tested using the constructed dataset, and optimal model parameters were obtained through this process. This BP neural network enables automated extraction and analytical processing of dielectric properties, facilitating precise recognition of cell suspension concentrations through data-driven training. ResultsThrough comparative analysis with conventional centrifugal methods, the recognized concentration values of cell suspensions showed high consistency, with relative errors consistently below 5%. Notably, high-concentration samples exhibited even smaller deviations, further validating the precision and reliability of the proposed methodology. To benchmark the recognition performance against different algorithms, two typical approaches—support vector machines (SVM) and K-nearest neighbor (KNN)—were selected for comparison. The proposed method demonstrated superior performance in quantifying cell concentrations. Specifically, the BP neural network achieved a mean absolute percentage error (MAPE) of 2.06% and an R² value of 0.997 across the entire concentration range, demonstrating both high predictive accuracy and excellent model fit. ConclusionThis study demonstrates that the proposed method enables accurate and rapid determination of unknown sample concentrations. By combining GHz-EIS with BP neural network algorithms, efficient identification of cell concentrations is achieved, laying the foundation for the development of a convenient online cell analysis platform and showing significant application prospects. Compared to typical recognition approaches, the proposed method exhibits superior capabilities in recognizing cell suspension concentrations. Furthermore, this methodology not only accelerates research in cell biology and precision medicine but also paves the way for future EIS biosensors capable of intelligent, adaptive analysis in dynamic biological research.
8.Quantification of Atmospheric Total Reactive Nitrogen Oxides by Thermal Decomposition-Broadband Cavity Enhanced Absorption Spectroscopy
Dou SHAO ; Min QIN ; Wu FANG ; Bao-Bin HAN ; Ke TANG ; Jian-Ye XIE ; Xia-Dan ZHAO ; Zhi-Tang LIAO ; En-Bo REN
Chinese Journal of Analytical Chemistry 2025;53(3):387-396
Nitrogen oxides(NOx=NO+NO2)are important precursors of ozone(O3),and NOx and its oxides together constitute reactive nitrogen oxides(NOy)in the atmosphere.A comprehensive understanding of the total NOy level in the atmosphere is of great significance for a deeper understanding of the atmospheric nitrogen cycle and oxidation,as well as for formulating strategies for air pollution prevention and control.In this work,a thermal decomposition-broadband cavity enhanced absorption spectroscopy(TD-BBCEAS)technique for online measurement of total NOy in the atmosphere was developed.With this method,the NOy was efficiently converted into NO2,and the total NOy concentration in the atmosphere was indirectly obtained by measuring NO2.Focusing on the key factors affecting the measurement of total NOy,the influence of NO titration efficiency and other NOy component TD efficiency on measurement accuracy was emphasized.By changing the oxygen(O2)flow rate through the mercury lamp to alter the O3 concentration for titrating NO,the conversion efficiency of NO was evaluated.At O2 flow rate of 6 mL/min,the conversion efficiency of NO was greater than 99%.TD efficiency testing and analysis on NO2,peroxyacetyl nitrate(PAN),nitric acid(HNO3),and nitrous acid(HONO),which account for a large proportion of atmospheric NOy components,was carried out using 680℃as the optimal TD temperature for efficient conversion of NOy.With NO and HONO sample gases as typical verification gases,the conversion efficiency of NOy and the accuracy of NOy measurement by TD-BBCEAS system were verified by switching the on and off modes of mercury lamp and TD device.At integration time of 60 s,the detection limit of the system for NOy was 2.83×1010 molecules/cm3(60 s,2σ).A comparative measurement of actual atmospheric NOy was conducted between the TD-BBCEAS system and the NOy analyzer.The observation results showed a correlation coefficient(R2)of 0.98 and a slope of 0.93,further verifying the feasibility and accuracy of applying the TD-BBCEAS system to measurement of total NOy.
9.A Pneumatic Micro-valve with Sandwich Structure Based on Micro-electro-mechanical System
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(5):758-764
In this study,an ON/OFF type micro-valve with a sandwich(glass-silicon-glass)structure was designed and fabricated based on the micro-electro-mechanical system(MEMS)technique.The deformable membrane of this micro-valve was prepared on the silicon on insulator(SOI)substrate and sealed using Si-Si bonding and anodic bonding methods.The micro-valve had high-temperature stability and was suitable for integration with other gas chromatography components.The deformable membrane with a thickness of 10 μm was processed on the top silicon of the SOI substrate.The flow control of the micro-valve could be achieved by changing the driving pressure applied to the deformable membrane to deform it.Compared with polymer membranes,the deformable membrane prepared on the top layer silicon of SOI had better temperature stability and could be released using the deep reactive ion etching technique after silicon-silicon bonding,avoiding deformation during the preparation process.In addition,due to the small gap between the membrane and the inlet/outlet holes,the dead volume of the microvalve was very small.The test results indicated that the micro-valve achieved flow control and ON/OFF functions with good repeatability.
10.A Monolithic Integrated Gas Chromatography Chip with Gas Chromatographic Column and Helium Discharge Ionization Detector
Yu-Chen ZHU ; Shao-Jie MA ; Wen-Bo LI ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(7):1064-1071
A monolithic integrated gas chromatography chip,consisting of a micro gas chromatography column(μGCC)and a micro helium discharge ionization detector(μHDID)was proposed.The chip was fabricated using micro electromechanical system(MEMS)technique,and its sensitivity was improved from two aspects.On one hand,open tubular column was selected as the separation device,and the auxiliary helium channel width of μHDID was modulated based on the microchannel width of the μGCC to match the flow rates of μHDID and μGCC.On the other hand,the electrode structure inside the μHDID collection zone was optimized,a bias electrode group around the collection electrode was constructed,and the ion collection efficiency was improved.After coating HKUST-1 as the stationary phase,the monolithic integrated gas chromatography chip could achieve baseline separation and detection of light hydrocarbon gas mixture(methane,ethane,propane,andn-butane),with a detection limit for propane as low as 25 pg.The chip could carried out test under temperature-programmed conditions,with a resolution of 9.24 for ethane and propane.

Result Analysis
Print
Save
E-mail