1.Survey of post-discharge exercise behavior and analysis of factors influencing exercise intensity in patients undergoing lung surgery
Hongyu ZENG ; Xiang WANG ; Tian ZHANG ; Yaqin WANG ; Xing WEI ; Zhen DAI ; Liping ZHANG ; Xiaoqin LIU ; Qiang LI ; Qiuling SHI ; Wei DAI ; Jia LIAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(05):734-742
Objective To investigate the post-discharge exercise behavior and factors influencing moderate to vigorous intensity physical activity (MVPA) in patients undergoing lung surgery. Methods A total of 2874 patients from the large prospective, observational perioperative lung symptom study cohort (CN-PRO-Lung 3) in the Department of Thoracic Surgery at Sichuan Cancer Hospital between April 7, 2021, and January 31, 2024, were selected as the survey subjects. A survey was conducted using the Investigation of Exercise Behavior after Lung Surgery questionnaire and the International Physical Activity Questionnaire-Short Form (IPAQ-SF) among patients who underwent lung surgery. Binary logistic regression was used to analyze the factors influencing patients’ engagement in MVPA. Results A total of 702 patients were surveyed, including 252 males and 450 females, with an average age of (52.4±10.2) years. Patients with lung cancer accounted for 85.9%. Only 36.0% of the patients had regular exercise habits, while 42.3% did not engage in any physical activity. The three main barriers for postoperative exercise were physical discomfort (pain, coughing, shortness of breath, etc, 54.7%), lack of professional guidance (41.7%), and concerns about the surgical wound (28.9%). The proportions of patients engaging in vigorous, moderate, and low-intensity physical activity were 5.7%, 28.2%, and 66.1%, respectively. Multivariate analysis showed that patients with a personal annual income ≥50000 yuan (OR=1.52, 95%CI 1.01-2.29, P=0.044), high school education or above (OR=1.92, 95%CI 1.33-2.76, P<0.001), and lobectomy (OR=1.44, 95%CI 1.02-2.03, P=0.037) engaged in more MVPA. Conclusion Patients undergoing lung surgery have inadequate physical activity after discharge, particularly lacking in MVPA. Patients with higher income, higher educational levels, and lobectomy are more frequently engaged in MVPA. Measures such as symptom control, providing exercise guidance, and enhancing education on wound care may potentially improve the inadequate physical activity in lung surgery patients after discharge.
2.Role of exosomal miR-320c in gingerol-mediated defense against Staphylococcus aureus infection
Zhencai XING ; Mengxue XU ; Xiang KONG ; Jinghan SUN ; Zhen MA ; Yu GAO ; Siyuan DU ; Hong ZHENG ; Yakun LIU
Acta Universitatis Medicinalis Anhui 2026;61(5):795-802
ObjectiveTo investigate the inhibitory effect of gingerol, an active component of ginger, on Staphylococcus aureus (S. aureus) infection, and to preliminarily explore its mechanism related to extracellular vesicles (EVs). MethodsS.aureus infection models were established in human umbilical vein endothelial cell (HUVECs), Vero E6 cells, and C57BL/6 mice. Experimental groups included control, infection, and gingerol-treated groups. Bacterial load and VE-cadherin protein expression were detected using immunofluorescence and Western blot. EVs were isolated by size exclusion chromatography and characterized by transmission electron microscopy and nanoparticle tracking analysis. miRNA sequencing was performed on EVs. ResultsGingerol treatment significantly reduced the bacterial load in both in vitro and in vivo infection models and upregulated VE-cadherin expression. miRNA sequencing of EVs revealed that S. aureus infection upregulated the expression of hsa-miR-320c, while gingerol treatment reversed this abnormal expression. Bioinformatic analysis further predicted that the target genes of hsa-miR-320c were significantly enriched in cell junction-related pathways. ConclusionGingerol exhibits clear antibacterial and host-protective effects, by regulating hsa-miR-320c in EVs to maintain endothelial barrier integrity.
