1.Quantitative analysis of motion of cardiac substructures in deep inspiratory breath holding radiotherapy for left breast cancer
Zhao-hui TANG ; Zhe ZHANG ; Wei-bin MAO ; Bo HUANG ; Jun-feng AI ; Chao-fan ZHU ; Zhi-chao XIE ; Ya-jie LIU
Chinese Medical Equipment Journal 2025;46(3):54-58
Objective To quantify the volume and movement of cardiac substructures by using coronary computed tomography angiography(CCTA)to provide guidance for the design of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.Methods Totally 18 female patients who received conventional chest plain scan and CCTA were selected to simulate the design process of radiotherapy plan for left breast cancer patients with internal mammary lymph nodes.Retrospective reconstruction of CCTA data was performed for each patient,with 10 phase images(with an interval of 10%)within a R-R cardiac cycle(10%-100%)to simulate the true range of motion of the heart.The heart,left atrium(LA),left ventricle(LV),right atrium(RA),right ventricle(RV),left anterior descending artery(LAD),left circumflex coronary artery(LCX)and right coronary artery(RCA)were contoured at each phase.The distances from the centroid position to the average position of LAD,LCX and RCA were measured at each phase in the superior-inferior(SI),anterior-posterior(AP)and left-right(LR).The average volume and range of volume changes of LA,LV,RA,RV and heart were analyzed within a cardiac cycle.The expansion margins of planning organs at risk volume(PRV)were calculated.SPSS 19.0 software was used for statistical analysis.Results The following average absolute displacements were found in SI,AP and LR coordinates:(1.8±0.7)mm,(1.2±0.5)mm and(1.5±0.5)mm for LAD,respectively;(2.1±0.7)mm,(1.5±0.6)mm and(1.9±0.7)mm for LCX,respectively;(1.6±0.5)mm,(2.2±0.9)mm and(2.2±0.8)mm for RCA,respectively.The volume changes of LA,LV,RA,RV and heart within a cardiac cycle ranged from 34.3 to 63.9 cm3,122.1 to 154.3 cm3,29.3 to 53.6 cm3,57.2 to 94.3 cm3 and 480.1 to 515.4 cm3,respectively.The theoretical expansion margins of LAD,LCX and RCA in all the three directions were within 2 mm.Conclusion The ranges of movement and volume changes of cardiac substructure are quantitati-vely displayed,and references are provided for the planning of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.[Chinese Medical Equipment Journal,2025,46(3):54-58]
2.Observation on therapeutic effect of self-made auxiliary reduction device combined with sinus tarsi approach in treatment of Sanders type Ⅱ to Ⅳ calcaneal fractures
Yu ZHOU ; Da-gang TANG ; Wei PENG ; Xiao-bo HU ; Zhi CHEN ; Peng LONG ; Zhi-ping KUANG ; Chuan-zhi ZHANG
Journal of Regional Anatomy and Operative Surgery 2025;34(7):604-609
Objective To observe the efficacy of self-made auxiliary reduction device combined with sinus tarsi approach(STA)in the treatment of Sanders type Ⅱ to Ⅳ calcaneal fractures.Methods A total of 40 patients with Sanders type Ⅱ to Ⅳ calcaneal fractures admitted to our hospital from January to June 2023 were selected and divided into the control group and the observation group by the random number table method,with 20 cases in each group.Patients in the control group underwent surgical treatment with the heel extensile lateral approach(ELA),while patients in the observation group underwent surgical treatment with the auxiliary reduction device combined with STA.The surgical-related indicators,postoperative complications and ankle-foot anatomical indicators of patients in the two groups were compared.The recovery of limb function was evaluated by the American Orthopaedic Foot and Ankle Society(AOFAS)ankle-hindfoot scale and Maryland foot function score.Results There was no statistically significant difference in the operation time,postoperative incision drying time,or duration of postoperative pain between the two groups(P>0.05).The postoperative suture removal time of the patients in the observation group was shorter than that of the control group,and the difference was statistically significant(P<0.05).The incidence of skin edge necrosis of incision and the total incidence of complications of patients in the observation group were significantly lower than those in the control group(P<0.05).The B?hler angle and Gissane angle of patients in both groups increased after surgery compared with those before surgery(P<0.05);there was no statistically significant difference in the B?hler angle or Gissane angle after surgery of patients between the two groups(P>0.05).The AOFAS score1 week after surgery of the patients in the observation group was higher than that in the control group(P<0.05),while there were no statistically significant differences in the AOFAS scores or Maryland scores of patients at other time points between the two groups(P>0.05).Conclusion The use of the auxiliary reduction device in surgical treatment with STA for Sanders type Ⅱ to Ⅳ calcaneal fractures can effectively restore the function of the foot and ankle,with short postoperative suture removal time and low incidence of postoperative complications.
