1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.The Invariant Neural Representation of Neurons in Pigeon’s Ventrolateral Mesopallium to Stereoscopic Shadow Shapes
Xiao-Ke NIU ; Meng-Bo ZHANG ; Yan-Yan PENG ; Yong-Hao HAN ; Qing-Yu WANG ; Yi-Xin DENG ; Zhi-Hui LI
Progress in Biochemistry and Biophysics 2025;52(10):2614-2626
ObjectiveIn nature, objects cast shadows due to illumination, forming the basis for stereoscopic perception. Birds need to adapt to changes in lighting (meaning they can recognize stereoscopic shapes even when shadows look different) to accurately perceive different three-dimensional forms. However, how neurons in the key visual brain area in birds handle these lighting changes remains largely unreported. In this study, pigeons (Columba livia) were used as subjects to investigate how neurons in pigeon’s ventrolateral mesopallium (MVL) represent stereoscopic shapes consistently, regardless of changes in lighting. MethodsVisual cognitive training combined with neuronal recording was employed. Pigeons were first trained to discriminate different stereoscopic shapes (concave/convex). We then tested whether and how light luminance angle and surface appearance of the stereoscopic shapes affect their recognition accuracy, and further verify whether the results rely on specify luminance color. Simultaneously, neuronal firing activity of neurons was recorded with multiple electrode array implanted from the MVL during the presentation of difference shapes. The response was finally analyzed how selectively they responded to different stereoscopic shapes and whether their selectivity was affected by the changes of luminance condition (like lighting angle) or surface look. Support vector machine (SVM) models were trained on neuronal population responses recorded under one condition (light luminance angle of 45°) and used to decode responses under other conditions (light luminance angle of 135°, 225°, 315°) to verify the invariance of responses to different luminance conditions. ResultsBehavioral results from 6 pigeons consistently showed that the pigeons could reliably identify the core 3D shape (over 80% accuracy), and this ability wasn’t affected by changes in light angle or surface appearance. Statistical analysis of 88 recorded neurons from 6 pigeons revealed that 83% (73/88) showed strong selectivity for specific 3D shapes (selectivity index>0.3), and responses to convex shapes were consistently stronger than to concave shapes. These shape-selective responses remained stable across changes in light angle and surface appearance. Neural patterns were consistent under both blue and orange lighting. The decoding accuracy achieves above 70%, suggesting stable responses under different conditions (e.g., different lighting angles or surface appearance). ConclusionNeurons in the pigeon MVL maintain a consistent neural encoding pattern for different stereoscopic shapes, unaffected by illumination or surface appearance. This ensures stable object recognition by pigeons in changing visual environments. Our findings provide new physiological evidence for understanding how birds achieve stable perception (“invariant neural representations”) while coping with variations in the visual field.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Research progress in the role of HCN channels in Alzheimer's disease.
Xiao-Juan LI ; Bo ZHENG ; Ping LAN ; Wen-Xin ZHANG ; Yi-Peng LI ; Zhi HE
Acta Physiologica Sinica 2025;77(5):867-875
Alzheimer's disease (AD) is the commonest neurodegenerative disease that causes memory decline, cognitive dysfunction and behavior disorders in the aged people. Primary pathological hallmarks of AD include amyloid-β (Aβ), neurofibrillary tangles (NFTs), gliosis, and neuronal loss. Hyperpolarization-activated cyclic nucleotide-gated (HCN) channels have important physiological functions, especially in aspects of controlling the resting membrane potential, pacemaker activity, memory formation, sleep and arousal. This article reviews the structure, distribution, regulation of HCN channels and the role of HCN channels in the pathological mechanisms of AD, aiming to provide drug therapeutic targets for the prevention and treatment of AD.
Humans
;
Alzheimer Disease/physiopathology*
;
Hyperpolarization-Activated Cyclic Nucleotide-Gated Channels/physiology*
;
Animals
;
Amyloid beta-Peptides/metabolism*
8.Anti-tumor effect of metal ion-mediated natural small molecules carrier-free hydrogel combined with CDT/PDT.
Wen-Min PI ; Gen LI ; Xin-Ru TAN ; Zhi-Xia WANG ; Xiao-Yu LIN ; Hai-Ling QIU ; Fu-Hao CHU ; Bo WANG ; Peng-Long WANG
China Journal of Chinese Materia Medica 2025;50(7):1770-1780
Metal ion-promoted chemodynamic therapy(CDT) combined with photodynamic therapy(PDT) offers broad application prospects for enhancing anti-tumor effects. In this study, glycyrrhizic acid(GA), copper ions(Cu~(2+)), and norcantharidin(NCTD) were co-assembled to successfully prepare a natural small-molecule, carrier-free hydrogel(NCTD Gel) with excellent material properties. Under 808 nm laser irradiation, NCTD Gel responded to the tumor microenvironment(TME) and acted as an efficient Fenton reagent and photosensitizer, catalyzing the conversion of endogenous hydrogen peroxide(H_2O_2) within the tumor into oxygen(O_2), and hydroxyl radicals(·OH, type Ⅰ reactive oxygen species) and singlet oxygen(~1O_2, type Ⅱ reactive oxygen species), while depleting glutathione(GSH) to stabilize reactive oxygen species and alleviate tumor hypoxia. In vitro and in vivo experiments demonstrated that NCTD Gel exhibited significant CDT/PDT synergistic therapeutic effects. Further safety evaluation and metabolic testing confirmed its good biocompatibility and safety. This novel hydrogel is not only simple to prepare, safe, and cost-effective but also holds great potential for clinical transformation, providing insights and references for the research and development of metal ion-mediated hydrogel-based anti-tumor therapies.