3.Constructing a model of degenerative scoliosis using finite element method:biomechanical analysis in etiology and treatment
Kai HE ; Wenhua XING ; Shengxiang LIU ; Xianming BAI ; Chen ZHOU ; Xu GAO ; Yu QIAO ; Qiang HE ; Zhiyu GAO ; Zhen GUO ; Aruhan BAO ; Chade LI
Chinese Journal of Tissue Engineering Research 2025;29(3):572-578
BACKGROUND:Degenerative scoliosis is defined as a condition that occurs in adulthood with a coronal cobb angle of the spine>10° accompanied by sagittal deformity and rotational subluxation,which often produces symptoms of spinal cord and nerve compression,such as lumbar pain,lower limb pain,numbness,weakness,and neurogenic claudication.The finite element method is a mechanical analysis technique for computer modelling,which can be used for spinal mechanics research by building digital models that can realistically restore the human spine model and design modifications. OBJECTIVE:To review the application of finite element method in the etiology and treatment of degenerative scoliosis. METHODS:The literature databases CNKI,PubMed,and Web of Science were searched for articles on the application of finite element method in degenerative scoliosis published before October 2023.Search terms were"finite element analysis,biomechanics,stress analysis,degenerative scoliosis,adult spinal deformity"in Chinese and English.Fifty-four papers were finally included. RESULTS AND CONCLUSION:(1)The biomechanical findings from the degenerative scoliosis model constructed using the finite element method were identical to those from the in vivo experimental studies,which proves that the finite element method has a high practical value in degenerative scoliosis.(2)The study of the etiology and treatment of degenerative scoliosis by the finite element method is conducive to the prevention of the occurrence of the scoliosis,slowing down the progress of the scoliosis,the development of a more appropriate treatment plan,the reduction of complications,and the promotion of the patients'surgical operation.(3)The finite element method has gradually evolved from a single bony structure to the inclusion of soft tissues such as muscle ligaments,and the small sample content is increasingly unable to meet the research needs.(4)The finite element method has much room for exploration in degenerative scoliosis.
4.Enzyme-directed Immobilization Strategies for Biosensor Applications
Xing-Bao WANG ; Yao-Hong MA ; Yun-Long XUE ; Xiao-Zhen HUANG ; Yue SHAO ; Yi YU ; Bing-Lian WANG ; Qing-Ai LIU ; Li-He ZHANG ; Wei-Li GONG
Progress in Biochemistry and Biophysics 2025;52(2):374-394
Immobilized enzyme-based enzyme electrode biosensors, characterized by high sensitivity and efficiency, strong specificity, and compact size, demonstrate broad application prospects in life science research, disease diagnosis and monitoring, etc. Immobilization of enzyme is a critical step in determining the performance (stability, sensitivity, and reproducibility) of the biosensors. Random immobilization (physical adsorption, covalent cross-linking, etc.) can easily bring about problems, such as decreased enzyme activity and relatively unstable immobilization. Whereas, directional immobilization utilizing amino acid residue mutation, affinity peptide fusion, or nucleotide-specific binding to restrict the orientation of the enzymes provides new possibilities to solve the problems caused by random immobilization. In this paper, the principles, advantages and disadvantages and the application progress of enzyme electrode biosensors of different directional immobilization strategies for enzyme molecular sensing elements by specific amino acids (lysine, histidine, cysteine, unnatural amino acid) with functional groups introduced based on site-specific mutation, affinity peptides (gold binding peptides, carbon binding peptides, carbohydrate binding domains) fused through genetic engineering, and specific binding between nucleotides and target enzymes (proteins) were reviewed, and the application fields, advantages and limitations of various immobilized enzyme interface characterization techniques were discussed, hoping to provide theoretical and technical guidance for the creation of high-performance enzyme sensing elements and the manufacture of enzyme electrode sensors.
5.Hippocampal Extracellular Matrix Protein Laminin β1 Regulates Neuropathic Pain and Pain-Related Cognitive Impairment.
