1.Bear Bile Powder Ameliorates LPS-Induced Acute Lung Injury by Inhibiting CD14 Pathway and Improving Intestinal Flora: Exploration of "Fei (Lung)-Dachang (Large Intestine) Interaction" Theory.
Long CHENG ; Hui-Ling TIAN ; Hong-Yuan LEI ; Ying-Zhou WANG ; Ma-Jing JIAO ; Yun-Hui LIANG ; Zhi-Zheng WU ; Xu-Kun DENG ; Yong-Shen REN
Chinese journal of integrative medicine 2025;31(9):821-829
OBJECTIVE:
To explore the effect of bear bile powder (BBP) on acute lung injury (ALI) and the underlying mechanism.
METHODS:
The chemical constituents of BBP were analyzed by ultra-high-pressure liquid chromatography-mass spectrometry (UPLC-MS). After 7 days of adaptive feeding, 50 mice were randomly divided into 5 groups by a random number table (n=10): normal control (NC), lipopolysaccharide (LPS), dexamethasone (Dex), low-, and high-dose BBP groups. The dosing cycle was 9 days. On the 12th and 14th days, 20 µL of Staphylococcus aureus solution (bacterial concentration of 1 × 10-7 CFU/mL) was given by nasal drip after 1 h of intragastric administration, and the mice in the NC group was given the same dose of phosphated buffered saline (PBS) solution. On the 16th day, after 1 h intragastric administration, 100 µL of LPS solution (1 mg/mL) was given by tracheal intubation, and the same dose of PBS solution was given to the NC group. Lung tissue was obtained to measure the myeloperoxidase (MPO) activity, the lung wet/dry weight ratio and expressions of CD14 and other related proteins. The lower lobe of the right lung was obtained for pathological examination. The concentrations of inflammatory cytokines including interleukin (IL)-6, tumour necrosis factor α (TNF-α ) and IL-1β in the bronchoalveolar lavage fluid (BALF) were detected by enzyme linked immunosorbent assay, and the number of neutrophils was counted. The colonic contents of the mice were analyzed by 16 sRNA technique and the contents of short-chain fatty acids (SCFAs) were measured by gas chromatograph-mass spectrometer (GC-MS).
RESULTS:
UPLC-MS revealed that the chemical components of BBP samples were mainly tauroursodeoxycholic acid and taurochenodeoxycholic acid sodium salt. BBP reduced the activity of MPO, concentrations of inflammatory cytokines, and inhibited the expression of CD14 protein, thus suppressing the activation of NF-κB pathway (P<0.05). The lung histopathological results indicated that BBP significantly reduced the degree of neutrophil infiltration, cell shedding, necrosis, and alveolar cavity depression. Moreover, BBP effectively regulated the composition of the intestinal microflora and increased the production of SCFAs, which contributed to its treatment effect (P<0.05).
CONCLUSIONS
BBP alleviates lung injury in ALI mouse through inhibiting activation of NF-κB pathway and decreasing expression of CD14 protein. BBP may promote recovery of ALI by improving the structure of intestinal flora and enhancing metabolic function of intestinal flora.
Animals
;
Acute Lung Injury/pathology*
;
Lipopolysaccharides
;
Ursidae
;
Gastrointestinal Microbiome/drug effects*
;
Bile/chemistry*
;
Lipopolysaccharide Receptors/metabolism*
;
Powders
;
Male
;
Lung/drug effects*
;
Mice
;
Peroxidase/metabolism*
;
Signal Transduction/drug effects*
;
Cytokines/metabolism*
2.Application of Assessment Scales in Palliative Care for Glioma: A Systematic Review.
