1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Comparison of Wild and Cultivated Gardeniae Fructus Based on Traditional Quality Evaluation
Yuanjun SHANG ; Bo GENG ; Xin CHEN ; Qi WANG ; Guohua ZHENG ; Chun LI ; Zhilai ZHAN ; Junjie HU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(5):225-234
ObjectiveBased on traditional quality evaluation of Gardeniae Fructus(GF) recorded in historical materia medica, this study systematically compared the quality differences between wild and cultivated GF from morphological characteristics, microscopic features, and contents of primary and secondary metabolites. MethodsVernier calipers and analytical balances were used to measure the length, diameter and individual fruit weight of wild and cultivated GF, and the aspect ratio was calculated. A colorimeter was used to determine the chromaticity value of wild and cultivated GF, and the paraffin sections of them were prepared by safranin-fast green staining and examined under an optical microscope to observe their microstructure. Subsequently, the contents of water-soluble and alcohol-soluble extracts of wild and cultivated GF were detected by hot immersion method under the general rule 2201 in volume Ⅳ of the 2020 edition of the Pharmacopoeia of the People's Republic of China, the starch content was measured by anthrone colorimetric method, the content of total polysaccharides was determined by phenol-sulfuric acid colorimetric method, the sucrose content was determined by high performance liquid chromatography coupled with evaporative light scattering detection(HPLC-ELSD), and the contents of representative components in them were measured by ultra-performance liquid chromatography(UPLC). Finally, correlation analysis was conducted between quality traits and phenotypic traits, combined with multivariate statistical analysis methods such as principal component analysis(PCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA), key differential components between wild and cultivated GF were screened. ResultsIn terms of traits, the wild GF fruits were smaller, exhibiting reddish yellow or brownish red hues with significant variation between batches. While the cultivated GF fruits are larger, displaying deeper orange-red or brownish red. The diameter and individual fruit weight of cultivated GF were significantly greater than those of wild GF, while the blue-yellow value(b*) of wild GF was significantly higher than that of cultivated GF. In the microstructure, the mesocarp of wild GF contained numerous scattered calcium oxalate cluster crystals, while the endocarp contained stone cell class round, polygonal or tangential prolongation, undeveloped seeds were visible within the fruit. In contrast, the mesocarp of cultivated GF contained few calcium oxalate cluster crystals, or some batches exhibited extremely numerous cluster crystals. The stone cells in the endocarp were predominantly round-like, with the innermost layer arranged in a grid pattern. Seeds were basically mature, and only a few immature seeds existed in some batches. Regarding primary metabolite content, wild GF exhibited significantly higher total polysaccharide level than cultivated GF(P<0.01). In category-specific component content, wild GF exhibited significantly higher levels of total flavonoids and total polyphenols compared to cultivated GF(P<0.01). Analysis of 12 secondary metabolites revealed that wild GF exhibited significantly higher levels of Shanzhiside, deacetyl asperulosidic acid methyl ester, gardenoside and chlorogenic acid compared to cultivated GF(P<0.01). Conversely, the contents of genipin 1-gentiobioside, geniposide and genipin were significantly lower in wild GF(P<0.01). ConclusionThere are significant differences between wild and cultivated GF in terms of traits, microstructure, and contents of primary and secondary metabolites. At present, the quality evaluation system of cultivated GF remains incomplete, and this study provides a reference for guiding the production of high-quality GF medicinal materials.
3.Transverse dimensional changes following Twin-Block and slow maxillary expansion therapy in adolescents with Angle Class Ⅱ division 1 malocclusion: a cone-beam computed tomography study
PAN Yinti ; QIN Changtao ; ZHENG Yi ; GUO Anjie ; SUN Xin ; CHEN Zhixing ; MO Shuixue
Journal of Prevention and Treatment for Stomatological Diseases 2026;34(5):471-482
Objective:
To investigate the effects of a Twin-Block appliance combined with slow maxillary expansion (SME) on transverse dental and skeletal parameters in adolescent patients with Angle Class Ⅱ division 1 malocclusion, and to provide a reference for clinical orthodontic practice.
