1.Advancements in Gas-releasing Micro/Nanoplatforms for Overcoming MDR Bacterial Infections in Diabetic Wounds
Ruo-Can LIU ; Yu-Qian WANG ; Shuai ZHANG ; Shao-Zhi ZUO ; Yun-Di WU ; Xi-Long WU
Progress in Biochemistry and Biophysics 2026;53(5):1356-1375
Chronic diabetic wounds, severely complicated by multidrug-resistant (MDR) bacterial infections, represent a profound and escalating global health crisis. The intrinsically hostile microenvironment of diabetic wounds, characterized by localized hypoxia, persistent oxidative stress, and poor vascularization, creates an ideal niche for opportunistic pathogens such as Staphylococcus aureus and Pseudomonas aeruginosa. These bacteria readily construct dense extracellular polymeric substance (EPS) biofilms, which not only physically shield the microbes from host immune responses but also actively trap the wound in a state of chronic, unresolved inflammation. Consequently, conventional systemic and topical antibiotic therapies are becoming increasingly futile, as poor perfusion at the wound site restricts drug bioavailability, while the rapid genetic evolution of bacteria and the impenetrable nature of biofilms lead to catastrophic treatment failures, often culminating in severe tissue necrosis and lower-extremity amputations. To circumvent the limitations of traditional antimicrobials, therapeutic gas delivery has emerged as a highly promising, paradigm-shifting strategy. Gaseous signaling molecules, particularly nitric oxide (NO), carbon monoxide (CO), hydrogen sulfide (H2S), and hydrogen (H2), possess unique physicochemical properties that allow them to seamlessly penetrate dense biofilm matrices and cellular membranes. Once inside, these gases operate via multi-targeted mechanisms that are incredibly difficult for bacteria to develop resistance against; for instance, NO induces severe lipid peroxidation and DNA cleavage in bacteria, CO downregulates pro-inflammatory cytokines, H2S significantly accelerates endothelial cell migration for neovascularization, and H2 acts as a powerful selective antioxidant to neutralize tissue-damaging reactive oxygen species (ROS). Together, these therapeutic gases not only exert broad-spectrum bactericidal effects but also actively reprogram the wound bed by promoting the critical M1-to-M2 macrophage polarization and stimulating angiogenesis. Despite their immense biological potential, the direct clinical translation of gas therapies is severely hindered by inherent physicochemical drawbacks, including extreme volatility, short physiological half-lives, poor aqueous solubility, and the high risk of off-target systemic toxicity, if applied indiscriminately. To conquer these immense pharmacokinetic barriers, cutting-edge advancements in materials science have driven the development of gas-releasing micro- and nanoplatforms. Utilizing sophisticated carriers such as metal-organic frameworks (MOFs), mesoporous silica, polymeric nanoparticles, liposomes, and injectable hydrogels, researchers can now encapsulate gas-donor molecules to achieve sustained, localized delivery. More importantly, these advanced nanoplatforms are ingeniously engineered to be stimuli-responsive. By exploiting the pathological hallmarks of the diabetic wound environment, such as elevated glucose concentrations, acidic pH, and overexpressed ROS, or by utilizing external triggers like near-infrared (NIR) light irradiation and ultrasound, these intelligent platforms ensure on-demand, precise spatio-temporal gas release. This often allows for powerful synergistic combinations, such as photothermal or photodynamic therapy coupled with gas release, thereby obliterating biofilms while sparing healthy tissue. While the therapeutic outcomes of these smart delivery systems in eradicating MDR infections and accelerating tissue repair are unprecedented, several critical challenges remain before widespread clinical adoption, as long-term biosafety profiles of the carrier nanomaterials, complexities in large-scale good manufacturing practice (GMP) production, and stringent regulatory hurdles must be rigorously addressed. Looking forward, the next frontier lies in the realm of precision medicine and theranostics, where future research must focus on the seamless integration of these gas-releasing platforms with flexible, wearable biosensors capable of continuously monitoring wound biomarkers (e.g., pH, temperature, uric acid) in real-time. Coupled with artificial intelligence algorithms to govern automated, closed-loop adaptive dosing, these next-generation smart dressings hold the ultimate potential to comprehensively transform the clinical management of complex, infected diabetic wounds.
