1.Next-generation clinically relevant antibody detection: Unlocking electrochemical biosensors for critical disease management.
Zheng ZHAO ; Zhiwei CHEN ; Jacques CROMMEN ; Shengfeng HUANG ; Qiqin WANG ; Zhengjin JIANG
Acta Pharmaceutica Sinica B 2025;15(11):5632-5662
Autoimmune diseases, cancers, and viral infections pose significant global health threats, characterized by chronic pathology, unregulated cellular proliferation, and rapid transmission, respectively, requiring urgent early warning and treatment strategies. Antibodies, primarily classified into autoantibodies and therapeutic antibodies based on their clinical roles, provide essential information and show considerable value in the precise diagnosis and treatment of these serious diseases. Among the technologies utilized in bioanalysis, electrochemical biosensors, with their unique advantages of rapid response, high sensitivity, miniaturization, cost-effectiveness and user-friendly operation, have been developed as a trending technology for precise diagnostic and therapeutic drug monitoring. This review systematically summarizes the relationships and roles of clinically relevant antibodies in autoimmune diseases, cancers, and viral infections, while detailing the composition, strategies, development, and application trends of relevant electrochemical biosensors. Furthermore, it highlights the remaining challenges and opportunities for the advancement and prospects of electrochemical sensors in the context of clinically relevant antibodies.
2.Multiepitope recognition technology promotes the in-depth analysis of antibody‒drug conjugates.
Yutian LEI ; Yuan SHEN ; Feng CHEN ; Rui HE ; Zhang ZHANG ; Ying ZHOU ; Jin-Chen YU ; Jacques CROMMEN ; Zhengjin JIANG ; Qiqin WANG
Acta Pharmaceutica Sinica B 2024;14(11):4962-4976
The dynamic tracking of antibody‒drug conjugates (ADCs) in serum is crucial. However, a versatile bioanalytical platform is lacking due to serious matrix interferences, the heterogeneity and complex biotransformation of ADCs, and the recognition deficiencies of traditional affinity technologies. To overcome this, a multiepitope recognition technology (MERT) was developed by simultaneously immobilizing CDR and non-CDR ligands onto MOF@AuNPs. MERT's excellent specificity, ultrahigh ligand density, and potential synergistic recognition ability enable it to target the different key regions of ADCs to overcome the deficiencies of traditional technologies. The binding capacity of MERT for antibodies is ten to hundred times higher than that of the mono-epitope or Fc-specific affinity technologies. Since MERT can efficiently capture target ADCs from serum, a novel bioanalytical platform based on MERT and RPLC‒QTOF-MS has been developed to monitor the dynamic changes of ADCs in serum, including the fast changes of drug-to-antibody ratio from 3.67 to 0.22, the loss of payloads (maytansinol), and the unexpected hydrolysis of the succinimide ring of the linker, which will contribute to clarify the fate of ADCs and provide a theoretical basis for future design. In summary, the MERT-based versatile platform will open a new avenue for in-depth studies of ADCs in biological fluids.
3.Comparative study of trastuzumab modification analysis using mono/multi-epitope affinity technology with LC-QTOF-MS.