3.3D C-arm Combined With Orthopedic Robot-assisted Iliosacral Screw Fixation Through S3 Vertebra for Pelvic Fracture:Report of 4 Cases
Zongdong ZHU ; Bo TAN ; Zhi TANG ; Jiang HU ; Dan WEI ; Feng LIAO
Chinese Journal of Minimally Invasive Surgery 2025;25(10):636-640
Objective To verify the feasibility and safety of three-dimensional(3D)image acquisition by C-arm combined with orthopedic robot-assisted iliosacral screw fixation through S3 vertebra.Methods From July 2023 to June 2024,a total of 4 patients with closed pelvic fracture were surgically treated.Preoperative pelvic CT 3D reconstruction showed the presence of an ideal iliosacral screw bone channel through S3 vertebra which required screw fixation.There was no such channel through the S1 vertebra,or the stability of fixation through the S3 channel was better than that through the S1 channel.The 3D image acquisition by C-arm combined with orthopedic surgical robot was used to insert screws.Follow-ups were conducted for at least 6 months after surgery to assess fracture healing and limb function.Results All the 4 patients were successfully implanted with a S2 and a S3 iliosacral screw,and all the 8 screws did not penetrate the cortical bone.Three cases had excellent Majeed scores and 1 case had good scores at 3 months after surgery.Follow-ups were conducted for 18,12,7,and 6 months after surgery,respectively,and all fractures healed smoothly without any loosening or breakage of screws.Conclusion 3D image acquisition by C-arm combined with orthopedic robot-assisted iliosacral screw fixation through S3 vertebra is feasible,safe and effective.
4.Quantification of Atmospheric Total Reactive Nitrogen Oxides by Thermal Decomposition-Broadband Cavity Enhanced Absorption Spectroscopy
Dou SHAO ; Min QIN ; Wu FANG ; Bao-Bin HAN ; Ke TANG ; Jian-Ye XIE ; Xia-Dan ZHAO ; Zhi-Tang LIAO ; En-Bo REN
Chinese Journal of Analytical Chemistry 2025;53(3):387-396
Nitrogen oxides(NOx=NO+NO2)are important precursors of ozone(O3),and NOx and its oxides together constitute reactive nitrogen oxides(NOy)in the atmosphere.A comprehensive understanding of the total NOy level in the atmosphere is of great significance for a deeper understanding of the atmospheric nitrogen cycle and oxidation,as well as for formulating strategies for air pollution prevention and control.In this work,a thermal decomposition-broadband cavity enhanced absorption spectroscopy(TD-BBCEAS)technique for online measurement of total NOy in the atmosphere was developed.With this method,the NOy was efficiently converted into NO2,and the total NOy concentration in the atmosphere was indirectly obtained by measuring NO2.Focusing on the key factors affecting the measurement of total NOy,the influence of NO titration efficiency and other NOy component TD efficiency on measurement accuracy was emphasized.By changing the oxygen(O2)flow rate through the mercury lamp to alter the O3 concentration for titrating NO,the conversion efficiency of NO was evaluated.At O2 flow rate of 6 mL/min,the conversion efficiency of NO was greater than 99%.TD efficiency testing and analysis on NO2,peroxyacetyl nitrate(PAN),nitric acid(HNO3),and nitrous acid(HONO),which account for a large proportion of atmospheric NOy components,was carried out using 680℃as the optimal TD temperature for efficient conversion of NOy.With NO and HONO sample gases as typical verification gases,the conversion efficiency of NOy and the accuracy of NOy measurement by TD-BBCEAS system were verified by switching the on and off modes of mercury lamp and TD device.At integration time of 60 s,the detection limit of the system for NOy was 2.83×1010 molecules/cm3(60 s,2σ).A comparative measurement of actual atmospheric NOy was conducted between the TD-BBCEAS system and the NOy analyzer.The observation results showed a correlation coefficient(R2)of 0.98 and a slope of 0.93,further verifying the feasibility and accuracy of applying the TD-BBCEAS system to measurement of total NOy.