2.Advancements in Gas-releasing Micro/Nanoplatforms for Overcoming MDR Bacterial Infections in Diabetic Wounds
Ruo-Can LIU ; Yu-Qian WANG ; Shuai ZHANG ; Shao-Zhi ZUO ; Yun-Di WU ; Xi-Long WU
Progress in Biochemistry and Biophysics 2026;53(5):1356-1375
Chronic diabetic wounds, severely complicated by multidrug-resistant (MDR) bacterial infections, represent a profound and escalating global health crisis. The intrinsically hostile microenvironment of diabetic wounds, characterized by localized hypoxia, persistent oxidative stress, and poor vascularization, creates an ideal niche for opportunistic pathogens such as Staphylococcus aureus and Pseudomonas aeruginosa. These bacteria readily construct dense extracellular polymeric substance (EPS) biofilms, which not only physically shield the microbes from host immune responses but also actively trap the wound in a state of chronic, unresolved inflammation. Consequently, conventional systemic and topical antibiotic therapies are becoming increasingly futile, as poor perfusion at the wound site restricts drug bioavailability, while the rapid genetic evolution of bacteria and the impenetrable nature of biofilms lead to catastrophic treatment failures, often culminating in severe tissue necrosis and lower-extremity amputations. To circumvent the limitations of traditional antimicrobials, therapeutic gas delivery has emerged as a highly promising, paradigm-shifting strategy. Gaseous signaling molecules, particularly nitric oxide (NO), carbon monoxide (CO), hydrogen sulfide (H2S), and hydrogen (H2), possess unique physicochemical properties that allow them to seamlessly penetrate dense biofilm matrices and cellular membranes. Once inside, these gases operate via multi-targeted mechanisms that are incredibly difficult for bacteria to develop resistance against; for instance, NO induces severe lipid peroxidation and DNA cleavage in bacteria, CO downregulates pro-inflammatory cytokines, H2S significantly accelerates endothelial cell migration for neovascularization, and H2 acts as a powerful selective antioxidant to neutralize tissue-damaging reactive oxygen species (ROS). Together, these therapeutic gases not only exert broad-spectrum bactericidal effects but also actively reprogram the wound bed by promoting the critical M1-to-M2 macrophage polarization and stimulating angiogenesis. Despite their immense biological potential, the direct clinical translation of gas therapies is severely hindered by inherent physicochemical drawbacks, including extreme volatility, short physiological half-lives, poor aqueous solubility, and the high risk of off-target systemic toxicity, if applied indiscriminately. To conquer these immense pharmacokinetic barriers, cutting-edge advancements in materials science have driven the development of gas-releasing micro- and nanoplatforms. Utilizing sophisticated carriers such as metal-organic frameworks (MOFs), mesoporous silica, polymeric nanoparticles, liposomes, and injectable hydrogels, researchers can now encapsulate gas-donor molecules to achieve sustained, localized delivery. More importantly, these advanced nanoplatforms are ingeniously engineered to be stimuli-responsive. By exploiting the pathological hallmarks of the diabetic wound environment, such as elevated glucose concentrations, acidic pH, and overexpressed ROS, or by utilizing external triggers like near-infrared (NIR) light irradiation and ultrasound, these intelligent platforms ensure on-demand, precise spatio-temporal gas release. This often allows for powerful synergistic combinations, such as photothermal or photodynamic therapy coupled with gas release, thereby obliterating biofilms while sparing healthy tissue. While the therapeutic outcomes of these smart delivery systems in eradicating MDR infections and accelerating tissue repair are unprecedented, several critical challenges remain before widespread clinical adoption, as long-term biosafety profiles of the carrier nanomaterials, complexities in large-scale good manufacturing practice (GMP) production, and stringent regulatory hurdles must be rigorously addressed. Looking forward, the next frontier lies in the realm of precision medicine and theranostics, where future research must focus on the seamless integration of these gas-releasing platforms with flexible, wearable biosensors capable of continuously monitoring wound biomarkers (e.g., pH, temperature, uric acid) in real-time. Coupled with artificial intelligence algorithms to govern automated, closed-loop adaptive dosing, these next-generation smart dressings hold the ultimate potential to comprehensively transform the clinical management of complex, infected diabetic wounds.
