1.Comparison of efficacy and safety of oral mucosa grafts and acellular dermal matrix grafts in the treatment of long-segment urethral stricture.
Wenyuan LENG ; Duan GAO ; Xiaoyu LI ; Wei ZUO ; Weimin HU ; Zhenpeng ZHU ; Chunru XU ; Jian LIN ; Xuesong LI
Journal of Peking University(Health Sciences) 2025;57(5):975-979
OBJECTIVE:
To investigate the differential efficacy and safety profiles of oral mucosa (OM) grafts compared with acellular dermal matrix (ADM) grafts in the surgical management of long-segment urethral strictures.
METHODS:
A retrospective cohort study was conducted involving 27 patients who underwent graft urethroplasty for long-segment urethral strictures in Peking University First Hospital, spanning from May 2010 to September 2023. The patient cohort comprised 14 individuals who received OM grafts and 13 who underwent ADM grafts. The participants were stratified into two groups based on the type of grafts material utilized during surgery. The demographic and clinical baseline characteristics included an average age of (43.3±14.0) years in the OM group and (54.2±15.9) years in the ADM group. The mean body mass index (BMI) for the respective groups were (24.7±4.3) kg/m2 for OM and (25.4±4.8) kg/m2 for ADM. Etiological differences were noted, with idiopathic causes predominantly in the OM cohort and lichen sclerosus in the ADM cohort.
RESULTS:
The surgical interventions were successfully executed for all the patients. The median stricture length was 4.5 (2.5, 9.0) cm for the OM group and 5.0 (2.0, 14.0) cm for the ADM group (P=0.555). The median operative duration was 160 (71, 221) min for the OM group and 134 (112, 274) min for the ADM group (P=0.065). The catheterization durations was 1.5 (1.0, 6.0) months for the OM group and 3.0 (1.0, 3.0) months for the ADM group. The median postoperative follow-up duration was 12.5 (1.0, 170.0) months for the OM group and 59.0 (3.0, 142.0) months for the ADM group. The surgical success rates were 50.00% in the OM group and 53.85% in the ADM group. No statistically significant differences were observed in postoperative quality of life (QoL) or international prostate symptom score (IPSS) at the final follow-up. The stricture-free survival rates did not differ significantly (HR=0.875, 95%CI: 0.507-1.511, P=0.6). In terms of safety, three patients in the OM group experienced sexual dysfunction, and two had oral complications, whereas the ADM group had one case of postoperative infection.
CONCLUSION
The findings suggest that ADM grafts are comparable to OM grafts in terms of efficacy and safety for the treatment of long-segment urethral strictures, including complex cases attributed to lichen sclerosus. However, given the small sample size of this study, the above conclusions may have certain limitations. Larger cohort studies will be needed in the future to further validate these findings.
Humans
;
Urethral Stricture/surgery*
;
Acellular Dermis
;
Mouth Mucosa/transplantation*
;
Retrospective Studies
;
Middle Aged
;
Male
;
Adult
;
Treatment Outcome
;
Skin Transplantation/methods*
;
Aged
2.Value of contrast enhanced ultrasound combined with elastography in differential diagnosis of non-mass-like lesions on breast
Ying CHANG ; Jingchun YANG ; Zhenpeng LENG ; Lan DU
Journal of Chinese Physician 2017;19(10):1504-1508
Objective To explore the diagnostic value of contrast enhanced ultrasound (CEUS),elastography and their combined use in diagnosing non-mass-like lesions on breast.Methods From November 2015 to January 2017,79 nodules diagnosed by conventional ultrasound were prospectively enrolled and examined by CEUS and elastography before surgery.Multivariate logistic regression models were established for CEUS and CEUS combined with elastography to diagnose breast malignancy.The diagnostic performances of CEUS,elastography and their combined use were evaluated with the receiver operating characteristic (ROC) curve.Results The CEUS features significantly predicting malignancy were hyperenhancement,heterogeneous enhancement,visualization of penetrating vessels (P < 0.01).Furthermore,the multivariate logistic regression for CEUS combined with elastography showed that heterogeneous enhancement,visualization of penetrating vessels and elasticity score were the independent predictors of breast malignancy.The area under the ROC curve of CEUS combined with elastography was (0.915 ± 0.223),which was higher than that of CEUS and elatography (0.851 ±0.029,0.790 ±0.038,P <0.05).Moreover,the sensitivity,and accuracy of CEUS combined with elastography were 89.1%,and 86.1%,respectively.The omission diagnostic rate of CEUS combined with elastography (8.9%) was reduced.The diagnostic accuracy of CEUS combined with elastography was significantly higher than that of CEUS and elastography.Conclusions The diagnostic value of CEUS combined with elastography was remarkably significant in the differential diagnosis of non-mass-like lesions on breast.