5.Research Progress on Electrochemical Sensing Techniques for Detection of Telomerase Activity
Hai-Tang YANG ; Peng-Hua SHU ; Wen-Lin LIU ; Wen-Bo MA ; Zi-Jun YANG ; Zhi-Feng DENG ; Xin-Yun ZHANG ; Wei WEI
Chinese Journal of Analytical Chemistry 2025;53(6):864-874
The telomere structure in the cell nucleus is crucial for maintaining the stability and functions of chromosomes.Telomerase is a ribonucleoprotein reverse transcriptase,which catalyzes the elongation of telomeres using its own RNA as a template,thereby counteracting the shortening of telomeres caused by chromosome replication and cell division.Due to its overexpression in over 85%of malignant tumor cells,telomerase has emerged as a highly promising biomarker and a novel target for cancer therapy.In recent years,given the importance of precise quantification of telomerase activity in guiding medical diagnosis and treatment strategies,researchers have developed various high-performance telomerase detection techniques.Among these,electrochemical biosensing technique has cause much attention due to its high sensitivity,operational convenience,rapid response,and ease of miniaturization.This paper focused on the latest advances in electrochemical sensing technique for detection of telomerase activity,aiming to provide inspiration for designing novel telomerase activity detection strategies by elucidating three unique properties of telomerase primer extension products.
6.Tailoring a traditional Chinese medicine prescription for complex diseases: A novel multi-targets-directed gradient weighting strategy.
Zhe YU ; Teng LI ; Zhi ZHENG ; Xiya YANG ; Xin GUO ; Xindi ZHANG ; Haoying JIANG ; Lin ZHU ; Bo YANG ; Yang WANG ; Jiekun LUO ; Xueping YANG ; Tao TANG ; En HU
Journal of Pharmaceutical Analysis 2025;15(4):101199-101199
Traditional Chinese medicine (TCM) exerts integrative effects on complex diseases owing to the characteristics of multiple components with multiple targets. However, the syndrome-based system of diagnosis and treatment in TCM can easily lead to bias because of varying medication preferences among physicians, which has been a major challenge in the global acceptance and application of TCM. Therefore, a standardized TCM prescription system needs to be explored to promote its clinical application. In this study, we first developed a gradient weighted disease-target-herbal ingredient-herb network to aid TCM formulation. We tested its efficacy against intracerebral hemorrhage (ICH). First, the top 100 ICH targets in the GeneCards database were screened according to their relevance scores. Then, SymMap and Traditional Chinese Medicine Systems Pharmacology (TCMSP) databases were applied to find out the target-related ingredients and ingredient-containing herbs, respectively. The relevance of the resulting ingredients and herbs to ICH was determined by adding the relevance scores of the corresponding targets. The top five ICH therapeutic herbs were combined to form a tailored TCM prescriptions. The absorbed components in the serum were detected. In a mouse model of ICH, the new prescription exerted multifaceted effects, including improved neurological function, as well as attenuated neuronal damage, cell apoptosis, vascular leakage, and neuroinflammation. These effects matched well with the core pathological changes in ICH. The multi-targets-directed gradient-weighting strategy presents a promising avenue for tailoring precise, multipronged, unbiased, and standardized TCM prescriptions for complex diseases. This study provides a paradigm for advanced achievements-driven modern innovation in TCM concepts.