3.Guidelines for the perioperative diagnosis and treatment of oncogene-driven non-small cell lung cancer (2026)
Weidong WANG ; Yongbin LIN ; Hui TIAN ; Gaofeng LI ; Shun XU ; Yongde LIAO ; Haitao MA ; Junfeng LIU ; Chundong GU ; Xiaolong YAN ; Shumin WANG ; Daqiang SUN ; Jianyang LIU ; Tao XUE ; Shaohua MA ; Zhigang LI ; Shuanghu YUAN ; Gen LIN ; Ling CAI ; Jianping ZHOU ; Wenzhao ZHONG ; Naixin LIANG ; Yi HAN ; Junfeng WANG ; Weidong ZHANG ; Xin WANG ; Lianjuan CHEN ; Lunxu LIU ; Xiuyi ZHI ; Lanjun ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(09):1337-1353
Lung cancer constitutes the most prevalent and lethal malignant tumor in China. Approximately 85% of lung cancer diagnoses correspond to the non-small cell histological subtype [non-small cell lung cancer (NSCLC)]. Despite surgery being the mainstay for early-stage disease, postoperative recurrence remains high and adjuvant chemotherapy offers limited benefit. In recent years, targeted therapy has demonstrated substantial advantages in driver mutation-positive NSCLC. To this end, the Lung Cancer Medical Education Committee of the Chinese Medical Education Association developed guidelines based on a systematic review of evidence through November 2025, using the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach and a modified Delphi method. Focusing on epidermal growth factor receptor (EGFR) and anaplastic lymphoma kinase (ALK), and addressing ROS proto-oncogene 1 (ROS1), B-Raf proto-oncogene serine/threonine kinase (BRAF) V600E mutation, and mesenchymal-epithelial transition factor (MET) exon 14 (METex14) skipping, the guideline covers molecular testing, neoadjuvant/adjuvant therapy, perioperative strategies, minimal residual disease monitoring, and postoperative surveillance. It defines testing requirements, specifies stage-directed and subtype-specific treatments, and standardizes minimal residual disease monitoring. These recommendations emphasize precision and feasibility to improve survival and quality of life.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Clinical application of single-balloon and double-balloon enteroscopy in pediatric small bowel diseases: a retrospective study of 576 cases.
Can-Lin LI ; Jie-Yu YOU ; Yan-Hong LUO ; Hong-Juan OU-YANG ; Li LIU ; Wen-Ting ZHANG ; Jia-Qi DUAN ; Na JIANG ; Mei-Zheng ZHAN ; Chen-Xi LIU ; Juan ZHOU ; Ling-Zhi YUAN ; Hong-Mei ZHAO
Chinese Journal of Contemporary Pediatrics 2025;27(7):822-828
OBJECTIVES:
To evaluate the effectiveness of single-balloon and double-balloon enteroscopy in diagnosing pediatric small bowel diseases and assess the diagnostic efficacy of computed tomography enterography (CTE) for small bowel diseases using enteroscopy as the reference standard.
METHODS:
Clinical data from 576 children who underwent enteroscopy at Hunan Children's Hospital between January 2017 and December 2023 were retrospectively collected. The children were categorized based on enteroscopy type into the single-balloon enteroscopy (SBE) group (n=457) and double-balloon enteroscopy (DBE) group (n=119), and the clinical data were compared between the two groups. The sensitivity and specificity of CTE for diagnosing small bowel diseases were evaluated using enteroscopy results as the standard.