Zhi-Yuan XIAO ; Tian-Rui YANG ; Ya-Ning CAO ; Wen-Lin CHEN ; Jun-Lin LI ; Ting-Yu LIANG ; Ya-Ning WANG ; Yue-Kun WANG ; Xiao-Peng GUO ; Yi ZHANG ; Yu WANG ; Xiao-Hong NING ; Wen-Bin MA
Chinese Medical Sciences Journal 2025;40(3):211-218
BACKGROUND AND OBJECTIVE: Patients with glioma experience a high symptom burden and have diverse palliative care needs. However, the assessment scales used in palliative care remain non-standardized and highly heterogeneous. To evaluate the application patterns of the current scales used in palliative care for glioma, we aim to identify gaps and assess the need for disease-specific scales in glioma palliative care. METHODS: We conducted a systematic search of five databases including PubMed, Web of Science, Medline, EMBASE, and CINAHL for quantitative studies that reported scale-based assessments in glioma palliative care. We extracted data on scale characteristics, domains, frequency, and psychometric properties. Quality assessments were performed using the Cochrane ROB 2.0 and ROBINS-I tools. RESULTS: Of the 3,405 records initially identified, 72 studies were included. These studies contained 75 distinct scales that were used 193 times. Mood (21.7%), quality of life (24.4%), and supportive care needs (5.2%) assessments were the most frequently assessed items, exceeding half of all scale applications. Among the various assessment dimensions, the Distress Thermometer (DT) was the most frequently used tool for assessing mood, while the Short Form-36 Health Survey Questionnaire (SF-36) was the most frequently used tool for assessing quality of life. The Mini Mental Status Examination (MMSE) was the most common tool for cognitive assessment. Performance status (5.2%) and social support (6.8%) were underrepresented. Only three brain tumor-specific scales were identified. Caregiver-focused scales were limited and predominantly burden-oriented. CONCLUSIONS: There are significant heterogeneity, domain imbalances, and validation gaps in the current use of assessment scales for patients with glioma receiving palliative care. The scale selected for use should be comprehensive and user-friendly.
Humans
;
Glioma/psychology*
;
Palliative Care/methods*
;
Quality of Life
;
Psychometrics
;
Brain Neoplasms/psychology*
3.Application progress of micro-CT and finite element analysis techniques in scaphoid bone research
Yuan LYU ; De-zhou ZHANG ; Hai-long QIAN ; Si-min WANG ; Chao-qun WANG ; Kun LI ; Jie CHEN ; Xue BAI ; Hai-long ZHAO ; Shao-jie ZHANG ; Yuan MA ; Zhi-jun LI ; Jun SHI ; Xing WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):168-173
The scaphoid bone is one of the important bone of hand,which is frequently injured and difficult to treat in clinical practice.Therefore,it is very important to deeply study the microstructure and biomechanical characteristics of the scaphoid bone for understanding its injury mechanism and optimizing treatment scheme.Microcomputed tomography(micro-CT)provides high-resolution imaging of bone tissue,while finite element analysis can help to simulate the stress distribution and behavioral patterns of the scaphoid bone under various physiological and pathological states.The high-resolution three-dimensional image of the scaphoid bone obtained by micro-CT technology can be used to construct finite element models of real anatomical structure of the scaphoid bone,thus achieving accurate simulation of the mechanical properties of the scaphoid bone.The fusion of these two advanced technologies provides a new perspective for revealing the structural and functional relationships and injury mechanism of the scaphoid bone.Therefore,this paper reviews the anatomical characteristics of the scaphoid bone and its biomechanical behavior in different states,emphasizing the specific applications and advantages of micro-CT and finite element analysis techniques in the study of the scaphoid bone.By summarizing the research findings in recent years,this paper provides novel scientific basis and methods for the diagnosis,treatment,and prevention of scaphoid bone-related disorders.
4.Optimization and clinical validation of ISET-ICC technical system for de-tection of circulating tumor cells
Zhi-kun ZHAO ; Ying MA ; Pang LI ; Sheng LI ; Zhen-dan WANG
Chinese Journal of Current Advances in General Surgery 2025;28(1):12-16
Objective:To optimize the previously established Improved Membrane Filtration(ISET)method for de-tecting circulating tumor cells(CTCs)and to develop and validate a new,reliable CTC detection method by combining it with immunofluorescence techniques.Methods:The study involved optimizing the CTC detection system using mixed samples of gastric cancer 803 cell lines and peripheral blood(PB)from healthy volunteers to simulate the peripheral blood of cancer patients.The optimized system was validated using peripheral blood samples from 23 patients with ad-vanced(Ⅲ/Ⅳ)cancer,employing the ISET technique combined with immunocytochemistry(ICC)and paraffin block im-munohistochemistry(IHC)identification techniques.A cohort of 74 patients with various cancer types was used to com-pare the diagnostic performance of the membrane filtration combined with immunofluorescence(ISET-ICC)system against the CTC-Biopsy and CellSearchTM methods.Results:By adding a red blood cell lysis step and increasing the membrane pore size to 10 μm,the filtration time of the ISET method was reduced by threefold.The ISET-ICC detection method achieved a CTC positivity rate of 65.2%.The combination of the ISET-ICC system with the cell paraffin block-IHC method enhanced the reliability of identifying circulating tumor cells undergoing epithelial-mesenchymal transition(EMT-CTCs).The ISET-ICC technique demonstrated a significantly higher CTC positivity rate(17.6%;13/74)within the study cohort compared to the CellSearchTM method,which showed a CTC positivity rate of 12.2%(9/74;x2=10.21,P=0.007).The difference in positive detection rates among patients at different stages was statistically significant(x2=3.64,P=0.029),with a notably higher CTC detection rate in stage Ⅳ patients compared to those in stages Ⅰ-Ⅲ(x2=6.76,P=0.001).Conclusion:The improved ISET-ICC system effectively detects CTCs across various cancer types and dem-onstrates greater accuracy compared to the CellSearchTM system.