7.Tailoring a traditional Chinese medicine prescription for complex diseases:A novel multi-targets-directed gradient weighting strategy
Zhe YU ; Teng LI ; Zhi ZHENG ; Xiya YANG ; Xin GUO ; Xindi ZHANG ; Haoying JIANG ; Lin ZHU ; Bo YANG ; Yang WANG ; Jiekun LUO ; Xueping YANG ; Tao TANG ; En HU
Journal of Pharmaceutical Analysis 2025;15(4):804-816
Traditional Chinese medicine(TCM)exerts integrative effects on complex diseases owing to the char-acteristics of multiple components with multiple targets.However,the syndrome-based system of diagnosis and treatment in TCM can easily lead to bias because of varying medication preferences among physicians,which has been a major challenge in the global acceptance and application of TCM.Therefore,a standardized TCM prescription system needs to be explored to promote its clinical application.In this study,we first developed a gradient weighted disease-target-herbal ingredient-herb network to aid TCM formulation.We tested its efficacy against intracerebral hemorrhage(ICH).First,the top 100 ICH targets in the GeneCards database were screened according to their relevance scores.Then,SymMap and Traditional Chinese Medicine Systems Pharmacology(TCMSP)databases were applied to find out the target-related ingredients and ingredient-containing herbs,respectively.The relevance of the resulting ingredients and herbs to ICH was determined by adding the relevance scores of the corresponding targets.The top five ICH therapeutic herbs were combined to form a tailored TCM prescriptions.The absorbed components in the serum were detected.In a mouse model of ICH,the new prescription exerted multifaceted effects,including improved neurological function,as well as attenuated neuronal damage,cell apoptosis,vascular leakage,and neuroinflammation.These effects matched well with the core pathological changes in ICH.The multi-targets-directed gradient-weighting strategy presents a promising avenue for tailoring precise,multipronged,unbiased,and standardized TCM prescriptions for complex diseases.This study provides a paradigm for advanced achievements-driven modern innovation in TCM concepts.
8.Quantitative analysis of motion of cardiac substructures in deep inspiratory breath holding radiotherapy for left breast cancer
Zhao-hui TANG ; Zhe ZHANG ; Wei-bin MAO ; Bo HUANG ; Jun-feng AI ; Chao-fan ZHU ; Zhi-chao XIE ; Ya-jie LIU
Chinese Medical Equipment Journal 2025;46(3):54-58
Objective To quantify the volume and movement of cardiac substructures by using coronary computed tomography angiography(CCTA)to provide guidance for the design of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.Methods Totally 18 female patients who received conventional chest plain scan and CCTA were selected to simulate the design process of radiotherapy plan for left breast cancer patients with internal mammary lymph nodes.Retrospective reconstruction of CCTA data was performed for each patient,with 10 phase images(with an interval of 10%)within a R-R cardiac cycle(10%-100%)to simulate the true range of motion of the heart.The heart,left atrium(LA),left ventricle(LV),right atrium(RA),right ventricle(RV),left anterior descending artery(LAD),left circumflex coronary artery(LCX)and right coronary artery(RCA)were contoured at each phase.The distances from the centroid position to the average position of LAD,LCX and RCA were measured at each phase in the superior-inferior(SI),anterior-posterior(AP)and left-right(LR).The average volume and range of volume changes of LA,LV,RA,RV and heart were analyzed within a cardiac cycle.The expansion margins of planning organs at risk volume(PRV)were calculated.SPSS 19.0 software was used for statistical analysis.Results The following average absolute displacements were found in SI,AP and LR coordinates:(1.8±0.7)mm,(1.2±0.5)mm and(1.5±0.5)mm for LAD,respectively;(2.1±0.7)mm,(1.5±0.6)mm and(1.9±0.7)mm for LCX,respectively;(1.6±0.5)mm,(2.2±0.9)mm and(2.2±0.8)mm for RCA,respectively.The volume changes of LA,LV,RA,RV and heart within a cardiac cycle ranged from 34.3 to 63.9 cm3,122.1 to 154.3 cm3,29.3 to 53.6 cm3,57.2 to 94.3 cm3 and 480.1 to 515.4 cm3,respectively.The theoretical expansion margins of LAD,LCX and RCA in all the three directions were within 2 mm.Conclusion The ranges of movement and volume changes of cardiac substructure are quantitati-vely displayed,and references are provided for the planning of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.[Chinese Medical Equipment Journal,2025,46(3):54-58]