3.Logistic regression analysis of multi-mode ultrasonography in the diagnosis of thyroid carcinoma
Zhenpeng, LENG ; Jingchun, YANG ; Huijuan, MA ; Jia, MA ; Meijie, REN ; Ying, CHANG ; Hua, KANG ; Lianghong, TENG
Chinese Journal of Medical Ultrasound (Electronic Edition) 2016;13(12):918-924
Objective To evaluate the diagnostic value of gray-scale ultrasonography (GSU) combined with contrast-enhanced ultrasonography (CEUS) and real-time elastography imaging (EI) in solid thyroid nodules.Methods A total of 124 solid nodules were collected from Xuanwu Hospital of Capital Medical University from September 2011 to November 2014, including 49 benign nodules and 75 malignant nodules conifrmed by surgical pathology. The data of multimodal imaging were retrospectively analyzed and compared with the pathological results. The parameters among the groups were compared byχ2 test. Four diagnostic models including the statistically signiifcant independent variables were established accord to different combinations of routine ultrasound examination. The binary Logistic regression equation using the pathological results as the dependent variable Y and the ultrasound features of thyroid nodules as independent variableX was established for calculating the area under the receiver operator curve (ROC) and multiple regression analysis furthermore.Results There were statistically significant differences in aspect ratio, margin condition, echo type, CEUS features, elastic imaging score and elastic strain rate of benign and malignant thyroid nodules(χ2=13.966, 7.106, 24.215, 17.250 and 27.158,P<0.05).The four Logistic regression models were statistically signiifcant (χ2=5.37, 5.37, 8.155, 8.155, allP<0.05). By using modelⅠ,Ⅱ,Ⅲ andⅣ, the diagnostic sensitivity, speciifcity and accuracy of malignant nodules were (73.8%, 75.9%, 79.7%, 83.3%), (67.5%, 70.7%, 85.2%, 86.7%), and (71.8%, 74.2% 81.8%, 84.4%) respectively. The area under the ROC of logistic equation predicted values were (0.778, 0.809, 0.875 and 0.898, allP<0.01). Multivariate categorical analysis showed that aspect ratio, margin condition and the elastic strain rate ratio (χ2=13.73, 7.541 and 11.461, allP<0.05) of thyroid nodules were effective diagnostic indicators. Conclusions Our study indicated that CEUS and EI could be helpful modality for GSU to improve the diagnostic accuracy of thyroid nodules. The combined application of multi mode ultrasound examination has a high diagnostic value.
4.Value of contrast enhanced ultrasound combined with elastography in differential diagnosis of thyroid imaging reporting and data system 4 thyroid nodules
Huijuan, MA ; Jingchun, YANG ; Zhenpeng, LENG ; Jia, MA ; Hua, KANG ; Lianghong, TENG
Chinese Journal of Medical Ultrasound (Electronic Edition) 2016;13(12):911-917
Objective To assess the diagnostic value of contrast enhanced ultrasound (CEUS),elastography and their combined use in diagnosing thyroid nodules of thyroid imaging reporting and data system (TI-RADS) 4. Methods From November 2011 to August 2016, 159 TI-RADS 4 nodules diagnosed by conventional ultrasound were prospectively enrolled and examined by CEUS and elastography before surgery. Multivariate logistic regression models were established for CEUS and CEUS combined with elastography to diagnose thyroid malignancy. The diagnostic performances of CEUS, elastography and their combined use were evaluated with the receiver operating characteristic (ROC) curve. The sensitivity,specificity, accuracy, positive predictive value, negative predictive value and omission diagnostic rate of CEUS, elastography and their combined use were compared by Chi-square test. Results The CEUS features significantly predicting malignancy were heterogeneous enhancement, hypoenhancement, without or incomplete ring-enhancement and later time to peak than the surrounding parenchyma (χ2=24.378, 69.194,29.434 and 7.375, all P < 0.01). Furthermore, the multivariate logistic regression for CEUS combined with elastography showed that heterogeneous enhancement, ring enhancement and elasticity score were the independent predictors of thyroid malignancy. The area under the ROC curve of CEUS combined with elastography was (0.921±0.023) which was higher than that of CEUS and elatography (0.88±0.029 and 0.80±0.038, respectively; both P < 0.05). Moreover, the sensitivity, accuracy and negative predictive value of CEUS combined with elastography were 92.1%, 86.2% and 84.6%, respectively. The omission diagnostic rate of CEUS combined with elastography (7.9%) was reduced. And the diagnostic accuracy of CEUS combined with elastography was significantly higher than that of CEUS and elastography (P < 0.05). While the diagnostic accuracy of CEUS was close to the elastography, the difference was not statistically significant (P > 0.05). Conclusion The diagnostic value of CEUS combined with elastography was remarkably significant in the differential diagnosis of TI-RADS 4 nodules.

Result Analysis
Print
Save
E-mail