1.The effect of tympanic membrane opening on middle ear pressure:an in vitro model of patulous eustachian tube
Haoze ZHANG ; Fangyuan WANG ; Xiaolong LI ; Mengyuan GUO ; Zhenhao FU ; Jingcheng ZHOU ; Yulin DING ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(6):538-543
Objective To study the impact of tympanic membrane opening on respiratory-driven middle ear pressure in patients with patulous eustachian tube(PET),using a simplified in vitro model.Methods CT imaging data from a PET patient(with full-length eustachian tube opening observed during a Valsalva maneuver followed by breath-holding)were used to design a simplified eustachian tube model.Two simplified in vitro models of the eusta-chian tube were constructed using silicone-based 3D printing technology and connected to a pressure controller and pressure sensors.The pressure controller was activated to introduce negative-pressure airflow into the nasopharyn-geal model to simulate respiratory-induced middle ear pressure fluctuations.A hemostat was used to alternately open and close the external interface of the middle ear chamber,simulating conditions of an open and intact tympanic membrane,while middle ear pressure was continuously monitored using pressure sensors.Results In the first mod-el,with-800 mbar negative pressure applied at the nasopharynx,the middle ear pressure stabilized between-3.9 mbar and-4.3 mbar with tympanic membrane opening,and between-7.9 mbar and-8.2 mbar with intact tym-panic membrane.In the second model,under the same pressure setting,middle ear pressure stabilized between-2.7 mbar and-3.1 mbar with tympanic membrane opening,and between-5.0 mbar and-7.7 mbar with intact tympanic membrane.Conclusion This study,based on a simplified in vitro model,demonstrates that tympanic membrane opening can effectively reduce respiratory-driven pressure in the middle ear.This phenomenon may partly explain the clinical efficacy of tympanostomy tube insertion in certain PET patients.
2.Efficacy analysis of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tubo-plasty on patulous eustachian tube
Jingcheng ZHOU ; Zhenhao FU ; Fangyuan WANG ; Jianping JIA ; Danheng ZHAO ; Ya LIU ; Li ZHU ; Kun HOU ; Mengyuan GUO ; Haoze ZHANG ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):418-423
Objective This study aimed to investigate the efficacy of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tuboplasty(MEACETT)in patients with patulous eustachian tube(PET).Meth-ods A retrospective analysis was conducted on the clinical data of 27 patients(30 ears)diagnosed with PET who underwent MEACETT.Autologous cartilage was used through the incision at the posterior end of the inferior turbi-nate and filled into the lateral wall of the pharyngeal orifice of the eustachian tube.Without affecting the movement function of the eustachian tube during swallowing,the collapse of the pharyngeal orifice was fully filled.Before and after the surgery,the visual analogue scale(VAS),the eustachian tube dysfunction questionnaire-7(ETDQ-7)and hospital anxiety and depression scale(HADS)was used for assessment to evaluate the surgical efficacy.Results There was no significant difference in depression scores before and after surgery(P>0.05).However,postopera-tive anxiety scores,ETDQ-7 scores,and VAS scores were significantly lower than preoperative scores(P<0.05).Among the 27 patients,9 showed significant symptom relief,13 exhibited partial relief,and 5 had no significant change compared to preoperative symptoms.The overall response rate of the treatment(significant relief and partial relief)was 81.48%(22/27).All surgeries were successfully performed.Except for secretory otitis media occurring in 2 cases,no major complications were observed.Conclusion MEACETT demonstrates significant symptom relief in PET patients,with high surgical safety and low complication rates,making it worthy of clinical promotion.
3.Research on the diagnostic efficiency of the"R"value of tubomanometry in detecting patulous eusta-chian tube
Zhenhao FU ; Jingcheng ZHOU ; Jianping JIA ; Fangyuan WANG ; Danheng ZHAO ; Ya LIU ; Haoze ZHANG ; Mengyuan GUO ; Li ZHU ; Kun HOU ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):429-433
Objective To evaluate the diagnostic efficacy of the R value in tubomanometry(TMM)for the di-agnosis of patulous eustachian tube(PET).Methods The clinical data of 58 patients with PET and 65 controls were retrospectively analyzed.TMM was performed on both groups under nasopharyngeal pressures of 30,40,and 50 mbar respectively.The diagnostic efficacy of the R value for PET was evaluated through receiver operating char-acteristic(ROC)curves.Results In the control group,the average R values under nasopharyngeal pressures of 30,40,and 50 mbar were 0.86±0.50,0.76±0.41,and 0.68±0.34 respectively.In contrast,the corresponding R values in the PET group were significantly lower,which were 0.56±0.38,0.50±0.36,and 0.46±0.38 respec-tively.According to the ROC curve analysis,the areas under the curve(AUC)at these pressures were 0.62,0.74,and 0.74 respectively.The specificity and sensitivity of the R value under nasopharyngeal pressures of 30,40,and 50 mbar were 76.90%and 54.30%,74.60%and 68.10%,86.90%and 54.30%,respectively.Under pressures of 30,40,and 50 mbar,the incidence rates of R>1 in the control group and the PET group were 29.23%(38/130)and 12.77%(12/94)(x2=8.69,P=0.003),20.00%(26/130)and 6.38%(6/94)(x2=7.20,P=0.007),10.00%(13/130)and 3.19%(3/94)(x2=2.87,P=0.09)respectively.Conclusion Although the low R value in TMM reflects the presence of PET to some extent,it does not provide adequate sensitivity and specificity to serve as an independent diagnostic criterion for PET.