RESULTS:
Among the 576 children, small bowel lesions were detected by enteroscopy in 274 children (47.6%).There was no significant difference in lesion detection rates or complication rates between the SBE and DBE groups (P>0.05), but the DBE group had deeper insertion, longer procedure time, and higher complete small bowel examination rate (P<0.05). The complication rate during enteroscopy was 4.3% (25/576), with 18 cases (3.1%) of mild complications and 7 cases (1.2%) of severe complications, which improved with symptomatic treatment, surgical, or endoscopic intervention. Among the 412 children who underwent CTE, the sensitivity and specificity for diagnosing small bowel diseases were 44.4% and 71.3%, respectively.
CONCLUSIONS
SBE and DBE have similar diagnostic efficacy for pediatric small bowel diseases, but DBE is preferred for suspected deep small bowel lesions and comprehensive small bowel examination. Enteroscopy in children demonstrates relatively good overall safety. CTE demonstrates relatively low sensitivity but comparatively high specificity for diagnosing small bowel diseases.
Retrospective Studies
;
Treatment Outcome
;
Double-Balloon Enteroscopy/statistics & numerical data*
;
Single-Balloon Enteroscopy/statistics & numerical data*
;
Humans
;
Male
;
Female
;
Child
;
Operative Time
;
Tomography, X-Ray Computed/statistics & numerical data*
;
Sensitivity and Specificity
;
Intestine, Small/surgery*
;
Intestinal Diseases/surgery*
8.Pharmacological Mechanism of Chinese Medicine in Systemic Lupus Erythematosus: A Narrative Review.
Bo-Yu ZHU ; Zhi-Chao LIU ; Zhen-Xi ZHAO ; Hui-Ping HUANG ; Na ZHANG ; Jia XIA ; Wei-Wei CHEN
Chinese journal of integrative medicine 2025;31(2):157-169
Systemic lupus erythematosus (SLE) is a chronic autoimmune disorder affecting multiple systems, characterized by the development of harmful autoantibodies and immune complexes that lead to damage in organs and tissues. Chinese medicine (CM) plays a role in mitigating complications, enhancing treatment effectiveness, and reducing toxicity of concurrent medications, and ensuring a safe pregnancy. However, CM mainly solves the disease comprehensively through multi-target and multi-channel regulation process, therefore, its treatment mechanism is often complicated, involving many molecular links. This review introduces the research progress of pathogenesis of SLE from the aspects of genetics, epigenetics, innate immunity and acquired immunity, and then discusses the molecular mechanism and target of single Chinese herbal medicine and prescription that are commonly used and effective in clinic to treat SLE.
Lupus Erythematosus, Systemic/immunology*
;
Humans
;
Medicine, Chinese Traditional
;
Drugs, Chinese Herbal/pharmacology*
;
Animals
9.Mechanosensory activation of Piezo1 via cupping therapy: Harnessing neural networks to modulate AMPK pathway for metabolic restoration in a mouse model of psoriasis.
Ruo-Fan XI ; Xin LIU ; Yi WANG ; Han-Zhi LU ; Shao-Jie YUAN ; Dong-Jie GUO ; Jian-Yong ZHU ; Fu-Lun LI ; Yan-Juan DUAN
Journal of Integrative Medicine 2025;23(6):721-732
OBJECTIVE:
Psoriasis, a common chronic inflammatory skin condition with genetic underpinnings, is traditionally managed with cupping therapy. Although used historically, the precise mechanical effects and therapeutic mechanisms of cupping in psoriasis remain largely unexamined. This study aimed to evaluate cupping therapy's efficacy for psoriasis and investigate its role in modulating inflammatory responses and cellular metabolism.
METHODS:
Psoriasis was induced in mice using topical imiquimod (IMQ). The effects of cupping on psoriatic lesions were assessed using the Psoriasis Area and Severity Index score, histology, immunohistochemistry, and immunofluorescence staining. polymerase chain reaction sequencing (RNA-seq) and Western blotting were conducted to examine changes in mRNA expression and the AMP-activated protein kinase (AMPK) signaling pathway.
