1.First-line Treatment with Furmonertinib Mesylate in Lung Adenocarcinoma Patient with EGFR Exon 20 Insertion Mutantion
LI ZHENGGUO ; WEI TING ; ZENG DUO ; ZHAO LI ; ZHANG JIANTING ; CHEN LAIXIU
Chinese Journal of Lung Cancer 2024;27(3):241-244
With the continuous innovation of genomics,proteomics and molecular biological detection technol-ogy,the treatment of non-small cell lung cancer(NSCLC)has changed from traditional chemotherapy to immunotherapy and targeted therapy.Among them,molecular tumor markers targeting tyrosine kinase pathways play more important roles in clinical practice.For advanced NSCLC patients with positive epidermal growth factor receptor(EGFR)mutations,there are many first-line drugs on the market and they could bring significant efficacy,thus completely subverting the treatment pattern of advanced NSCLC.Common mutations of EGFR in Chinese patients are located on exons 19,20 and 21,of which exons 19 and 21 mutations are the more common types.Besides,there is also a subtype of EGFR mutations,known as EGFR 20 exon insertion(EGFR 20ins)mutation.The authors summarized the treatment of a lung adenocarcinoma patient with EGFR 20ins mutation accepting Furmonertinib mesylate,in order to provide effective references for clinical diagnosis and treatment.
2.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
3.Three fixation methods in the revision of medial defective intertrochanteric fractures with failed treatment: a finite element analysis
Lin QI ; Wei ZHANG ; Zhengguo ZHU ; Shaobo NIE ; Jiaqi LI ; Hua CHEN ; Peifu TANG
Chinese Journal of Orthopaedics 2023;43(5):308-315
Objective:To compare the biomechanical differences of dynamic condylar screw (DCS), locking compression plate (LCP) combined with DCS and medial anatomic buttress plate (MABP) combined with DCS in the revision of medial defective intertrochanteric fractures by finite element analysis.Methods:The femoral CT imaging data provided by a healthy adult volunteer were used to reconstruct the solid three-dimensional model of femur by Mimics 21.0 and Geomagics Studio 12. Evans-Jensen II B intertrochanteric fracture was established by Ansys Workbench18.0. The three-dimensional models of proximal femoral nail antirotation (PFNA), DCS, LCP and MABP were reconstructed in Solidworks 2015. The PFNA was assembled with the fracture model, and then the PFNA was removed to establish the postoperative failure model of femoral intertrochanteric fracture and then simulated the fixation in the hip-preserving revision surgery of femoral intertrochanteric fractures: non-medial support reconstruction group (DCS); indirect medial support reconstruction group (DCS+LCP) and partial direct medial support reconstruction group (DCS+MABP). Finally, the forces on the hip joint of 70 kg normal people during standing (700 N), slow walking (1,400 N), brisk walking (1,750 N) and going up and down stairs (2,100 N) were simulated in Abaqus 6.14, the relative displacement and stress peak value of fracture end and stress distribution and stress peak value of internal fixation in different models were recorded.Results:At 700 N axial load, the relative displacement of fracture end fixed by DCS, DCS+LCP and DCS+MABP was 0.28, 0.13 and 0.09 mm; the peak stress of the fracture end was 49.01, 15.29 and 1.35 MPa; the peak stress of internal fixation was 230, 220 and 174 MPa, respectively. At 1,400 N axial load, the relative displacement of the fracture end of the three internal fixation methods was 0.56, 0.24 and 0.16 mm; the peak stress of fracture end was 108.49, 28.96 and 3.12 MPa; the peak stress of internal fixation was 469, 352 and 324 MPa, respectively. At 1,750 N axial load, the relative displacement of the fracture end of the three group was 0.70, 0.30 and 0.20 mm; the peak stress of the fracture end was 139.59, 37.57 and 4.17 MPa; the peak stress of internal fixation was 594, 421 and 393 MPa, respectively. At 2,100 N axial load, the relative displacement of the fracture end of the three internal fixation methods was 0.85, 0.35 and 0.23 mm; the peak stress of the fracture end was 170.05, 46.36 and 5.24 MPa; the peak stress of internal fixation was 724, 504 and 460 MPa, respectively.Conclusion:The partial direct reconstruction of medial support under the neck by DCS+MABP may have better biomechanical properties in the revision of medial defective intertrochanteric fractures.
4.Early effectiveness of computer navigation system-assisted transiliac-transsacral screws placement for posterior pelvic ring injuries.
Wenhao CAO ; Zhengguo ZHU ; Hongzhe QI ; Junjun TANG ; Wei ZHANG ; Jiaqi LI ; Shuangcheng LI ; Zhonghe WANG ; Changda LI ; Feng ZHOU ; Haoyang LIU ; Hua CHEN ; Peifu TANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1049-1054
OBJECTIVE:
To investigate the early effectiveness of transiliac-transsacral screws internal fixation assisted by augmented reality navigation system HoloSight (hereinafter referred to as "computer navigation system") in the treatment of posterior pelvic ring injuries.