Chengyi ZUO ; Jingwei ZHOU ; Sumin BIAN ; Qing ZHANG ; Yutian LEI ; Yuan SHEN ; Zhiwei CHEN ; Peijun YE ; Leying SHI ; Mao MU ; Jia-Huan QU ; Zhengjin JIANG ; Qiqin WANG
Journal of Pharmaceutical Analysis 2024;14(11):101015-101015
Dynamic tracking analysis of monoclonal antibodies (mAbs) biotransformation in vivo is crucial, as certain modifications could inactivate the protein and reduce drug efficacy. However, a particular challenge (i.e. immune recognition deficiencies) in biotransformation studies may arise when modifications occur at the paratope recognized by the antigen. To address this limitation, a multi-epitope affinity technology utilizing the metal organic framework (MOF)@Au@peptide@aptamer composite material was proposed and developed by simultaneously immobilizing complementarity determining region (CDR) mimotope peptide (HH24) and non-CDR mimotope aptamer (CH1S-6T) onto the surface of MOF@Au nanocomposite. Comparative studies demonstrated that MOF@Au@peptide@aptamer exhibited significantly enhanced enrichment capabilities for trastuzumab variants in comparison to mono-epitope affinity technology. Moreover, the higher deamidation ratio for LC-Asn-30 and isomerization ratio for HC-Asn-55 can only be monitored by the novel bioanalytical platform based on MOF@Au@peptide@aptamer and liquid chromatography-quadrupole time of flight-mass spectrometry (LC-QTOF-MS). Therefore, multi-epitope affinity technology could effectively overcome the biases of traditional affinity materials for key sites modification analysis of mAb. Particularly, the novel bioanalytical platform can be successfully used for the tracking analysis of trastuzumab modifications in different biological fluids. Compared to the spiked phosphate buffer (PB) model, faster modification trends were monitored in the spiked serum and patients' sera due to the catalytic effect of plasma proteins and relevant proteases. Differences in peptide modification levels of trastuzumab in patients' sera were also monitored. In summary, the novel bioanalytical platform based on the multi-epitope affinity technology holds great potentials for in vivo biotransformation analysis of mAb, contributing to improved understanding and paving the way for future research and clinical applications.
4.Rapid fabrication of zwitterionic sulfobetaine vinylimidazole-based monoliths via photoinitiated copolymerization for hydrophilic interaction chromatography
Qiqin WANG ; Lingjue SUN ; Huihui WU ; Ning DENG ; Xianglong ZHAO ; Jingwei ZHOU ; Tingting ZHANG ; Hai HAN ; Zhengjin JIANG
Journal of Pharmaceutical Analysis 2022;12(5):783-790
Zwitterionic sulfobetaine-based monolithic stationary phases have attracted increasing attention for their use in hydrophilic interaction chromatography.In this study,a novel hydrophilic polymeric monolith was fabricated through photo-initiated copolymerization of 3-(3-vinyl-1-imidazolio)-l-propanesulfonate(SBVI)with pentaerythritol triacrylate using methanol and tetrahydrofuran as the porogenic system.Notably,the duration for the preparation of this novel monolith was as little as 5 min,which was significantly shorter than that required for previously reported sulfobetaine-based monoliths prepared via conventional thermally initiated copolymerization.Moreover,these monoliths showed good morphology,permeability,porosity(62.4%),mechanical strength(over 15 MPa),column efficiency(51,230 plates/m),and reproducibility(relative standard deviations for all analytes were lower than 4.6%).Mechanistic studies indicated that strong hydrophilic and negative electrostatic interactions might be responsible for the retention of polar analytes on the zwitterionic SBVI-based monolith.In particular,the resulting monolith exhibited good anti-protein adhesion ability and low nonspecific protein adsorption.These excellent features seem to favor its application in bioanalysis.Therefore,the novel zwitterionic sulfobetaine-based monolith was successfully employed for the highly selective separation of small bioactive compounds and the efficient enrichment of N-glycopeptides from complex samples.In this study,we prepared a novel zwitterionic sulfobetaine-based monolith with good performance and developed a simpler and faster method for preparation of zwitterionic monoliths.
