1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Study on the 90-day Feeding Experimental Background Data of SD Rats for Drug Safety Evaluation
Chao QIN ; Shuangxing LI ; Tingting ZHAO ; Chenchen JIANG ; Jing ZHAO ; Yanwei YANG ; Zhi LIN ; Sanlong WANG ; Hairuo WEN
Laboratory Animal and Comparative Medicine 2025;45(4):439-448
ObjectiveTo establish background data for a 90-day feeding trial of SD rats to ensure the reliability of research data. MethodsBackground data from six independent 90-day feeding trials of SD rats conducted by the National Center for Safety Evaluation of Drugs from 2020 to 2023 were summarized. These studies involved a blank control group of 120 SPF-grade 4-week-old SD rats, with an equal number of males and females, which were only given standard full-nutrient pelleted rat feed. After the quarantine period, the animals were observed for an additional 90 days, followed by intraperitoneal injection of Zoletil (50 mg/mL) for anesthesia, blood sampling, euthanasia, and necropsy. By analyzing the data from the blank control group, a relevant background database for SD rats was established. ResultsBoth male and female rats exhibited steady weight gain, with a more pronounced increase in male rats. Within 90 days, the average body weight of male and female rats increased to over 500 g and 300 g, respectively. Three weeks later, the average daily food intake of male rats stabilized at approximately 25~28 g per rat, while that of female rats remained stable at approximately 16~19 g per rat. The food utilization rate of all animals gradually decreased from the first week of the experiment. In the white blood cell (WBC) differential count results, significant differences were observed in the counts of WBCs, neutrophils (Neut), lymphocytes (Lymph), and monocytes (Mono) between males and females (P<0.001). However, there were no significant differences in the percentages of neutrophil (%Neut), lymphocyte (%Lymph), and monocyte (%Mono) between the sexes (P>0.05). The average red blood cell count (RBC), hemoglobin concentration (HGB), hematocrit (HCT), platelet count (PLT), prothrombin time (PT), and activated partial thromboplastin time (APTT) were higher in male animals than in female animals (P<0.05). The average values of alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), creatine phosphokinase (CK), lactate dehydrogenase (LDH), glucose (GLU), and triglyceride (TG) in male rats were higher than those in female rats (P<0.05). The urinary pH range for male animals was 5.0 to 8.5, while for female animals it was 6.5 to 9.0. The majority of male animals had a urinary specific gravity lower than 1.020, and the majority of female animals had a urinary specific gravity lower than 1.015. The weights of various organs (excluding the adrenal glands and reproductive organs) in male animals were heavier than those in female animals (P<0.001), while the organ/body weight ratios (excluding the kidneys and reproductive organs) of female animals were higher than those of male animals (P<0.001). ConclusionThis study summarizes the background reference ranges for body weight, food intake, hematology, and serum biochemistry indicators in SPF-grade SD rats in the untreated control group from six 90-day feeding trials conducted by the National Center for Safety Evaluation of Drugs. It provides important reference data for related research. By summarizing the background and spontaneous histopathological changes in rats, this study aids in the standardization and normalization of subsequent research, as well as in the evaluation and analysis of abnormal results.
7.The impact of continuous nebulization therapy on pulmonary function and related complications after lung transplantation
Pengfei LI ; Zhi QIN ; Zhidan DING ; Kai ZHAO ; Yuebin WANG ; Fengke LI ; Jinrui LI ; Gaofeng ZHAO
Organ Transplantation 2025;16(6):914-920
Objective To investigate the impact of continuous nebulization therapy after lung transplantation on pulmonary function and related complications in lung transplant recipients. Methods A retrospective analysis was conducted on the general data of 71 recipients who underwent allogeneic lung transplantation at the Department of Thoracic Surgery, the First Affiliated Hospital of Zhengzhou University, from June 2013 to December 2024. Recipients were divided into observation group (those who continued nebulization therapy for more than 3 months after discharge) and control group (those who discontinued nebulization therapy on their own). The main observation indicators were pulmonary function indicators at 6 months after surgery, including forced expiratory volume in the first second as a percentage of predicted value (FEV1% pred), forced vital capacity as a percentage of predicted value (FVC% pred), ratio of forced expiratory volume in the first second to forced vital capacity as a percentage of predicted value (FEV1/FVC% pred), forced expiratory flow at 25%, 50% and 75% of forced vital capacity as a percentage of predicted value, and the percentage of predicted value of corrected carbon monoxide diffusion capacity measured by single-breath method, as well as the ratio of corrected carbon monoxide diffusion capacity to alveolar volume as a percentage of predicted value. Additionally, the annual incidence of postoperative pulmonary infections, survival rate and the rate of no severe airway complications were analyzed. Results At 6 months after lung transplantation, the FEV1% pred and FVC% pred of the observation group were better than those of the control group [FEV1% pred was 76% (60%, 91%) vs. 67% (62%, 78%), FVC% pred was (75 ± 13)% vs. (69 ± 11)%, both P<0.05]. The observation group had a lower annual incidence of pulmonary infections compared to the control group (P = 0.023), with a risk of 0.485 times that of the control group. There were no statistically significant differences between the two groups in median survival time and the rate of no severe airway complications (both P>0.05). Conclusions Continuous nebulization therapy after lung transplantation may effectively improve pulmonary function, reduce the annual incidence of pulmonary infections, and play a positive role in the long-term maintenance of pulmonary function.