Ying-Chun LI ; Pei-Yang LIU ; Hai-Tao LI ; Shuai WANG ; Yun-Xin SHI ; Zhen-Zhen LI ; Wen-Guang CHU ; Xia LI ; Wan-Neng LIU ; Xing-Xing ZHENG ; Fei WANG ; Wen-Juan HAN ; Jie ZHANG ; Sheng-Xi WU ; Rou-Gang XIE ; Ceng LUO
Neuroscience Bulletin 2025;41(12):2127-2147
Patients suffering from nerve injury often experience exacerbated pain responses and complain of memory deficits. The dorsal hippocampus (dHPC), a well-defined region responsible for learning and memory, displays maladaptive plasticity upon injury, which is assumed to underlie pain hypersensitivity and cognitive deficits. However, much attention has thus far been paid to intracellular mechanisms of plasticity rather than extracellular alterations that might trigger and facilitate intracellular changes. Emerging evidence has shown that nerve injury alters the microarchitecture of the extracellular matrix (ECM) and decreases ECM rigidity in the dHPC. Despite this, it remains elusive which element of the ECM in the dHPC is affected and how it contributes to neuropathic pain and comorbid cognitive deficits. Laminin, a key element of the ECM, consists of α-, β-, and γ-chains and has been implicated in several pathophysiological processes. Here, we showed that peripheral nerve injury downregulates laminin β1 (LAMB1) in the dHPC. Silencing of hippocampal LAMB1 exacerbates pain sensitivity and induces cognitive dysfunction. Further mechanistic analysis revealed that loss of hippocampal LAMB1 causes dysregulated Src/NR2A signaling cascades via interaction with integrin β1, leading to decreased Ca2+ levels in pyramidal neurons, which in turn orchestrates structural and functional plasticity and eventually results in exaggerated pain responses and cognitive deficits. In this study, we shed new light on the functional capability of hippocampal ECM LAMB1 in the modulation of neuropathic pain and comorbid cognitive deficits, and reveal a mechanism that conveys extracellular alterations to intracellular plasticity. Moreover, we identified hippocampal LAMB1/integrin β1 signaling as a potential therapeutic target for the treatment of neuropathic pain and related memory loss.
Animals
;
Laminin/genetics*
;
Hippocampus/metabolism*
;
Neuralgia/metabolism*
;
Cognitive Dysfunction/etiology*
;
Male
;
Peripheral Nerve Injuries/metabolism*
;
Extracellular Matrix/metabolism*
;
Integrin beta1/metabolism*
;
Pyramidal Cells/metabolism*
;
Signal Transduction
6.A clinical study of deep learning image reconstruction algorithms in liver dual-energy CT with reduced radiation dose to further improve image quality and lesion diagnostic confidence
Yuncheng LI ; Yuguo LI ; Junlin YANG ; Jian SONG ; Xing TANG ; Wei DENG ; Zhen WANG ; Jinxiu YANG ; Bin LIU ; Yongqiang YU ; Xiaohu LI
Chinese Journal of Radiology 2025;59(1):43-49
Objective:To explore the feasibility of applying deep learning image reconstruction (DLIR) in low-radiation dose liver dual-energy CT to further improve image quality, diagnostic confidence of lesion, and accuracy of iodine concentration (IC) measurement.Methods:This prospective cohort study enrolled 60 patients scheduled for enhanced liver CT at the First Affiliated Hospital of Anhui Medical University from June 2023 to January 2024. The participants were randomly assigned into the standard dose group and low radiation dose group with 30 cases in each using randomized block method. The standard radiation dose group underwent standard-radiation dose 120 kVp scans during the venous phase, while the low radiation dose group underwent low radiation dose scans with a rapid kVp-switching spectral scanning mode at 80 kVp and 140 kVp. The effective radiation dose (ED) was calculated for both groups. The standard radiation dose group was reconstructed using adaptive statistical iterative reconstruction-V (ASIR-V) algorithm 40% (AR40 120 kVp). The low radiation dose group using high-intensity DLIR (DLIR-H) to reconstructed 40 keV and 50 keV virtual monoenergetic images (VMI) (DH-VMI 40 keV, DH-VMI 50 keV). The image quality of the above three groups was objectively evaluated through the measurement of image noise and calculation of contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) for the liver and portal vein; and the image quality was subjectively scored for image noise, contrast, lesion conspicuity, and diagnostic confidence. In