5.Application progress of micro-CT and finite element analysis techniques in scaphoid bone research
Yuan LYU ; De-zhou ZHANG ; Hai-long QIAN ; Si-min WANG ; Chao-qun WANG ; Kun LI ; Jie CHEN ; Xue BAI ; Hai-long ZHAO ; Shao-jie ZHANG ; Yuan MA ; Zhi-jun LI ; Jun SHI ; Xing WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):168-173
The scaphoid bone is one of the important bone of hand,which is frequently injured and difficult to treat in clinical practice.Therefore,it is very important to deeply study the microstructure and biomechanical characteristics of the scaphoid bone for understanding its injury mechanism and optimizing treatment scheme.Microcomputed tomography(micro-CT)provides high-resolution imaging of bone tissue,while finite element analysis can help to simulate the stress distribution and behavioral patterns of the scaphoid bone under various physiological and pathological states.The high-resolution three-dimensional image of the scaphoid bone obtained by micro-CT technology can be used to construct finite element models of real anatomical structure of the scaphoid bone,thus achieving accurate simulation of the mechanical properties of the scaphoid bone.The fusion of these two advanced technologies provides a new perspective for revealing the structural and functional relationships and injury mechanism of the scaphoid bone.Therefore,this paper reviews the anatomical characteristics of the scaphoid bone and its biomechanical behavior in different states,emphasizing the specific applications and advantages of micro-CT and finite element analysis techniques in the study of the scaphoid bone.By summarizing the research findings in recent years,this paper provides novel scientific basis and methods for the diagnosis,treatment,and prevention of scaphoid bone-related disorders.
6.Optimization and clinical validation of ISET-ICC technical system for de-tection of circulating tumor cells
Zhi-kun ZHAO ; Ying MA ; Pang LI ; Sheng LI ; Zhen-dan WANG
Chinese Journal of Current Advances in General Surgery 2025;28(1):12-16
Objective:To optimize the previously established Improved Membrane Filtration(ISET)method for de-tecting circulating tumor cells(CTCs)and to develop and validate a new,reliable CTC detection method by combining it with immunofluorescence techniques.Methods:The study involved optimizing the CTC detection system using mixed samples of gastric cancer 803 cell lines and peripheral blood(PB)from healthy volunteers to simulate the peripheral blood of cancer patients.The optimized system was validated using peripheral blood samples from 23 patients with ad-vanced(Ⅲ/Ⅳ)cancer,employing the ISET technique combined with immunocytochemistry(ICC)and paraffin block im-munohistochemistry(IHC)identification techniques.A cohort of 74 patients with various cancer types was used to com-pare the diagnostic performance of the membrane filtration combined with immunofluorescence(ISET-ICC)system against the CTC-Biopsy and CellSearchTM methods.Results:By adding a red blood cell lysis step and increasing the membrane pore size to 10 μm,the filtration time of the ISET method was reduced by threefold.The ISET-ICC detection method achieved a CTC positivity rate of 65.2%.The combination of the ISET-ICC system with the cell paraffin block-IHC method enhanced the reliability of identifying circulating tumor cells undergoing epithelial-mesenchymal transition(EMT-CTCs).The ISET-ICC technique demonstrated a significantly higher CTC positivity rate(17.6%;13/74)within the study cohort compared to the CellSearchTM method,which showed a CTC positivity rate of 12.2%(9/74;x2=10.21,P=0.007).The difference in positive detection rates among patients at different stages was statistically significant(x2=3.64,P=0.029),with a notably higher CTC detection rate in stage Ⅳ patients compared to those in stages Ⅰ-Ⅲ(x2=6.76,P=0.001).Conclusion:The improved ISET-ICC system effectively detects CTCs across various cancer types and dem-onstrates greater accuracy compared to the CellSearchTM system.
7.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
8.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
9.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
10.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.

Result Analysis
Print
Save
E-mail