Methods:
This retrospective study was approved by the Institutional Ethics Committee. A total of 21 adolescents with Class Ⅱ division 1 malocclusion who underwent two-phase treatment with a Twin-Block appliance combined with SME at the Department of Orthodontics, College & Hospital of Stomatology, Guangxi Medical University, in 2021 to 2023 were consecutively enrolled. In the first phase, a functional appliance was used to coordinate the skeletal relationship between the maxilla and mandible by leveraging growth potential. In the second phase, a fixed appliance was employed for fine adjustments of the dental arches based on the specific condition. Cone-beam computed tomography (CBCT) scans were obtained before treatment (T0) and after the first phase of functional correction (T1). Transverse measurements at the first molar region, including molar buccolingual inclination, dental arch width, and basal bone width, were performed using Dolphin 3D Imaging software. Changes between T0 and T1 were statistically analyzed.
Results:
After the first phase of treatment, the left and right maxillary first molars showed a significant increase in buccal inclination by 5.47° ± 1.38° and 5.35° ± 1.61°, respectively (P<0.001). The arch width in the maxillary first molar region also increased by (2.68 ± 1.14) mm, and the basal bone width increased by (1.14 ± 1.24) mm (all P<0.001). The proportion of skeletal expansion accounted for an average of 42.86%, while dental expansion accounted for 57.14%. No statistically significant changes were observed in any mandibular transverse measurements (all P>0.05).
Conclusion
In adolescent patients with Angle Class Ⅱ division 1 malocclusion accompanied by maxillary transverse deficiency, Twin-Block appliance combined with SME can effectively expand maxillary dental arch and basal bone width while improving sagittal relationship, thereby correcting transverse discrepancy. The maxillary width changes were predominantly dental.
4.Dynamic prediction of JC polyomavirus reactivation after kidney transplantation
Mengyao LI ; Chengfeng ZHANG ; Difei REN ; Xin LIANG ; Shuyu CHEN ; Yushi PENG ; Yanjie WANG ; Meng ZHANG ; Jian XU ; Zheng CHEN ; Yun MIAO ; Yibin WANG
Organ Transplantation 2026;17(4):635-643
Objective To construct a dynamic prediction model for JC polyomavirus (JCV) reactivation after kidney transplantation. Methods A retrospective analysis was conducted on the clinical data of 128 recipients who met the inclusion criteria and received kidney transplantation in Nanfang Hospital, Southern Medical University, from June 2021 to December 2024. Dynamic Cox regression and dynamic restricted mean survival time (RMST) regression based on the landmark method were adopted to establish the dynamic prediction models, and Monte Carlo cross-validation was used to evaluate model performance. Results The dynamic models could predict the incidence and onset time of JCV reactivation within the subsequent 3 months according to covariates at each landmark time point from the 1st to the 6th month after transplantation. Remuzzi score, body mass index and warm ischemia time were independent risk factors for JCV reactivation, while a history of urinary BK polyomavirus reactivation served as a protective factor. The median values of the area under the curve, C-index and Brier score of the dynamic Cox model were 0.873, 0.851 and 0.065 respectively, and the C-index of the dynamic RMST model was 0.829, all of which were superior to those of the static model. Conclusions The landmark-based dynamic models exhibit excellent predictive performance, which may integrate baseline data and post-transplant follow-up information to realize dynamic assessment of the risk and time window of JCV reactivation, thereby providing evidence for optimizing post-operative monitoring and individualized intervention strategies.