the low radiation dose group, DLIR-H and ASIR-V40% reconstructed iodine maps were used to measure the liver and portal vein of IC values, standard deviations (SD), and coefficients of variation (CV). One-way analysis of variance or Kruskal-Wallis H test was used to compare the differences of subjective and objective image quality among the three groups, and paired t-test was used to compare the differences in measurement indexes between DLIR-H and ASIR-V40% reconstructed iodine maps. Results:The ED in the low radiation dose group [(2.2±0.5) mSv] was reduced by 56.8% compared to the conventional radiation dose group [(5.4±1.4) mSv]. Objective evaluations demonstrated that DH-VMI 40 keV had higher image noise, CNR, and SNR for liver and portal veins compared to AR40 120 kVp ( P<0.001). DH-VMI 50 keV had lower image noise ( P=0.200), with higher CNR and SNR for the liver and portal vein compared to AR40 120 kVp( P<0.001). In subjective evaluation, there was no statistically significant difference in image noise scores between DH-VMI 40 keV and AR40 120 kVp ( P>0.05), while the image noise score for DH-VMI 50 keV was lower than that of AR40 120 kVp ( P<0.05). Both DH-VMI 40 keV and DH-VMI 50 keV had higher scores for contrast, lesion conspicuity, and diagnostic confidence compared to those of AR40 120 kVp ( P<0.05). In the low radiation dose group, there was no statistically significant difference in IC values for the liver and portal vein between the ASIR-V40% and DLIR-H algorithm reconstructed iodine maps ( P>0.05). The SD and CV of liver and portal vein in the DLIR-H reconstructed iodine maps were lower than those in the ASIR-V40% reconstructed iodine maps ( P<0.001). Conclusions:DLIR can effectively reduce the image noise of low-energy (40, 50 keV) VMI, enhance lesion conspicuity and diagnostic confidence, and improve measurement accuracy without affecting IC values.
7.Application and development direction of finite element method in biomechanical analysis of thoracolumbar fractures of the spine
Kai HE ; Wenhua XING ; Feng LI ; Shengxiang LIU ; Xianming BAI ; Chen ZHOU ; Xu GAO ; Yu QIAO ; Qiang HE ; Zhiyu GAO ; Zhen GUO ; Aruhan BAO ; Chade LI
Chinese Journal of Tissue Engineering Research 2025;29(15):3244-3252
BACKGROUND:The highest incidence of spinal fracture is in the thoracolumbar segment,and its symptoms are back pain,posterior convexity deformity,activity limitation,or with spinal cord nerve injury causing lower limb pain,numbness,and even paraplegia and other complications.The finite element method is a digital computer modeling technique,which can simulate the physical model and carry out force analysis realistically.OBJECTIVE:To review the application of finite element method in thoracolumbar spine fractures.METHODS:We searched the Chinese and English literature databases PubMed,Web of Science,and CNKI for relevant literature on the application of the finite element analysis method in spinal thoracolumbar fracture published before March 2024.The search terms in Chinese and English were:finite element analysis methods,biomechanical phenomena,stress analysis,thoracolumbar fractures,spinal fractures.Finally,55 papers were included.RESULTS AND CONCLUSION:(1)The exploration of thoracolumbar fractures caused by different etiologies(osteoporotic,traumatic,and pathological)through the finite element method is conducive to a deeper understanding of the biomechanics of various types of thoracolumbar fractures,and to improve the individualized and fine-tuned treatment of thoracolumbar fractures.(2)The finite element analysis of a single sample or a small number of samples has the chance,and a larger number of samples are required for the future finite element analysis to reduce the chance caused by the sample.(3)The rigid structure of bones alone cannot meet the biomechanical working conditions of the integrity of the physical object,and future finite element models need to incorporate all the structures of the physical object(e.g.,soft tissues,such as muscles and ligaments)as far as possible.(4)The finite element method has been used in more studies on osteoporotic and traumatic thoracolumbar spine fractures,which will need to be more in-depth in the future,and less in the field of pathologic thoracolumbar fractures,which has a wider scope for future research.