5.Phosphatidylethanolamine functionalized biomimetic monolith for immobilized artificial membrane chromatography
Peijie ZHU ; Weijia CHEN ; Qiqin WANG ; Huihui WU ; Meng RUAN ; Hongwu WANG ; Zhengjin JIANG
Journal of Pharmaceutical Analysis 2022;12(2):332-338
In this research,a new phospholipid based monolith was fabricated by in situ co-polymerization of 1-dodecanoyl-2-(11-methacrylamidoundecanoyl)-sn-glycero-3-phosphoethanolamine and ethylene dimethacrylate to mimick bio-membrane environment.Excellent physicochemical properties of this novel monolith that were achieved included column efficiency,stability,and permeability.Moreover,the biomimetic monolith showed outstanding separation capability for a series of intact proteins and small molecules.In particular,it exhibited good potential as an alternative to the commercial immobilized artificial membrane(IAM)column(IAM.PC.DD2)for studying drug-membrane interactions.This study not only enriched the types of IAM stationary phases,but also provided a simple model for the prediction of phosphatidylethanolamine related properties of drug candidates.
6.Editorial of Special Column "Natural Product Screening".
Acta Pharmaceutica Sinica B 2020;10(10):1798-1799
7.Determination of L-norvaline and L-tryptophan in dietary supplements by nano-LC using an O-2-(methacryloyloxy)-ethylcarbamoyl-10,11-dihydroquinidine-silica hybrid monolithic column
Dongsheng XU ; Elena SÁNCHEZ-LÓPEZ ; Qiqin WANG ; Zhengjin JIANG ; Luisa-María MARINA
Journal of Pharmaceutical Analysis 2020;10(1):70-77
An analytical methodology based on an O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-dihydroquinidine (MQD)-silica hybrid monolithic column was developed for the enantioseparation of 9-fluorenylmethoxycarbonyl (FMOC) derivatized amino acids by nano-liquid chromatography. The mo-bile phase was optimized including the apparent pH, content of ACN, and concentration of the buffer to obtain a satisfactory enantioresolution performance. 27 FMOC derivatized amino acids including 19 protein and 8 non-protein amino acids were tested, and 19 out of them were enantiomerically discriminated obtaining baseline separation for 11 of them. Analytical characteristics of the method were evaluated for norvaline and tryptophan in terms of linearity, precision, accuracy, limits of detection (LOD) and quantitation (LOQ) showing good performance to be applied to the enantiomeric determination of these amino acids in dietary supplements. LOD and LOQ values were 9.3 and 31μM for norvaline en-antiomers and 7.5 and 25μM for tryptophan enantiomers, respectively. The contents of D-norvaline and D-tryptophan were below their respective LODs in all the analyzed samples. Quantitation of L-tryptophan and L-norvaline showed good agreement with the labeled contents except for one sample which did not show presence of L-norvaline, contrary to the label indication.
8.Simultaneous determination of amino acids in different teas using supercritical fluid chromatography coupled with single quadrupole mass spectrometry
Yang HUANG ; Tiejie WANG ; Marianne FILLET ; Jacques CROMMEN ; Zhengjin JIANG
Journal of Pharmaceutical Analysis 2019;9(4):254-258
Tea is a widely consumed beverage and has many important physiological properties and potential health benefits. In this study, a novel method based on supercritical fluid chromatography coupled with mass spectrometry (SFC-MS) was developed to simultaneously determine 11 amino acids in different types of tea (green teas, Oolong tea, black tea and Pu-erh tea). The separation conditions for the analysis of the selected amino acids including the column type, temperature and backpressure as well as the type of additive, were carefully optimized. The best separation of the 11 amino acids was obtained by adding water (5%, v/v) and trifluoroacetic acid (0.4%, v/v) to the organic modifier (methanol). Finally, the developed SFC-MS method was fully validated and successfully applied to the determination of these amino acids in six different tea samples. Good linearity (r ! 0.993), precision (RSDs 2.99%), accuracy (91.95%e107.09%) as well as good sample stability were observed. The limits of detection ranged from 1.42 to 14.69 ng/mL, while the limits of quantification were between 4.53 and 47.0 ng/mL. The results indicate that the contents of the 11 amino acids in the six different tea samples are greatly influenced by the degree of fermentation. The proposed SFC-MS method shows a great potential for further investi-gation of tea varieties.

Result Analysis
Print
Save
E-mail