METHODS:
A retrospective analysis was made in the 41 patients with posterior pelvic ring injuries who had been treated surgically with transiliac-transsacral screws between June 2022 and June 2023. The patients were divided into navigation group (18 cases, using computer navigation system to assist screw implantation) and freehand group (23 cases, using C-arm X-ray fluoroscopy to guide screw implantation) according to the different methods of transiliac-transsacral screws placement. There was no significant difference in gender, age, body mass index, causes of injuries, Tile classification of pelvic fracture, days from injury to operation, usage of unlocking closed reduction technique between the two groups ( P>0.05). The time of screw implantation, the fluoroscopy times, the guide wire adjustment times of each screw, and the incidence of complications were recorded and compared between the two groups. The position of the transiliac-transsacral screw was scanned by CT within 2 days after operation, and the position of the screw was classified according to Gras standard.
RESULTS:
The operation was successfully completed in both groups. The time of screw implantation, the fluoroscopy times, and the guide wire adjustment times of each screw in the navigation group were significantly less than those in the freehand group ( P<0.05). There were 2 cases of incision infection in the freehand group, and the incision healed by first intention after active dressing change; there was no screw-related complication in the navigation group during operation and early period after operation; the difference in incidence of complications between the two groups (8.7% vs. 0) was not significant ( P=0.495). According to the Gras standard, the screw position of the navigation group was significantly better than that of the freehand group ( P<0.05).
CONCLUSION
Compared with the traditional freehand method, the computer navigation system assisted transiliac-transsacral screws internal fixation in the treatment of posterior pelvic ring injuries has advantages of improving the accuracy of screw implantation and reducing radiation damage and the time of screw implantation.
Humans
;
Retrospective Studies
;
Surgical Wound Infection
;
Replantation
;
Body Mass Index
5.Biomechanical stability of endosteal augmentation for osteoporotic proximal humerus fracture: a finite element analysis
Zhengguo ZHU ; Wenhao CAO ; Zuhao CHANG ; Wei ZHANG ; Hao GUO ; Yang YU ; Na LIU ; Jiaqi LI ; Yonghui LIANG ; Hua CHEN ; Peifu TANG
Chinese Journal of Orthopaedic Trauma 2023;25(11):993-998
Objective:To explore which configuration schemes of proximal humerus internal locking system (PHILOS) fixation with endosteal augmentation can provide the optimal biomechanical stability for treatment of osteoporotic proximal humeral fractures by means of finite element analysis.Methods:Based on the CT data of the humerus of an old female volunteer (78 years old, with a bone density T-value of -3.0), a three-dimensional finite element model of the humerus was established by digital medical software such as Mimics 19.0, Geomagic Studio 12, and Creo 2.0 ANSYS Workbench2019. Next, a model of unstable proximal humerus fracture was established and subjected respectively to 5 different fixations: simple PHILOS fixation (PHILOS group), PHILOS plus 6-cm fibula fixation with calcar screws (PHILOS-F-C-6 group), PHILOS plus 6-cm fibula fixation without calcar screws (PHILOS-F-6 group), PHILOS plus 9-cm fibula fixation with calcar screws (PHILOS-F-C-9), and PHILOS plus 9-cm fibula fixation without calcar screws (PHILOS-F-9 group). After a stress mode of shoulder joint abduction at 25° was simulated, a compressive load of 200N was applied to the 5 fixation models. The stress distribution and displacement of fracture ends in different fixation models were tested, and the biomechanical stability was compared among the 5 different internal fixations.Results:Under a shoulder joint abduction at 25° and a load of 200 N, the maximum stress and the displacement of the fracture ends in PHILOS-F-C-9 group (38.678 Mpa and 0.012 mm) decreased by 30.08% and 45.45%, respectively, compared with PHILOS-F-C-6 group (55.321 Mpa and 0.022 mm), and decreased by 12.48% and 15.38%, respectively, in PHILOS-F-9 group (77.012 Mpa and 0.033 mm) compared with PHILOS-F-6 group (88.106 Mpa and 0.039 mm). The maximum stress and the displacement of the fracture ends in PHILOS-F-C-6 group decreased by 37.21% and 43.59%, respectively, compared with PHILOS-F-6 group while decreased by 49.83% and 63.63% in PHILOS-F-C-9 group compared with PHILOS-F-9 group, respectively.Conclusion:For treatment of osteoporotic proximal humeral fractures with medial instability, PHILOS fixation with longer fibula endosteal augmentation plus insertion of calcar screws is a more appropriate choice which can reduce the stress of internal fixation and reduce the displacement of the fracture ends.
6.Application of theranostic nuclide in the era of accelerator
Jinshui SHI ; Zhengguo CHEN ; Yang DU ; Li ZHOU ; Yu LIU ; Pengfei ZHU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2023;43(10):636-640
Irradiation based on accelerator is the main method of radionuclide production. In recent years, with the development of theranostics of nuclear medicine, there is a new demand for the preparation of accelerator radionuclides. In this paper, the nuclides and nuclide pairs of theranostics prepared by accelerators are divided into the three categories: nuclides of theranostics, nuclide pairs of theranostics of same element and different elements. The physical properties and current applications of some nuclides and nuclide pairs are introduced. The problems in the application of accelerator radionuclides preparation in China are analyzed, and the application prospect of the integration of accelerator radionuclides diagnosis and treatment is prospected.
