1.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
2.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
3.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
4.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
5.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
6.Comparison of differences in dosimetry and treatment efficiency of modified radiotherapy plans after left-sided breast-conserving surgery
Jian-hai LIN ; Jing FENG ; Zhong-hua CHEN ; Zhi-chao FU ; Jie CHEN ; Nan-bao ZHONG
Chinese Medical Equipment Journal 2025;46(4):45-51
Objective To compare the differences in dosimetry and treatment efficiency of three radiotherapy plans after left-sided breast-conserving surgery,including modified intensity-modulated radiation therapy(IMRT),cross-field volume-modulated arc therapy(VMAT)or improved VMAT,so as to provide references for clinical practice.Methods Three radiotherapy plans of modified IMRT,cross-field VMAT and improved VMAT were designed for 12 patients after left-sided-breast-conserving surgery.The modified IMRT with five irradiation fields and the improved VMAT with two arcs were modified by not setting cross-fields while determining the start and end angles with the rays passing through the least lung area.The cross-field VMAT had its start and end angles set based on the cross-fields.The doses to the target areas,peripheral organs at risk,heart and its substructures were evaluated,and dose verification was carried out.The three plans were compared in terms of treatment efficiency and gamma pass rate.SPSS 22.0 was used for statistical analysis.Results All the three plans behaved well in dose distribution.In terms of planning gross tumor volume dosimetry dosimetry,the improved VMAT and modified IMRT gained advantages than others in CI and D50,respectively,with the differences being significant(all P<0.05).In terms of planning target volume dosimetry,the modified IMRT had the V107 and D50 lower than those of the others,with the differences being significant(P<0.05).In terms of the protection of peripheral organs at risk,V5 of the left lung,Dmean of the right lung and Dmean of the healthy breast were lower in the modified IMRT plan than in the other 2 plans,with statistically significant differences(P<0.05);V20,V30,V35 and V40 of the left lung were lower in the modified VMAT plan than in the other 2 plans,with statistically significant differences(P<0.05).In terms of protection of heart and its substructures,the left ventricle V20,V30 and Dmean of the improved VMAT plan behaved better than those of other 2 plans,and the difference was statistically significant(all P<0.05).In terms of treatment efficiency,the cross-field VMAT plan had the lowest MU while highest treatment efficiency;the improved VMAT plan had the MU higher while the treatment efficiency lower than the cross-field VMAT plan;the modified IMRT plan had the highest MU while the lowest gamma pass rate,and the differences in the MUs and gamma pass rates among the three plans were statistically significant(P<0.05).Conclusion Under the same standard conditions,the cross-field VMAT and improved VMAT plans show technical advantages.Though the improved VMAT plan has the treatment efficiency lower than the cross-field VMAT,it decreases the possibility of radiocardiac injury in terms of dosimetry and thus can be used for radiotherapy after left-sided breast-conserving surgery.[Chinese Medical Equipment Journal,2025,46(4):45-51]
7.Pharmacological effects of linarin on Aβ deposition and neuroinflammation in APP/PS1 mice
Pei-zhi MAO ; Ying-yan YAN ; Zeng-ze YAN ; Jian-hua QI ; Long-hu WANG ; Qi-jun CHEN
Chinese Pharmacological Bulletin 2025;41(4):661-667
Aim To investigate the effect of linarin on improving cognitive behavior of APP/PS1 mice,and to explore the therapeutic effect of linarin on A β deposi-tion and neuroinflammation and its correlation.Meth-ods APP/PS1 transgenic mice were randomly divid-ed into the model group,high-dose group,medium-dose group,low-dose group and positive control group.C57BL/6J mice were set as the normal group.Morris water maze was used to evaluate the learning and mem-ory abilities of mice.TUNEL staining was used to de-tect the apoptosis of neurons in the CA1 region of mice.IHC was used to detect the expression levels of Aβ42 and GFAP.Western blot was used to detect the expression levels of BACE1 and PS-1.Results Com-pared with the normal group,mice of the model group showed lower NCP,shorter target quadrant travel,less target quadrant residence time percentage(all P<0.01),higher apoptosis rate of neurons in the CA1 re-gion(P<0.01),significantly higher protein expres-sion levels of A β42 and GFAP(all P<0.01),and significantly higher protein expression levels of BACE1 and PS-1(all P<0.01).Compared with the model group,the medium-dose group,high-dose group and positive control group showed higher NCP,longer tar-get quadrant travel,more target quadrant residence time percentage(all P<0.05),lower apoptosis rate of neurons in the CA1 region(P<0.01),significantly lower protein expression levels of A β42 and GFAP(all P<0.01),and significantly lower protein expression levels of BACE1 and PS-1(all P<0.01).Conclu-sions Linarin can inhibit two key enzymes to reduce the decomposition of APP and the generation of A β42,thereby inhibiting the activation of astrocytes,allevia-ting neuroinflammation,improving the core pathologi-cal features of AD,and thus significantly improving learning and memory impairment in APP/PS1 mice.