5.Current awareness and optimization recommendations regarding the pneumonia with unknown etiology surveillance system among healthcare professionals in Shanghai
Qiwen FANG ; Chenyan JIANG ; Xin CHEN ; Huanyu WU ; Bihong JIN ; Xiaohuan GONG ; Shenghua MAO ; Qi QIU ; Ruobing HAN ; Huilin SHI ; Wenbin DONG ; Xin HU ; Jian CHEN ; Yaxu ZHENG
Shanghai Journal of Preventive Medicine 2026;38(6):482-487
ObjectiveTo investigate the current awareness and optimization recommendations on pneumonia with unknown etiology (PUE) surveillance among Shanghai healthcare professionals, and to provide evidence for the improvement of the surveillance system. MethodsIn December 2024, healthcare professional participants from diverse medical and health institutions were randomly selected within each stratum using a stratified cluster sampling method in all 16 districts of Shanghai for questionnaire surveys on their knowledge and suggestions for optimization of the PUE surveillance system. Descriptive statistics analyses, multivariate logistic regressions, and content analyses were used for data analyses. ResultsA total of 385 survey subjects were involved in the study, including 119 professional staffs from disease prevention and control centers and 266 from medical institutions. Those who understood the case definition for PUE correctly accounted for 67.01% (258/385). Multivariate regression model analyses showed that female gender (aOR=2.22, 95%CI: 1.36‒3.66), professionals from disease control institutions (aOR=2.02, 95%CI: 1.12‒3.72), and those who self-assessed as being familiar with the monitoring system (aOR=2.18, 95%CI:1.23‒3.89) had better understanding of the definition. Overall, 89.61% (345/385) of the survey subjects acknowledged the necessity of the surveillance system. Small number of cases meeting the case definition (54.46%, 214/379), insufficient diagnostic awareness (39.84%, 151/379), and lack of incentives for case reporting (29.29%, 111/379) were major problems for the current surveillance system, with variations observed across different types of institutions. Suggested segments for optimizing the surveillance system included monitoring purpose, case definition, form of monitoring and reporting procedure, organization mechanism, and epidemiological investigation and response. ConclusionThe necessity of PUE surveillance is commonly recognized among healthcare workers. However, the existing system falls short in terms of mastery of case definition and overall surveillance adaptability. There is an urgent need for optimization and improvement to enhance the capacity for preventing and controlling emerging and sudden respiratory infectious diseases.
6.Alanine transferase test results and exploration of threshold adjustment strategies for blood donors in Shenzhen, China
Xin ZHENG ; Yuanye XUE ; Haobiao WANG ; Litiao WU ; Ran LI ; Yingnan DANG ; Tingting CHEN ; Xiaoxuan XU ; Xuezhen ZENG ; Jinfeng ZENG
Chinese Journal of Blood Transfusion 2025;38(4):488-494
[Objective] To conduct a retrospective statistical comparison of alanine aminotransferase (ALT) test values in blood donors prior to blood collection, aiming to analyze the objective characteristics of the population with elevated ALT levels (ALT>50 U/L) and provide reference data for adjusting the screening eligibility threshold for ALT. [Methods] The preliminary ALT screening data of 30 341 blood donor samples collected prior to blood donation from three smart blood donation sites at the Shenzhen Blood Center between 2022 and 2023 were extracted and compared with data from a health examination department of a tertiary hospital in Shenzhen (representing the general population, n=24 906). Both datasets were categorized and statistically described. A retrospective analysis was conducted to examine the associations between ALT test results and factors such as donors' gender, age, ethnicity, donation site, donation season, and frequency of blood donation. [Results] The ALT levels in both blood donors and the general population were non-normally distributed. The 95th percentile of ALT values was calculated as 61.4 U/L (male: 67.8 U/L, female: 39.3 U/L) for blood donors and 58.1 U/L (male: 63.7 U/L, female: 51.2 U/L) for the general population. The non-compliance rates (ALT>50 U/L) were 7.65% (2 321/30 341) in blood donors and 7.08% (1 763/24 906) in the general population. There were significant differences (P<0.05) in the ALT failure rate among blood donors based on gender, age, and donation site, but no significant differences (P>0.05) during the blood donation season. There was no statistically significant difference (P>0.05) in the positive rates of four serological markers (HBsAg, anti HCV, HIV Ag/Ab, anti TP) for blood screening pathogens between ALT unqualified and qualified individuals (2.05% vs 1.5%). If the ALT qualification threshold was raised from 50 U/L to 90 U/L, the non qualification rates of male and female blood donors would decrease from 9.82% (2 074/21 125) to 2.23% (471/21 125) and from 2.70% (249/9 216) to 0.75% (69/9 216), respectively. Among the 154 blood donors who donated blood more than 3 times, 88.31% of the 248 ALT test results were in the range of 50-90 U/L. Among them, 9 cases had ALT>130 U/L, and ALT was converted to qualified in subsequent blood donations. [Conclusion] There are differences in the ALT failure rate among blood donors of different genders and ages, and different blood donation sites and operators can also affect the ALT detection values of blood donors. The vast majority of blood donors with ALT failure are caused by transient and non pathological factors. With the widespread use of blood virus nucleic acid testing, appropriately increasing the ALT qualification threshold for blood donors can expand the qualified population and alleviate the shortage of blood sources, and the risk of blood safety will not increase.