4.The effect of tympanic membrane opening on middle ear pressure:an in vitro model of patulous eustachian tube
Haoze ZHANG ; Fangyuan WANG ; Xiaolong LI ; Mengyuan GUO ; Zhenhao FU ; Jingcheng ZHOU ; Yulin DING ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(6):538-543
Objective To study the impact of tympanic membrane opening on respiratory-driven middle ear pressure in patients with patulous eustachian tube(PET),using a simplified in vitro model.Methods CT imaging data from a PET patient(with full-length eustachian tube opening observed during a Valsalva maneuver followed by breath-holding)were used to design a simplified eustachian tube model.Two simplified in vitro models of the eusta-chian tube were constructed using silicone-based 3D printing technology and connected to a pressure controller and pressure sensors.The pressure controller was activated to introduce negative-pressure airflow into the nasopharyn-geal model to simulate respiratory-induced middle ear pressure fluctuations.A hemostat was used to alternately open and close the external interface of the middle ear chamber,simulating conditions of an open and intact tympanic membrane,while middle ear pressure was continuously monitored using pressure sensors.Results In the first mod-el,with-800 mbar negative pressure applied at the nasopharynx,the middle ear pressure stabilized between-3.9 mbar and-4.3 mbar with tympanic membrane opening,and between-7.9 mbar and-8.2 mbar with intact tym-panic membrane.In the second model,under the same pressure setting,middle ear pressure stabilized between-2.7 mbar and-3.1 mbar with tympanic membrane opening,and between-5.0 mbar and-7.7 mbar with intact tympanic membrane.Conclusion This study,based on a simplified in vitro model,demonstrates that tympanic membrane opening can effectively reduce respiratory-driven pressure in the middle ear.This phenomenon may partly explain the clinical efficacy of tympanostomy tube insertion in certain PET patients.
5.Efficacy analysis of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tubo-plasty on patulous eustachian tube
Jingcheng ZHOU ; Zhenhao FU ; Fangyuan WANG ; Jianping JIA ; Danheng ZHAO ; Ya LIU ; Li ZHU ; Kun HOU ; Mengyuan GUO ; Haoze ZHANG ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):418-423
Objective This study aimed to investigate the efficacy of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tuboplasty(MEACETT)in patients with patulous eustachian tube(PET).Meth-ods A retrospective analysis was conducted on the clinical data of 27 patients(30 ears)diagnosed with PET who underwent MEACETT.Autologous cartilage was used through the incision at the posterior end of the inferior turbi-nate and filled into the lateral wall of the pharyngeal orifice of the eustachian tube.Without affecting the movement function of the eustachian tube during swallowing,the collapse of the pharyngeal orifice was fully filled.Before and after the surgery,the visual analogue scale(VAS),the eustachian tube dysfunction questionnaire-7(ETDQ-7)and hospital anxiety and depression scale(HADS)was used for assessment to evaluate the surgical efficacy.Results There was no significant difference in depression scores before and after surgery(P>0.05).However,postopera-tive anxiety scores,ETDQ-7 scores,and VAS scores were significantly lower than preoperative scores(P<0.05).Among the 27 patients,9 showed significant symptom relief,13 exhibited partial relief,and 5 had no significant change compared to preoperative symptoms.The overall response rate of the treatment(significant relief and partial relief)was 81.48%(22/27).All surgeries were successfully performed.Except for secretory otitis media occurring in 2 cases,no major complications were observed.Conclusion MEACETT demonstrates significant symptom relief in PET patients,with high surgical safety and low complication rates,making it worthy of clinical promotion.
6.Research on the diagnostic efficiency of the"R"value of tubomanometry in detecting patulous eusta-chian tube
Zhenhao FU ; Jingcheng ZHOU ; Jianping JIA ; Fangyuan WANG ; Danheng ZHAO ; Ya LIU ; Haoze ZHANG ; Mengyuan GUO ; Li ZHU ; Kun HOU ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):429-433
Objective To evaluate the diagnostic efficacy of the R value in tubomanometry(TMM)for the di-agnosis of patulous eustachian tube(PET).Methods The clinical data of 58 patients with PET and 65 controls were retrospectively analyzed.TMM was performed on both groups under nasopharyngeal pressures of 30,40,and 50 mbar respectively.The diagnostic efficacy of the R value for PET was evaluated through receiver operating char-acteristic(ROC)curves.Results In the control group,the average R values under nasopharyngeal pressures of 30,40,and 50 mbar were 0.86±0.50,0.76±0.41,and 0.68±0.34 respectively.In contrast,the corresponding R values in the PET group were significantly lower,which were 0.56±0.38,0.50±0.36,and 0.46±0.38 respec-tively.According to the ROC curve analysis,the areas under the curve(AUC)at these pressures were 0.62,0.74,and 0.74 respectively.The specificity and sensitivity of the R value under nasopharyngeal pressures of 30,40,and 50 mbar were 76.90%and 54.30%,74.60%and 68.10%,86.90%and 54.30%,respectively.Under pressures of 30,40,and 50 mbar,the incidence rates of R>1 in the control group and the PET group were 29.23%(38/130)and 12.77%(12/94)(x2=8.69,P=0.003),20.00%(26/130)and 6.38%(6/94)(x2=7.20,P=0.007),10.00%(13/130)and 3.19%(3/94)(x2=2.87,P=0.09)respectively.Conclusion Although the low R value in TMM reflects the presence of PET to some extent,it does not provide adequate sensitivity and specificity to serve as an independent diagnostic criterion for PET.

Result Analysis
Print
Save
E-mail