8.Moxibustion combined with low-dose tadalafil for diabetes mellitus-induced erectile dysfunction: A prospective, single-center, three-arm randomized controlled trial.
Tao LIU ; Zhao-Xu YANG ; Yan XU ; Qi ZHAO ; Xue LIU ; Xin-Fei HUANG ; Zhi-Xing SUN ; Yun CHEN ; Jian-Huai CHEN
National Journal of Andrology 2025;31(2):55-60
OBJECTIVE:
To investigate the clinical efficacy of moxibustion (Mox) combined with low-dose tadalafil (TAD) in the treatment of diabetes mellitus-induced erectile dysfunction (DMED) with the syndrome of Qi deficiency and blood stasis.
METHODS:
According to the inclusion and exclusion criteria, we selected 90 patients with DMED for this trial and equally randomized them into a Mox, a TAD, and a Mox combined with TAD (Mox+TAD) group to be treated by mild Mox applied to the acupoints Zusanli, Sanyinjiao and Yinlingquan qd alt, oral medication with low-dose TAD at 5 mg per dose qd, and combination of the above two therapies, respectively, all for 4 weeks. We obtained from the patients their IIEF-5 scores, traditional Chinese medicine (TCM) symptoms scores, Erectile Hardness Scale (EHS) scores, corpus cavernosal hemodynamic indexes, and the peak systolic velocity (PSV), end diastolic velocity (EDV) and resistance index (RI) of the corpus cavernosal arteries before and after treatment, and compared them among the three groups.
RESULTS:
The total effectiveness rate was significantly higher in the Mox+TAD (90.0%) than in the Mox (46.7%) and TAD groups (60.0%) (P< 0.05). Compared with the baseline, the IIEF-5 and EHS scores were increased, while the TCM symptoms scores decreased in all the three groups after treatment, more significantly in the Mox+TAD group than in the other two (P< 0.05). And the PSV and RI were remarkably increased, while the EDV decreased (P< 0.05) in all the three groups (P< 0.05) after treatment, with PSV even higher in the Mox+TAD than in the Mox and TAD groups (P< 0.05).
CONCLUSION
Moxibustion combined with tadalafil has a definite efficacy and safety for the treatment of DMED, which can effectively improve the erectile function of the patients by increasing penile blood supply, benefiting qi and activating blood circulation.
Humans
;
Male
;
Tadalafil
;
Erectile Dysfunction/etiology*
;
Moxibustion
;
Middle Aged
;
Prospective Studies
;
Adult
;
Carbolines/administration & dosage*
;
Diabetes Complications/therapy*
;
Aged
;
Treatment Outcome
;
Combined Modality Therapy
9.Robot-assisted percutaneous coronary intervention: a prospective, multicenter, randomized controlled, non-inferiority clinical trial.
Yi YU ; Zheng CHEN ; Zhi-Jian WANG ; Yue-Ping LI ; Li-Xia YANG ; Jing QI ; Jing XIE ; Tao HUANG ; Dong-Mei SHI ; Yu-Jie ZHOU
Journal of Geriatric Cardiology 2025;22(8):725-735
OBJECTIVE:
To evaluate the safety and effectiveness of robot-assisted percutaneous coronary intervention (R-PCI) compared to traditional manual percutaneous coronary intervention (M-PCI).