7.Analysis of abnormal ALT in blood donors in five Zang autonomous prefectures of Qinghai Province, China: characteristics and screening strategies
Yingnan DANG ; ; Rong TANG ; Liqin HUANG ; Hailin WU ; Tingting CHEN ; Shengju LI ; Yanli SUN ; Xin ZHENG ; Yanxia LI ; Xianlin YE ; Jinfeng ZENG
Chinese Journal of Blood Transfusion 2025;38(4):502-507
[Objective] To investigate the factors associated with alanine aminotransferase (ALT) abnormalities in multi-ethnic blood donors across five Zang autonomous prefectures in the plateau regions of Qinghai Province, and to provide evidence for ensuring blood safety and formulating screening strategies. [Methods] A retrospective analysis was performed on the ALT abnormal test results of blood donors in the Zang autonomous prefectures of Qinghai from 2022 to 2024. The correlations between ALT levels and factors including gender, age, altitude, and infectious markers were investigated. [Results] The overall ALT unqualified rate among blood donors in this region was 9.01%. Significant differences in ALT levels were observed across genders and age groups (P<0.05). Variations in ALT abnormality rates were also noted among different plateau regions (P<0.05). Overall, ALT values exhibited an increasing trend with rising altitude. The average ALT unqualified rates were 11.19% in Zang donors, 7.96% in Han donors, and 4.79% in donors from other ethnic groups (P<0.05). No statistically significant association was observed between ALT abnormality and the presence of HBV/HCV infectious markers (P>0.05). [Conclusion] In the plateau areas of Qinghai, multi-ethnic blood donors have a relatively high ALT levels and ALT unqualified rates, showing distinct regional characteristics. ALT elevation in voluntary blood donors is related to non-pathological factors such as gender, age, and dietary habits, but not to infectious indicators.
8.Effects of nail-tail transverse connection in treatment of atlantoaxial dislocation and its impacts on bone metabolism,serum vascular endothelial growth factor and fibroblast growth factor-2 levels
Qiuyu LI ; Jingjing CHEN ; Xin WANG ; Jiaoyang ZHENG ; Runqing LU ; Yifan WANG
Journal of Clinical Medicine in Practice 2025;29(19):53-57
Objective To explore the effects of nail-tail transverse connection in the treatment of atlantoaxial dislocation(AAD)and its impacts on bone metabolism,serum vascular endothelial growth factor(VEGF),and fibroblast growth factor-2(FGF-2)levels.Methods A total of 150 pa-tients with AAD were selected as the research subjects and divided into two groups using the random number table method,with 75 cases in each group.The observation group was treated with nail-tail transverse connection combined with posterior atlantoaxial pedicle screw internal fixation(C1-C2 PSR),while the control group was treated with C1-C2 PSR alone.Serum bone metabolism indicators[osteocalcin(BGP),type Ⅰ collagen N-terminal peptide(NTX),bone alkaline phosphatase(BALP),tartrate-resistant acid phosphatase(TRAP),type Ⅰ collagen carboxy-terminal peptide(CTX)],VEGF and FGF-2 levels were compared between the two groups at different time points.The Japanese Orthopaedic Association(JOA)score was used to evaluate the patients' neurological function before surgery and 3 years after surgery.Bone graft fusion was evaluated at 6 months,1 year,2 years,and 3 years after surgery.Results At 1,3 and 6 months after surgery,the serum VEGF and FGF-2 levels in the observation group were higher than those in the control group,and the differences were statistically significant(P<0.05).After treatment,the BALP,BGP,NTX,TRAP and CTX levels in both groups were lower than those before treatment,and their levels in the observation group were lower than those in the control group,with statistically significant differences(P<0.05).Before surgery,there was no statistically significant difference in the JOA scores be-tween the two groups(P>0.05).At 3 years after surgery,the JOA scores in both groups were higher than those before surgery,and the JOA score and the score improvement rate in the observa-tion group were higher than those in the control group,with statistically significant differences(P<0.05).At 6 months,1 year,2 years and 3 years after surgery,the success rate of bone graft fusion in the observation group was higher than that in the control group,with statistically significant differ-ences(P<0.05).Conclusion Nail-tail transverse connection has significant effects in the treat-ment of AAD,which can effectively improve patients' bone metabolism and increase the serum VEGF and FGF-2 levels.