8.Comparison of bladder volume measurement accuracy between two-dimensional ultrasound with three-dimensional reconstruction and conventional two-dimensional ultrasound
Kaixuan ZHANG ; Ying CAO ; Lijing ZUO ; Zhen WANG ; Wensheng NIE ; Yongli SONG ; Xing LIU ; Mingjian SUN ; Yuan TANG ; Yueping LIU
Chinese Journal of Radiation Oncology 2025;34(12):1238-1244
Objective:To compare the accuracy of two-dimensional (2D) ultrasound with three-dimensional (3D) reconstruction and conventional 2D ultrasound in measuring bladder volume in pelvic tumor patients, using computed tomography (CT) as the reference.Methods:A set of bladder phantoms were constructed to compare CT and ultrasound measurements with actual injected volumes. Clinical data of 104 pelvic tumor patients who received radiotherapy at the Cancer Hospital, Chinese Academy of Medical Sciences between August and December 2023 were retrospectively analyzed. Portable transabdominal ultrasound was used to obtain the largest bladder cross-section, and the maximum diameters in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions (D LR, D AP, D SI) were measured. The 2D ultrasound volume was calculated as V=0.523 × D LR × D AP × D SI. Full-bladder transverse videos were recorded and processed in Matlab R2016a through frame extraction(60 images), followed by contrast enhancement, edge detection segmentation, cubic spline interpolation, and image smoothing to achieve 3D reconstruction. Paired t-tests, intraclass correlation coefficients (ICC), and Bland-Altman analyses were performed to assess systematic bias and consistency between ultrasound methods and CT. Multivariate linear regression was applied to evaluate the effects of slice thickness, posture, age, and other factors on CT measurements. Results:In the phantom study, deviations of 2D ultrasound and CT from actual injected volumes were (0.73±3.05) ml ( t=-0.48, P=0.667) and (1.52±11.27) ml ( t=0.17, P=0.875), with ICC values>0.999. In the clinical study, mean bladder volumes measured by 3D-reconstructed ultrasound, conventional 2D ultrasound, and CT were (373.5±153.31), (314.89±135.28), (382.82±157.57) ml, respectively. The 3D-reconstructed method showed excellent agreement with CT (ICC=0.98; Bland-Altman mean bias=-9.32 ml, P=0.096), while 2D ultrasound also showed good consistency (ICC=0.91), but significantly underestimated bladder volume (mean bias=-67.93 ml, P<0.001). Subgroup analysis revealed that 2D ultrasound had the best agreement with CT in the medium-volume group (200-500 ml, ICC=0.902), whereas agreement decreased in the small-volume (<200 ml, ICC=0.884) and large-volume (>500 ml, ICC=0.840) groups (all P<0.001). The 3D-reconstructed ultrasound maintained excellent consistency with CT across all subgroups (all ICC>0.95), and the measured bladder volume was not statistically significant. Multivariate regression showed that slice thickness, posture, age, sex, and surgical status had no significant effects on CT measurements. Conclusions:Ultrasound with 3D reconstruction enables accurate bladder volume monitoring through true 3D contour reconstruction, while conventional 2D ultrasound systematically underestimates bladder volume and requires correction.
9.Kitchen Ventilation Attenuate the Association of Solid Fuel Use with Sarcopenia: A Cross-Sectional and Prospective Study.
Ying Hao YUCHI ; Wei LIAO ; Jia QIU ; Rui Ying LI ; Ning KANG ; Xiao Tian LIU ; Wen Qian HUO ; Zhen Xing MAO ; Jian HOU ; Lei ZHANG ; Chong Jian WANG
Biomedical and Environmental Sciences 2025;38(4):511-515

Result Analysis
Print
Save
E-mail