RESULTS:
Cupping therapy significantly reduced inflammation, epidermal thickness, and inflammatory cell infiltration in mice with IMQ-induced psoriasis. Immunohistochemistry and immunofluorescence showed lower expression of inflammatory markers and a shift in T-cell populations. RNA-seq and Western blotting indicated that cupping upregulated Piezo1 and activated the AMPK pathway, improving energy metabolism in psoriatic skin.
CONCLUSION
Cupping therapy reduces epidermal hyperproliferation and inflammation in psoriasis, rebalancing the local immune microenvironment. Mechanistically, cupping promotes calcium influx via Piezo1, activates AMPK signaling, and supports metabolic homeostasis, suggesting therapeutic potential for psoriasis. Please cite this article as: Xi RF, Liu X, Wang Y, Lu HZ, Yuan SJ, Guo DJ, Zhu JY, Li FL, Duan YJ. Mechanosensory activation of Piezo1 via cupping therapy: Harnessing neural networks to modulate AMPK pathway for metabolic restoration in a mouse model of psoriasis. J Integr Med. 2025; 23(6):721-732.
Animals
;
Psoriasis/chemically induced*
;
Mice
;
AMP-Activated Protein Kinases/metabolism*
;
Disease Models, Animal
;
Cupping Therapy/methods*
;
Signal Transduction
;
Imiquimod
;
Ion Channels/genetics*
;
Male
;
Mechanotransduction, Cellular
10.Separate and Combained Associations of PM 2.5 Exposure and Smoking with Dementia and Cognitive Impairment.
Lu CUI ; Zhi Hui WANG ; Yu Hong LIU ; Lin Lin MA ; Shi Ge QI ; Ran AN ; Xi CHEN ; Hao Yan GUO ; Yu Xiang YAN
Biomedical and Environmental Sciences 2025;38(2):194-205
OBJECTIVE:
The results of limited studies on the relationship between environmental pollution and dementia have been contradictory. We analyzed the combined effects of PM 2.5 and smoking on the prevalence of dementia and cognitive impairment in an elderly community-dwelling Chinese population.
METHODS:
We assessed 24,117 individuals along with the annual average PM 2.5 concentrations from 2012 to 2016. Dementia was confirmed in the baseline survey at a qualified clinical facility, and newly suspected dementia was assessed in 2017, after excluding cases of suspected dementia in 2015. National census data were used to weight the sample data to reflect the entire population in China, with multiple logistic regression performed to analyze the combined effects of PM 2.5 and smoking frequency on dementia and cognitive impairment.
RESULTS:
Individuals exposed to the highest PM 2.5 concentration and smoked daily were at higher risk of dementia than those in the lowest PM 2.5 concentration group ( OR, 1.603; 95% CI [1.626-1.635], P < 0.0001) and in the nonsmoking group ( OR, 1.248; 95% CI [1.244-1.252]; P < 0.0001). Moderate PM 2.5 exposure and occasional smoking together increased the short-term risk of cognitive impairment. High-level PM 2.5 exposure and smoking were associated with an increased risk of dementia, so more efforts are needed to reduce this risk through environmental protection and antismoking campaigns.
CONCLUSION
High-level PM 2.5 exposure and smoking were associated with an increased risk of dementia. Lowering the ambient PM 2.5, and smoking cessation are recommended to promote health.
Humans
;
Dementia/etiology*
;
Male
;
Aged
;
Female
;
Cognitive Dysfunction/etiology*
;
China/epidemiology*
;
Particulate Matter/analysis*
;
Smoking/epidemiology*
;
Air Pollutants/analysis*
;
Aged, 80 and over
;
Environmental Exposure/adverse effects*
;
Prevalence
;
Middle Aged

Result Analysis
Print
Save
E-mail