8.Clinical trial of Morinda officinalis oligosaccharides in the continuation treatment of adults with mild and moderate depression
Shu-Zhe ZHOU ; Zu-Cheng HAN ; Xiu-Zhen WANG ; Yan-Qing CHEN ; Ya-Ling HU ; Xue-Qin YU ; Bin-Hong WANG ; Guo-Zhen FAN ; Hong SANG ; Ying HAI ; Zhi-Jie JIA ; Zhan-Min WANG ; Yan WEI ; Jian-Guo ZHU ; Xue-Qin SONG ; Zhi-Dong LIU ; Li KUANG ; Hong-Ming WANG ; Feng TIAN ; Yu-Xin LI ; Ling ZHANG ; Hai LIN ; Bin WU ; Chao-Ying WANG ; Chang LIU ; Jia-Fan SUN ; Shao-Xiao YAN ; Jun LIU ; Shou-Fu XIE ; Mao-Sheng FANG ; Wei-Feng MI ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):815-819
Objective To observe the efficacy and safety of Morinda officinalis oligosaccharides in the continuation treatment of mild and moderate depression.Methods An open,single-arm,multi-center design was adopted in our study.Adult patients with mild and moderate depression who had received acute treatment of Morinda officinalis oligosaccharides were enrolled and continue to receive Morinda officinalis oligosaccharides capsules for 24 weeks,the dose remained unchanged during continuation treatment.The remission rate,recurrence rate,recurrence time,and the change from baseline to endpoint of Hamilton Depression Scale(HAMD),Hamilton Anxiety Scale(HAMA),Clinical Global Impression-Severity(CGI-S)and Arizona Sexual Experience Scale(ASEX)were evaluated.The incidence of treatment-related adverse events was reported.Results The scores of HAMD-17 at baseline and after treatment were 6.60±1.87 and 5.85±4.18,scores of HAMA were 6.36±3.02 and 4.93±3.09,scores of CGI-S were 1.49±0.56 and 1.29±0.81,scores of ASEX were 15.92±4.72 and 15.57±5.26,with significant difference(P<0.05).After continuation treatment,the remission rate was 54.59%(202 cases/370 cases),and the recurrence rate was 6.49%(24 cases/370 cases),the recurrence time was(64.67±42.47)days.The incidence of treatment-related adverse events was 15.35%(64 cases/417 cases).Conclusion Morinda officinalis oligosaccharides capsules can be effectively used for the continuation treatment of mild and moderate depression,and are well tolerated and safe.
9.Automatic monitoring of adverse drug reaction of anti-tuberculosis and analysis of influencing factors
Kai ZHANG ; Xiao-Qin LU ; Zhi DONG
The Chinese Journal of Clinical Pharmacology 2024;40(7):1059-1062
Objective To provide reference for clinical rational drug use,the adverse drug reaction(ADR)automatic monitoring system was used to monitor ADR in patients treated with first-line anti-tuberculosis drugs.Methods A total of 1 147 tuberculosis patients hospitalized in the infection department of our hospital from 2019 to 2022 were selected to monitor the occurrence of ADR during the hospitalization.Univariate and multivariate analysis were used to study the risk factors affecting the incidence of ADR.Results After systematic screening and pharmacist review,a total of 598 cases of ADR related to first-line anti-tuberculosis drugs were found,with an incidence of 52.14%.ADR mainly affects the endocrine system,digestive system,and hepatobiliary system.The incidence of ADR in oral isoniazid is higher than that in intravenous drip and nebulization routes.The results of multivariate regression analysis showed that women and a history of hepatitis were independent risk factors for the occurrence of ADR(all P<0.05).Conclusion The incidence of ADR with anti-tuberculosis drugs is high.Women and patients with a history of hepatitis are high-risk groups for adverse drug reactions to anti-tuberculosis drugs.In clinical,safer drugs should be selected for such patients,and the occurrence of ADR should be closely monitored to reduce the impact of ADR on the treatment process.
10.HPLC-MS/MS method for monitoring digoxin in children with small volume of plasma
Zhi-Mei YANG ; Zhang-Ying FENG ; Ya-Bin QIN
The Chinese Journal of Clinical Pharmacology 2024;40(9):1331-1335
Objective To establish a high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method for therapeutic drug monitoring(TDM)of digoxin in children.Methods The plasma samples 10 μL were precipitated protein by acetonitrile.Then,the analytes were gradient eluted on a Phenomenex Kinetex EVO C18 column(30.0 mm × 2.1 mm,2.6 μm)by HPLC-MS/MS with mobile phase consisted of water(0.05%formic acid and 2 mmol·L-1 ammonium acetate)-methanol at the flow rate of 0.55 mL·min-1.The mass detection was performed in positive ionization mode using the electrospray ionization(ESI)source.Dynamic multiple reaction monitoring mode(dMRM)was used to quantify at m/z 798.6→651.5(digoxin)and m/z 801.6→654.5(digoxin-d3),respectively.The selectivity,standard curve,precision and extraction recoveries,matrix effect,and stability were investigated.Results The retention time of both digoxin and internal standard was 1.39 min.The linear range of digoxin in human plasma was among 0.25-8.00 ng·mL-1,a typical standard curve was y=18.08 × 10-2x+29.71 × 10-4(r2=0.995 77).The intra-day and inter-day accuracies of digoxin were less than 15%Extraction recovery rate was 91.00%-99.50%.Stability studies showed good results.Matrix factor normalized by internal standard was within acceptance criteria.The measurement results were in line with the national requirement of External quality evaluation.This method was fully verified and applied to determine the plasma digoxin concentrations of 65 pediatric patients.Conclusion This LC-MS/MS method was simple,rapid and accurate.It is approved appropriate and practical for the therapeutic drug monitoring of digoxin in routine clinical laboratory practice,especially for children.

Result Analysis
Print
Save
E-mail