7.Clinicopathological features micropapillary pattern of pure mucinous carcinoma of the breast
Xiaowei ZHANG ; Jing ZHANG ; Zhengguo XU ; Yan CHEN ; Bifei HUANG ; Guinv HU
Chinese Journal of Endocrine Surgery 2020;14(2):173-176
The clinicopathological features of 5 cases of micropapillary pattern of pure mucinous carcinoma (MPPPMC) of the breast were analyzed retrospectively. In this group, 5 cases of MPPPMC were all premenopausal women, whose age ranged from 37 to 48 years old. 3 cases had axillary lymph node metastasis, 3 cases had modified radical mastectomy, 1 case had breast conserving and sentinel lymph node biopsy, 1 case had breast conserving and axillary lymph node dissection, 1 case had oral endocrine drug and radiotherapy, 4 cases had oral endocrine drug and chemotherapy and radiotherapy, and 2 cases had oral targeted drug herceptin treatment. MPPPMC pattern is a kind of special type of pure mucinous carcinoma and invasive micropapillary carcinoma. The age of onset of this type is younger than that of mucinous carcinoma, and the prognosis of this type is worse than mucinous carcinoma. Whether it is an independent subtype of breast invasive micropapillary carcinoma or mucinous carcinoma has not reached consensus.
8. Analysis of reasons for failure of Meek micro-skin grafting in children with severe burn and treatment measures
Xingzhao LI ; Chen CAI ; Qinglian XU ; Delin HU ; Junhui SONG ; Zhengguo XIA
Chinese Journal of Burns 2019;35(7):525-531
Objective:
To analyze the reasons for failure of Meek micro-skin grafting in children with severe burns and to observe the clinical effects of the treatment measures.
Methods:
Thirty children with severe burns hospitalized in the First Affiliated Hospital of Anhui Medical University (hereinafter referred to as the author′s affiliation) from January 2012 to January 2018, conforming to the inclusion criteria were included to failed skin graft group. Children in failed skin graft group were performed with Meek micro-skin grafting operation and the operation failed, including 17 males and 13 females aged 1 to 12 year(s). Thirty children with severe burns hospitalized in the author′s affiliation during the same period of time, conforming to the inclusion criteria, were included to successful skin graft group. Children in successful skin graft group were performed with Meek micro-skin grafting operation and the operation succeeded, including 16 males and 14 females aged 1 to 12 year(s). Main treatment measures and effects before operation, area and survival rate of Meek micro-skin graft, infected pathogens status, selection status of sensitive antibiotics, preoperative nutrition status, and wound infection status in plum rain season of children in the two groups, and nutritional status before and after strengthening nutritional support of postoperative surviving children in failed skin graft group were analyzed retrospectively. Data were processed with chi-square test and
9.External pelvic reduction frame system combined with tunnel screw fixation for Tile C1 pelvic fracture
Hua CHEN ; Hongzho QI ; Zhengguo ZHU ; Yizhu GUO ; Xiangdang LIANG ; Peifu TANG
Chinese Journal of Trauma 2018;34(10):919-924
Objective To investigate the efficacy of external pelvic reduction frame system combined with tunnel screw fixation in the treatment of Tile C1 pelvic fracture.Methods A retrospective case series analysis of 15 patients with Tile C1 pelvic fractures from January 2014 to October 2016 was pedormed.Clinical data included seven males and eight females,aged 26-84 years (mean,48.9 years).According to Tile classification,there were five cases of type C1.1,three cases of C1.2,and seven cases of type C1.3.The average time from injury to surgery was 9.5 days (range,4-33 days).All patients received the treatment of external pelvic reduction frame system combined with tunnel screw fixation.The operation time,intraoperative blood loss,and complications were recorded.The fracture reduction quality was evaluated according to the Matta criteria,and the clinical function and neurological function were evaluated by the Majeed functional scoring system and the Gibbons sacral nerve injury grading,respectively.Results The patients were followed up for an average of 16 months (range,12-24 months).The mean operation time was 139 minutes (range,50-250 minutes),and the mean intraoperative blood loss was 90 ml (range,20-260 ml).No complications such as wound infection,loose internal fixation,rupture or loss of reduction occurred in the patients.According to the Matta score,14 patients obtained anatomical reduction,and one obtained satisfactory reduction.At the last follow-up,according to the Majeed functional scoring criteria,the results were excellent in all 15 patients,with an excellent and good rate of 100%.According to Gibbons sacral nerve injury grading,two out of the three patients with neurologic impairment before the operation recovered completely while the remaining one did not recover.Conclusion In the treatment of Tile C 1 pelvic fractures,external pelvic frame reduction system combined with tunnel screw fixation can attain satisfactory fracture reduction,reliable fixation,and good functional recovery.

Result Analysis
Print
Save
E-mail