METHODS:
This prospective, multicenter, randomized controlled, non-inferior clinical trial enrolled patients with coronary heart disease who met the inclusion criteria and had indications for elective percutaneous coronary intervention. Participants were randomly assigned to either the R-PCI group or the M-PCI group. Primary endpoints were clinical and technical success rates. Clinical success was defined as visually estimated residual post-percutaneous coronary intervention stenosis < 30% with no 30-day major adverse cardiac events. Technical success in the R-PCI group was defined as successful completion of percutaneous coronary intervention using the ETcath200 robot-assisted system, without conversion to M-PCI in the event of a guidewire or balloon/stent catheter that was unable to cross the vessel or was poorly supported by the catheter. Secondary endpoints included total procedure time, percutaneous coronary intervention procedure time, fluoroscopy time, contrast volume, operator radiation exposure, air kerma, and dose-area product.
RESULTS:
The trial enrolled 152 patients (R-PCI: 73 patients, M-PCI: 79 patients). Lesions were predominantly B2/C type (73.6%). Both groups achieved 100% clinical success rate. No major adverse cardiac events occurred during the 30-day follow-up. The R-PCI group had a technical success rate of 100%. The R-PCI group had longer total procedure and fluoroscopy times, but lower operator radiation exposure. The percutaneous coronary intervention procedure time, contrast volume, air kerma, and dose-area product were similar between the two groups.
CONCLUSIONS
For certain complex lesions, performing percutaneous coronary intervention using the ETcath200 robot-assisted system is safe and effective and does not result in conversion to M-PCI.
10.Effectiveness of Lianhua Qingwen Granule and Jingyin Gubiao Prescription in Omicron BA.2 Infection and Hospitalization: A Real-World Study of 56,244 Cases in Shanghai, China.
Yu-Jie ZHANG ; Guo-Jian LIU ; Han ZHANG ; Chen LIU ; Zhi-Qiang CHEN ; Ji-Shu XIAN ; Da-Li SONG ; Zhi LIU ; Xue YANG ; Ju WANG ; Zhe ZHANG ; Lu-Ying ZHANG ; Hua FENG ; Yan-Qi ZHANG ; Liang TAN
Chinese journal of integrative medicine 2025;31(1):11-18
OBJECTIVE:
To examine the effectiveness of Chinese medicine (CM) Lianhua Qingwen Granule (LHQW) and Jingyin Gubiao Prescription (JYGB) in asymptomatic or mild patients with Omicron infection in the shelter hospital.
METHODS:
This single-center retrospective cohort study was conducted in the largest shelter hospital in Shanghai, China, from April 10, 2022 to May 30, 2022. A total of 56,244 asymptomatic and mild Omicron cases were included and divided into 4 groups, i.e., non-administration group (23,702 cases), LHQW group (11,576 cases), JYGB group (12,112 cases), and dual combination of LHQW and JYGB group (8,854 cases). The length of stay (LOS) in the hospital was used to assess the effectiveness of LHQW and JYGB treatment on Omicron infection.
RESULTS:
Patients aged 41-60 years, with nadir threshold cycle (CT) value of N gene <25, or those fully vaccinated preferred to receive CM therapy. Before or after propensity score matching (PSM), the multiple linear regression showed that LHQW and JYGB treatment were independent influence factors of LOS (both P<0.001). After PSM, there were significant differences in LOS between the LHQW/JYGB combination and the other groups (P<0.01). The results of factorial design ANOVA proved that the LHQW/JYGB combination therapy synergistically shortened LOS (P=0.032).
CONCLUSIONS
Patients with a nadir CT value <25 were more likely to accept CM. The LHQW/JYGB combination therapy could shorten the LOS of Omicron-infected individuals in an isolated environment.
Humans
;
Drugs, Chinese Herbal/therapeutic use*
;
Male
;
Female
;
Middle Aged
;
Adult
;
China/epidemiology*
;
Hospitalization
;
COVID-19 Drug Treatment
;
COVID-19/epidemiology*
;
SARS-CoV-2
;
Retrospective Studies
;
Treatment Outcome
;
Length of Stay
;
Young Adult
;
Aged


Result Analysis
Print
Save
E-mail