1.Research advance on the role of gut microbiota and its metabolites in juvenile idiopathic arthritis.
Ao-Hui PENG ; You-Jia CHEN ; Jin-Xuan GU ; Zhi-Gang JIN ; Xu-Bo QIAN
Acta Physiologica Sinica 2025;77(3):587-601
Juvenile idiopathic arthritis (JIA) is the most common condition of chronic rheumatic disease in children. JIA is an autoimmune or autoinflammatory disease, with unclear mechanism and limited treatment efficacy. Recent studies have found a number of alterations in gut microbiota and its metabolites in children with JIA, which are related to the development and progression of JIA. This review focuses on the influence of the gut microbiota and its metabolites on immune function and the intestinal mucosal barrier and discuss the key role of the gut-joint axis in the pathogenesis of JIA and emerging treatment methods based on gut microbiota and its metabolites. This review could help elucidate the pathogenesis of JIA and identify the potential therapeutic targets for the prevention and treatment of JIA.
Humans
;
Arthritis, Juvenile/physiopathology*
;
Gastrointestinal Microbiome/physiology*
;
Child
;
Intestinal Mucosa
2.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Construction and validation of a mortality risk prediction model after TIPS in patients with cirrhosis,portal hypertension,and esophagogastric variceal bleeding
Xiao-dong YANG ; Zhi-gang MA ; Xu WANG ; Li-li LIU ; Peng-li FENG
Chinese Journal of Current Advances in General Surgery 2025;28(11):853-858
Objective:To identify risk factors for mortality in patients with cirrhosis and portal hypertension compli-cated by esophagogastric variceal bleeding(EVB)after transjugular intrahepatic portosystemic shunt(TIPS),and to estab-lish a prediction model.Methods:Clinical data of 80 patients who underwent TIPS from March 2022 to March 2024 were retrospectively analyzed.Based on 28-day outcomes,patients were divided into survival(n=65)and death(n=15)groups.Univariate and multivariate logistic regression analyses were used to determine independent predictors,and the model's calibration and discrimination were assessed by the Hosmer-Lemeshow test and ROC curve.Results:Inde-pendent risk factors for death included Child-pugh score(OR=2.653),MELD score(OR=1.924),bleeding volume(OR=1.754),portal vein thrombosis(OR=3.247),and hepatic encephalopathy(OR=2.834).The model demonstrated good cali-bration(Hosmer-Lemeshow χ2=7.142,P=0.521)and discrimination,with an AUC of 0.873(95%CI:0.773-0.939),sensi-tivity of 83.3%,and specificity of 87.7%.Conclusion:Child-pugh score,MELD score,bleeding volume,portal vein thrombosis,and hepatic encephalopathy are independent predictors of post-TIPS mortality in cirrhotic patients with EVB.Emergency TIPS carries higher mortality risk than elective TIPS.The proposed model shows strong predictive perfor-mance and may aid in individualized prognosis assessment and therapeutic decision-making.
9.Interpretation of Ergonomic Principle for the Prevention of Work-Related Musculoskeletal Disorders Part 1: General Principles (T/WSJD 14.1-2020)
Qing XU ; Ning JIA ; Ruijie LING ; Gang LI ; Yimin LIU ; Huadong ZHANG ; Qingsong CHEN ; Qiuling ZHANG ; Zhi WANG ; Ying QU ; Xueyan ZHANG ; Yan YANG ; Zhongxu WANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2025;43(2):139-145
Ergonomic Principle for the Prevention of Work-Related Musculoskeletal Disorders Part 1: General Principles (T/WSJD 14.1-2020) is the first guideline standard for the prevention of work-related musculoskeletal disorders provided to employers and occupational health technical service institutions in China, which covers ergonomic risk factors and their hazard definition, ergonomic prevention principles, risk assessment process, risk control process and risk evaluation principles. The standard specifically clarify the specific types of adverse ergonomic risk factors and control strategies and the standard process of systematic ergonomic risk assessment, providing implementation paths and practical guidance for eliminating/reducing adverse ergonomic risks and enhance workplace environments to prevent work-related musculoskeletal disorders. This paper interprets and analyzes the background of standard establishment, formulation process, fundamental basis, and main content, etc., to provide scientific and accurate technical support for enterprise managers, labours and technical personnel of occupational health institutions to optimize the use of this standard.
10.Structural equation analysis and modeling of upper limb WMSDs and their adverse ergonomic factors
Siwu ZHONG ; Ning JIA ; Xin SUN ; Meibian ZHANG ; Qing XU ; Huadong ZHANG ; Ruijie LING ; Yimin LIU ; Gang LI ; Yan YIN ; Hua SHAO ; Jue LI ; Hengdong ZHANG ; Bing QIU ; Dayu WANG ; Qiang ZENG ; Rugang WANG ; Yan YE ; Bin XIAO ; Hua ZOU ; Jianchao CHEN ; Dongxia LI ; Yongquan LIU ; Qinghua SHI ; Jixiang LIU ; Enfei JIANG ; Jun QI ; Liangying MEI ; Xianfeng ZHAO ; Mimi YANG ; Xinwei GUO ; Zhi WANG ; Zhongxu WANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2025;43(4):254-263
Objective:To explore the structural relationship between WMSDs in the upper limbs and various risk factors in the occupational population in China, based on a large sample epidemiological survey and structural equation analysis, and to establish a structural equation model, so as to lay a foundation for the prevention and control of such diseases.Methods:The Chinese version of the Musculoskeletal Disorders Electronic Questionnaire was used to conduct a nationwide survey on the prevalence of WMSDs in the upper extremity. Six factors related to WMSDs in the upper extremity were extracted by the classification standard of adverse ergonomic factors and their source and confirmatory factor analysis, including work organization, work type, upper extremity work posture, individual factors, upper extremity fatigue and upper extremity WMSDs. The structural equation analysis was carried out and the structural equation model was established.Results:The incidence of WMSDs and fatigue in the upper limbs was 24.44% and 43.76%, respectively. The adjusted structural equation model fitting indicators were generally up to the standard (GFI=1.000, AGFI=1.000, RMSEA=0.043, NFI=0.808, TLI=0.784) . The four exogenous latent variables of work organization, work type, upper limb work posture and individual factors were correlated. There was a strong positive correlation between job type and upper limb work posture ( r=0.865) , a moderate positive correlation between work organization and job type and upper limb work posture ( r=0.570, 0.490) , and a weak negative correlation between individual factors and the other three exogenous latent variables. Upper limb work posture and individual factors had direct effects on upper limb WMSDs, and the effect coefficients were 0.10 and 0.06, respectively. Upper limb fatigue played a mediating role between work organization, work type, upper limb work posture and upper limb WMSDs. The effect coefficient was 0.46, and the composition ratios of indirect effects were 100.0%, 100.0%, and 38.3%, respectively. The direct path effect of upper limb work posture, individual factors and upper limb WMSDs was weaker than the mediating path through upper limb fatigue. Conclusion:When carrying out the prevention and control of upper limbWMSDs, it is necessary to comprehensively consider the pathogenesis path of upper limb muscle fatigue and upper limb WMSDs caused by work organization, work type, and upper limb work posture, so as to provide theoretical reference for improving the prevention and control level of such diseases.

Result Analysis
Print
Save
E-mail