9.Analysis of clinical characteristics and literature review of patients infected with Listeria monocytogenes
Xin ZHENG ; Yixiong ZHENG ; Xiaming JIANG ; Yao LUO ; Jing CHEN ; Jiaqi LIU ; Mure ALI ; Ziyi HE ; Huaicong LONG
Chinese Journal of Emergency Medicine 2025;34(4):528-532
Objective:To analyze the clinical characteristics, treatment strategies, and prognostic outcomes of patients infected with Listeria monocytogenes, thereby providing evidence-based insights for the prevention and control of this disease.Methods:A retrospective analysis was performed on the clinical data, diagnostic tests, treatment protocols, and prognostic outcomes of patients definitively diagnosed with Listeria monocytogenes infection at Sichuan Provincial People's Hospital over the past decade. Additionally, a comprehensive literature review was conducted, encompassing studies published between 2014 and 2024, sourced from CNKI, Wanfang Data, and PubMed. This review focused on summarizing the clinical features, treatment regimens, and prognostic outcomes of patients with Listeria monocytogenes infection.Results:The study cohort comprised 17 patients, with a mean age of (61.29 ± 16.24) years. The confirmed cases included 7 cases of bloodstream infections, 3 cases of central nervous system infections, and 7 cases of combined infections. Sepsis developed in 9 patients. The average time from symptom onset to the initiation of empirical antibiotic therapy was 72 hours, while the mean time to definitive diagnosis was 102 hours. Antimicrobial regimens predominantly featured penicillins, meropenem, and vancomycin. The average hospitalization duration was 16 days, with 9 patients experiencing adverse outcomes. A total of 78 relevant literature pieces were retrieved, encompassing data from 85 patients. The average age of these patients was (57.96 ± 16.48) years. Primary diagnostic methods relied on blood/cerebrospinal fluid cultures and Next-Generation Sequencing (NGS). Treatment regimens primarily involved antibiotics such as penicillins, aminoglycosides, carbapenems, and glycopeptides. Despite these interventions, the proportion of patients with poor prognosis remained significantly high at 30.6% (26/85). Logistic regression analysis identified sepsis and delayed antibiotic administration as independent predictors of poor prognosis.Conclusions:Listeriosis, caused by an opportunistic pathogen, necessitates early antibiotic administration and timely identification of at-risk populations to mitigate the risk of poor prognostic outcomes in patients.
10.Study on the clinical value of dynamic AI ultrasonic intelligent assisted diagnosis system for preoperative evaluation of thyroid nodules with diameter≤1.0 cm
Xin MIAO ; Shaoteng XIE ; Zheng WAN ; Wen TIAN ; Bing WANG ; Jing YAO ; Zelong YANG ; Yanbing JIAN ; Junwen DING ; Linlin ZHANG ; Chen LI
Chinese Journal of Endocrine Surgery 2025;19(1):24-29
Objective:To investigate the clinical value of dynamic AI ultrasonic intelligent assisted diagnosis system for preoperative evaluation of thyroid nodules with diameter ≤1.0 cm.Methods:From Apr. 1, 2023, to Dec. 30, 2023, 742 thyroid nodules with diameter ≤1.0 cm were removed from 532 patients with thyroid nodule disease who received surgical treatment in the Department of Thyroid (hernia) of the First Medical Center of the Chinese People’s Liberation Army General Hospital. Among them, 423 were d≤0.5 cm. 319 cases (235 males and 507 females) with 0.5


Result Analysis
Print
Save
E-mail