9.Observation on therapeutic effect of self-made auxiliary reduction device combined with sinus tarsi approach in treatment of Sanders type Ⅱ to Ⅳ calcaneal fractures
Yu ZHOU ; Da-gang TANG ; Wei PENG ; Xiao-bo HU ; Zhi CHEN ; Peng LONG ; Zhi-ping KUANG ; Chuan-zhi ZHANG
Journal of Regional Anatomy and Operative Surgery 2025;34(7):604-609
Objective To observe the efficacy of self-made auxiliary reduction device combined with sinus tarsi approach(STA)in the treatment of Sanders type Ⅱ to Ⅳ calcaneal fractures.Methods A total of 40 patients with Sanders type Ⅱ to Ⅳ calcaneal fractures admitted to our hospital from January to June 2023 were selected and divided into the control group and the observation group by the random number table method,with 20 cases in each group.Patients in the control group underwent surgical treatment with the heel extensile lateral approach(ELA),while patients in the observation group underwent surgical treatment with the auxiliary reduction device combined with STA.The surgical-related indicators,postoperative complications and ankle-foot anatomical indicators of patients in the two groups were compared.The recovery of limb function was evaluated by the American Orthopaedic Foot and Ankle Society(AOFAS)ankle-hindfoot scale and Maryland foot function score.Results There was no statistically significant difference in the operation time,postoperative incision drying time,or duration of postoperative pain between the two groups(P>0.05).The postoperative suture removal time of the patients in the observation group was shorter than that of the control group,and the difference was statistically significant(P<0.05).The incidence of skin edge necrosis of incision and the total incidence of complications of patients in the observation group were significantly lower than those in the control group(P<0.05).The B?hler angle and Gissane angle of patients in both groups increased after surgery compared with those before surgery(P<0.05);there was no statistically significant difference in the B?hler angle or Gissane angle after surgery of patients between the two groups(P>0.05).The AOFAS score1 week after surgery of the patients in the observation group was higher than that in the control group(P<0.05),while there were no statistically significant differences in the AOFAS scores or Maryland scores of patients at other time points between the two groups(P>0.05).Conclusion The use of the auxiliary reduction device in surgical treatment with STA for Sanders type Ⅱ to Ⅳ calcaneal fractures can effectively restore the function of the foot and ankle,with short postoperative suture removal time and low incidence of postoperative complications.
10.3D C-arm Combined With Orthopedic Robot-assisted Iliosacral Screw Fixation Through S3 Vertebra for Pelvic Fracture:Report of 4 Cases
Zongdong ZHU ; Bo TAN ; Zhi TANG ; Jiang HU ; Dan WEI ; Feng LIAO
Chinese Journal of Minimally Invasive Surgery 2025;25(10):636-640
Objective To verify the feasibility and safety of three-dimensional(3D)image acquisition by C-arm combined with orthopedic robot-assisted iliosacral screw fixation through S3 vertebra.Methods From July 2023 to June 2024,a total of 4 patients with closed pelvic fracture were surgically treated.Preoperative pelvic CT 3D reconstruction showed the presence of an ideal iliosacral screw bone channel through S3 vertebra which required screw fixation.There was no such channel through the S1 vertebra,or the stability of fixation through the S3 channel was better than that through the S1 channel.The 3D image acquisition by C-arm combined with orthopedic surgical robot was used to insert screws.Follow-ups were conducted for at least 6 months after surgery to assess fracture healing and limb function.Results All the 4 patients were successfully implanted with a S2 and a S3 iliosacral screw,and all the 8 screws did not penetrate the cortical bone.Three cases had excellent Majeed scores and 1 case had good scores at 3 months after surgery.Follow-ups were conducted for 18,12,7,and 6 months after surgery,respectively,and all fractures healed smoothly without any loosening or breakage of screws.Conclusion 3D image acquisition by C-arm combined with orthopedic robot-assisted iliosacral screw fixation through S3 vertebra is feasible,safe and effective.

Result Analysis
Print
Save
E-mail