Hydrogels/chemistry*
;
Animals
;
Photochemotherapy
;
Humans
;
Mice
;
Antineoplastic Agents/administration & dosage*
;
Photosensitizing Agents/chemistry*
;
Neoplasms/metabolism*
;
Female
;
Copper/chemistry*
;
Reactive Oxygen Species/metabolism*
;
Tumor Microenvironment/drug effects*
;
Cell Line, Tumor
;
Male
9.Fourth national survey of traditional Chinese medicine resources and protection of traditional knowledge of medication use among ethnic minorities.
Jiang-Wei DU ; Xiao-Bo ZHANG ; Jian-Zhi CUI ; Shao-Hua YANG ; Hai-Tao LI ; Zhi-Yong LI ; Lu-Qi HUANG
China Journal of Chinese Materia Medica 2025;50(9):2349-2355
Traditional Chinese medicine(TCM) resources are the essential material foundation for the development of TCM. The national survey of TCM resources serves as a periodic summary of these resources, ensuring the continuity, prosperity, and development of TCM in China. Since 1949, four national surveys of TCM resources have been conducted. The fourth survey incorporated an investigation into traditional knowledge related to TCM resources, including the traditional medicinal knowledge of Chinese ethnic minorities, with the goal of systematically exploring, preserving, and inheriting this knowledge. This manuscript provides an overview of the basic findings from the first three national surveys of TCM resources, while also clarifying the concepts, categories, forms, carriers, and acquisition pathways of traditional knowledge related to TCM resources. A preliminary summary of the findings from traditional knowledge investigations reported in current literature is also presented. Based on the fourth survey, this manuscript emphasizes the urgency of developing public medical knowledge through empirically-based investigations, the excavation, and compilation of traditional knowledge. It also outlines the potential for conducting "precise" investigations based on first-hand data obtained from the survey, as well as facilitating the discovery and evaluation of new medicines using traditional knowledge related to ethnic minority medicinal practices. This manuscript is expected to provide valuable insights for promoting the health and industrial development of ethnic minority populations in the post-"survey" phase.
Humans
;
Medicine, Chinese Traditional
;
China/ethnology*
;
Minority Groups
;
Ethnicity
;
Drugs, Chinese Herbal/therapeutic use*
;
Health Knowledge, Attitudes, Practice/ethnology*
;
Surveys and Questionnaires
10.Application scenarios of rare and endangered Chinese medicinal materials and their substitutes.
Wen-Ting HU ; Xiao-Bo ZHANG ; Yi-Jing ZHANG ; Zhi-Yong LI ; Lan-Ping GUO ; Lu-Qi HUANG
China Journal of Chinese Materia Medica 2025;50(10):2640-2647
Traditional Chinese medicine(TCM) resources are an important foundation for the theory and practice of TCM. Rare and endangered TCM, as a significant component of these resources, plays an essential role. Conducting research on substitutes for rare and endangered TCM resources is of great significance for alleviating resource shortages, promoting the sustainable utilization of TCM, and advancing TCM modernization. This paper reviews the conservation achievements of rare and endangered Chinese medicinal materials in China and organizes the substitution methods for these materials. Currently, the main substitution approaches include introduction and domestication, tissue culture, varietal replacement, and artificial synthesis. Furthermore, this paper proposes the following approaches for researching the application scenarios of rare and endangered medicinal materials, i.e., tracing the historical context of their use to clarify foundational principles; verifying disease classifications to strengthen the clinical application scenarios of these materials; analyzing the evolution patterns of prescription formulations to strengthen the mining of the compatibility application scenarios of rare and endangered medicinal materials; scientifically evaluating to strengthen the application scenario research and development of endangered Chinese patent medicine industry. These efforts aim to promote the scientific substitution and sustainable utilization of rare and endangered medicinal materials and their substitutes.
Drugs, Chinese Herbal/chemistry*
;
Humans
;
Medicine, Chinese Traditional
;
China
;
Plants, Medicinal/growth & development*
;
Endangered Species
;
Conservation of Natural Resources
;
Animals

Result Analysis
Print
Save
E-mail